RF Exposure

FCC ID: 2ARNWOEH02

RF Exposure Info

Download: PDF
FCCID_4161654

RADIO FREQUENCY RADIATION EXPOSURE

KDB 447498

47 CFR §§1.1307 and 2.1091

Radio frequency radiation exposure evaluation.

Mobile devices that operate under CFR47 Part 90 are subject to routine environmental
evaluation for RF exposure prior to equipment authorization or use if they operate at
frequencies of 1.5 GHz or below and their effective radiated power (ERP) is 1.5 watts or
more for FCC requirements.

Prediction of MPE limit at a given distance


                        EIRP                                    EIRP
                 S =          re - arranged R =
                        4πR 2                                   S 4π

where:

S = power density
R = distance to the centre of radiation of the antenna
ERP = EUT Maximum power



                                                                                Distance (R) cm
                         Maximum               Maximum
   Prediction                                                 Power density      required to be
                           ERP                  EIRP
Frequency (MHz)                                            limit (S) (mW/cm2)     less than (S)
                          (mW)                  (mW)
                                                                                    mW/cm2

     910.43                 5.57                 5.57       0.606335647             0.855



                                                                                Distance (R) cm
                         Maximum               Maximum
   Prediction                                                 Power density      required to be
                           ERP                  EIRP
Frequency (MHz)                                            limit (S) (mW/cm2)     less than (S)
                          (mW)                  (mW)
                                                                                    mW/cm2

      918.1                 5.34                 5.34       0.610941029             0.834


Result

The EUT meets the limit requirements at the distances specified based on the maximum allowed ERP
for a booster as per 90.219.


LIMITS
FCC LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)

(B) Limits for General Population/Uncontrolled Exposure

                                                                                   Averaging
                                Electric        Magnetic           Power
   Frequency Range                                                                     Time
                               Field (V/m       Field (A/m         Density
        (MHz)                                                                     |E| , |H|2 or S
                                                                                     2
                                  rms)             rms)            (W/m2)
                                                                                    (minutes)
         0.3-1.34               614            1.63                 (100)*               30
         1.34-30               824/f          2.19/f               (180/f2)*             30
          30-300               27.5           0.073                   0.2                30
        300-1500                 --             --                  f/1500               30
      1500-100,000               --             --                    1.0                30
f = frequency in MHz *Plane-wave equivalent power density


RF Field Strength Limits for Devices Used by the General Public (Uncontrolled Environment)

     Frequency                 Electric        Magnetic             Power         Averaging
       Range                    Field             Field            Density          Time
        (MHz)                (V/m rms)         (A/m rms)           (W/m2)         (minutes)
       0.003-1                   280               2.19                -              6
         1-10                   280/ƒ            2.19/ƒ                -              6
        10-30                     28             2.19/ƒ                -              6
       30-300                     28              0.073               2*              6
      300-1500                1.585 ƒ 0.5      0.0042 ƒ 0.5         ƒ/150             6
     1500-15000                  61.4             0.163               10              6
    15000-150000                 61.4             0.163               10          616000/ƒ 1.2
   150000-300000              0.158 ƒ 0.5    4.21 x 10-4 ƒ 0.5   6.67 x 10-5 ƒ    616000/ƒ 1.2



Document Created: 2019-02-07 12:40:05
Document Modified: 2019-02-07 12:40:05

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC