   Applicant                        ShadowTrack Technologies, Inc.

                                    Cypress Bend Office Building, 1001 Ochsner Blvd Suite 425A, Covington, LA. 70433,
   Address
                                    USA

   Manufacturer or
                                    Shenzhen Xexun Technology Co.,Ltd
   Supplier
                                    F/7, Guangrong Building, MeiHua Rd., ShangMei lin, FuTian District, ShenZhen,
   Address
                                    China

   Product                          WIRELESS CHARGER

   Brand Name                       SHADOWTRACK

   Model                            ShadoWatch WLC00119

   Additional Model &
                                    N/A
   Model Difference

   Date of tests                    Jul. 30, 2019 ~ Aug. 15, 2019

   The submitted sample of the above equipment has been tested for according to the requirements of the
   following standards:

        FCC Part 15, Subpart C

   CONCLUSION: The submitted sample was found to COMPLY with the test requirement

                      Tested by Breeze Jiang                                                              Approved by Glyn He
                Project Engineer / EMC Department                                                      Supervisor/ EMC Department




                                                                                                              Date: Aug. 26, 2019
   This report is governed by, and incorporates by reference, CPS Conditions of Service as posted at the date of issuance of this report at
   http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/and is intended for your exclusive use. Any copying or
   replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report
   sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the
   quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our
   report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is
   only provided upon request for accredited tests. You have 60 days from date of issuance of this report to notify us of any material error or omission caused
   by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue
   you wish to raise. A failure to raise such issue within the prescribed time shall constitute you unqualified acceptance of the completeness of this report, the
   tests conducted and the correctness of the report contents.



                                                    No. 34, Chenwulu Section, Guantai Rd., Houjie                Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                                    Town, Dongguan City,                                         Fax: +86 769 8593 1080
Dongguan Branch
                                                    Guangdong 523942, China                                      Email: customerservice.dg@cn.bureauveritas.com
                                                                         Page 1 of 22                                                                Report Version 1


                        Test Report No.: RF190730N036


                                               TABLE OF CONTENTS
    RELEASE CONTROL RECORD ............................................................................................................ 3

    1      SUMMARY OF TEST RESULTS ..................................................................................................... 4

    2      MEASUREMENT UNCERTAINTY .................................................................................................. 4

    3      GENERAL INFORMATION .............................................................................................................. 5
        3.1      GENERAL DESCRIPTION OF EUT ......................................................................................... 5
        3.2      DESCRIPTION OF TEST MODES ........................................................................................... 6
        3.3      GENERAL DESCRIPTION OF APPLIED STANDARDS .......................................................... 6
        3.4      DESCRIPTION OF SUPPORT UNITS ..................................................................................... 6
    4      EMISSION TEST.............................................................................................................................. 7
        4.1    RADIATED EMISSION MEASUREMENT ................................................................................ 7
          4.1.1   LIMITS OF RADIATED EMISSION MEASUREMENT ...................................................... 7
          4.1.2   TEST INSTRUMENTS ....................................................................................................... 8
          4.1.3   TEST PROCEDURE .......................................................................................................... 9
          4.1.4   DEVIATION FROM TEST STANDARD ............................................................................. 9
          4.1.5   TEST SETUP ................................................................................................................... 10
          4.1.6   EUT OPERATING CONDITIONS .................................................................................... 10
          4.1.7   TEST RESULTS ...............................................................................................................11
        4.2    20DB BANDWIDTH MEASUREMENT ................................................................................... 17
          4.2.1   LIMITS OF 20DB BANDWIDTH MEASUREMENT ......................................................... 17
          4.2.2   TEST INSTRUMENTS ..................................................................................................... 17
          4.2.3   TEST PROCEDURE ........................................................................................................ 17
          4.2.4   DEVIATION FROM TEST STANDARD ........................................................................... 18
          4.2.5   TEST SETUP ................................................................................................................... 18
          4.2.6   EUT OPERATING CONDITION ...................................................................................... 18
          4.2.7   TEST RESULTS .............................................................................................................. 19
    5      PHOTOGRAPHS OF THE TEST CONFIGURATION ................................................................... 21

    6      APPENDIX A – MODIFICATIONS RECORDERS FOR ENGINEERING CHANGES TO THE EUT
            BY THE LAB ................................................................................................................................ 22




                                                  No. 34, Chenwulu Section, Guantai Rd., Houjie               Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                                  Town, Dongguan City,                                        Fax: +86 769 8593 1080
Dongguan Branch
                                                  Guangdong 523942, China                                     Email: customerservice.dg@cn.bureauveritas.com
                                                                       Page 2 of 22                                                             Report Version 1


                    Test Report No.: RF190730N036


                                    RELEASE CONTROL RECORD

     ISSUE NO.                  REASON FOR CHANGE                                                         DATE ISSUED

     RF190730N036               Original release                                                          Aug. 26, 2019




                                      No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                      Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                      Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                      Page 3 of 22                                                    Report Version 1


                    Test Report No.: RF190730N036


    1 SUMMARY OF TEST RESULTS

    The EUT has been tested according to the following specifications:


                               APPLIED STANDARD: FCC Part 15, Subpart C
      STANDARD
                              TEST TYPE AND LIMIT                    RESULT                     REMARK
       SECTION
         §15.203                Antenna Requirement                    PASS       No antenna connector is used.

         §15.207          AC Power Conducted Emission                   N/A                Power by Battery

         §15.209                    Radiated Emission                  PASS        Meet the requirement of limit.

       §15.215 (c)                   20dB Bandwidth                    PASS        Meet the requirement of limit.




    2 MEASUREMENT UNCERTAINTY
    Where relevant, the following measurement uncertainty levels have been estimated for
    tests performed on the EUT as specified in CISPR 16-4-2:

                    MEASUREMENT                               FREQUENCY                           UNCERTAINTY
                                                             9KHz ~ 30MHz                                2.16dB
                   Radiated emissions
                                                            30MHz ~ 1GMHz                                3.76dB


    This uncertainty represents an expanded uncertainty expressed at approximately the 95%
    confidence level using a coverage factor of k=2.




                                        No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                        Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                        Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                        Page 4 of 22                                                    Report Version 1


                    Test Report No.: RF190730N036

  3       GENERAL INFORMATION
      3.1 GENERAL DESCRIPTION OF EUT
      PRODUCT                            WIRELESS CHARGER
      MODEL NO.                          ShadoWatch WLC00119
      ADDITIONAL MODEL                   N/A
      FCC ID                             2ARH7-SG-001-19
                                         DC3.7V from Battery,
      POWER SUPPLY                       Battery Charging: DC 5V from USB Host Unit
      MODULATION TYPE                    ASK
      OPERATING FREQUENCY                110KHz ~ 206KHz
      ANTENNA TYPE                       Coil Antenna
      CABLE SUPPLIED                     USB cable: unshielded detachable 1.0m

      NOTES:
      1. For a more detailed features description, please refer to the manufacturer’s specifications or the user's
         manual.
      2. For the test results, the EUT had been tested with all conditions. But only the worst case was shown in
         test report.
      3. Please refer to the EUT photo document (Reference No.: 190730N036) for detailed product photo.
      4. When the EUT charging that RF function cann’t working, the charging mode was tested in the FCC VOC
         report.(report no.: FV190730N036)




                                     No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                     Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                     Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                     Page 5 of 22                                                    Report Version 1


                     Test Report No.: RF190730N036


  3.2       DESCRIPTION OF TEST MODES

    The EUT was tested under the following modes the final worst mode was marked in
    boldface and recorded in this report.

            TEST FREQUENCY                             TEST MODE                                TEST VOLTAGE
               174.5248KHz                              Transmitting
                                                                                          DC 3.7V from fully Battery
               123.6393KHz                                 Standby




    3.3 GENERAL DESCRIPTION OF APPLIED STANDARDS
    The EUT is a RF Product. According to the specifications of the manufacturer, it must comply with the
    requirements of the following standards:


    FCC Part 15, Subpart C
    ANSI C63.10-2013

    All test items have been performed and recorded as per the above standards.




  3.4        DESCRIPTION OF SUPPORT UNITS

    The EUT has been tested as a dependent unit together with other necessary accessories
    or support units. The following support units or accessories were used to form a
    representative test configuration during the tests.


     NO.           PRODUCT            BRAND            MODEL NO.                  SERIAL NO.                    FCC ID
        1      ShadoWatch           Shadowtrack         SG-001-18                       NA                         N/A


     NO. DESCRIPTION OF THE ABOVE SUPPORT UNITS
        1    N/A




                                        No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                        Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                        Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                        Page 6 of 22                                                     Report Version 1


                    Test Report No.: RF190730N036

    4    EMISSION TEST

    4.1 RADIATED EMISSION MEASUREMENT
  4.1.1 LIMITS OF RADIATED EMISSION MEASUREMENT

      TEST STANDARD: FCC Part 15, Subpart C, Section 15.209

    Emissions radiated outside of the specified bands, shall be according to the general
    radiated limits as following:

                   FREQUENCIES                 FIELD STRENGTH                   MEASUREMENT DISTANCE
                      (MHz)                    (microvolts/meter)                     (meters)
                   0.009 – 0.490                  2400/F(kHz)                                   300
                   0.490 – 1.705                 24000/F(kHz)                                    30
                    1.705 – 30.0                      30                                         30
                       30 – 88                       100                                         3
                      88 – 216                       150                                         3
                     216 - 960                       200                                         3
                     Above 960                       500                                         3
          NOTES:
         1. The lower limit shall apply at the transition frequencies.
         2. Emission level (dBuV/m) = 20 log Emission level (uV/m).
         3. As shown in 15.35(b), for frequencies above 1000MHz, the field strength limits are based on average
             detector, however, the peak field strength of any emission shall not exceed the maximum permitted
             average limits, specified above by more than 20dB under any condition of modulation.
         4. The measured field strength was extrapolated to distance 30 meters, using the formula that the limit of
            field strength varies as the inverse distance square (40dB per decade of distance)
             Example:
             13.56MHz = 15848uV/m                       30m
                          = 84dBuV/m                    30m
                          = 84+20log(30/3)2             3m
                          = 124dBuV/m




                                     No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                     Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                     Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                     Page 7 of 22                                                    Report Version 1


                    Test Report No.: RF190730N036

    4.1.2 TEST INSTRUMENTS
         FREQUENCY 9KHz-30MHz
          Equipment         Manufacturer                 Model No.          Serial No.      Last Cal.          Next Cal.
          EMI Test Receiver Rohde&Schwarz                ESR7               101564          Mar. 12,19         Mar. 11,20
          Active Loop
                            SCHWARZBECK                  FMZB 1519B         1519B-045 May 28,19                May 27,20
          Antenna
          Amplifier         Burgeon                      BPA-530      100210                Apr. 21,19         Apr. 20,20
                                                         ADT_Radiated
          Test Software             ADT                               N/A                   N/A                N/A
                                                         _V8.7.07
         NOTES: 1. The test was performed in 10m Chamber.
                2. The calibration interval of the above test instruments is 12 months. And the calibrations are
                 traceable to CEPREI/CHINA, GRGT/CHINA and NIM/CHINA.
                   3. The FCC Site Registration No. is 749762.


         FOR FREQUENCY RANGE BELOW 1GHz
         Equipment         Manufacturer  Model No.                          Serial No.            Last Cal.         Next Cal.
         EMI Test Receiver Rohde&Schwarz ESU26                              100005                Oct. 24,18        Oct. 23,19
         EMI Test Receiver Rohde&Schwarz ESR7                               101564                Mar. 12,19        Mar. 11,20
         Trilog-Broadband
                           SCHWARZBECK VULB 9168                            9168-555              Nov. 10, 18 Nov. 09, 19
         Antenna
         Trilog-Broadband
                           SCHWARZBECK VULB 9168                            9168-554              Dec. 10, 18 Dec. 09, 19
         Antenna
         Preamplifier      EMCI          EMC1135                            980378                Mar. 19,19        Mar. 18,20
         Preamplifier      EMCI          EMC1135                            980423                Mar. 19,19        Mar. 18,20
         10m Semi-anechoic               21.4m*12.1m*
                           CHANGLING                                        NSEMC006              Feb. 10,19        Feb. 09,20
         Chamber                         8.8m
                                         ADT_Radiated
         Test Software     ADT                                              N/A                   N/A               N/A
                                         _V8.7.07
        NOTES: 1. The test was performed in 10m Chamber.
               2. The calibration interval of the above test instruments is 12 months. And the calibrations are
                  traceable to CEPREI/CHINA, GRGT/CHINA and NIM/CHINA.
               3. The FCC Site Registration No. is 749762.




                                          No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                          Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                          Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 8 of 22                                                    Report Version 1


                    Test Report No.: RF190730N036

    4.1.3 TEST PROCEDURE

    < Below 30MHz >
      a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at
         a 10 meters Semi-anechoic chamber room. The table was rotated 360 degrees to
         determine the position of the highest radiation.
      b. The EUT was set 3 meters away from the interference-receiving antenna, which
         was mounted on the top of a variable-height antenna tower.
      c. The height of antenna is varied from one meter to four meters above the ground to
         determine the maximum value of the field strength. Both horizontal and vertical
         polarizations of the antenna are set to make the measurement.
      d. For each suspected emission, the EUT was arranged to its worst case and then
         the antenna was tuned to heights from 1 meter to 4 meters and the rotatable table
         was turned from 0 degrees to 360 degrees to find the maximum reading.
      e. The test-receiver system was set to quasi-peak detect function and specified
         bandwidth with maximum hold mode when the test frequency is below 1 GHz.
      f. For below 30MHz, a loop antenna with its vertical plane is place 3m from the EUT
         and rotated about its vertical axis for maximum response at each azimuth about the
         EUT. And the centre of the loop shall be 1m above the ground.
    <30MHz~1GHz >
      a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at
         a 10 meters semi-anechoic chamber. The table was rotated 360 degrees to
         determine the position of the highest radiation.
      b. The EUT was set 10 meters away from the interference-receiving antenna, which
         was mounted on the top of a variable-height antenna tower.
      c. The antenna is a broadband antenna, and its height is varied from one meter to
         four meters above the ground to determine the maximum value of the field
         strength. Both horizontal and vertical polarizations of the antenna are set to make
         the measurement.
      d. For each suspected emission, the EUT was arranged to its worst case and then
         the antenna was tuned to heights from 1 meter to 4 meters and the rotatable table
         was turned from 0 degrees to 360 degrees to find the maximum reading.
      e. The test-receiver system was set to Peak Detect Function and Specified
         Bandwidth with Maximum Hold Mode.

      NOTE:
      1. The resolution bandwidth of test receiver/spectrum analyzer is 120kHz for Quasi-peak detection (QP) at
         frequency below 1GHz.
      2. Emission level(dBuV/m)=Raw Value(dBuV) + Correction Factor(dB/m)
      3. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB)
      4. Margin value = Emission level – Limit value.

  4.1.4 DEVIATION FROM TEST STANDARD

    No deviation.
                                    No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                    Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                    Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                    Page 9 of 22                                                    Report Version 1


                    Test Report No.: RF190730N036


    4.1.5 TEST SETUP

    Below 30MHz test setup




    Below 1GHz test setup
                                                                       Ant. Tower
                                                                                                    1-4m
                                                       10m
                               EUT

                                                Turn Table

                        0.8m


                                                     Ground Plane

                                                    Spectrum




    Note: For the actual test configuration, please refer to the attached file (Test Setup Photo).




  4.1.6 EUT OPERATING CONDITIONS
         a. Turn on the power supply of the EUT.
         b. EUT was operated according to the type description in
            manufacturer’s specifications or the User's Manual.


                                     No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                     Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                     Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                    Page 10 of 22                                                    Report Version 1


                    Test Report No.: RF190730N036

    4.1.7 TEST RESULTS


                                                                   FREQUENCY
        TEST MODE                   Transmitting                                              9 -150KHz
                                                                   RANGE
                                                                   DETECTOR
                                                                   FUNCTION &
        TEST VOLTAGE                DC3.7V from Battery                                       Quasi-Peak, 200Hz
                                                                   RESOLUTION
                                                                   BANDWIDTH
        ENVIRONMENTAL
                                    25deg. C, 65% RH               TESTED BY: Vincent
        CONDITIONS

                        ANTENNA POLARITY & TEST DISTANCE: PARALLEL AT 3M
                       Correction  Raw   Emission                  Antenna                                    Table
       No     Freq.                                  Limit  Margin
                         Factor    Value   Level                    Height                                   Angle
        .    (MHz)                                (dBuV/m)   (dB)
                         (dB/m)   (dBuV) (dBuV/m)                    (cm)                                   (Degree)
        1   0.03520      -11.72    49.33   37.61    116.66  -79.05    100                                      239
        2   0.06540      -11.75    47.75   36.00    111.29  -75.29    100                                      130
        3   0.06750      -11.74    44.76   33.02    111.02  -78.00    100                                      139
        4   0.08720      -11.66    39.97   28.31    108.79  -80.48    100                                      228
        5   0.10900      -11.57    37.16   25.59    106.85  -81.26    100                                      124
        6   0.13090      -11.50    37.73   26.23    105.26  -79.03    100                                      115

    REMARKS: 1. Peak detector quick scan is showed on the graph and final quasi-peak detector data is
                  measured corresponding to relevant limit and recorded in the data table.
               2. Negative sign (-) in the margin column signify levels below the limit.
               3. Frequency range scanned: 0.009-0.15MHz.
               4. Only emissions significantly above equipment noise floor are reported.




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                       Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                       Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                      Page 11 of 22                                                    Report Version 1


                    Test Report No.: RF190730N036




                                                                 FREQUENCY
        TEST MODE                   Transmitting                                            150KHz-30MHz
                                                                 RANGE
                                                                 DETECTOR
                                                                 FUNCTION &
        TEST VOLTAGE                DC3.7V from Battery                                     Quasi-Peak, 200Hz
                                                                 RESOLUTION
                                                                 BANDWIDTH
        ENVIRONMENTAL
                                    25deg. C, 65% RH             TESTED BY: Vincent
        CONDITIONS

                        ANTENNA POLARITY & TEST DISTANCE: PARALLEL AT 3M
                       Correction  Raw   Emission                  Antenna                                    Table
       No     Freq.                                  Limit  Margin
                         Factor    Value   Level                    Height                                   Angle
        .    (MHz)                                (dBuV/m)   (dB)
                         (dB/m)   (dBuV) (dBuV/m)                    (cm)                                   (Degree)
        1 0.17390        -11.42    68.55   57.13    102.80  -45.67    100                                      166
        2 0.55300        -11.38    48.53   37.15     72.85  -35.70    100                                       94
        3 1.10520        -11.03    40.30   29.27     67.39  -38.12    100                                      286
        4 9.78900        -10.65    29.29   18.64    69.54   -50.90    100                                      206
        5 16.90270       -10.54    28.66   18.12    69.54   -51.42    100                                      339
        6 21.16100       -10.07    28.60   18.53    69.54   -51.01    100                                      360

    REMARKS: 1. Peak detector quick scan is showed on the graph and final quasi-peak detector data is
                  measured corresponding to relevant limit and recorded in the data table.
               2. Negative sign (-) in the margin column signify levels below the limit.
               3. Frequency range scanned: 0.15-30MHz.
               4. Only emissions significantly above equipment noise floor are reported.




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                       Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                       Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                      Page 12 of 22                                                    Report Version 1


                    Test Report No.: RF190730N036




                                                                 FREQUENCY
        TEST MODE                   Transmitting                                            9 -150KHz
                                                                 RANGE
                                                                 DETECTOR
                                                                 FUNCTION &
        TEST VOLTAGE                DC3.7V from Battery                                     Quasi-Peak, 200Hz
                                                                 RESOLUTION
                                                                 BANDWIDTH
        ENVIRONMENTAL
                                    25deg. C, 65% RH             TESTED BY: Vincent
        CONDITIONS

                    ANTENNA POLARITY & TEST DISTANCE: PERPENDICYLARL AT 3M
                     Correction  Raw    Emission                  Antenna                                        Table
       No     Freq.                                 Limit  Margin
                      Factor     Value    Level                    Height                                        Angle
        .    (MHz)                               (dBuV/m)   (dB)
                      (dB/m)    (dBuV)  (dBuV/m)                    (cm)                                       (Degree)
        1   0.01540   -11.30     53.95    42.65    123.87  -81.22    100                                          318
        2   0.03520   -11.72     49.70    37.98    116.68  -78.70    100                                          316
        3   0.06430   -11.76     43.47    31.71    111.44  -79.73    100                                          117
        4   0.08590   -11.67     39.77    28.10    108.92  -80.82    100                                          176
        5   0.10260   -11.59     38.12    26.53    107.38  -80.85    100                                          202
        6   0.12860   -11.51     37.34    25.83    105.42  -79.59    100                                          360

    REMARKS: 1. Peak detector quick scan is showed on the graph and final quasi-peak detector data is
                  measured corresponding to relevant limit and recorded in the data table.
               2. Negative sign (-) in the margin column signify levels below the limit.
               3. Frequency range scanned: 0.009-0.15MHz.
               4. Only emissions significantly above equipment noise floor are reported.




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                       Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                       Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                      Page 13 of 22                                                    Report Version 1


                    Test Report No.: RF190730N036




                                                                 FREQUENCY
        TEST MODE                   Transmitting                                            150KHz-30MHz
                                                                 RANGE
                                                                 DETECTOR
                                                                 FUNCTION &
        TEST VOLTAGE                DC3.7V from Battery                                     Quasi-Peak, 200Hz
                                                                 RESOLUTION
                                                                 BANDWIDTH
        ENVIRONMENTAL
                                    25deg. C, 65% RH             TESTED BY: Vincent
        CONDITIONS

                 ANTENNA POLARITY & TEST DISTANCE: PERPENDICYLARL AT 3M
                   Correction  Raw    Emission                 Antenna                                           Table
       No  Freq.                                 Limit  Margin
                     Factor    Value    Level                   Height                                           Angle
        . (MHz)                                (dBuV/m)  (dB)
                     (dB/m)   (dBuV)  (dBuV/m)                   (cm)                                          (Degree)
       1 0.19330     -11.40    78.00    66.60   101.88  -35.28    100                                             229
       2 0.58430     -11.31    52.52    41.21    72.41  -31.20    100                                             282
       3 1.09930     -11.03    45.47    34.44    67.43  -32.99    100                                              13
       4 3.23370     -10.85    30.05    19.20    69.54  -50.34    100                                               6
       5 10.22190    -10.64    29.61    18.97    69.54  -50.57    100                                             252
       6 17.16090    -10.51    28.75    18.24    69.54  -51.30    100                                             294

    REMARKS: 1. Peak detector quick scan is showed on the graph and final quasi-peak detector data is
                  measured corresponding to relevant limit and recorded in the data table.
               2. Negative sign (-) in the margin column signify levels below the limit.
               3. Frequency range scanned: 0.15-30MHz
               4. Only emissions significantly above equipment noise floor are reported.




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                       Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                       Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                      Page 14 of 22                                                    Report Version 1


                    Test Report No.: RF190730N036



                                                                    FREQUENCY
        TEST MODE                   Transmitting                                                30-1000MHz
                                                                    RANGE
                                                                    DETECTOR
                                                                    FUNCTION &
        TEST VOLTAGE                DC3.7V from Battery                                         Quasi-Peak, 120kHz
                                                                    RESOLUTION
                                                                    BANDWIDTH
        ENVIRONMENTAL
                                    25deg. C, 65% RH                TESTED BY: Vincent
        CONDITIONS

                     ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 10M
                        Correction  Raw   Emission                 Antenna   Table
                 Freq.                               Limit  Margin
        No.              Factor     Value   Level                   Height  Angle
                (MHz)                              (dBuV/m) (dB)
                         (dB/m)    (dBuV) (dBuV/m)                   (cm)  (Degree)
         1      42.125        -17.27       32.22          14.95         30.00          -15.05         200            241
         2     160.708        -16.67       29.83          13.16         30.00          -16.84         200            194
         3     236.610        -17.35       30.20          12.85         37.00          -24.15         400            329
         4     284.383        -15.47       30.12          14.65         37.00          -22.35         400             43
         5     360.406        -13.63       30.76          17.13         37.00          -19.87         200             70
         6     401.631        -12.09       29.88          17.79         37.00          -19.21         200            138

    REMARKS:         1. Peak detector quick scan is showed on the graph and final quasi-peak detector data is
                        measured corresponding to relevant limit and recorded in the data table.
                     2. Negative sign (-) in the margin column signify levels below the limit.
                     3. Frequency range scanned: 30MHz to 1000MHz.
                     4. Only emissions significantly above equipment noise floor are reported.




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie    Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                       Town, Dongguan City,                             Fax: +86 769 8593 1080
Dongguan Branch
                                       Guangdong 523942, China                          Email: customerservice.dg@cn.bureauveritas.com
                                                      Page 15 of 22                                                     Report Version 1


                    Test Report No.: RF190730N036


                                                                    FREQUENCY
        TEST MODE                   Transmitting                                               30-1000MHz
                                                                    RANGE
                                                                    DETECTOR
                                                                    FUNCTION &
        TEST VOLTAGE                DC3.7V from Battery                                        Quasi-Peak, 120kHz
                                                                    RESOLUTION
                                                                    BANDWIDTH
        ENVIRONMENTAL
                                    25deg. C, 65% RH                TESTED BY: Vincent
        CONDITIONS

                        ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 10M
                          Correction Raw    Emission                 Antenna                                      Table
                  Freq.                                Limit  Margin
        No.                Factor     Value   Level                   Height                                     Angle
                 (MHz)                               (dBuV/m) (dB)
                           (dB/m)    (dBuV) (dBuV/m)                   (cm)                                     (Degree)
         1      42.708        -17.24      31.80         14.56         30.00        -15.44          300              165
         2      170.221       -15.96      31.54         15.58         30.00        -14.42          300               88
         3      252.335       -15.30      36.23         20.93         37.00        -16.07          100              206
         4      338.815       -12.30      29.43         17.13         37.00        -19.87          300               20
         5      414.818       -10.96      29.49         18.53         37.00        -18.47          100               88
         6      491.937        -8.54      29.67         21.13         37.00        -15.87          100              347

    REMARKS:         1. Peak detector quick scan is showed on the graph and final quasi-peak detector data is
                        measured corresponding to relevant limit and recorded in the data table.
                     2. Negative sign (-) in the margin column signify levels below the limit.
                     3. Frequency range scanned: 30MHz to 1000MHz.
                     4. Only emissions significantly above equipment noise floor are reported.




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                       Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                       Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                      Page 16 of 22                                                    Report Version 1


                    Test Report No.: RF190730N036

  4.2      20DB BANDWIDTH MEASUREMENT


  4.2.1 LIMITS OF 20DB BANDWIDTH MEASUREMENT
    The field strength of any emissions appearing between the band edges and out of band
    shall be attenuated at least 20 dB below the level of the unmodulated carrier or to the
    general limits in Section 15.209.


  4.2.2 TEST INSTRUMENTS
    Equipment                 Manufacturer          Model No.        Serial No.         Last Cal.        Next Cal.
    Power Sensor              Keysight              U2021XA          MY55060016         May 22,19        May 21,20
    Power Sensor              Keysight              U2021XA          MY55060018         May 22,19        May 21,20
    Power Meter               Anritsu               ML2495A          1139001            Mar. 12,19       Mar. 11,20
    Power Sensor              Anritsu               MA2411B          1531155            Mar. 12,19       Mar. 11,20
    Digital Multimeter        FLUKE                 15B              A1220010DG         Oct. 17, 18      Oct.16, 19
    Humid & Temp
                              Haida                 HD-2257          110807201          Nov.15,18        Nov. 14,19
    Programmable Tester
    Oscilloscope              Agilent               DSO9254A         MY51260160         Nov. 09,18       Nov. 08,19
    Signal Analyzer           Rohde & Schwarz FSV7                   102331             May 22,19        May 21,20
    Signal Generator          Agilent               N5183A           MY50140980         Dec. 07,18 Dec. 06,19
    Agile Signal
                              Agilent               8645A            Agilent            Oct.27, 18       Oct.26, 19
    Generator
    Spectrum Analyzer         Keysight              N9020A           MY55400499         Mar. 12,19       Mar. 11,20
    MXG-B RF Vector
                              Keysight              N5182B           MY56200288         Dec. 07, 18 Dec. 06, 19
    Signal Generator
    BLUETOOTH
                              Rohde&Schwarz CBT32                    100811             May 20,19        May 19,20
    TESTER
    Attenuator                MINI                  BW-S10W2+ S130129FGE2 N/A                            N/A
    DC Source              Keysight            E3642A        MY56146098 N/A               N/A
    NOTES:
       1. The test was performed in RF Oven room.
      2. The calibration interval of the above test instruments is 12 months and the calibrations are traceable to
         CEPREI/CHINA, GRGT/CHINA and NIM/CHINA.



  4.2.3 TEST PROCEDURE
      a. Check the calibration of the measuring instrument using either an internal calibrator or a known signal
          from an external generator.

      b. Turn on the EUT and connect it to measurement instrument. Then set it to any one convenient
          frequency within its operating range. Set a reference level on the measuring instrument equal to the
          highest peak value.

      c. Measure the frequency difference of two frequencies that were attenuated 20dB from the reference level.

                                        No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                        Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                        Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                       Page 17 of 22                                                    Report Version 1


                    Test Report No.: RF190730N036

          Record the frequency difference as the emission bandwidth.

      d. Repeat above procedures until all frequencies measured were complete.




  4.2.4 DEVIATION FROM TEST STANDARD

    No deviation.




  4.2.5 TEST SETUP

                     EUT                                                SPECTRUM
                                                                        ANALYZER
                                             10dB ATTENUATION
                                             PAD




  4.2.6 EUT OPERATING CONDITION


    a. Turn on the EUT.
    b. The EUT tested in charging mode and standby mode respectively.




                                    No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                    Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                    Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                   Page 18 of 22                                                    Report Version 1


                    Test Report No.: RF190730N036

  4.2.7 TEST RESULTS


                    TEST MODE                 CHANNEL FREQUENCY (KHz)                    20dB BANDWIDTH (KHz)

                     Transmitting                           174.5248                                  1.5109


                Lower & Upper Test Frequency Point                  Test Frequency
                                                                                                        P/F
                              (MHz)                                      (KHz)
                                    Lower                                173.6565                      PASS
                                    Upper                                175.1673                      PASS

    Test Data:




                                     No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                     Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                     Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                    Page 19 of 22                                                    Report Version 1


                    Test Report No.: RF190730N036




                    TEST MODE                 CHANNEL FREQUENCY (KHz)                     20dB BANDWIDTH (Hz)

                        Standby                             123.6393                                   868.3


                Lower & Upper Test Frequency Point                  Test Frequency
                                                                                                        P/F
                              (MHz)                                      (KHz)
                                    Lower                                123.2312                      PASS
                                    Upper                                124.0995                      PASS

    Test Data:




                                     No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                     Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                     Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                    Page 20 of 22                                                    Report Version 1


                    Test Report No.: RF190730N036


    5      PHOTOGRAPHS OF THE TEST CONFIGURATION


     Please refer to the attached file (Test Setup Photo).




                                    No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                    Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                    Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                   Page 21 of 22                                                    Report Version 1


                    Test Report No.: RF190730N036


   6 APPENDIX A – MODIFICATIONS RECORDERS FOR ENGINEERING
       CHANGES TO THE EUT BY THE LAB

    No any modifications were made to the EUT by the lab during the test.




    ---END---




                                    No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                    Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                    Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                   Page 22 of 22                                                    Report Version 1



Document Created: 2019-10-08 04:08:04
Document Modified: 2019-10-08 04:08:04

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC