                                         TEST REPORT
                                        No. I17D00219-SRD05

                                                              For
                                 Client : Shanghai Simcom Ltd.

                           Production : LTE-FDD/HSPA MODULE

                        Model Name : SIM7600A

                                  FCC ID: UDV-201709

               Hardware Version: V1.02

                 Software Version: B02V01

                          Issued date: 2017-07-09



Note:
The test results in this test report relate only to the devices specified in this report. This report shall not
be reproduced except in full without the written approval of ECIT Shanghai.
Test Laboratory:
ECIT Shanghai, East China Institute of Telecommunications
Add: 7-8F, G Area, No.668, Beijing East Road, Huangpu District, Shanghai, P. R. China
Tel: (+86)-021-63843300, E-Mail: welcome@ecit.org.cn


                             RF Test Report                       Report No.: I17D00219-SRD05


                                         Revision Version
        Report Number               Revision       Date                      Memo
       I17D00219-SRD05                 00       2017-07-09        Initial creation of test report




East China Institute of Telecommunications                   Page Number          : 2 of 17
TEL: +86 21 63843300 FAX: +86 21 63843301                    Report Issued Date   : Jul.09.2017


                                          RF Test Report                                         Report No.: I17D00219-SRD05



                                                            CONTENTS

1.      TEST LABORATORY ............................................................................................................... 4

1.1. TESTING LOCATION ............................................................................................................... 4

1.2. TESTING ENVIRONMENT ....................................................................................................... 4

1.3. PROJECT DATA ....................................................................................................................... 4

1.4. SIGNATURE ............................................................................................................................. 4

2.      CLIENT INFORMATION ........................................................................................................... 5

2.1. APPLICANT INFORMATION ................................................................................................... 5

2.2. MANUFACTURER INFORMATION ......................................................................................... 5

3.      EQUIPMENT UNDER TEST (EUT) AND ANCILLARY EQUIPMENT (AE) ............................ 6

3.1. ABOUT EUT ............................................................................................................................. 6

3.2. INTERNAL IDENTIFICATION OF EUT USED DURING THE TEST ....................................... 6

3.3. INTERNAL IDENTIFICATION OF AE USED DURING THE TEST ......................................... 6

3.4. STATEMENTS........................................................................................................................... 6

4.      REFERENCE DOCUMENTS .................................................................................................... 7

4.1. REFERENCE DOCUMENTS FOR TESTING .......................................................................... 7

5.      SUMMARY OF TEST RESULTS .............................................................................................. 8

6.      TEST EQUIPMENT UTILIZED ................................................................................................. 9

7.      TEST ENVIRONMENT ........................................................................................................... 11

ANNEX A.             MEASUREMENT RESULTS .................................................................................... 12

ANNEX B.             DEVIATIONS FROM PRESCRIBED TEST METHODS .......................................... 17




  East China Institute of Telecommunications                                              Page Number                : 3 of 17
  TEL: +86 21 63843300 FAX: +86 21 63843301                                               Report Issued Date         : Jul.09.2017


                             RF Test Report                         Report No.: I17D00219-SRD05



1. Test Laboratory

1.1. Testing Location

 Company Name:              ECIT Shanghai, East China Institute of Telecommunications
 Address:                   7-8F, G Area, No. 668, Beijing East Road, Huangpu District,
                            Shanghai, P. R. China
 Postal Code:               200001
 Telephone:                 (+86)-021-63843300
 Fax:                       (+86)-021-63843301
 FCC Registration NO.:      489729


1.2. Testing Environment

 Normal Temperature:         15-35℃
 Extreme Temperature:        -10/+55℃
 Relative Humidity:          20-75%


1.3. Project data

 Project Leader:             Zhou Yan
 Testing Start Date:         2016-06-03
 Testing End Date:           2016-08-05
 Testing Start Date:         2017-06-21 (N06 for RSE)
 Testing End Date:           2017-06-28 (N06 for RSE)


1.4. Signature




            Yang Dejun                                                   Ding Li
        (Prepared this test report)                              (Reviewed this test report)




                                        Zheng Zhongbin
                                    Director of the laboratory
                                   (Approved this test report)


East China Institute of Telecommunications                  Page Number          : 4 of 17
TEL: +86 21 63843300 FAX: +86 21 63843301                   Report Issued Date   : Jul.09.2017


                             RF Test Report                     Report No.: I17D00219-SRD05



2. Client Information

2.1. Applicant Information
  Company Name:             Shanghai Simcom Ltd.
                            SIM Technology Building.,No.633, Jinzhong Rd,Changning District,
  Address:
                            Shanghai, P.R.China
  Contact:                  yongsheng.li
  Telephone:                021-32523134


2.2. Manufacturer Information
  Company Name:             Shanghai Simcom Ltd.
                            SIM Technology Building.,No.633, Jinzhong Rd,Changning District,
  Address:
                            Shanghai, P.R.China
  Contact:                  yongsheng.li
  Telephone:                021-32523134




East China Institute of Telecommunications                 Page Number          : 5 of 17
TEL: +86 21 63843300 FAX: +86 21 63843301                  Report Issued Date   : Jul.09.2017


                              RF Test Report                              Report No.: I17D00219-SRD05



3. Equipment Under Test (EUT) and Ancillary Equipment (AE)
3.1. About EUT

EUT Description                      LTE-FDD/HSPA MODULE
Model name                           SIM7600A
FCC ID                               UDV-201709
Frequency                            WCDMA Band II/V
                                     LTE FDD2/4/12
Extreme Temperature                  -10/+55℃
Nominal Voltage                      3.8V
Extreme High Voltage                 4.2V
Extreme Low Voltage                  3.4V
 Note: Photographs of EUT are shown in ANNEX A of this test report.

3.2. Internal Identification of EUT used during the test

EUT ID*     SN or IMEI               HW Version             SW Version                     Date of receipt
      N06    861475030055224         V1.02                  B02V01                         2017-06-11
*EUT ID: is used to identify the test sample in the lab internally.


3.3. Internal Identification of AE used during the test

AE ID*          Description                                                    SN
AE1             RF cable                                                       ---
---             ---                                                            ---


*AE ID: is used to identify the test sample in the lab internally.

3.4. Statements
The product name SIM7600A, supporting WCDMA/DC-HSDPA/LTE, manufactured by Shanghai
Simcom Ltd. is a variant product for testing. According to the variant description, All the test results
please refer to I16D00113-RFA_V2 except the worse case of Band 2 and Band 5’RSE.

ECIT has verified that the compliance of the tested device specified in section 5 of this test report
is successfully evaluated according to the procedure and test methods as defined in type
certification requirement listed in section 5 of this test report.




East China Institute of Telecommunications                           Page Number          : 6 of 17
TEL: +86 21 63843300 FAX: +86 21 63843301                            Report Issued Date   : Jul.09.2017


                             RF Test Report                          Report No.: I17D00219-SRD05



4. Reference Documents

4.1. Reference Documents for testing
The following documents listed in this section are referred for testing.


 Reference                Title                                                             Version
 FCC Part 24              PERSONAL COMMUNICATIONS SERVICES                                  2014
 FCC Part 22              PUBLIC MOBILE SERVICES                                            2014
 ANSI-TIA-603-E           Land Mobile FM or PM Communications Equipment                     2016
                          Measurement and Performance Standards
 ANSI C63.4               Methods of Measurement of Radio-Noise Emissions from              2014
                          Low-Voltage Electrical and Electronic Equipment in the
                          Range of 9 kHz to 40 GHz




East China Institute of Telecommunications                      Page Number          : 7 of 17
TEL: +86 21 63843300 FAX: +86 21 63843301                       Report Issued Date   : Jul.09.2017


                             RF Test Report                              Report No.: I17D00219-SRD05



5. SUMMARY OF TEST RESULTS
  Item            Test items                         FCC rules                          result


   1             Output Power                2.1046/22.913(a)/24.232(c)                   N/A




   2        Peak-to-Average Ratio                    24.232(d)                            N/A



                99%Occupied
   3                                           2.1049(h)(i)/ 22.917(b)                    N/A
                  Bandwidth


                -26dB Emission
   4                                           22.917(b)/§24.238(b)                       N/A
                  Bandwidth


            Band Edge at antenna
   5                                            22.917(a)/24.238(a)                       N/A
                 terminals



   6          Frequency stability                  2.1055/24.235                          N/A



             Conducted Spurious
   7                                         2.1053/22.917(a)/24.238(a)                   N/A
                  mission


                                       2.1051/22.917/24.238/22.913/24
   8            Emission Limit                                                           Pass
                                                        .232




East China Institute of Telecommunications                         Page Number          : 8 of 17
TEL: +86 21 63843300 FAX: +86 21 63843301                          Report Issued Date   : Jul.09.2017


                             RF Test Report                          Report No.: I17D00219-SRD05



6. Test Equipment Utilized

Climate chamber
                                         Serial    Manufactur         Calibration       Cal.interval
  No.     Equipment        Model
                                        Number        er                 date
            Climate                                                                        2 Year
   1                       SH-641      92012011       ESPEC           2016-01-06
            chamber

Radiated emission test system
The test equipment and ancillaries used are as follows.


                                     Serial        Manufactur        Calibration
 No.     Equipment        Model                                                         Cal.interval
                                     Number        er                date


           Universal
            Radio         CMU20
   1                                    123123            R&S          2017-05-11           1 Year
         Communicatio       0
           n Tester

           EMI Test
   2                       ESU40        100307            R&S          2017-05-11           1 Year
           Receiver

           TRILOG
                           VULB9      VULB9163-    Schwarzbec
   3      Broadband                                                    2017-02-25           3 Year
                            163          515           k
           Antenna
           Double-
            ridged         ETS-31
   4                                   00135890           ETS          2017-01-11           3 Year
          Waveguide          17
           Antenna

             2-Line        ENV21
   5                                    101380            R&S          2017-05-11           1 Year
           V-Network         6

         Substitution A    ETS-31
   6                                   00135890           ETS          2017-01-11           3 Year
            ntenna           17

           RF Signal       SMF10
   7                                    102314            R&S          2017-05-11           1 Year
           Generator        0A

         Substitution A    VUBA9                   Schwarzbec
   8                                   9117-266                        2017-08-18           3 Year
            ntenna          117                        k


   9        Amplifier      SCU03         10009            R&S          2017-01-05           1 Year



East China Institute of Telecommunications                      Page Number          : 9 of 17
TEL: +86 21 63843300 FAX: +86 21 63843301                       Report Issued Date   : Jul.09.2017


                             RF Test Report                        Report No.: I17D00219-SRD05


                          NTWPA
  10        Amplifier     -008610      12023024     Rflight          2017-01-05           1 Year
                             F

                           BW-N3
  11      Attenuators                        /      MCL              2017-01-05           1 Year
                            W5+




Conducted test system

                                                                       Calibratio
  No.       Name           Type              SN    Manufacture                         Cal.interval
                                                                        n date

          Spectrum
   1                      FSQ26          101096        R&S            2017-05-11          1 Year
          Analyzer

           Universal
   2        Radio        CMU200          123102        R&S            2017-05-11          1 Year
         Communicat
          ion Tester
          DC Power       ZUP60-1     LOC-220Z006                                          1 Year
   3                                               TDL-Lambda         2017-05-11
            Supply          4           -0007




East China Institute of Telecommunications                    Page Number          : 10 of 17
TEL: +86 21 63843300 FAX: +86 21 63843301                     Report Issued Date   : Jul.09.2017


                                RF Test Report                   Report No.: I17D00219-SRD05



7. Test Environment

Shielding Room1 (6.0 meters×3.0 meters×2.7 meters) did not exceed following limits along the
conducted RF performance testing:
             Temperature                                  Min. = 15 ℃, Max. = 35 ℃

           Relative humidity                              Min. = 20 %, Max. = 75 %

        Shielding effectiveness                                   > 100 dB

      Ground system resistance                                        < 0.5 

Control room did not exceed following limits along the EMC testing:
            Temperature                                   Min. = 15 ℃, Max. = 35 ℃

           Relative humidity                              Min. =25 %, Max. = 75 %

      Shielding effectiveness                                    > 100 dB

        Electrical insulation                                     > 10 k

      Ground system resistance                                    < 0.5 
Fully-anechoic chamber1 (6.9 meters×10.9 meters×5.4 meters) did not exceed following limits
along the EMC testing:

                Temperature                             Min. = 15 ℃, Max. = 35 ℃

             Relative humidity                           Min. = 25 %, Max. = 75 %

          Shielding effectiveness                                > 100 dB

            Electrical insulation                                 > 10 k

        Ground system resistance                                  < 0.5 

                   VSWR                          Between 0 and 6 dB, from 1GHz to 18GHz

         Site Attenuation Deviation                Between -4 and 4 dB,30MHz to 1GHz

        Uniformity of field strength          Between 0 and 6 dB, from 80MHz to 3000 MHz




East China Institute of Telecommunications                  Page Number          : 11 of 17
TEL: +86 21 63843300 FAX: +86 21 63843301                   Report Issued Date   : Jul.09.2017


                             RF Test Report                        Report No.: I17D00219-SRD05



ANNEX A.          MEASUREMENT RESULTS

A.1 RSE
A.1.1 EMISSION LIMIT (§2.1051/§22.917§24.238)

A.1.1.1 The procedure of radiated spurious emissions is as follows:
1. EUT was placed on a 1.5 meter high non-conductive stand at a 3 meter test distance from the
receive antenna. A receiving antenna was placed on the antenna mast 3 meters from the EUT for
emission measurements. The height of receiving antenna is 1.5m. The test setup refers to figure
below. Detected emissions were maximized at each frequency by rotating the EUT through 360°
and adjusting the receiving antenna polarization. The radiated emission measurements of all
non-harmonic and harmonics of the transmit frequency through the 10thharmonic were measured
with peak detector.




2. The EUT is then put into continuously transmitting mode at its maximum power level during
the test. And the maximum value of the receiver should be recorded as (Pr).
3. The EUT shall be replaced by a substitution antenna. The test setup refers to figure below.




In the chamber, an substitution antenna for the frequency band of interest is placed at the
reference point of the chamber. An RF Signal source for the frequency band of interest is
connected to the substitution antenna with a cable that has been constructed to not interfere
with the radiation pattern of the antenna. A power (PMea) is applied to the input of the
substitution antenna, and adjust the level of the signal generator output until the value of the
receiver reach the previously recorded (Pr). The power of signal source (PMea) is recorded. The
test should be performed by rotating the test item and adjusting the receiving antenna
polarization.
East China Institute of Telecommunications                    Page Number          : 12 of 17
TEL: +86 21 63843300 FAX: +86 21 63843301                     Report Issued Date   : Jul.09.2017


                             RF Test Report                         Report No.: I17D00219-SRD05


4. The Path loss (Ppl) between the Signal Source with the Substitution Antenna and the
Substitution Antenna Gain (Ga) should be recorded after test.
A amplifier should be connected in for the test.
The Path loss (Ppl) is the summation of the cable loss .
The measurement results are obtained as described below:
Power(EIRP)=PMea- Ppl+ Ga
5. This value is EIRP since the measurement is calibrated using an antenna of known gain (2.15
dBi) and known input power.
6. ERP can be calculated from EIRP by subtracting the gain of the dipole, ERP = EIRP -2.15dBi



A.1.1.2. WCDMA Measurement Method
The measurements procedures in TIA-603E-2016 are used.
The spectrum was scanned from 30 MHz to the 10th harmonic of the highest frequency generated
within the equipment. The resolution bandwidth is set as outlined in Part 24.238 and Part 24.917.
The spectrum is scanned with the mobile station transmitting at carrier frequencies that pertain to
low, mid and high channels of WCDMA Band II and WCDMA Band V.

A.1.1.2.1. Measurement Limit
Part 24.238 and Part 22.917 specify that the power of any emission outside of the authorized
operating frequency ranges must be attenuated below the transmitting power (P) by a factor of at
least 43 + 10 log(P) dB.
The specification that emissions shall be attenuated below the transmitter power (P) by at least 43
+ 10 log (P) dB, translates in the relevant power range (1 to 0.001 W) to -13 dBm. At 1 W the
specified minimum attenuation becomes 43 dB and relative to a 30 dBm (1 W) carrier becomes a
limit of -13 dBm. At 0.001 W (0 dBm) the minimum attenuation is 13 dB, which again yields a limit
of -13 dBm. In this way a translation of the specification from relative to absolute terms is carried
out.
A.1.1.2.2. Measurement Results
Radiated emissions measurements were made only at the upper, middle, and lower carrier
frequencies of the WCDMA Band II and WCDMA Band V (826.4MHz, 836.6MHz and 846.6MHz) .
It was decided that measurements at these three carrier frequencies would be sufficient to
demonstrate compliance with emissions limits because it was seen that all the significant spurs
occur well outside the band and no radiation was seen from a carrier in one block of the WCDMA
Band II and WCDMA Band V into any of the other blocks. The equipment must still, however, meet
emissions requirements with the carrier at all frequencies over which it is capable of operating and
it is the manufacturer's responsibility to verify this.
Note: We only test the worse case
A.1.1.2.3. Measurement Results Table
      Frequency                 Channel            Frequency Range                   Result

                                  Low                30MHz~20GHz                        P
   WCDMA Band II
                                 Middle              30MHz~20GHz                        P
East China Institute of Telecommunications                     Page Number          : 13 of 17
TEL: +86 21 63843300 FAX: +86 21 63843301                      Report Issued Date   : Jul.09.2017


                             RF Test Report                         Report No.: I17D00219-SRD05



                                  High                30MHz~20GHz                     P

                                  Low                 30MHz~20GHz                     P

   WCDMA Band V                  Middle               30MHz~20GHz                     P

                                  High                30MHz~20GHz                     P


WCDMA BAND II Mode Channel 9262
Final result:

 Frequency        PMea                                    Peak ERP       Limit          Polarizatio
                              Pcl (dBm)      Ga (dBd)
   (MHz)          (dBm)                                     (dBm)       (dBm)               n


   3703.2          -49.3          6.6           6.2         -49.7          -13               V


    5560          -56.95          8.2           9.7        -55.45          -13               V


   7691.6          -61.2          9.8          15.2         -55.8          -13               H


   9730.4           -60           10.9         18.2         -52.7          -13               H


  12292.55        -53.43          12.7         17.7        -48.43          -13               H


  14412.15        -56.21          13.9         23.2        -46.91          -13               H


WCDMA BAND II Mode Channel 9400
Final result:

 Frequency        PMea                                   Peak ERP       Limit         Polarizatio
                             Pcl (dBm)       Ga (dBd)
   (MHz)          (dBm)                                    (dBm)       (dBm)              n


   3758.4         -51.01          6.6          6.2        -51.41          -13              H


   5642.8         -57.8           8.3          10.1         -56           -13              V


   7468.4         -60.51          9.7          14.5       -55.71          -13              H


    9390          -61.75         10.7          18.6       -53.85          -13              V


   11770           -54           12.5          17.6        -48.9          -13              H


East China Institute of Telecommunications                   Page Number          : 14 of 17
TEL: +86 21 63843300 FAX: +86 21 63843301                    Report Issued Date   : Jul.09.2017


                             RF Test Report                       Report No.: I17D00219-SRD05



  13398.9         -56.76         13.7          22.8      -47.66          -13              V

WCDMA BAND II Mode Channel 9538
Final result:
 Frequenc
                 PMea                                   Peak ERP      Limit          Polarizatio
     y                      Pcl (dBm)        Ga (dBd)
                 (dBm)                                    (dBm)      (dBm)               n
  (MHz)

   3813.6        -49.57          6.7           6.4       -49.87          -13              V


    5720         -55.27          8.5           10.4      -53.37          -13              V


   7708.8        -61.47          9.8           15.2      -56.07          -13              V


    9590         -60.4          10.8           18.4       -52.8          -13              H


  11794.5        -54.26         12.5           17.5      -49.26          -13              H


 14863.65        -55.62         14.3           23.8      -46.12          -13              V




WCDMA BAND V Mode Channel 4132
Final result:

 Frequency        PMea                                  Peak ERP       Limit         Polarizatio
                             Pcl (dBm)       Ga (dBd)
   (MHz)          (dBm)                                   (dBm)       (dBm)              n

 1654.6428
                  -53.52          4.3           3.1      -54.72          -13              V
    57
 2481.5384
                  -50.24          5.3           3.7      -51.84          -13              V
    62

   3308.8         -48.64          6.2           5.1      -49.74          -13              V


    4284          -59.78          7.1           7.6      -59.28          -13              V


    6472          -59.49          8.9          11.4      -56.99          -13              H


   8292.4         -63.23         10.1          17.5      -55.83          -13              H

WCDMA BAND V Mode Channel 4183
Final result:

East China Institute of Telecommunications                  Page Number          : 15 of 17
TEL: +86 21 63843300 FAX: +86 21 63843301                   Report Issued Date   : Jul.09.2017


                             RF Test Report                         Report No.: I17D00219-SRD05



 Frequency        PMea                                   Peak ERP        Limit          Polarizatio
                               Pcl (dBm)     Ga (dBd)
   (MHz)          (dBm)                                    (dBm)        (dBm)               n

 1671.4285
                  -56.39          4.3          3.1         -57.59          -13               V
    71
 2513.0769
                  -53.29          5.4          3.7         -54.99          -13               V
    23

   3345.6         -52.57          6.2          5.3         -53.47          -13               V


   4259.2         -60.74          7.1          7.7         -60.14          -13               V


    6616          -59.82          9.1          11.9        -57.02          -13               V


   7583.2         -61.49          9.7          14.8        -56.39          -13               H


WCDMA BAND V Mode Channel 4233
Final result:

 Frequency        PMea                                   Peak ERP        Limit          Polarizatio
                              Pcl (dBm)      Ga (dBd)
   (MHz)          (dBm)                                    (dBm)        (dBm)               n


    1695           -52.4          4.4           3          -53.8           -13               V

 2542.6923
                  -49.26          5.4          3.8         -50.86          -13               V
    08

   3381.6         -52.22          6.3          5.5         -53.02          -13               V


   4822.8         -58.69          7.6          8.2         -58.09          -13               V


   5769.2         -60.42          8.5          10.5        -58.42          -13               H


   8415.4         -63.08          10.2         17.8        -55.48          -13               H


Conclusion: PASS
Note: the EUT was displayed in several different direction, the worst cases were shown.




East China Institute of Telecommunications                   Page Number          : 16 of 17
TEL: +86 21 63843300 FAX: +86 21 63843301                    Report Issued Date   : Jul.09.2017


                             RF Test Report                          Report No.: I17D00219-SRD05



ANNEX B.          Deviations from Prescribed Test Methods
No deviation from Prescribed Test Methods.

                                **********End The Report**********




East China Institute of Telecommunications                   Page Number          : 17 of 17
TEL: +86 21 63843300 FAX: +86 21 63843301                    Report Issued Date   : Jul.09.2017



Document Created: 2017-09-30 13:15:14
Document Modified: 2017-09-30 13:15:14

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC