Test report.pdf

FCC ID: 2ARIX-CSI-RM650

Test Report

Download: PDF
FCCID_4069278

                                                                                               210 Cougar court
               Advanced                                                                  Hillsborough, NJ 08844
                                                                                               Tel: (908) 927 9288
               Compliance Laboratory                                                          Fax: (908) 927 0728



   ELECTROMAGNETIC EMISSION COMPLIANCE REPORT
                                                    of
                                   WIRELESS I/O MODULE
                                    MODEL: CSI-RM650
                                  FCC ID: 2ARIX-CSI-RM650
                                         October 30, 2018


    This report concerns (check one): Original grant                 x       Class II change
    Equipment type: Low Power Intentional Radiator


    Deferred grant requested per 47 CF 0.457(d)(1)(ii)?    yes            no     x
                                    If yes, defer until:                     (date)
    Company agrees to notify the Commission by                                (date)
    of the intended date of announcement of the product so that the grant can be
    issued on that date.


    Transition Rules Request per 15.37?                    yes            no    x
    If no, assumed Part 15, Subpart B for unintentional radiators - the new 47 CFR
    [10-1-90 Edition] provision.


    Report prepared for:                            DATAONLINE LLC
    Report prepared by:                    Advanced Compliance Lab
    Report number:                              0048-180920-01-FCC



Lab Code: 200101   The test result in this report IS supported and covered by the NVLAP accreditation


                            Model No.: CSI-RM650                       FCC ID: 2ARIX-CSI-RM650




                                                          Table of Contents

Report Cover Page .........................................................................................................1

Table of Contents ...........................................................................................................2

Figures .............................................................................................................................3


1. GENERAL INFORMATION ......................................................................................4
      1.1 Verification of Compliance............................................................................4
      1.2 Equipment Modifications...............................................................................5
      1.3 Product Information .......................................................................................6
      1.4 Test Methodology ..........................................................................................6
      1.5 Test Facility....................................................................................................6
      1.6 Test Equipment ..............................................................................................6
      1.7 Statement for the Document Use ...................................................................8
2. PRODUCT LABELING ..............................................................................................9
3. SYSTEM TEST CONFIGURATION..........................................................................10
      3.1 Justification ....................................................................................................10
      3.2 Special Accessories ........................................................................................10
      3.3 Configuration of Tested System ....................................................................10
4. SYSTEM SCHEMATICS ...........................................................................................14
5. CONDUCTION EMISSION DATA ...........................................................................15
      5.1 Field Strength Calculation .............................................................................18
      5.2 Test Methods and Conditions ........................................................................18
      5.3 Test Data ........................................................................................................18
6. RADIATED EMISSION DATA .................................................................................15
      6.1 Field Strength Calculation .............................................................................18
      6.2 Test Methods and Conditions ........................................................................18
      6.3 Test Data ........................................................................................................18
7. EUT RECEIVING MODE VERIFICATION ..............................................................22
8. PHOTOS OF TESTED EUT .......................................................................................24




———————————————————————————————————————————————
Advanced Compliance Lab, 210 Cougar Court, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927-0728


                                                                           2


                          Model No.: CSI-RM650                    FCC ID: 2ARIX-CSI-RM650




                                                                Figures
Figure 2.1 ID Label ........................................................................................................9

Figure 2.2 Location of Label on Back of the EUT ......................................................9

Figure 3.1 Radiated Test Setup.....................................................................................11

Figure 3.2 Radiated Configuration Test Setup ...........................................................12

Figure 3.3 Conducted Test Setup .................................................................................13

Figure 4.1 EUT Schematics ...........................................................................................14

Figure 5.1 Line Conducted Emission ...........................................................................16

Figure 5.2 Neutral Conducted Emission ......................................................................17

Figure 8.1 -8.15 EUT Photos .........................................................................................25+




———————————————————————————————————————————————
Advanced Compliance Lab, 210 Cougar Court, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927-0728


                                                                      3


                    Model No.: CSI-RM650           FCC ID: 2ARIX-CSI-RM650




1. GENERAL INFORMATION
1.1 Verification of Compliance

                 EUT:               Wireless I/O Module

               Model:               CSI-RM650

            Applicant:              DATAONLINE LLC

            Test Type:              FCC Part 15C Sec. 15.249 CERTIFICATION

                Result:             PASS

            Tested by:              ADVANCED COMPLIANCE LABORATORY

            Test Date:              October 15, 2018 ~ October 30, 2018

     Report Number:                 0048-180920-01-FCC

The above equipment was tested by Compliance Laboratory, Advanced Technologies, Inc. for
compliance with the requirement set forth in the FCC rules and regulations Part 15 subpart C. This
said equipment in the configuration described in the report, shows the maximum emission levels
emanating from equipment are within the compliance requirements.

The estimated uncertainty of the test result is given as following. The method of uncertainty
calculation is provided in Advanced Compliance Lab. Doc. No. 0048-01-01.

                                  Prob. Dist.   Uncertainty(dB)    Uncertainty(dB)     Uncertainty(dB)
                                                 30-1000MHz          1-6.5GHz            Conducted
Combined Std. Uncertainty uc        norm.           ±2.36               ±2.99               ±1.83




____________________
Wei Li                                                                    Date 10/30/2018
Lab Manager
Advanced Compliance Lab




———————————————————————————————————————————————
Advanced Compliance Lab, 210 Cougar Court, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927-0728


                                                      4


                    Model No.: CSI-RM650           FCC ID: 2ARIX-CSI-RM650




1.2 Equipment Modifications



N/A




———————————————————————————————————————————————
Advanced Compliance Lab, 210 Cougar Court, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927-0728


                                                     5


                    Model No.: CSI-RM650           FCC ID: 2ARIX-CSI-RM650




1.3 Product Information

                                      System Configuration
        ITEM                    DESCRIPTION                   ID                                CABLE
        Product         Wireless I/O Module          FCC ID: 2ARIX-CSI-
                        CSI-RM650   (1)              RM650
      Housing           Plastic
    Power Supply        5V~24V AC/DC provided by
                        Optional adapter with rated
                        input:100-240V~/50-60Hz
   Operation Freq.      915MHz
     Receiver           CSI-RM650(RX)                        Verification

    (1) EUT submitted for grant.



1.4 Test Methodology

Radiated tests were performed according to the procedures in ANSI C63.4-2014 & & ANSI
C63.10-2013 at an antenna to EUT distance of 3 meters.



1.5 Test Facility

The open area test site and conducted measurement facility used to collect the radiated and
conducted data are located at Hillsborough, New Jersey, which is designated by IC as “ site IC
3130A” This site has been accepted by FCC to perform measurements under Part 15 or 18 in a
letter dated May 19, 1997 (Refer to: 31040/PRV 1300F2). The NVLAP Lab code for accreditation
of FCC EMC Test Method is: 200101-0.


1.6 Test Equipment

 Manufacture         Model        Serial No.              Description                Cal Due
                                                                                    dd/mm/yy
Hewlett-Packard     HP8546A      3448A00290              EMI Receiver                25/09/19
                                                3Hz-26.5GHz Spectrum
    Agilent         E4440A       US40420700                                          17/06/19
                                                Analyzer
     R &S            ESPI          100018         9KHz-7GHz EMI Receiver             25/08/19
    EMCO             3104C        9307-4396     20-300MHz Biconical Antenna          12/11/18

    EMCO             3146         9008-2860       200-1000MHz Log-Periodic           13/11/18
                                                          Antenna

———————————————————————————————————————————————
Advanced Compliance Lab, 210 Cougar Court, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927-0728


                                                      6


                     Model No.: CSI-RM650             FCC ID: 2ARIX-CSI-RM650




     EMCO              3115           49225           Double Ridge Guide Horn              28/11/18
                                                              Antenna
                      ALR-                           10KHz-30MHz Active Loop
Electro-Meterics     25M/30
                                       289                                                 28/05/19
                                                              Antenna
 COM-POWER          L1215A           191994         Line Impedance Stabilization           24/03/19
                                                             Networks
 Fischer Custom      LISN-2        900-4-0009       Line Impedance Stabilization           18/03/19
                                                             Networks
All Test Equipment Used are Calibrated Traceable to NIST Standards. Calibration Interval: 2 Years




———————————————————————————————————————————————
Advanced Compliance Lab, 210 Cougar Court, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927-0728


                                                        7


                    Model No.: CSI-RM650           FCC ID: 2ARIX-CSI-RM650




1.7 Statement for the Document Use

This report shall not be reproduced except in full, without the written approval of the laboratory.
And this report must not be used by the client to claim product endorsement by NVLAP or any
agency of the U.S. Government.




———————————————————————————————————————————————
Advanced Compliance Lab, 210 Cougar Court, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927-0728


                                                     8


                    Model No.: CSI-RM650           FCC ID: 2ARIX-CSI-RM650




2. PRODUCT LABELING

                    BioTillion Wireless I/O Module
                    Model No.: CSI-RM650
                    FCC ID: 2ARIX-CSI-RM650



                      This device complies with part 15 of the FCC Rules.
                      Operating is subject to the following two
                      conditions: (1) This device may not cause harmful
                      interference, and (2) this device must accept any
                      interference received, including interference that
                      may cause undesired operation.




                                          Figure 2.1 ID Label




                                                   ID Label




                                Figure 2.2 Location of Label on EUT




———————————————————————————————————————————————
Advanced Compliance Lab, 210 Cougar Court, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927-0728


                                                     9


                    Model No.: CSI-RM650           FCC ID: 2ARIX-CSI-RM650




3. SYSTEM TEST CONFIGURATION
3.1 Justification

The system was configured for testing in a typical fashion (as a customer would normally use it).
The following antenna was connected to EUT R-SMA antenna port:

Taoglas ISM 915MHz omni-direction antenna: Parts # IS.05.B.301111 with 3dBi gain.
Specifications available on the web at: https://cdn.taoglas.com/datasheets/IS.05.B.301111.pdf

Testing was performed as EUT was continuously operated at the following frequency channel(s):

Fc= 915MHz




3.2 Special Accessories

N/A

3.3 Configuration of Tested System

Figure 3.1 to Figure 3.3 illustrate this system, which is tested standing along.




———————————————————————————————————————————————
Advanced Compliance Lab, 210 Cougar Court, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927-0728


                                                     10


                    Model No.: CSI-RM650           FCC ID: 2ARIX-CSI-RM650




                                 Figure 3.1 Radiated Test Setup




———————————————————————————————————————————————
Advanced Compliance Lab, 210 Cougar Court, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927-0728


                                                     11


                    Model No.: CSI-RM650           FCC ID: 2ARIX-CSI-RM650




                       Figure 3.2 Radiated Configuration Test Setup


———————————————————————————————————————————————
Advanced Compliance Lab, 210 Cougar Court, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927-0728


                                                     12


                    Model No.: CSI-RM650           FCC ID: 2ARIX-CSI-RM650




                                   Fig. 3.3 Conducted Emission Test Setup


———————————————————————————————————————————————
Advanced Compliance Lab, 210 Cougar Court, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927-0728


                                                     13


                    Model No.: CSI-RM650           FCC ID: 2ARIX-CSI-RM650




4. SYSTEM SCHEMATICS




                                             See Attachment.


                                  Figure 4.1 System Schematics




———————————————————————————————————————————————
Advanced Compliance Lab, 210 Cougar Court, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927-0728


                                                     14


                        Model No.: CSI-RM650                  FCC ID: 2ARIX-CSI-RM650




5. CONDUCTED EMISSION DATA
5.1 Test Methods and Conditions

The EUT was under normal operational mode during the conducted emission test. EMI Receiver
was scanned from 150KHz to 30MHz with maximum hold mode for maximum emission.
Recorded data was sent to the plotter to generate output in linear format. At the input of the
spectrum analyzer, a HP transient limiter is inserted for protective purpose. This limiter has a 10
dB attenuation in the range of 150KHZ to 30MHZ. That factor was automatically compensated by
the receiver, so the readings are the corrected readings. The reference of the plot is the FCC Part 15
limit in Figure 5.1 through Figure 5.2.
                                      Conducted Emission Technical Requirements
                                             CLASS A                                Class B
     Frequency Range               Quasi-Peak          Average           Quasi-Peak                              Average
                                      dBuV              dBuV               dBuV                                   dBuV
      150kHz –0.5MHz               79 (8912uV)       66 (1995uV)            66-56                                 56-46
       0.5MHz-30MHz                73 (4467uV)       60 (1000uV)             ---                                   ---
       0.5MHz- 5MHz                     ---               ---                56                                    46
        5MHz-30MHz                      ---               ---                60                                    50
Emissions that have peak values close to the specification limit (if any) are also measured in the
quasi-peak mode to determine compliance.

5.2 Test Data

Figure 5.1 through Figure 5.4 show the neutral and line conducted emissions for the defined
operation modes (Optional AC/DC adaptor was used for data collection).
                      Highest Data for AC Line Conducted Emissions
Frequency              0.180      0.200       0.600     15.45      0.170                    0.590        15.68        28.31
(MHz)                  (Line)     (Line)      (Line)    (Line)   (Neutral)                (Neutral)    (Neutral)    (Neutral)
Peak Reading           38.69      39.21       33.24     46.64      41.86                    36.63        55.09        37.19
(dBuV)
Average Reading
                                                                                                        17.39
(dBuV*)
Under Limit               Y            Y             Y            Y            Y                Y            Y         Y
* if Peak reading is under the QP / average limit, no need to show its QP/Average level data.

The following conducted test data shows the worst case emissions are still below FCC Part 15
/IECS-003 Class B limits.

Test Personnel:
       Tester Signature:                David Tu                                Date:           07/12/2016

          Typed/Printed Name: David Tu


———————————————————————————————————————————————
Advanced Compliance Lab, 210 Cougar Court, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927-0728


                                                                15


                    Model No.: CSI-RM650           FCC ID: 2ARIX-CSI-RM650




                 Line Conducted Emission 150kHz-30MHz




                                 Figure 5.1 Line Conducted Emission




———————————————————————————————————————————————
Advanced Compliance Lab, 210 Cougar Court, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927-0728


                                                     16


                    Model No.: CSI-RM650           FCC ID: 2ARIX-CSI-RM650




               Neutral Conducted Emission 150 kHz-30 MHz




                               Figure 5.2 Neutral Conducted Emission




———————————————————————————————————————————————
Advanced Compliance Lab, 210 Cougar Court, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927-0728


                                                     17


                    Model No.: CSI-RM650           FCC ID: 2ARIX-CSI-RM650




6. RADIATED EMISSION DATA

6.1 Field Strength Calculation
The corrected field strength is automatically calculated by EMI Receiver using following:
                                FS = RA +AF + CF + AG

where FS: Corrected Field Strength in dBV/m
      RA: Amplitude of EMI Receiver before correction in dBV
      AF: Antenna Factor in dB/m
      CF: Cable Attenuation Factor in dB
      AG: Built-in Preamplifier Gain in dB (Stored in receiver as part of the calibration data)


6.2 Test Methods and Conditions

The initial step in collecting radiated data is a EMI Receiver scan of the measurement range below
30MHz using peak detector and 9KHz IF bandwidth / 30KHz video bandwidth. For the range
30MHz - 1GHz, 100KHz IF bandwidth / 100KHz video bandwidth are used. Both bandwidths are
1MHz for above 1GHz measurement. Frequency range from EUT’s lowest crystal frequency to
10th harmonics of fundamental was investigated.

6.3 Test Data

The following data lists the significant emission frequencies, polarity and position, peak reading of
the EMI Receiver, the FCC limit, and the difference between the peak reading and the limit.
Explanation of the correction and calculation are given in section 5.1.


Test Personnel:


Typed/Printed Name: David Tu                                      Date:     10/30/2018




———————————————————————————————————————————————
Advanced Compliance Lab, 210 Cougar Court, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927-0728


                                                     18


                    Model No.: CSI-RM650           FCC ID: 2ARIX-CSI-RM650




                       Radiated Test Data for 900 Band Transmitter

CH-915MHz & Harmonics

                                               Peak/QP              FCC/IC
         Frequency     Polarity    Antenna Azimuth       Reading           Difference
                                               Reading                3m
                        (V,H)   Height          at 3m     After      Limit
                       Position                   (2)   Correction    (1)
           (MHz)     (Zup,Zdown) (m) (Degree) (dBuV/m) (dBuV/m)(3) (dBuV/m) (dBuV/m)
            915.0         V      1.1   000       93.1                  94      -0.9
           1830.0         V      1.2   020       51.3      46.5        54     -15.3
           2745.0         V      1.1   010       48.2      43.4        54      -7.5
            915.0         H      1.3   340       93.2                  94      -0.8
           1830.0         H      1.1   330       52.4      46.6        54      -7.4
           2745.0         H      1.2   345       49.6      44.8        54      -9.2



(1) The limit for emissions within the 902-928MHz band is 50mV(94dB) per Sec. 15.249.
The limit for its harmonics is 500uV (54dB). Other spurious emissions shall be lower than either
its fundamental by 50dB or the limit defined in Sec. 15.209, whichever is higher.
(2) If each peak reading is less than the FCC average limit, it’ll be not necessary to show the
measured/ calculated average reading. In this case, all peak reading is below the peak limit of
74dBuV/m.
(3) Each max transmission duration is 57.5ms per 30s. So the duty cycle factor within 100ms is
57.5%, i.e, -4.8dB, which can be applied to average reading for harmonics.




———————————————————————————————————————————————
Advanced Compliance Lab, 210 Cougar Court, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927-0728


                                                     19


                    Model No.: CSI-RM650           FCC ID: 2ARIX-CSI-RM650




Other Spurious outside of the band 902-928MHz*

                                               Peak/QP*
Frequency      Polarity    Antenna    Azimuth                  FCC 3m      Difference
                                                Reading
                            Height              at 3m(2)       Limit(1)
  (MHz)(3)     (H or V)      (m)      (Degree) (dBuV/m)       (dBuV/m)      (dBuV/m)
    41.9*         V          1.2        170      30.84           40.0            -9.16
    48.2*         V          1.2        130      32.45           40.0            -7.55
    56.4*         V          1.2        135      30.53           40.0            -9.47
    58.5*         V          1.2        135      31.20           40.0             -8.8
    64.9          V          1.1        135      36.35           40.0            -3.65
    80.2*         V          1.1        150       31.8           40.0             -8.2
   112.9*         V          1.0        170      29.46           43.5           -14.04
   128.6*         V          1.1        180      40.49           43.5            -3.01
   144.7*         V          1.1        180      32.90           43.5            -10.6
   164.5*         V          1.1        180      33.20           43.5            -10.3
   177.9          V          1.1        190      40.05           43.5            -3.45
   204.7*         V          1.1        180      40.70           43.5             -2.8
   704.8*         V          1.2        170      37.18           46.5            -9.32
   713.3*         V          1.1        195      35.03           46.5           -11.47
    48.3*         H          1.4        335      30.38           40.0            -9.62
    57.6          H          1.5        330      34.40           40.0             -5.6
    80.8          H          1.4        350      35.70           40.0             -4.3
   112.5          H          1.3        270      35.11           43.5            -8.39
   146.0          H          1.4        280      33.32           43.5           -10.18
   205.6*         H          1.2        120      41.94           43.5            -1.56
   240.0          H          1.3        140      37.72           46.5            -8.78
   274.1          H          1.3        290      35.93           46.5           -10.57



(1)Comparing to the limit defined in Sec. 15.209, emissions below the limit by 20dB were not
recorded.
(2) If each peak reading is less than the FCC average limit, it’ll be not necessary to show the
measured/ calculated average reading. Emissions with * are QP reading.
(3) Emissions from digital circuitry ( non-intentional radiator ), if any, are excluded.




———————————————————————————————————————————————
Advanced Compliance Lab, 210 Cougar Court, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927-0728


                                                     20


                    Model No.: CSI-RM650           FCC ID: 2ARIX-CSI-RM650




Signal Bandwidth in 900MHz Band

                                         Fundamental Freq : 915MHz




                                           20dB Bandwidth Plot




                                            99% Bandwidth Plot




———————————————————————————————————————————————
Advanced Compliance Lab, 210 Cougar Court, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927-0728


                                                     21


                    Model No.: CSI-RM650           FCC ID: 2ARIX-CSI-RM650




900MHz Band-edge Spurious




        * Max. Peak Reading is 39.59dBuV/m @902MHz with correction factors. It is
        under FCC /IC limit.




        * Max. Peak Reading is 41.35dBuV/m @928.63MHz with correction factors. It is
        under FCC /IC limit.




———————————————————————————————————————————————
Advanced Compliance Lab, 210 Cougar Court, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927-0728


                                                     22


                    Model No.: CSI-RM650           FCC ID: 2ARIX-CSI-RM650




7. EUT RECEIVING MODE VERIFICATION

Radiated Test Data for Receiving Mode

                                               Peak/QP*
Frequency      Polarity    Antenna    Azimuth                  FCC 3m      Difference
                                                Reading
                            Height              at 3m(2)       Limit(1)
  (MHz)(3)     (H or V)      (m)      (Degree) (dBuV/m)       (dBuV/m)      (dBuV/m)
    48.3*         V          1.2        125      31.73           40.0            -8.27
    80.2*         V          1.1        140      30.20           40.0             -9.8
   128.4*         V          1.1        180      40.20           43.5             -3.3
   144.4*         V          1.1        170      33.50           43.5              -10
   166.8*         V          1.1        180      32.90           43.5            -10.6
   205.0*         V          1.1        170      39.49           43.5            -4.01
   706.9*         V          1.2        170      33.18           46.5           -13.32
    48.2*         H          1.4        350      29.12           40.0           -10.88
    80.8          H          1.4        350      33.20           40.0             -6.8
   114.2          H          1.3        270      34.71           43.5            -8.79
   205.6*         H          1.3        130      39.13           43.5            -4.37
   240.7          H          1.3        130      38.17           46.5            -8.33



(1) Receiving mode spurious emissions shall be lower than the limit defined in Sec. 15.209
(2) If each peak reading is less than the FCC average limit, it’ll be not necessary to show the
measured/ calculated average reading. Emissions with * are QP reading.
(3) Emissions from digital circuitry ( non-intentional radiator ) are excluded.




———————————————————————————————————————————————
Advanced Compliance Lab, 210 Cougar Court, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927-0728


                                                     23



Document Created: 2019-04-08 01:27:46
Document Modified: 2019-04-08 01:27:46

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC