MPE Report_rev01

FCC ID: 2ARH7-SG-001-19

RF Exposure Info

Download: PDF
FCCID_4465736

                     Test Report No.: FS190730N036



                                   RF EXPOSURE REPORT
   Applicant                       ShadowTrack Technologies, Inc.

                                   Cypress Bend Office Building, 1001 Ochsner Blvd Suite 425A, Covington, LA.
   Address
                                   70433, USA


   Manufacturer or
                                   Shenzhen Xexun Technology Co.,Ltd
   Supplier
                                   F/7, Guangrong Building, MeiHua Rd., ShangMei lin, FuTian District, ShenZhen,
   Address
                                   China

   Product                         WIRELESS CHARGER

   Brand Name                      SHADOWTRACK

   Model                           ShadoWatch WLC00119

   Additional Model &
                                   N/A
   Model Difference

   Date of tests                   Jul. 30, 2019 ~ Sep. 06, 2019

        47 CFR PART 1, Subpart I, Section 1.1310
        KDB 680106 D01


   CONCLUSION: The submitted sample was found to COMPLY with the test requirement

                       Tested by Breeze Jiang                                                          Approved by Glyn He
                 Project Engineer / EMC Department                                                  Supervisor/ EMC Department




                                                                                                           Date: Sep. 09, 2019
   This report is governed by, and incorporates by reference, CPS Conditions of Service as posted at the date of issuance of this report at
   http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/and is intended for your exclusive use. Any copying or
   replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This
   report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or
   representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and
   expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us.
   Measurement uncertainty is only provided upon request for accredited tests. You have 60 days from date of issuance of this report to notify us of any
   material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing
   and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute you unqualified
   acceptance of the completeness of this report, the tests conducted and the correctness of the report contents.




                                                    No. 34, Chenwulu Section, Guantai Rd., Houjie              Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                                    Town, Dongguan City,                                       Fax: +86 769 8593 1080
Dongguan Branch
                                                    Guangdong 523942, China                                    Email: customerservice.dg@cn.bureauveritas.com
                                                                         Page 1 of 8                                                             Report Version 1


                     Test Report No.: FS190730N036




                                             TABLE OF CONTENTS
   RELEASE CONTROL RECORD ............................................................................................................ 3

   1.     CERTIFICATION .............................................................................................................................. 4

   2.     DESCRIPTION OF SUPPORT UNITS ............................................................................................ 5

   3.     EQUIPMENTS USED DURING TEST ............................................................................................. 5

   4.     TEST RESULTS ............................................................................................................................... 6

        4.1   RF EXPOSURE TEST ................................................................................................................ 6

              4.1.1      EUT OPERATION ........................................................................................................... 6

              4.1.2      MEASUREMENT DATA .................................................................................................. 7

   5.     PHOTOGRAPHS OF THE TEST CONFIGURATION ..................................................................... 8




                                                    No. 34, Chenwulu Section, Guantai Rd., Houjie              Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                                    Town, Dongguan City,                                       Fax: +86 769 8593 1080
Dongguan Branch
                                                    Guangdong 523942, China                                    Email: customerservice.dg@cn.bureauveritas.com
                                                                          Page 2 of 8                                                            Report Version 1


                 Test Report No.: FS190730N036



                               RELEASE CONTROL RECORD

    ISSUE NO.                REASON FOR CHANGE                                                      DATE ISSUED

    FS190730N036             Original release                                                        Sep. 09, 2019




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                       Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                       Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                        Page 3 of 8                                                    Report Version 1


                 Test Report No.: FS190730N036


   1. CERTIFICATION

                        FCC ID:     2ARH7-SG-001-19
                   PRODUCT:         WIRELESS CHARGER
              BRAND NAME:           SHADOWTRACK
                        MODEL:      ShadoWatch WLC00119
         ADDITIONAL NO.:            N/A

                 APPLICANT:         ShadowTrack Technologies, Inc.

                                    47 CFR PART 1, Subpart I, Section 1.1310
               STANDARDS:
                                    KDB 680106 D01




   .




                                    No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                    Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                    Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                     Page 4 of 8                                                    Report Version 1


                 Test Report No.: FS190730N036


   2. DESCRIPTION OF SUPPORT UNITS
   The EUT has been tested with associated equipment below

          Description               Manufacturer                     Model No.                      Serial No.

          ShadoWatch                 Shadowtrack                     SG-001-18                             /




   3. EQUIPMENTS USED DURING TEST

   Item       Test Equipment           Manufacturer            Model No.         Inventory No.          Car.Due date.
             3m Semi-Anechoic         ETS-LINDGRE
     1                                                        7m*4m*3m           NSEMC003                 Mar. 19, 20
                 Chamber                    N
              Exposure Level
     2                                      Narda               ELT-400               L-0012               Jun. 08,20
                  Tester
     3          B-field Probe               Narda                 Y2006               L-0017               Jun. 08,20
   NOTE:     1. The test was performed in RS chamber.
             2. The calibration interval of the above test instruments is 12 months and the calibrations are
                 traceable to CEPREI/CHINA, GRGT/CHINA and NIM/CHINA.




                                      No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                      Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                      Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                       Page 5 of 8                                                    Report Version 1


                  Test Report No.: FS190730N036


   4. TEST RESULTS

   4.1 RF EXPOSURE TEST
         Test Requirement:                               47 CFR PART 1, Subpart I, Section 1.1310
         Measurement Distance:                           0 mm
         Test voltage:                                   DC 3.7V from Battery

         Limit:
      Frequency              Electric field            Magnetic field           Power density                 Averaging time
      range(MHz)            strength (V/m)             strength (A/m)             (mW/cm2)                      (minutes)
                               (A) Limits for Occupational/Controlled Exposures
         0.3-3.0                   614                1.63               *(100)                                         6
         3.0-30                  1842/f              4.89/f            *(900/f2)                                        6
         30-300                   61.4               0.163                 1.0                                          6
        300-1500                      /                         /                     f/300                             6
     1500-100.000                     /                         /                           5                           6
                          (B) Limits for General Population/Uncontrolled Exposure
        0.3-1.34                    614                       1.63                    *(100)                           30
         1.34-30                    824/f                    2.19/f                 *(180/f2)                          30
         30-300                     27.5                     0.073                      0.2                            30
        300-1500                      /                         /                     f/1500                           30

     1500-100.000                     /                         /                       1.0                            30

   F=frequency in MHz
   *=Plane-wave equivalent power density
   RF exposure compliance will need to be determined with respect to 1.1307(c) and (d) of the FCC
   rules. The emissions should be within the limits at 300kHz in Table 1 of 1.1310(use the 300kHz limits
   for 150kHz:614V/m,1.63A/m).




   4.1.1 EUT OPERATION

   The antenna of this product, under normal use condition, is at less than 20cm away
   from the body of the user. So, this device is classified as Portable Device.


   EUT Operation:
   This device has been tested the worst status of full load and the device has been tested with
   shadowatch at zero charge, intermediate charge, and full charge.



                                            No. 34, Chenwulu Section, Guantai Rd., Houjie       Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                            Town, Dongguan City,                                Fax: +86 769 8593 1080
Dongguan Branch
                                            Guangdong 523942, China                             Email: customerservice.dg@cn.bureauveritas.com
                                                             Page 6 of 8                                                        Report Version 1


                 Test Report No.: FS190730N036


   4.1.2 MEASUREMENT DATA

     Output Voltage=DC 5V
     Wireless radiation frequency: 110KHz ~ 206KHz

     Electric Field Emissions
                                    Test Distance            Probe Measure
               Test Position                                                                 Limit (V/m)
                                        (mm)                  Result (V/m)
                  Side 1                  0                       3.47                            614
                  Side 2                  0                       4.48                            614
                  Side 3                  0                       4.34                            614
                  Side 4                  0                       3.58                            614
                   Top                    0                       4.81                            614
                  Bottom                  0                       4.22                            614

     Magnetic Field Emissions
                                    Test Distance            Probe Measure
               Test Position                                                                 Limit (A/m)
                                        (mm)                  Result (A/m)
                  Side 1                  0                      0.0093                           1.63
                  Side 2                  0                      0.0082                           1.63
                  Side 3                  0                      0.0091                           1.63
                  Side 4                  0                      0.0099                           1.63
                   Top                    0                      0.0147                           1.63
                  Bottom                  0                      0.0098                           1.63

          Note: All modes (while support units at 10%, 50 %, and 90% of charge ) have been tested and
                we only record the worst mode (10% of charge ) in the test result.




                                    No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                    Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                    Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                     Page 7 of 8                                                    Report Version 1


                  Test Report No.: FS190730N036


   5. PHOTOGRAPHS OF THE TEST CONFIGURATION
                                                 Electric Field




                                                Magnetic Field




    --- END ---
                                    No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                    Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                    Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                     Page 8 of 8                                                    Report Version 1



Document Created: 2019-09-27 11:21:52
Document Modified: 2019-09-27 11:21:52