Test Report_NII_5G DFS

FCC ID: 2ARHS-W562

Test Report

Download: PDF
FCCID_4114533

                                                                                               REPORT No.:SZ18100025W07




                                          TEST REPORT

                       APPLICANT                                : Hyco Genyong Technology Co., Ltd.

                       PRODUCT NAME                             : Smart Watch

                       MODEL NAME                               : W562

                       BRAND NAME                               : HYCO

                       FCC ID                                   : 2ARHS-W562

                       STANDARD(S)                              : 47 CFR Part 15 Subpart E

                       TEST DATE                                : 2018-10-18 to 2018-10-20

                       ISSUE DATE                               : 2018-11-07




                                                                        Tested by:
                                                                                               Wang Meng (Test Engineer)


                                                                        Approved by:
                                                                                               Peng Huarui ( Supervisor )



NOTE: This document is issued by MORLAB, the test report shall not be reproduced except in full without prior written permission of the
company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for
validation and information confirmed at our website.


 MORLAB
                         SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
                         FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                         Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn


                                                                                       REPORT No.:SZ18100025W07


                                                     DIRECTORY
1. Technical Information ··················································································· 4
1.1. Applicant and Manufacturer Information ······················································· 4
1.2. Companion Equipment(Master) Description ·················································· 4
1.3. Equipment Under Test (EUT) Description ······················································ 4
1.4. The channel number and frequency of EUT ··················································· 6
1.5. Test Standards and Results ········································································ 7
1.6. Environmental Conditions ·········································································· 7
2. 47 CFR Part 15C Requirements ······································································ 8
2.1. Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) ··········· 8
Annex A The waveform of the radar ·································································· 19
Annex B Test Uncertainty ················································································ 22
Annex C Testing Laboratory Information ··························································· 23




MORLAB
                 SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
                 FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                 Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                     Page 2 of 24


                                                                                  REPORT No.:SZ18100025W07

                                                      Change History
    Issue                                  Date                                     Reason for change
     1.0                              2018-11-07                                            First edition




MORLAB
            SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
            FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
            Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                Page 3 of 24


                                                                                     REPORT No.:SZ18100025W07

1. Technical Information
Note: Provide by applicant.


1.1. Applicant and Manufacturer Information

 Applicant:                             Hyco Genyong Technology Co., Ltd.
 Applicant Address:                     Room 105, 1/F, Building B, No.999 of Huaxu Road, Qingpu
                                        District, Shanghai, CN
 Manufacturer:                          HYCO Information Technology Co., Ltd
 Manufacturer Address:                  Room 3A07, Tower B, North Zone, No.999, Huaxu Road, Qingpu
                                        District, Shanghai, CN


1.2. Companion Equipment(Master) Description

 Product Name:                                 Router
 Manufacturer:                                 Cisco
 FCC ID:                                       LDK102091
 Serial No:                                    FGL1848X9S5
 Antenna Gain:                                 2.1 dBi


1.3. Equipment Under Test (EUT) Description

 Product Name:                                 Smart Watch
 Serial No:                                    (N/A, marked #1 by test site)
 Hardware Version:                             W562_V1.2
 Software Version:                             W562-FL_6.0_20180625_1408
 Modulation Type:                              OFDM
 Modulation Mode:                              802.11a, 802.11n(HT20), 802.11n(HT40)
                                               5.180 GHz- 5.240 GHz; 5.260 GHz -5.320 GHz ;
 Operating Frequency Range:
                                               5.745GHz- 5.825GHz
 Channel Number:                               Refer to 1.3
 Antenna Type:                                 FPC Antenna
 Antenna Gain:                                 -0.23 dBi




MORLAB
               SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
               FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
               Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                   Page 4 of 24


    Cll
                                                                                   REPORT No.: $218100025W07

                                              Battery
                                              Brand Name:                                   HYCO
                                              Model No.:                                   964G55P
                                              Serial No.:                                   (N/A, marked #1 by test site)
                                              Capacity:                                    3600mAh
                                               Rated Voltage:                              3.8V
                                              Charge Limit:                                4.35V
                                              AC Adapter 1
                                              Brand Name:                                  AOHAI
 Accessory Information:                       Model No.:                                   A18A—050100U—US2
                                              Serial No.:                                   (N/A, marked #1 by test site)
                                               Rated Input:                                ~ 100—240V, 50/60H2z, 0.2A
                                               Rated Output:                                =65V, 1A
                                              AC Adapter 2
                                              Brand Name:                                   N/A
                                              Model No.:                                    UT—146A—5100
                                              Serial No.:                                   (N/A, marked #1 by test site)
                                               Rated Input:                                ~ 100—240V, 50/60H2z, 0.15A
                                               Rated Output:                                =5V, 1A
Note 1: The EUT has two adaptors, both of the two adaptors were tested, only the worst test
result(Adapter1) were recorded in the test report.
Note 2: For a more detailed description, please refer to Specification or User‘s Manual supplied by
the applicant and/or manufacturer.




                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                Tel: 86—755—36608555   Fax: 86—755—36808525
M o R LA B      FL1—3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Bock7, BaoAn Distrct, ShenZhen , GuangDong Province, P. R. China   Hitp?/wen.mortab.on    E—mail: service@morlab.on

                                                                                                                                  Page 5 of 24


                                                                                      REPORT No.:SZ18100025W07

1.4. The channel number and frequency of EUT

 Frequency Range: 5180MHz-5240MHz
    Bandwidth              Channel                   Frequency (MHz)                  Channel                Frequency (MHz)
                                36                              5180                       40                          5200
     20MHz
                                44                              5220                       48                          5240
     40MHz                      38                              5190                       46                          5230
 Frequency Range: 5260MHz-5320MHz
    Bandwidth              Channel                   Frequency (MHz)                  Channel                Frequency (MHz)
                                52                              5260                       56                          5280
     20MHz
                                60                              5300                       64                          5320
     40MHz                      54                              5270                       62                          5310
 Frequency Range: 5745-5825MHz
    Bandwidth              Channel                   Frequency (MHz)                  Channel                Frequency (MHz)
                               149                              5745                      153                          5765
     20MHz                     157                              5785                      161                          5805
                               165                              5825
     40MHz                     151                              5775                      159                          5795
Note 1: The black bold channels were selected for test.




MORLAB
                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                    Page 6 of 24


                                                                                        REPORT No.:SZ18100025W07

1.5. Test Standards and Results

The objective of the report is to perform testing according to 47 CFR Part 15 Subpart E (U-NII band)
for the EUT FCC ID Certification:
 No    Identity                                                         Document Title
 1     47 CFR Part 15 (5-1-14 Edition)                                  Radio Frequency Devices


Test detailed items/section required by FCC rules and results are as below:
 No.   Section                Description                                      Test Date            Test Engineer                 Result
 1     15.407(h)              TPC and DFS                                    Oct 19, 2018               Tu Ya’nan                  PASS
 Note2: The DFS section for U-NII band is applicable to this report, the other test items are
        documented in a separate report.
 Note3: These RF tests were performed according to the method of measurements prescribed in
        KDB 905462 D02 UNII DFS Compliance Procedures New Rules v02.


1.6. Environmental Conditions

During the measurement, the environmental conditions were within the listed ranges:

 Temperature (°C):                                              15 - 35
 Relative Humidity (%):                                         30 -60
 Atmospheric Pressure (kPa):                                    86-106




MORLAB
                  SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
                  FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                  Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                      Page 7 of 24


                                                                                          REPORT No.:SZ18100025W07

2. 47 CFR Part 15C Requirements
2.1. Transmit Power Control (TPC) and Dynamic Frequency
     Selection (DFS)

2.1.1. Requirement

According to FCC section 15.407(h), (1) Transmit power control (TPC). U-NII devices operating in
the 5.25-5.35 GHz band and the 5.47-5.725 GHz band shall employ a TPC mechanism. The U-NII
device is required to have the capability to operate at least 6 dB below the mean EIRP value of 30
dBm. A TPC mechanism is not required for systems with an e.i.r.p. of less than 500 mW.(2) Radar
Detection Function of Dynamic Frequency Selection (DFS). U-NII devices operating with any part
of its 26 dB emission bandwidth in the 5.25-5.35 GHz and 5.47-5.725 GHz bands shall employ a
DFS radar detection mechanism to detect the presence of radar systems and to avoid co-channel
operation with radar systems. Operators shall only use equipment with a DFS mechanism that is
turned on when operating in these bands. The device must sense for radar signals at 100 percent
of its emission bandwidth. The minimum DFS detection threshold for devices with a maximum
e.i.r.p. of 200 mW to 1 W is −64 dBm. For devices that operate with less than 200 mW e.i.r.p. and a
power spectral density of less than 10 dBm in a 1 MHz band, the minimum detection threshold is
−62 dBm. The detection threshold is the received power averaged over 1 microsecond referenced
to a 0 dBi antenna. For the initial channel setting, the manufacturers shall be permitted to provide
for either random channel selection or manual channel selection.
A U-NII network will employ a DFS function to detect signals from radar systems and to avoid
co-channel operation with these systems. This applies to the 5250-5350 MHz and/or 5470-5725
MHz bands.1
Within the context of the operation of the DFS function, a U-NII device will operate in either Master
Mode or Client Mode. U-NII devices operating in Client Mode can only operate in a network
controlled by a U-NII device operating in Master Mode.2
Tables 1 and 2 shown below summarize the information contained in sections 5.1.1 and 5.1.2.
              Table 1: Applicability of DFS Requirements Prior to Use of a Channel
                                                                                       Operational Mode
           Requirement                                                      Client Without Radar                  Client With Radar
                                                       Master
                                                                                  Detection                           Detection
       Non-Occupancy Period                               Yes                         Not required                            Yes
      DFS Detection Threshold                             Yes                         Not required                            Yes
  Channel Availability Check Time                         Yes                         Not required                     Not required
     U-NII Detection Bandwidth                            Yes                         Not required                            Yes




MORLAB
                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                        Tel: 86-755-36698555   Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China        Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                         Page 8 of 24


                                                                                         REPORT No.:SZ18100025W07

             Table 2: Applicability of DFS requirements during normal operation
                                                                                         Operational Mode
               Requirement
                                                                       Master            Client Without Radar Detection
         DFS Detection Threshold                                          Yes                             Not required
   Channel Closing Transmission Time                                      Yes                                    Yes
           Channel Move Time                                              Yes                                    Yes
        U-NII Detection Bandwidth                                         Yes                             Not required


    Additional requirements for
                                                            Master Device or Client                        Client Without Radar
      devices with multiple
                                                             with Radar Detection                                Detection
        bandwidth modes
   U-NII Detection Bandwidth and
                                                        All BW modes must be tested                              Not required
   Statistical Performance Check
 Channel Move Time and Channel                          Test using widest BW mode                      Test using the widest BW
   Closing Transmission Time                            available                                      mode available for the link
 All other tests                                               Any single BW mode                                Not required
 Note: Frequencies selected for statistical performance check (Section 7.8.4) should include
 several frequencies within the radar detection bandwidth and frequencies near the edge of the
 radar detection bandwidth. For 802.11 devices it is suggested to select frequencies in each of
 the bonded 20 MHz channels and the channel center frequency.
The operational behavior and individual DFS requirements that are associated with these modes
are as follows:
                                         Master Devices
a) The Master Device will use DFS in order to detect Radar Waveforms with received signal
strength above the DFS Detection Threshold in the 5250 − 5350 MHz and 5470 − 5725 MHz bands.
DFS is not required in the 5150 − 5250 MHz or 5725 − 5825 MHz bands.
b) Before initiating a network on a Channel, the Master Device will perform a Channel Availability
Check for specified time duration (Channel Availability Check Time) to ensure that there is no radar
system operating on the Channel, using DFS described under subsection a) above.
c) The Master Device initiates a U-NII network by transmitting control signals that will enable other
U-NII devices to Associate with the Master Device.
d) During normal operation, the Master Device will monitor the Channel (In-Service Monitoring) to
ensure that there is no radar system operating on the Channel, using DFS described under a).
e) If the Master Device has detected a Radar Waveform during In-Service Monitoring as described
under d), the Operating Channel of the U-NII network is no longer an Available Channel. The
Master Device will instruct all associated Client Device(s) to stop transmitting on this Channel
within the Channel Move Time. The transmissions during the Channel Move Time will be limited to
the Channel Closing Transmission Time.



MORLAB
                   SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                    Tel: 86-755-36698555    Fax: 86-755-36698525
                   FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                   Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China    Http://www.morlab.cn    E-mail: service@morlab.cn

                                                                                                                                         Page 9 of 24


                                                                                      REPORT No.:SZ18100025W07

f) Once the Master Device has detected a Radar Waveform it will not utilize the Channel for the
duration of the Non-Occupancy Period. 3
g) If the Master Device delegates the In-Service Monitoring to a Client Device, then the
combination will be tested to the requirements described under d) through f) above.
                                            Client Devices
a) A Client Device will not transmit before having received appropriate control signals from a
Master Device.
b) A Client Device will stop all its transmissions whenever instructed by a Master Device to which it
is associated and will meet the Channel Move Time and Channel Closing Transmission Time
requirements. The Client Device will not resume any transmissions until it has again received
control signals from a Master Device.
c) If a Client Device is performing In-Service Monitoring and detects a Radar Waveform above the
DFS Detection Threshold, it will inform the Master Device. This is equivalent to the Master Device
detecting the Radar Waveform and d) through f) of section 5.1.1 apply.
d) Irrespective of Client Device or Master Device detection the Channel Move Time and Channel
Closing Transmission Time requirements remain the same.
e) The client test frequency must be monitored to ensure no transmission of any type has occurred
for 30 minutes. Note: If the client moves with the master, the device is considered compliant if
nothing appears in the client non-occupancy period test. For devices that shut down (rather than
moving channels), no beacons should appear.
                                      DFS Detection Thresholds
Table 3 below provides the DFS Detection Thresholds for Master Devices as well as Client
Devices incorporating In-Service Monitoring.
 Table 3: DFS Detection Thresholds for Master Devices and Client Devices with Radar
                                               Detection
Maximum Transmit Power                                             Value (See Notes 1, 2, and 3)
EIRP ≥ 200 milliwatt                                               -64 dBm
EIRP < 200 milliwatt and
                                                                   -62 dBm
power spectral density < 10 dBm/MHz
EIRP < 200 milliwatt that do not meet the power spectral
                                                                   -64 dBm
density requirement
Note 1: This is the level at the input of the receiver assuming a 0 dBi receive antenna.
Note 2: Throughout these test procedures an additional 1 dB has been added to the amplitude of
the test transmission waveforms to account for variations in measurement equipment. This will
ensure that the test signal is at or above the detection threshold level to trigger a DFS response.
Note3: EIRP is based on the highest antenna gain. For MIMO devices refer to KDB Publication
662911 D01.




MORLAB
                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                    Page 10 of 24


     ORLAB,
     '                                                                                          REPORT No.: $Z18100025WO7

                                                            Response Requirements
Table 4 provides the response requirements for Master and Client Devices incorporating DFS.
                                       Table 4: DFS Response Requirement Values
 Parameter                                                                    Value
 Non—occupancy period                                                Minimum 30 minutes
 Channel Availability Check Time                                     60 seconds
 Channel Move Time                                                   10 seconds
                                                                     See Note 1.
 Channel Closing Transmission Time                                   200 milliseconds + an aggregate of 60 milliseconds
                                                                     over remaining 10 second period. See Notes 1 and 2.
 U—NII Detection Bandwidth                                           Minimum 100% of the U—NII 99% transmission power
                                                                     bandwidth. See Note 3.
 Note 1: Channel Move Time and the Channel Closing Transmission Time should be performed
 with Radar Type 0. The measurement timing begins at the end of the Radar Type 0 burst.
 Note 2: The Channel Closing Transmission Time is comprised of 200 milliseconds starting at
 the beginning of the Channel Move Time plus any additional intermittent control signals required
 to facilitate a Channel move (an aggregate of 60 milliseconds) during the remainder of the 10
 second period. The aggregate duration of control signals will not count quiet periods in between
 transmissions.
 Note 3: During the U—NII Detection Bandwidth detection test, radar type 0 should be used. For
 each frequency step the minimum percentage of detection is 90 percent. Measurements are
 performed with no data traffic.


2.1.2. Test Description


According to Section 7.2 of KDB 905462 DO2 VO1RO1
1. Setup for Master with injection at the Master

  Radar Test
  Signal Generator
                        Oumth



                             L‘wl* Splitter!
                                    2wey                                                       2—Way                                  uUT
                                                        Combiner                               CS;L'::;F; O (Master)


 Spectrum
 Analyzer                                                        i
 (with 10 dB internal                                         chent
 Attenuation)     0                                                       O


(Example Conducted Setup where UUT is a Master and Radar Test Waveforms are injected into
the Master)


                         SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                    Tel: 86—755—36c00555   Fax: 86—755—36600525
MORL AB                  512. Buteing AFeivang Science Par, No.8 LongChang Road,
                         Block67, BacAn District, Shenzhen , GuangDong Province, P. R. China    Hitp://www.morlab.on   E—mail service@morkb.cn

                                                                                                                                              Page 11 of 24


                                                                                                REPORT No.: $Z18100025W07

2. Setup for Client with injection at the Master
  Radar Test                                                                                                                        ho
  Signal Generator                                                                                                                          Master
                        Output Q                                                                                       a
                                                                                                                       E
                                       ATT 104B                2—Way                                 2—Way
                                                              Splitter‘                             Splitter/
                                     | ATT 30 0B   !        Combiner                               Combiner


                  O                                                                                                                  O       Spectrum
       UUT                                                                                                                                    Analyzer
     (Client)                                                                                                                        (with 10 dB internal
                                                                                                                                            Aftenuation}


(Example Conducted Setup where UUT is a Client and Radar Test Waveforms are injected into the
Master)
3. Setup for Client with injection at the Client
  Radar Test
  Signal Generator
                        Ouput


                                     ATT 10 0B             2—Way
                                                          Splitter/
                                                         Combiner
                                                                        k——Laxz=]—                2—Way
                                                                                                 Splitter/
                                                                                                                                               uUuT
                                                                                                                                      1O —(Client)
                                                                                                Combiner
                                                                                        |_z#]




 Spectrum
 Analyzer
 (with 10 dB internal
                                                                Master
 Aftenuation)     0                                                          O

(Example Conducted Setup where UUT is a Client and Radar Test Waveforms are injected into the
Client)




                         SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                    Tel: 86—755—36608555       Fax: 86—755—36600525
MORLAB                   FL1—3, Bulding A, FeiYang Science Park, No.8 LongChang Road,
                         Block§7, BaoAn District, ShenZhen , GuangDong Province, P. R. China    Hitpuiwaw.morlab.on        E—mail: service@morlab.on

                                                                                                                                                  Page 12 of 24


                                                                                    REPORT No.:SZ18100025W07

2.1.3. Test Result

a. Test sequence and Channel loading between Master and Client
        Test Channel                                   Frequency(MHz)                                      Payload
             62                                                  5310                                       40.13%




                                                        (Test sequence)




                                                              (Payload)



MORLAB
              SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
              FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
              Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                  Page 13 of 24


                                                                                     REPORT No.:SZ18100025W07

b. Radar Test Waveforms are injected into the Master:




c. EUT is a Client Device Without Radar Detection :
                                                                     Operational
   Channel &                                                           Mode                  Test
                             Requirement                                                                    Limit            Verdict
   Bandwidth                                                      Client Without            Result
                                                                 Radar Detection
                        Channel Move Time                                    Yes             0.63s          <10s               PASS
 802.11 n(HT40)
                          Channel Closing
   5230MHz                                                                   Yes            0.002s          <1s                PASS
                         Transmission Time
                        Channel Move Time                                    Yes             0.62s          <10s               PASS
 802.11 n(HT40)
                          Channel Closing
   5310MHz                                                                   Yes            0.003s          <1s                PASS
                         Transmission Time




MORLAB
               SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
               FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
               Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                   Page 14 of 24


                                                                                     REPORT No.:SZ18100025W07

Test Plots
Note: T0 denotes the start time of the Radar single transmitted, T1 denotes the end time of the
Radar single transmit end. T2 denotes the data transmission time of 200ms from T1. T3 denotes
the end of the Channel Move Time, the time of T3 from T1 is less than 12s.




                                                (5230MHz, 802.11n (HT40))




                                               (5310MHz, 802.11n (HT40))



MORLAB
               SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
               FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
               Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                   Page 15 of 24


                                                                                       REPORT No.:SZ18100025W07

d. Time per bin
       Channel                                  Frequency (MHz)                                      Time Per Bin (ms)
            46                                             5230                                               0.50
            62                                             5310                                               0.50


Test Plot




                                                  (5230MHz, 802.11n (HT40))




MORLAB
                 SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
                 FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                 Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                     Page 16 of 24


                                                                               REPORT No.:SZ18100025W07




                                         (5310MHz, 802.11n (HT40))




MORLAB
         SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
         FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
         Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                             Page 17 of 24


                                                                                     REPORT No.:SZ18100025W07

e. verification of Non-occupancy time
The sweep time is 2.1ks(35min) which is able to meet the requirements of Non-occupancy time.

     Channel & Bandwidth                               Test Result                       Limit                         Verdict

        802.11 n (HT40)
                                                            35min                      ≥30min                            PASS
           5270MHz




                            (Non-occupancy time, 5270MHz, 802.11n (HT40))




MORLAB
               SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
               FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
               Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                   Page 18 of 24


                                                                               REPORT No.:SZ18100025W07

Annex A The waveform of the radar




                                                          (Type 0)




                                                          (Type 1)




MORLAB
         SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
         FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
         Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                             Page 19 of 24


                                                                               REPORT No.:SZ18100025W07




                                                          (Type 2)




                                                          (Type 3)




MORLAB
         SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
         FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
         Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                             Page 20 of 24


                                                                               REPORT No.:SZ18100025W07




                                                          (Type 4)




                                                          (Type 5)




MORLAB
         SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
         FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
         Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                             Page 21 of 24


                                                                                      REPORT No.:SZ18100025W07

Annex B Test Uncertainty
Where relevant, the following measurement uncertainty levels have been estimated for test
performed on the EUT as specified in CISPR 16-1-2:
 Test items                                                                 Uncertainty
 Bandwidth                                                                  ±5%
 Conducted Emission                                                         ±2.44dB
This uncertainty represent an expanded uncertainty expressed at approximately the 95%
confidence level using a coverage factor of k=2




MORLAB
              SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                     Tel: 86-755-36698555   Fax: 86-755-36698525
              FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
              Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China     Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                    Page 22 of 24


                                                                                     REPORT No.:SZ18100025W07

Annex C Testing Laboratory Information
1. Identification of the Responsible Testing Laboratory

 Company Name:                                Shenzhen Morlab Communications Technology Co., Ltd.
 Department:                                  Morlab Laboratory
 Address:                                     FL.3, Building A, FeiYang Science Park, No.8 LongChang
                                              Road, Block 67, BaoAn District, ShenZhen, GuangDong
                                              Province, P. R. China
 Responsible Test Lab
                                              Mr. Su Feng
 Manager:
 Telephone:                                   +86 755 36698555
 Facsimile:                                   +86 755 36698525

2. Identification of the Responsible Testing Location

                                               Shenzhen Morlab Communications Technology Co., Ltd.
 Name:
                                               Morlab Laboratory
                                               FL.3, Building A, FeiYang Science Park, No.8 LongChang
 Address:                                      Road, Block 67, BaoAn District, ShenZhen, GuangDong
                                               Province, P. R. China

3. Facilities and Accreditations

All measurement facilities used to collect the measurement data are located at FL.3, Building A,
FeiYang Science Park, Block 67, BaoAn District, Shenzhen, 518101 P. R. China. The test site is
constructed in conformance with the requirements of ANSI C63.10-2013 and CISPR Publication 22;
the FCC designation number is CN1192, the test firm registration number is 226174.




MORLAB
               SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
               FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
               Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                   Page 23 of 24


                                                                                          REPORT No.:SZ18100025W07

4. Test Equipments Utilized

4.1 Conducted Test Equipments
 Equipment Name               Serial No.                     Type               Manufacturer                Cal. Date              Cal. Due
   Power Splitter                NW521                      1506A                     Weinschel           2018.04.17              2019.04.16
    Attenuator 1                  (N/A.)                     10dB                      Resnet             2018.04.17              2019.04.16
    Attenuator 2                  (N/A.)                      3dB                      Resnet             2018.04.17              2019.04.16
   EXA Signal
                            MY53470836                     N9010A                      Agilent            2017.12.03              2018.12.02
    Analzyer
 MXG Vector Signal
                                Angilent                   N5182B                MY53050961               2018.04.17              2019.04.16
    Generator
     RF cable
                                   CB01                      RF01                      Morlab                     N/A                   N/A
  (30MHz-26GHz)
   Coaxial cable                   CB02                      RF02                      Morlab                     N/A                   N/A
                                                                                      HUBER-
  SMA connector                   CN01                       RF03                                                 N/A                   N/A
                                                                                      SUHNER

4.2Auxiliary Test Equipment
 Equipment Name              Model No.                Brand Name                  Manufacturer               Cal.Date              Cal. Due
     Computer                     T430i                  Think Pad                      Lenovo                    N/A                   N/A


                                                         END OF REPORT




MORLAB
                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                        Tel: 86-755-36698555     Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China        Http://www.morlab.cn     E-mail: service@morlab.cn

                                                                                                                                           Page 24 of 24



Document Created: 2019-09-22 12:31:09
Document Modified: 2019-09-22 12:31:09

© 2024 FCC.report