18_IPC100 RFExp

FCC ID: 2ARER-IPC100

RF Exposure Info

Download: PDF
FCCID_4239191

                            Shenzhen Toby Technology Co., Ltd.
                                                                         Report No.: TB-MPE164660
                                                                         Page:       1 of 4


             Maximum Permissible Exposure
                     Evaluation
                              FCC ID: 2ARER-IPC100
1. Client Information
Applicant         : Shenzhen Apeman Innovations Technology Co.,Ltd
Addres            : Building P11, Huanancheng, Longgang District, Shenzhen, China
Manufacturer : Shenzhen Apeman Innovations Technology Co.,Ltd
Address           : Building P11, Huanancheng, Longgang District, Shenzhen, China




                                                                                            TB-RF-075-1.0

         1A/F., Bldg.6, Yusheng Industrial Zone, The National Road No.107 Xixiang Section 467, Xixiang,
                                    Bao’an, Shenzhen, China
                                Tel: +86 75526509301       Fax: +86 75526509195


                            Shenzhen Toby Technology Co., Ltd.
                                                                         Report No.: TB-MPE164660
                                                                         Page:       2 of 4



2. General Description of EUT
EUT Name            : Nooie Cam 360
Models No.          : IPC100
Model
                    : N/A
Difference
                                                   802.11b/g/n(HT20): 2412MHz~2462MHz
                       Operation Frequency:
                                                   802.11n(HT40): 2422MHz~2452MHz
Product
                    : Max Output Power:            WIFI: 16.76dBm
Description
                       Antenna Gain:               0.63dBi PIFA Antenna
Power
                    : DC Voltage supplied by AC/DC Adapter
Supply
                      AC/DC Adapter (TPA-46B050100UU):
Power Rating        : Input: AC 100~240V, 50/60Hz, 0.2A.
                      Output: DC 5V, 1000mA.
Connecting          : Please refer to the User's Manual
I/O Port(S)




                                                                                            TB-RF-075-1.0

         1A/F., Bldg.6, Yusheng Industrial Zone, The National Road No.107 Xixiang Section 467, Xixiang,
                                    Bao’an, Shenzhen, China
                                Tel: +86 75526509301       Fax: +86 75526509195


                                                                          Report No.: TB-MPE164660
                                                                          Page:       3 of 4


                                 MPE Calculations for WIFI

1. Antenna Gain:
                    PIFA Antenna: 0.63dBi.

2. EUT Operation Condition:
   Software provided by client enabled the EUT to transmit and receive data at lowest, middle
   and highest channel individually.

3. Exposure Evaluation:
   Equation from page 18 of OET Bulletin 65, Edition 97-01
     S=(PG)/4πR2
   Where
      S: power density
      P: power input to the antenna
      G: power gain of the antenna in the direction of interest relative to an isotropic radiator.
      R: distance to the center of radiation of the antenna

4. Test Result:
                        Conducted                Max tune up                             Power
                                      Turn-up                  ANT Gain    Distance     Density
                        Power(max)                 power
          Mode                         Power                     (dBi)       (cm)              2
                          (dBm)                     (dBm)                              (mW/ cm )
                                        (dB)                      [G]         [R]
                                                      [P]                                 [S]

        802.11b          16.76        16±1          17          0.63         20        0.011528

        802.11g          15.61        15±1          16          0.63         20        0.009157

        802.11n
                         14.56        14±1          15          0.63         20        0.007273
         (HT20)
        802.11n
                         14.18        14±1          15          0.63         20        0.007273
         (HT40)




                                                                                       TB-RF-075-1.0


                                                                       Report No.: TB-MPE164660
                                                                       Page:       4 of 4


5. Conclusion:
As specified in Table 1B of 47 CFR 1.1310- Limits for Maximum Permissible Exposure (MPE),
                 Limits for General Population/ Uncontrolled Exposure
                        Frequency Range               Power density
                              (MHz)                     (mW/ cm2)
                            300-1,500                    F/1500
                          1,500-100,000                     1.0

  For 802.11b/g/n:2412~2462 MHz
  MPE limit S: 1mW/ cm2
  The MPE is calculated as 0.011528mW / cm2 < limit 1mW / cm2. So, RF exposure limit
  warning or SAR test are not required.

  The EUT will only be used with a separation of 20cm or greater between the antenna and
  nearby persons and can therefore be considered a mobile transmitter per 47 CFR2.1091
  (b).

  The RF Exposure Information page from the manual is included here for reference.


Note
   For a more detailed features description, please refer to the RF Test Report.




                                  -----END OF REPORT-----




                                                                                   TB-RF-075-1.0



Document Created: 2019-03-29 10:23:19