RF Exposure report

FCC ID: 2ARER-SA10

RF Exposure Info

Download: PDF
FCCID_4476713

                          Test Report No.: HP190830DC001-FMP




                                                       RF Exposure report
                    Report No.: HP190830DC001-FWL

                          FCC ID: 2ARER-SA10

               Product Name Nooie Smart Power Strip

                    Test Model: SA10

               Received Date: N/A

                       Test Date: 2019-8-30~2019-9-18

                   Issued Date: 2019-9-30

            Applicant Name: Shenzhen Apeman Innovations Technology Co.,Ltd

        Applicant Address: Building P11, Huanancheng, Longgang District, Shenzhen, China

                      Issued By: Hwa-Hsing (Dongguan) Testing Co., Ltd.

                 Lab Address: No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang
                              Town, Dongguan, China

                Test Location: No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang
                               Town, Dongguan, China

            FCC Designation
                   Number: CN1255
                                        FCC Part 2 (Section 2.1091)
                     Standards:
                                        KDB 447498 D01
                                        IEEE C95.1

The above equipment has been tested by Hwa-Hsing (Dongguan) Testing Co., Ltd., and found compliance with
the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT)
configurations represented herein are true and accurate accounts of the measurements of the sample’s EMC
characteristics under the conditions specified in this report.




       Prepared by :                                                                        Date:               Sep. 30, 2019
                                             Tank Tan//Engineer




     Approved by :                                                                          Date:               Sep. 30, 2019
                                            Harry Li/ Supervisor
This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is
permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set
forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical
product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that
you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless
specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the
specification.The report must not be used by the client to claim product certification, approval, or endorsement by A2LA or any agency of the federal
government.The report must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.

                                                                                                        Tel: 0769-83078199
  Hwa-Hsing (Dongguan) Testing             No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial
                                                                                                        Web.: www.hwa-hsing.com
  Co., Ltd.                                Park, HuangJiang Town, Dongguan, China
                                                                                                        E-Mail: customerservice.dg@hwa-hsing.com
                                                                  Page 1 of     6                                           Report Version: V1.1.1


                   Test Report No.: HP190830DC001-FMP



                                               Table of contents

Release control record ............................................................................................... 3
1.    RF exposure limit ............................................................................................. 4
2.    MPE calculation formula .................................................................................. 4
3.    Calculation result of maximum conducted power............................................. 5
4.    Appendix – Information on the Testing Laboratories ........................................ 6




                                                                                 Tel: 0769-83078199
 Hwa-Hsing (Dongguan) Testing    No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial
                                                                                 Web.: www.hwa-hsing.com
 Co., Ltd.                       Park, HuangJiang Town, Dongguan, China
                                                                                 E-Mail: customerservice.dg@hwa-hsing.com
                                                    Page 2 of   6                                Report Version: V1.1.1


                  Test Report No.: HP190830DC001-FMP




                                             Release control record


Issue No.                      Reason for change                                                   Date issued
HP190830DC001-FMP              Original release                                                     Sep. 30, 2019




                                                                                Tel: 0769-83078199
Hwa-Hsing (Dongguan) Testing    No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial
                                                                                Web.: www.hwa-hsing.com
Co., Ltd.                       Park, HuangJiang Town, Dongguan, China
                                                                                E-Mail: customerservice.dg@hwa-hsing.com
                                                   Page 3 of   6                                Report Version: V1.1.1


                   Test Report No.: HP190830DC001-FMP




1. RF exposure limit

Limits for maximum permissible exposure (MPE)

                                Limits for general population / uncontrolled exposure
  Frequency range        Electric field strength Magnetic field strength          Power density            Average time
                                                                                           2
         (MHz)                   (V/m)                   (A/m)                     (mW/cm )                 (minutes)

      300-1500                      …                            …                   F/1500                      30
   1500-100,000                     …                            …                     1.0                       30

Note: F = Frequency in MHz


2. MPE calculation formula

Pd = (Pout*G) / (4*pi*r2)
Where:
                                   2
Pd = power density in mW/cm
Pout = output power to antenna in mW
G = gain of antenna in linear scale
Pi = 3.1416
R = distance between observation point and center of the radiator in cm


Classification:

The antenna of this product, under normal use condition, is at least 20cm away from the body of the
user.




                                                                                   Tel: 0769-83078199
 Hwa-Hsing (Dongguan) Testing     No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial
                                                                                   Web.: www.hwa-hsing.com
 Co., Ltd.                        Park, HuangJiang Town, Dongguan, China
                                                                                   E-Mail: customerservice.dg@hwa-hsing.com
                                                     Page 4 of   6                                 Report Version: V1.1.1


                   Test Report No.: HP190830DC001-FMP


3. Calculation result of maximum conducted power

The antennas provided to the EUT, please refer to the following table:
  Antenna                                                          Antenna Gain           Antenna            Transmit and
                 Function/ mode           Frequency Band
    No.                                                                 (dBi)               Type             Receive Chain

     1           2.4GHz WLAN             2400~2483.5MHz                  2.0           PCB Antenna              1TX,1RX


  Frequency band          Max power          Antenna gain             Distance         Power density              Limit
                                                                                                2                       2
      (MHz)                 (mW)                 (dBi)                  (cm)            (mW/cm )                (mW/cm )

  2400~2483.5MHz                9.2470              2                    20               0.02916                   1.0

Note: Determining compliance based on the results of the compliance measurement, not taking into
account measurement instrumentation uncertainty.




                                                                                   Tel: 0769-83078199
 Hwa-Hsing (Dongguan) Testing      No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial
                                                                                   Web.: www.hwa-hsing.com
 Co., Ltd.                         Park, HuangJiang Town, Dongguan, China
                                                                                   E-Mail: customerservice.dg@hwa-hsing.com
                                                      Page 5 of   6                                 Report Version: V1.1.1


                   Test Report No.: HP190830DC001-FMP




4. Appendix – Information on the Testing Laboratories

We, Hwa-Hsing (Dongguan) Co., Ltd.,A global provider of TESTING and CERTIFICATION services for
consumer products, electronic products and wireless information technology products. Adhering to the
core values “HONEST and TRUSTWORTHY, OBJECTIVE and IMPARTIALITY, RIGOROUS and
AFFICIENT”, commitment to provide professional, perfect and efficient comprehensive ONE-STOP
solution of TESTING and CERTIFICATION services for Manufacturers, Buyers, Traders, Brands,
Retailers. Assist client to better manage risk, protect their brands, reduce costs and cut time to over
150 markets in global. Our laboratories are FCC recognized accredited test firms and accredited and
approved according to ISO/IEC 17025.

If you have any comments, please feel free to contact us at the following:

Lab Address: No.101, Bld N1,Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang Town, Dongguan, China
Contact Tel: 0769-83078199
Email:customerservice.dg@hwa-hsing.com
Web Site:www.hwa-hsing.com




--- END ---




                                                                                Tel: 0769-83078199
 Hwa-Hsing (Dongguan) Testing   No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial
                                                                                Web.: www.hwa-hsing.com
 Co., Ltd.                      Park, HuangJiang Town, Dongguan, China
                                                                                E-Mail: customerservice.dg@hwa-hsing.com
                                                   Page 6 of   6                                Report Version: V1.1.1



Document Created: 2019-10-10 11:46:49
Document Modified: 2019-10-10 11:46:49

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC