Test report

FCC ID: 2ARMP-DM8856

Test Report

Download: PDF
FCCID_4473137

                                                                                Shenzhen CTL Testing Technology Co., Ltd.
                                                                             Tel: +86-755-89486194 E-mail: ctl@ctl-lab.com


                                          TEST REPORT
                                47 CFR FCC Part 15 Subpart C 15.231(e)

Report Reference No. ................. : CTL1908238012-WF

           Compiled by:                                          Happy Guo
( position+printed name+signature)                          (File administrators)

             Tested by:                                         Nice Nong
( position+printed name+signature)                            (Test Engineer)

           Approved by:                                           Ivan Xie
( position+printed name+signature)                               (Manager)


Product Name.............................. : WEATHER STATION
Model/Type reference ................. : DM8856
List Model(s) ................................ : N/A
Trade Mark ................................... : N/A
FCC ID .......................................... : 2ARMP-DM8856
Applicant’s name ........................ : Digi-Max Technology Limited
                                            Room 708, Building 3, XIN YUAN, Jinshan Industrial District,
Address of applicant .................. :
                                            Fuzhou, Fujian, China
Test Firm ...................................... : Shenzhen CTL Testing Technology Co., Ltd.

                                                 Floor 1-A, Baisha Technology Park, No.3011, Shahexi Road,
Address of Test Firm .................. :
                                                 Nanshan District, Shenzhen, China 518055
Test specification ........................ :
Standard ........................................ : 47 CFR FCC Part 15 Subpart C 15.231(e)

TRF Originator .............................. : Shenzhen CTL Testing Technology Co., Ltd.
Master TRF ................................... : Dated 2011-01
Date of receipt of test item ......... : Aug. 29, 2019
Date of sampling ......................... : Aug. 29, 2019
Date of Test Date ......................... : Aug. 29, 2019–Sep. 10, 2019
Data of Issue ................................ : Sep. 11, 2019
Result ........................................... : Pass
Shenzhen CTL Testing Technology Co., Ltd. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the
Shenzhen CTL Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the
material. Shenzhen CTL Testing Technology Co., Ltd. takes no responsibility for and will not assume
liability for damages resulting from the reader's interpretation of the reproduced material due to its
placement and context.


                                 TEST REPORT
                                                                              Sep. 11, 2019
 Test Report No. :                  CTL1908238012-WF
                                                                              Date of issue

  Equipment under Test       :    WEATHER STATION


  Model /Type                :    DM8856


  Listed Models              :    N/A


  Applicant                  :    Digi-Max Technology Limited


                             :    Room 708, Building 3, XIN YUAN, Jinshan Industrial
  Address
                                  District, Fuzhou, Fujian, China


  Manufacturer               :    PUTIAN JOKO ELECTRONIC CO., LTD


                             :    NO.4099, GUOHUAN EAST ROAD, SHIXI VILLAGE,
  Address                         JIANGKOU TOWN,HANJIANG DISCTRICT, PUTIAN CITY,
                                  CHINA




                  Test result                                             Pass *
* In the configuration tested, the EUT complied with the standards specified page 5.
 The test results presented in this report relate only to the object tested.
 This report shall not be reproduced, except in full, without the written approval of the issuing testing
 laboratory.


V1.0                                   Page 3 of 24            Report No.: CTL1908238012-WF


                                  ** Modified History **
  Version               Description          Issued Data      Report No.         Remark
 Version 1.0   Initial Test Report Release    2019-09-11   CTL1908238012-WF      Tracy Qi


V1.0                                                                      Page 4 of 24                                         Report No.: CTL1908238012-WF



                                                                       Table of Contents                                                                                      Page
1.     SUMMARY............................................................................................................................................................ 5
     1.1.     TEST STANDARDS.......................................................................................................................................................... 5
     1.2.     TEST DESCRIPTION ........................................................................................................................................................ 5
     1.3.     TEST FACILITY .............................................................................................................................................................. 6
     1.4.     STATEMENT OF THE MEASUREMENT UNCERTAINTY ............................................................................................................... 6
2.     GENERAL INFORMATION....................................................................................................................................... 8
     2.1.     ENVIRONMENTAL CONDITIONS ........................................................................................................................................ 8
     2.2.     GENERAL DESCRIPTION OF EUT ...................................................................................................................................... 8
     2.3.     EQUIPMENTS USED DURING THE TEST .............................................................................................................................. 8
     2.4.     RELATED SUBMITTAL(S) / GRANT (S) ................................................................................................................................ 9
     2.5.     MODIFICATIONS ........................................................................................................................................................... 9
3.     TEST CONDITIONS AND RESULTS ......................................................................................................................... 10
     3.1.     CONDUCTED EMISSION (AC MAIN) ............................................................................................................................... 10
     3.2.     RADIATED EMISSION ................................................................................................................................................... 11
     3.3.     20DB BANDWIDTH ..................................................................................................................................................... 16
     3.4.     DURATION OF TRANSMISSION AND SILENT PERIOD............................................................................................................ 17
     3.4.     ANTENNA REQUIREMENT ............................................................................................................................................. 19
4.     TEST SETUP PHOTOS OF THE EUT ........................................................................................................................ 20
5.     EXTERNAL AND INTERNAL PHOTOS OF THE EUT .................................................................................................. 21


V1.0                                      Page 5 of 24                 Report No.: CTL1908238012-WF


1. SUMMARY
1.1. Test Standards
The tests were performed according to following standards:

FCC Rules Part 15.231: Periodic operation in the band 40.66-40.70 MHz and above 70 MHz.

ANSI C63.10:2013 : American National Standard for Testing Unlicensed Wireless Devices

1.2. Test Description
FCC and IC Requirements
FCC Part 15.207                          Conducted Emission                                 N/A
FCC Part 15.231(e)                       Duration of Transmission and Silent Period        PASS
FCC Part 15.231(e)                       Electric Field Strength of Fundamental Emission   PASS
FCC Part 15.205 &15.209& 15.231(e)       Electric Field Strength of Spurious Emission      PASS
FCC Part 15.231(c)                   -20dB bandwidth                                       PASS
   Remark: The measurement uncertainty is not included in the test result.


V1.0                                        Page 6 of 24                  Report No.: CTL1908238012-WF



1.3. Test Facility
1.3.1   Address of the test laboratory
Shenzhen CTL Testing Technology Co., Ltd.
Floor 1-A, Baisha Technology Park, No. 3011, Shahexi Road, Nanshan, Shenzhen 518055 China

There is one 3m semi-anechoic chamber and two line conducted labs for final test. The Test Sites
meet the requirements in documents ANSI C63.4 and CISPR 22/EN 55022 requirements.

1.3.2 Laboratory accreditation
The test facility is recognized, certified, or accredited by the following organizations:
CNAS-Lab Code: L7497
Shenzhen CTL Testing Technology Co., Ltd. has been assessed and proved to be in compliance with
CNAS-CL01 Accreditation Criteria for Testing and Calibration Laboratories (identical to ISO/IEC 17025:
2005 General Requirements) for the Competence of Testing and Calibration Laboratories.
A2LA-Lab Cert. No. 4343.01
Shenzhen CTL Testing Technology Co., Ltd, EMC Laboratory has been accredited by A2LA for
technical competence in the field of electrical testing, and proved to be in compliance with ISO/IEC
17025: 2005 General Requirements for the Competence of Testing and Calibration Laboratories and
any additional program requirements in the identified field of testing.
IC Registration No.: 9518B
CAB identifier: CN0041
The 3m alternate test site of Shenzhen CTL Testing Technology Co., Ltd. EMC Laboratory has been
registered by Innovation, Science and Economic Development Canada to test to Canadian radio
equipment requirements with Registration No.: 9518B on Jan. 22, 2019.
FCC-Registration No.: 399832
Designation No.: CN1216
Shenzhen CTL Testing Technology Co., Ltd. EMC Laboratory has been registered and fully described
in a report filed with the (FCC) Federal Communications Commission. The acceptance letter from the
FCC is maintained in our files. Registration 399832, December 08, 2017.

1.4. Statement of the measurement uncertainty
The data and results referenced in this document are true and accurate. The reader is cautioned that
there may be errors within the calibration limits of the equipment and facilities. The measurement
uncertainty was calculated for all measurements listed in this test report acc. to CISPR 16 - 4
“Specification for radio disturbance and immunity measuring apparatus and methods – Part 4:
Uncertainty in EMC Measurements“ and is documented in the Shenzhen CTL Testing Technology Co.,
Ltd. quality system acc. to DIN EN ISO/IEC 17025. Furthermore, component and process variability of
devices similar to that tested may result in additional deviation. The manufacturer has the sole
responsibility of continued compliance of the device.

Hereafter the best measurement capability for CTL laboratory is reported:
                                                                    Measurement
                             Test                                                             Notes
                                                                      Uncertainty
                Transmitter power conducted                            ±0.57 dB                 (1)
                 Transmitter power Radiated                            ±2.20 dB                 (1)
        Conducted spurious emission 9KHz-40 GHz                        ±2.20 dB                 (1)
                    Occupied Bandwidth                                 ±0.01ppm                 (1)
               Radiated Emission 30~1000MHz                             ±4.10dB                 (1)
               Radiated Emission Above 1GHz                             ±4.32dB                 (1)




V1.0                                           Page 8 of 24             Report No.: CTL1908238012-WF


2. GENERAL INFORMATION
2.1. Environmental conditions
During the measurement the environmental conditions were within the listed ranges:
                Normal Temperature:                                         25°C
                    Relative Humidity:                                      55 %
                      Air Pressure:                                       101 kPa

2.2. General Description of EUT
Product Name:                         WEATHER STATION
Model/Type reference:                 DM8856
Power supply:                         DC 3V from battery
Modulation:                           ASK
Operation frequency:                  433.91MHz
Channel number:                       1
Antenna type:                         PCB antenna
Antenna gain:                   0dBi
Note: For more details, please refer to the user’s manual of the EUT.

2.3. Equipments Used during the Test
                                                                              Calibration   Calibration
 Test Equipment             Manufacturer         Model No.     Serial No.
                                                                                Date        Due Date
                                                              3560.6550.1
         LISN                   R&S               ENV216                      2019/05/20    2020/05/19
                                                                   2
         LISN                   R&S              ESH2-Z5      860014/010      2019/05/20    2020/05/19
                          Sunol Sciences
  Bilog Antenna                                     JB1         A061713       2019/05/20    2020/05/19
                              Corp.
EMI Test Receiver               R&S                ESCI       1166.5950.03    2019/05/20    2020/05/19
Spectrum Analyzer              Agilent            E4407B      MY41440676      2019/05/20    2020/05/19
Spectrum Analyzer              Agilent             N9020      US46220290      2019/05/20    2020/05/19
Spectrum Analyzer             Keysight            N9020A      MY53420874      2019/05/20    2020/05/19
       Controller          EM Electronics        EM 1000        060859        2019/05/20    2020/05/19
                          Sunol Sciences
  Horn Antenna                                   DRH-118        A062013       2019/05/20    2020/05/19
                              Corp.
   Active Loop
                                Da Ze            ZN30900A          /          2019/05/20    2020/05/19
    Antenna
       Amplifier               Agilent             8449B      3008A02306      2019/05/20    2020/05/19
       Amplifier               Agilent             8447D      2944A10176      2019/05/20    2020/05/19
Temperature/Humi
                             Gangxing            CTH-608          02          2019/05/20    2020/05/19
dity Meter
High-Pass Filter            micro-tranics       HPM50108         G174         2019/05/20    2020/05/19


V1.0                                     Page 9 of 24                  Report No.: CTL1908238012-WF


High-Pass Filter       micro-tranics       HPM50111             G142        2019/05/20     2020/05/19
                      HUBER+SUHN           SUCOFLEX                         2019/05/20     2020/05/19
  Coaxial Cables                                                 10m
                          ER              104PEA-10M
                      HUBER+SUHN           SUCOFLEX                         2019/05/20     2020/05/19
  Coaxial Cables                                                 3m
                          ER               104PEA-3M
                      HUBER+SUHN           SUCOFLEX                         2019/05/20     2020/05/19
  Coaxial Cables                                                 3m
                          ER               104PEA-3M
       RF Cable          Megalon            RF-A303              N/A        2019/05/20     2020/05/19
  Power Sensor            Agilent           U2021XA           MY5365004     2019/05/20     2020/05/19
   Power Meter            Agilent            U2531A           TW53323507    2019/05/20     2020/05/19
The calibration interval was one year

2.4. Related Submittal(s) / Grant (s)
This submittal(s) (test report) is intended to comply with Section 15.231 of the FCC Part 15, Subpart C
Rules.

2.5. Modifications
No modifications were implemented to meet testing criteria.


V1.0                                        Page 10 of 24                Report No.: CTL1908238012-WF


3. TEST CONDITIONS AND RESULTS
3.1. Conducted Emission (AC Main)
LIMIT
FCC CFR Title 47 Part 15 Subpart C Section 15.207

                                                                  Limit (dBuV)
          Frequency range (MHz)
                                                    Quasi-peak                      Average

                  0.15-0.5                            66 to 56*                     56 to 46*

                   0.5-5                                    56                         46

                    5-30                                    60                         50

* Decreases with the logarithm of the frequency.

TEST CONFIGURATION




TEST PROCEDURE

1.     The equipment was set up as per the test configuration to simulate typical actual usage per the
       user’s manual. The EUT is a flood stand system; a wooden table with a height of 0.1 meters is
       used and is placed on the ground plane as per ANSI C63.10-2013.
2.     Support equipment, if needed, was placed as per ANSI C63.10-2013
3.     All I/O cables were positioned to simulate typical actual usage as per ANSI C63.10-2013
4.     If a EUT received DC power from the USB Port of Notebook PC, the PC’s adapter received
       AC120V/60Hz power through a Line Impedance Stabilization Network (LISN) which supplied
       power source and was grounded to the ground plane.
5.     All support equipments received AC power from a second LISN, if any.
6.     The EUT test program was started. Emissions were measured on each current carrying line of the
       EUT using a spectrum Analyzer / Receiver connected to the LISN powering the EUT. The LISN
       has two monitoring points: Line 1 (Hot Side) and Line 2 (Neutral Side). Two scans were taken:
       one with Line 1 connected to Analyzer / Receiver and Line 2 connected to a 50 ohm load; the
       second scan had Line 1 connected to a 50 ohm load and Line 2 connected to the Analyzer /
       Receiver.
7.     Analyzer / Receiver scanned from 150 KHz to 30MHz for emissions in each of the test modes.
8.     During the above scans, the emissions were maximized by cable manipulation.
TEST RESULTS
Not applicable for device which is battery supply.


V1.0                                      Page 11 of 24                 Report No.: CTL1908238012-WF


3.2. Radiated Emission
Limit
For intentional device, according to 15.209(a) the general requirement of field strength of radiated
emission from intentional radiators at a distance of 3 meters shall not exceed the following table.
  Frequency (MHz)       Distance (Meters)              Radiated (dBμV/m)               Radiated (μV/m)
       0.009-0.49                3             20log(2400/F(KHz))+40log(300/3)           2400/F(KHz)
       0.49-1.705                3             20log(24000/F(KHz))+ 40log(30/3)         24000/F(KHz)
        1.705-30                 3                   20log(30)+ 40log(30/3)                   30
         30-88                   3                            40.0                            100
        88-216                   3                            43.5                            150
        216-960                  3                            46.0                            200
       Above 960                 3                            54.0                            500
In addition to the provisions of 15.231(b) and RSS 210-A1.1.2, the field strength of emissions from
intentional radiators operated under this section shall not exceed the following:




[Where F is the frequency in MHz, the formulas for calculating the maximum permitted fundamental
field strengths are as follows: for the band 260-470 MHz, μV/m at 3 meters =41.6667(F) - 7083.3333.
The maximum permitted unwanted emission level is 20 dB below the maximum permitted fundamental
level.]

TEST CONFIGURATION
                        (A) Radiated Emission Test Set-Up, Frequency Below 30MHz




                       (B) Radiated Emission Test Set-Up, Frequency below 1000MHz


V1.0                                      Page 12 of 24                Report No.: CTL1908238012-WF




                        (C) Radiated Emission Test Set-Up, Frequency above 1000MHz




Test Procedure

1.     Below 1GHz measurement the EUT is placed on a turntable which is 0.8m above ground plane,
       and above 1GHz measurement EUT was placed on a low permittivity and low loss tangent turn
       table which is 1.5m above ground plane.
2.     Maximum procedure was performed by raising the receiving antenna from 1m to 4m and rotating
       the turn table from 0℃ to 360℃ to acquire the highest emissions from EUT
3.     And also, each emission was to be maximized by changing the polarization of receiving antenna
       both horizontal and vertical.
4.     Repeat above procedures until all frequency measurements have been completed.


V1.0                                            Page 13 of 24                      Report No.: CTL1908238012-WF


TEST RESULTS

The emissions from 30MHz to 5GHz are measured peak and average level, below 1 GHz measured
QP level, detailed test data please see below. Besides, we tested 3 directions and recorded the worst
data.

        Emission          Frequency            Reading           Limit          Margin                        Direction
                                                                                              Detector
         Styles             (MHz)             (dBuV/m)         (dBuV/m)          (dB)                          (H/V)
      Fundamental           433.91              83.24             92.87         9.63            PK               H
        Spurious            435.87              48.36             52.87          4.51           PK               H
       Harmonics            867.82              50.58             52.87          2.29           PK               H
       Harmonics            1735.64             51.37             52.87          1.50           PK               H
            --                --                  --               --             --             --              --
      Fundamental           433.91              84.16             92.87         8.71            PK               V
        Spurious            435.87              49.89             52.87          2.98           PK               V
       Harmonics            867.82              50.36             52.87          2.51           PK               V
       Harmonics            1735.64             51.09             52.87          1.78           PK               V
            --                  --               --                --             --             --              --



                                         PK                            AV
      Emission        Frequency                       AV Factor                     Limit         Margin      Direction
                                        Level                         Level
       Styles           (MHz)                          (dB/m)                     (dBuV/m)         (dB)        (H/V)
                                      (dBuV/m)                      (dBuV/m)
     Fundamental        433.91          83.24           -12.39          70.85          72.87          2.02        H
      Spurious          435.87          48.36           -12.39          35.97          52.87          16.90       H
     Harmonics          867.82          50.58           -12.39          38.41          52.87          14.46       H
     Harmonics         1735.64          51.37           -12.39          38.98          52.87          13.89       H
          --              --              --              --              --             --            --         --
     Fundamental        433.91          84.16           -12.39          71.77          72.87          1.10        V
      Spurious          435.87          49.89           -12.39          37.50          52.87          15.37       V
     Harmonics          867.82          50.36           -12.39          37.97          52.87          14.90       V
     Harmonics         1735.64          51.09           -12.39          38.70          52.87          14.17       V
          --               --            --               --              --             --            --         --
Note:
1.     AV Level (dBuV/m)= PK Level (dBuV/m)+ AV Factor(dB)
2.     In a transmit cycle 70ms period found 0.47ms burst 36pcs, the Duty Cycle can calculate as below:
       Duty Cycle= (0.47*36)/70=0.241
       AV Factor=20*log(Duty Cycle)=20*log(0.241)=-12.39
      (The plot of Duty Cycle See the follow page)


V1.0            Page 14 of 24                     Report No.: CTL1908238012-WF




               (Transmit cycle 70ms)




       (Total Bursts in a transmit cycle 36pcs)


V1.0   Page 15 of 24          Report No.: CTL1908238012-WF




       (0.47ms burst 36pcs)


V1.0                                    Page 16 of 24                Report No.: CTL1908238012-WF



3.3. 20dB Bandwidth
Limit
According to 47 CFR 15.231(c) The bandwidth of the emission shall be no wider than 0.25% of the
centre frequency for devices operating above 70MHz and below 900MHz. Bandwidth is determined at
the points 20dB down from the modulated carrier.

Test Configuration



                                                             Spectrum
                         EUT
                                                             Analyzer



Test Procedure

The 20dB bandwidth and 99% bandwidth is measured with a spectrum analyzer connected via a
receive antenna placed near the EUT while the EUT is operating in transmission mode.
The 20dB bandwidth is defined as the total spectrum the power of which is higher than peak power
minus 20dB.
The occupied bandwidth (OBW), that is the frequency bandwidth such that, below its lower and above
its upper frequency limits, the mean powers radiated are each equal to 0.5 percent of the total mean
power radiated by a given emission.

Test Results


                  Channel
                                99% OBW       20dB bandwidth             Limit
 Modulation      Frequency                                                                 Result
                                  (KHz)           (KHz)                 (KHz)
                   (MHz)
       ASK         433.91         66.927           15.46        0.25%*433.91=1084.8         Pass
Test plot as follows:
                                           ASK Modulation


V1.0                                    Page 17 of 24                 Report No.: CTL1908238012-WF



3.4. Duration of Transmission and Silent Period
 Limit
 devices operated under the provisions of this paragraph shall be provided with a means for
 automatically limiting operation so that the duration of each transmission shall not be greater than
 one second and the silent period between transmissions shall be at least 30 times the duration of the
 transmission but in no case less than 10 seconds.
 Test Configuration


                                                           Spectrum
                       EUT
                                                           Analyzer


Test Procedure

1. Set SPA Center Frequency = Fundamental frequency, RBW = 100 kHz, VBW =300 kHz, Span = 0Hz.
Sweep time =20seconds.

2. Set EUT as normal operation and press Transmitter button.

3. Set SPA View. Delta Mark time.

TEST RESULTS

duration of each transmission=880ms<1s     PASS

Silent period between transmissions=30.07s>10s PASS

30 times the duration of the transmission=26.4s<30.07s   PASS


V1.0   Page 18 of 24   Report No.: CTL1908238012-WF


V1.0                                      Page 19 of 24                 Report No.: CTL1908238012-WF


3.4. Antenna Requirement

Standard Applicable

According to FCC Part 15C 15.203
a) An intentional radiator shall be de-signed to ensure that no antenna other than that furnished by
   the responsible party shall be used with the device.
b) The manufacturer may design the unit so that a broken antenna can be replaced by the user, but
   the use of a standard antenna jack or electrical connector is prohibited.



Refer to statement below for compliance.
The manufacturer may design the unit so that the user can replace a broken antenna, but the use of a
standard antenna jack or electrical connector is prohibited. Further, this requirement does not apply to
intentional radiators that must be professionally installed.

Antenna Connected Construction

The antenna used in this product is an internal Antenna, The directional gains of antenna used for
transmitting is 0 dBi.




                                                                                     Antenna


V1.0                     Page 20 of 24   Report No.: CTL1908238012-WF


4. Test Setup Photos of the EUT


V1.0                      Page 21 of 24          Report No.: CTL1908238012-WF


5. External and Internal Photos of the EUT
                        External Photos of EUT


V1.0   Page 22 of 24   Report No.: CTL1908238012-WF


V1.0     Page 23 of 24          Report No.: CTL1908238012-WF

       Internal Photos of EUT




                                              Antenna


V1.0                       Page 24 of 24                Report No.: CTL1908238012-WF




       ********************** End of Report **********************