RF Exposure

FCC ID: 2ARI5-MP1001

RF Exposure Info

Download: PDF
FCCID_4252329

                      EXPOSURE
                      REPORT

                      FCC ID: 2ARI5-MP1001


                      Date of issue: Apr. 18, 2019

Report Number:        MTi190416E110


Sample Description:   MagPad


Model(s):             MP1001


Applicant:            Shenzhen Lingyi Innovation Tech Co., Ltd.


Address:              12 F, Block C, Central Avenue Building, Xixiang BLVD
                      West, Baoan District, Shenzhen, China.


Date of Test:         Mar. 28, 2019 – Apr. 18, 2019




                      Shenzhen Microtest Co., Ltd.
                         http://www.mtitest.com


                                       Table of Contents

  Applicant’s name:                Shenzhen Lingyi Innovation Tech Co., Ltd.

                                   12 F, Block C, Central Avenue Building, Xixiang BLVD West, Baoan
  Address:
                                   District, Shenzhen, China.

  Manufacture's name:              Shenzhen Lingyi Innovation Tech Co., Ltd.

                                   12 F, Block C, Central Avenue Building, Xixiang BLVD West, Baoan
  Address:
                                   District, Shenzhen, China.

  Product name:                    MagPad

  Trademark:                       Pitaka


  Model name:                      MP1001


  Standard:                        FCC CFR 47 PART 1 , 1.1310


  RF Exposure Procedures:          KDB 680106 D01 RF Exposure Wireless Charging App v03



This device described above has been tested by Shenzhen Microtest Co., Ltd. and the test results
show that the equipment under test (EUT) compliance with the FCC requirements. And it is applicable
only to the tested sample identified in the report.




                      Tested by:


                                       Demi Mu                                 Apr. 18, 2019


                  Reviewed by:


                                       Blue Zheng                              Apr. 18, 2019

                  Approved by:

                                       Smith Chen                              Apr. 18, 2019


1 General Information
1.1 Description of EUT

    Product name:                MagPad

    Trademark:                   Pitaka

    Model name:                  MP1001

    Series model:
                                 N/A

    Deference in serial model:
                                 N/A

    Operation frequency:         115–205 kHz

    Operational mode:            Wireless charging

    Modulation type:             Load modulation

    Antenna type:                Loop antenna

    Power source:                DC 5V or 9V from adapter

    Battery:                     N/A

                                 Model:FC69U
                                 Input:100-240V~50/60Hz 0.8A Max
    Adapter information:
                                 Output: QC:5V-3A 9V-3A 12V-2.5A
                                         PD: 5V-3A 9V-3A 12V-2.5A 15V-2A 20V-1.5A

1.2 Ancillary equipment list
          Equipment                Model                        S/N      Manufacturer

           Adapter                FC69U              KX2018490024444           /

        Mobile phone                   /                         /             /


1.3 Measurement uncertainty
Measurement Uncertainty for a Level of Confidence of 95 %, U=2xUc(y)

     Radiated emission(150kHz~30MHz)                 ± 2.5 dB
     Radiated emission(30MHz~1GHz)                   ± 4.2 dB
     Radiated emission (above 1GHz)                  ± 4.3 dB
     Temperature                                     ±1 degree
     Humidity                                        ±5%


2 Testing site
   Test Site               Shenzhen Microtest Co., Ltd

                           No.102A & 302A, East Block, Hengfang Industrial Park, Xingye
   Test Site Location
                           Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China

   FCC Registration No.:   448573


3 List of test equipment
 Equipment   Equipment                                 Serial   Calibration
                             Manufacturer     Model                           Due date
 No.         Name                                      No.      date

                             Narda Safety
             Broadband                        NBM-
 MTI-E068                    Test Solutions            D-1699   2018/07/13    2019/07/12
             Field Meter                      520
                             GmbH

                             Narda Safety
 MTI-E069    Probe E-Field                    EF0691   H-0571   2018/07/13    2019/07/12
                             Test Solutions


4 Test Results
4.4 Maximum permissible exposure
4.4.1       Limit


   Frequency         Electric field      Magnetic field          Power             Averaging
  range(MHz)         strength(V/m)       strength(A/m)      density(mW/cm2)      time(minutes)

                           (A) Limits for Occupational/Controlled Exposure
       0.3-3.0              614                 1.63                 *100             6
       3.0-30             1842/f               4.89/f               *900/f2           6
       30-300              61.4                0.163                 1.0 6            6
     300-1500                                                        f/300            6
   1500-100000                                                          5             6
                       (B) Limits for General Population/Uncontrolled Exposure
      0.3-1.34              614                 1.63                 *100             30
      1.34-30              824/f               2.19/f               *180/f2           30
       30-300              27.5                0.073                   0.2            30
     300-1500                                                       f/1500            30
   1500-100000                                                          1             30
f = frequency in MHz * = Plane-wave equivalent power density


4.4.2         Test Procedures
E and H-field measurements should be made with the center of the probe at a distance of 15 cm
surrounding the device and 20 cm above the top surface of the primary/client pair.

These measurements should be repeated for three different client battery levels, 1%, 50%, and 99%.

Record the test results.

KDB 680106 D01 RF Exposure Wireless Charging App v03:

(1) Power transfer frequency is less than 1 MHz.

   (Conform) The EUT operates at 115kHz-205kHz

(2) Output power from each primary coil is less than or equal to 15 watts.

   (Conform) The output power is less than 15W in the manual.

(3) The transfer system includes only single primary and secondary coils. This includes charging

systems that may have multiple primary coils and clients that are able to detect and allow

coupling only between individual pairs of coils.

   (Conform) It is confirmed that the sample has only one primary coil and one secondary coil.

(4) Client device is placed directly in contact with the transmitter.

    (Conform) The client is in direct contact with the product to charge

(5) Mobile exposure conditions only (portable exposure conditions are not covered by this

exclusion).

   (Conform) This EUT is compatible with mobile devices

(6) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface

from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit.

(Conform) Please refer to the following test data


4.4.3   Test Setup


                                              Top Side


                                                            Back Side




                     Left Side
                                                                   15cm
                                                                              Field Probe
                                                                 Right Side




                                 Front Side

                                              Bottom Side


4.4.4   Test Result

                              Maximum permissible Exposure
          Battery                             Test
                        Test sides                      E –field(V/m)   H–field(A/m)
          levels                         distance(cm)
           <1%             Top                 20          0.417           0.113
           <1%            Bottom               15          0.421           0.118
           <1%              Left               15          0.427           0.114
           <1%             Right               15          0.421           0.108
           <1%             Front               15          0.411           0.105
           <1%             Back                15          0.412           0.101
                           Limit                             614           1.63

                      Margin Limit (%)                    0.069%          7.06%



                              Maximum permissible Exposure
          Battery                             Test
                        Test sides                      E –field(V/m)   H–field(A/m)
          levels                         distance(cm)
          <50%             Top                 20          0.421           0.128
          <50%            Bottom               15          0.407           0.116
          <50%              Left               15          0.413           0.117
          <50%             Right               15          0.413           0.109
          <50%             Front               15          0.421           0.111
          <50%             Back                15          0.412           0.109
                           Limit                             614           1.63

                      Margin Limit (%)                    0.069%          7.85%



                              Maximum permissible Exposure
          Battery                             Test
                        Test sides                      E –field(V/m)   H–field(A/m)
          levels                         distance(cm)
          <99%             Top                 20          0.433           0.119
          <99%            Bottom               15          0.427           0.104
          <99%              Left               15          0.421           0.105
          <99%             Right               15          0.414           0.107
          <99%             Front               15          0.421           0.112
          <99%             Back                15          0.416           0.105
                           Limit                             614           1.63

                      Margin Limit (%)                    0.071%          7.30%


4.4.5   MPE Setup photo




                          ----END OF REPORT----



Document Created: 2019-04-25 10:50:03