                                                                                               REPORT No.:SZ18100025S03




                                            RF EXPOSURE
                         EVALUATION REPORT
          APPLICANT                           : Hyco Genyong Technology Co., Ltd.

          PRODUCT NAME                        : Ring scanner charging cradle

          MODEL NAME                          : W2X-RS232 / W2X-USB / W2X-PS2

          BRAND NAME                          : HYCO

          FCC ID                              : 2ARHS-W2X
          STANDARD(S)                         : 47CFR 2.1091
                                                KDB 447498
          ISSUE DATE                          : 2018-11-07




                                                                      Reviewed by:
                                                                                               Gan yueming (Reviewer)



                                                                      Approved by:
                                                                                               Peng Huarui (Supervisor)




NOTE: This document is issued by MORLAB, the test report shall not be reproduced except in full without prior written permission of the
company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for
validation and information confirmed at our website.

                         SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                    Tel: 86-755-36698555   Fax: 86-755-36698525
 MORLAB                  FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                         Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China    Http://www.morlab.cn   E-mail: service@morlab.cn


                                                                                            REPORT No.:SZ18100025S03

                                                          DIRECTORY

1. Technical Information................................................................................................................ 3
1.1 Applicant and Manufacturer Information............................................................................3
1.2 Equipment Under Test (EUT) Description.......................................................................... 3
1.3 Photographs of the EUT..........................................................................................................4
1.4 Applied Reference Documents..............................................................................................5
2. Device Category and RF Exposure Limit..............................................................................6
3. Measurement of RF Output Power......................................................................................... 7
4. RF Exposure Evaluation............................................................................................................7
Annex A General Information....................................................................................................... 8




          Version No.                                       Date                                            Description
                1.0                                    2018-11-07                                                  Original




                                                                      Tested By
         Test engineer:                                              Su Jinhai




                      SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555       Fax: 86-755-36698525
MORLAB                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                      Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn       E-mail: service@morlab.cn

                                                                                                                                              Page2 of 8


                                                                                      REPORT No.:SZ18100025S03



1. Technical Information
    Note: Provide by manufacturer.

1.1 Applicant and Manufacturer Information

  Applicant:                             Hyco Genyong Technology Co., Ltd.
                                         Room 105, 1/F, Building B, No.999 of Huaxu Road, Qingpu
  Applicant Address:
                                         District, Shanghai, CN
  Manufacturer:                          HYCO Information Technology Co., Ltd
                                         Room 3A07, Tower B, North Zone, No.999, Huaxu Road, Qingpu
  Manufacturer Address:
                                         District, Shanghai

1.2 Equipment Under Test (EUT) Description

 EUT Type:                              Ring scanner charging cradle
 Hardware Version:                      V3
 Software Version:                      Charger 1.01.03
 Frequency Bands:                       Bluetooth: 2402 MHz ~2480 MHz
 Modulation Mode:                       BLE: GFSK
 Antenna Type:                          PCB Antenna
 Antenna Gain:                          -0.5dBi
Note:
1. W2X-RS232 --- W2X-RS232 used with U5(RS232 Transceiver) \R22\R23\C7\C31
\C32\C33\C34, without R4\R5\R10\R11\R13\R39\R40\R41\R42\C22\C23\VD1\ VD2\ VD4;
 for communication with the other RS232 device.
2. W2X-USB --- with R4\R5\R10\R11\R13\C22\C23\VD1\VD2\VD4, without U5\R22\
R23\R39\R40\R41\R42\C7\C31\C32\C33\C34; for communication with the other USB device.
3. W2X-PS2 --- with R39\R40\R41\R42\VD1\VD2, without U5\R4\R5\R10\R11\R13\R22\
R23\C7\C22\C23\C31\C32\C33\C34\VD4; for communication with the other PS2 device.
4. The rest are the same, all of these three series, the RF specification were no difference.




                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
MORLAB          FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                    Page3 of 8


                                                                                     REPORT No.:SZ18100025S03



1.3 Photographs of the EUT
1.   EUT Front View




2.   EUT Back View




               SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
MORLAB         FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
               Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                   Page4 of 8


                                                                                         REPORT No.:SZ18100025S03




1.3.1 Identification of all used EUT

The EUT identity consists of numerical and letter characters, the letter character indicates the test
sample, and the following two numerical characters indicate the software version of the test sample.

          EUT Identity              Hardware Version                                     Software Version
               1#                                V3                                       Charger 1.01.03




1.4 Applied Reference Documents
Leading reference documents for testing:
 No.            Identity                                                              Document Title
  1      47 CFR§2.1091                       Radio frequency Radiation Exposure Evaluation: mobile devices
  2      KDB 447498 D01v06                   General RF Exposure Guidance




                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                      Tel: 86-755-36698555   Fax: 86-755-36698525
MORLAB          FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China      Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                       Page5 of 8


                                                                                        REPORT No.:SZ18100025S03



2. Device Category and RF Exposure Limit
Per user manual, Based on 47CFR 2.1091, this device belongs to mobile device category with
General Population/Uncontrolled exposure.
Mobile Devices:
47CFR 2.1091(b)
For purposes of this section, a mobile device is defined as a transmitting device designed to be
used in other than fixed locations and to generally be used in such a way that a separation distance
of at least 20 centimeters is normally maintained between the transmitter's radiating structure(s)
and the body of the user or nearby persons. In this context, the term “fixed location” means that the
device is physically secured at one location and is not able to be easily moved to another location.
Transmitting devices designed to be used by consumers or workers that can be easily re-located,
such as wireless devices associated with a personal computer, are considered to be mobile devices
if they meet the 20 centimeter separation requirement.
GENERAL POPULATION / UNCONTROLLED EXPOSURE
The general population/uncontrolled exposure limits are applicable to situations in which the
general public may be exposed or in which persons who are exposed as a consequence of their
employment may not be made fully aware of the potential for exposure or cannot exercise control
over their exposure. Members of the general public would come under this category when exposure
is not employment-related; for example, in the case of a wireless transmitter that exposes persons
in its vicinity. Warning labels placed on low-power consumer devices such as cellular telephones
are not considered sufficient to allow the device to be considered under the occupational/controlled
category, and the general population/uncontrolled exposure limits apply to these devices.
                       TABLE 1—LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)

      Frequency                 Electric field                       Magnetic field                Power               Averaging
        range                     strength                             strength                   density                time
        (MHz)                       (V/m)                               (A/m)                    (mW/cm2)              (minutes)

                      (B) Limits for General Population/Uncontrolled Exposure

       0.3-1.34                         614                                   1.63                   *(100)                   30

        1.34-30                        824/f                                 2.19/f                *(180/f2)                  30

        30-300                         27.5                                  0.073                     0.2                    30

       300-1500                            -                                     -                  f/1500                    30

    1500-100,000                           -                                     -                     1.0                    30
    f = frequency in MHz                                          * = Plane-wave equivalent power density


                  SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
MORLAB            FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                  Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                      Page6 of 8


                                                                                                REPORT No.:SZ18100025S03



3. Measurement of RF Output Power
<Bluetooth Conducted Power>


                                                         Frequency                            Peak power (dBm)
                    Mode              Channel
                                                             (MHz)                                   GFSK
                                       CH 00                  2402                                   -0.023
                     LE                CH 19                  2440                                   -0.147
                                       CH 39                  2480                                   -0.486
                            Tune-up Limit (dBm)                                                       0.000




4. RF Exposure Evaluation
Standalone transmission MPE evaluation
                                                         Maximum                   Antenna                              Power              Limit for
                              Frequency                                                               EIRP
         Bands                                        Tune-up Limit                   Gain                              density                MPE
                                 (MHz)                                                                (mW)
                                                            (dBm)                     (dBi)                            (mW/cm²)          (mW/cm²)
        Bluetooth                 2402                       0.00                     -0.50            0.89              0.00                   1.0
Note:
1. MPE calculation method
                          Power Density = EIRP/4πR²
  Where: EIRP = P+G
            P = Output Power (dBm)
            G = Antenna Gain (dBi)
            R = Separation Distance (20cm)




                    SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                         Tel: 86-755-36698555    Fax: 86-755-36698525
MORLAB              FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                    Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China         Http://www.morlab.cn    E-mail: service@morlab.cn

                                                                                                                                               Page7 of 8


                                                                                      REPORT No.:SZ18100025S03



                        Annex A General Information
1. Identification of the Responsible Testing Laboratory
  Company Name:                                      Shenzhen Morlab Communications Technology Co., Ltd.
  Department:                                        Morlab Laboratory
  Address:                                           FL.3, Building A, FeiYang Science Park, No.8 LongChang Road,
                                                     Block 67, BaoAn District, ShenZhen, GuangDong Province, P.
                                                     R. China
  Responsible Test Lab Manager:                      Mr. Su Feng
  Telephone:                                         +86 755 36698555
  Facsimile:                                         +86 755 36698525


2. Identification of the Responsible Testing Location
  Name:                                              Shenzhen Morlab Communications Technology Co., Ltd.
                                                     Morlab Laboratory
  Address:                                           FL.3, Building A, FeiYang Science Park, No.8 LongChang Road,
                                                     Block 67, BaoAn District, ShenZhen, GuangDong Province, P.
                                                     R. China




                                                         END OF REPORT




                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
MORLAB          FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                    Page8 of 8



Document Created: 2019-04-17 00:47:22
Document Modified: 2019-04-17 00:47:22

© 2024 FCC.report