MPE

FCC ID: 2ARER-PA10

RF Exposure Info

Download: PDF
FCCID_4381520

                               Intertek Testing Services Shenzhen Ltd.
                               Guangzhou Branch
                                                               Job No.: 190507011GZU-002
                                                               Page:                  1 of 2
                                                               FCC ID: 2ARER-PA10



 RF Exposure Compliance Requirement
1. Standard requirement
Systems operating under the provisions of this section shall be operated in a manner that ensures that the
public is not exposed to radio frequency energy level in excess limit for maximum permissible exposure. In
accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as a mobile
device whereby a distance of 0.2m normally can be maintained between the user and the device.
(a) Limits for Occupational / Controlled Exposure
                         Electric Field     Magnetic Field                               Averaging Times
 Frequency Range                                                  Power Density
                         Strength (E)         Strength (H)                                ‫׀‬E‫׀‬   2
                                                                                                    ,‫׀‬H‫ ׀‬2or S
        (MHz)                                                      (S)(mW/cm )    2
                             (V/m)               (A/m)
                                                                                               (minutes)
       0.3-3.0                614                 1.63                 (100)*                      6
       3.0-30                1842/f              4.89/f                (900/f)*                      6
       30-300                 61.4               0.163                   1.0                         6
      300-1500                 --                  --                  F/300                         6
    1500-100000                --                  --                     5                          6


(b) Limits for General Population / Uncontrolled Exposure
                         Electric Field     Magnetic Field                               Averaging Times
 Frequency Range                                                  Power Density
                         Strength (E)         Strength (H)                                ‫׀‬E‫׀‬   2
                                                                                                    ,‫׀‬H‫ ׀‬2or S
        (MHz)                                                      (S)(mW/cm2)
                             (V/m)               (A/m)
                                                                                               (minutes)
      0.3-1.34                614                 1.63                 (100)*                     30
       1.34-30               824/f               2.19/f                (180/f)*                     30
       30-300                 27.5               0.073                   0.2                        30
      300-1500                 --                  --                  F/1500                       30
    1500-100000                --                  --                    1.0                        30

Note: f=frequency in MHz; *Plane-wave equivalent power density


                              Intertek Testing Services Shenzhen Ltd.
                              Guangzhou Branch
                                                           Job No.: 190507011GZU-002
                                                           Page:           2 of 2
                                                           FCC ID: 2ARER-PA10

2. MPE Calculation Method
           E (V/m)=(30*P*G)0.5/d     Power Density: Pd(W/m2)=E2/377
           E=Electric Field (V/m)
           P=Peak RF output Power (W)
           G=EUT Antenna numeric gain (numeric)
           d= Separation distance between radiator and human body (m)
           The formula can be changed to
           Pd= (30*P*G)/(377*d2)
           From the peak EUT RF output power, the minimum mobile separation distance, d=0.2m, as
           well as the gain of the used antenna, the RF power density can be obtained.

           Output power=20dBm (max. value described by client)


3. Calculated Result and Limit
                                                                    Limit of
         Antenna    Peak Output
                                   Peak Output    Power Density      Power         Test
          Gain        Power
                                   Power (mW)      (S) (mW/cm2)    Density (S)    Result
        (Numeric)      (dBm)
                                                                   (mW/cm2)
          1.584          20          100.000          0.03153          1         Complies



Document Created: 2019-07-30 10:51:44
Document Modified: 2019-07-30 10:51:44