Test Report_DCD

FCC ID: 2ARDY-T511

Test Report

Download: PDF
FCCID_4189041

                         FCC TEST REPORT
                           FCC ID: 2ARDY-T511
                                   On Behalf of

               SHENZHEN DAK TECHNOLOGY CO.,LTD
                     Wireless Charger
Model No.: T511, T513, T517, T811C,T526, T527, T528, T516,
   T525, T532, T538, T539, T560, T561, T562, T563, T565,
       T567, T568 (T5xx: T5 followed by two numbers)




Prepared for       : SHENZHEN DAK TECHNOLOGY CO.,LTD
                     3-4/F, BLDG D, Demei Industrial CTR, Donghuan 2nd RD,
Address            :
                     Longhua St., Longhua District, Shenzhen, China




Prepared By        : Shenzhen Alpha Product Testing Co., Ltd.
                     Building i, No.2, Lixin Road, Fuyong Street, Bao'an District,
Address            :
                     518103, Shenzhen, Guangdong, China




                Report Number        :   T1890162 05
                Date of Receipt      :   January 24, 2019
                Date of Test         :   January 24, 2019-February 14, 2019
                Date of Report       :   February 14, 2019
                Version Number       :   REV0


                                                                  Page 2 of 25                                  Report No.: T1890162 05


                                                     TABLE OF CONTENTS

1. Test Result Summary .................................................................................. 5
2. General Information .................................................................................... 6
     2.1. DESCRIPTION OF DEVICE (EUT) ........................................................................................................... 6
     2.2. ACCESSORIES OF DEVICE (EUT) .......................................................................................................... 7
     2.3. TESTED SUPPORTING SYSTEM DETAILS ................................................................................................ 7
     2.4. BLOCK DIAGRAM OF CONNECTION BETWEEN EUT AND SIMULATORS ...................................................... 7
     2.5. DESCRIPTION OF TEST MODES ............................................................................................................. 7
     2.6. TEST CONDITIONS ............................................................................................................................... 7
     2.7. TEST FACILITY .................................................................................................................................... 8
     2.8. MEASUREMENT UNCERTAINTY ............................................................................................................. 8
     2.9. TEST EQUIPMENT LIST ......................................................................................................................... 9

3. Test Results and Measurement Data ...................................................... 10
     3.1. CONDUCTED EMISSION ...................................................................................................................... 10
     3.2. RADIATED SPURIOUS EMISSION MEASUREMENT .................................................................................. 14
     3.3. TEST SPECIFICATION ......................................................................................................................... 21

4. Photos of test setup .................................................................................. 23
5. Photographs of EUT .................................................................................. 25


                                       Page 3 of 25               Report No.: T1890162 05


                       TEST REPORT DECLARATION
Applicant         : SHENZHEN DAK TECHNOLOGY CO.,LTD
                    3-4/F, BLDG D, Demei Industrial CTR, Donghuan 2nd RD, Longhua
Address           :
                    St., Longhua District, Shenzhen, China
Manufacturer      : SHENZHEN DAK TECHNOLOGY CO.,LTD
                    3-4/F, BLDG D, Demei Industrial CTR, Donghuan 2nd RD, Longhua
Address           :
                    St., Longhua District, Shenzhen, China
EUT
                  : Wireless Charger
Description
                                             T511, T513, T517, T811C,T526, T527, T528,
                                             T516, T525, T532, T538, T539, T560, T561,
                     (A)   Model No.       :
                                             T562, T563, T565, T567, T568
                                             (T5xx: T5 followed by two numbers)
                     (B)   Trademark       : CHOETECH


Measurement Standard Used:
FCC CFR Title 47 Part 15 Subpart C Section 15.209


The device described above is tested by Shenzhen Alpha Product Testing Co., Ltd. to
determine the maximum emission levels emanating from the device and the severe levels
of the device can endure and its performance criterion. The test results are contained in
this test report and Shenzhen Alpha Product Testing Co., Ltd. is assumed full
responsibility for the accuracy and completeness of test. Also, this report shows that the
EUT is technically compliant with the FCC CFR Title 47 Part 15 Subpart C Section
15.209 requirements.


This report applies to above tested sample only. This report shall not be reproduced in
parts without written approval of Shenzhen Alpha Product Testing Co., Ltd.




                                           Reak Yang
Tested by (name + signature)........…..:
                                           Project Engineer
                                                                ……………………………

                                           Simple Guan
Approved by (name + signature)…....:
                                           Project Manager
                                                                ……………………………

Date of issue…… …………………..:                 February 14, 2019


                                     Page 4 of 25            Report No.: T1890162 05



                               Revision History
Revision      Issue Date                 Revisions                Revised By
  00       February 14, 2019        Initial released Issue       Simple Guan


                                                      Page 5 of 25          Report No.: T1890162 05


1. Test Result Summary

           Requirement                                  CFR 47 Section              Result

     Antenna requirement                                     §15.203                 PASS

  AC Power Line Conducted
                                                             §15.207                 PASS
        Emission

      Spurious Emission                                    §15.209(a)(f)             PASS

     Occupied Bandwidth                                    §15.215 (c)               PASS
 Note:
    1. PASS: Test item meets the requirement.

    2. Fail: Test item does not meet the requirement.

    3. N/A: Test case does not apply to the test object.

    4. The test result judgment is decided by the limit of test standard.


                                    Page 6 of 25              Report No.: T1890162 05


2. General Information
2.1. Description of Device (EUT)
EUT Name              :   Wireless Charger


Model No.             :   T511, T513, T517, T811C,T526, T527, T528, T516, T525,
                          T532, T538, T539, T560, T561, T562, T563, T565, T567,
                          T568 (T5xx: T5 followed by two numbers)
                          There is no difference between all the models, except the
DIFF.                 :   appearance color and model number, this report performs
                          the model T511.

Trademark             :   CHOETECH


Power supply          :   Input: 5V/2A
                          Output: 5W

Operation frequency   :   125-205KHz


Modulation            :   MSK


Antenna Type          :   Coil Antenna, Maximum Gain is 28dBi


Software version      :   V1.0

Hardware version      :   V3.0


                                                   Page 7 of 25                      Report No.: T1890162 05




2.2. Accessories of Device (EUT)
Accessories1        :    /
Manufacturer             /
Model                    /
Ratings                  /

2.3. Tested Supporting System Details
                                                                                            Certification or
  No.        Description Manufacturer                Model              Serial Number              poc

   1             Load                ——                  ——                     ——                   ——
   2           Adapter               ——        A138A120150                      ——                   ——


 2.4. Block Diagram of connection between EUT and simulators
                                     Load




                                     EUT     [~7   Adapter     > AC 120V/60Hz




 2.5. Description of Test Modes
Channel         Frifl:‘i’;cy   Channel       Fr?flfiz’;cy        Channel     Fr?%fi;cy      Channel     Fr?%‘fz';cy

       1           125           6             150              11           175           16             200
       2           130           7             155              12           180           17             205
       3           135           8             160              13           185           18
       4           140           9             165              14           190           19
       5           145          10             170              15           195           20
 Note: Pre—San all output power mode, and only worst data listed in report (DC 5V/1A).

 2.6. Test Conditions
                 Items                                   Required                               Actual
           Temperature range:                             15—35°C                                 27°C
            Humidity range:                              25—75%                                   56%
            Pressure range:                            86—106kPa                                980kPa


                                       Page 8 of 25              Report No.: T1890162 05




2.7. Test Facility
Shenzhen Alpha Product Testing Co., Ltd
Building i, No.2, Lixin Road, Fuyong Street, Bao'an District, 518103, Shenzhen, Guangdong,
China

June 21, 2018 File on Federal Communication Commission
Registration Number: 293961

July 25, 2017 Certificated by IC
Registration Number: 12135A


2.8. Measurement Uncertainty
(95% confidence levels, k=2)
                          Item                              MU            Remark
        Uncertainty for Conducted Emission Test            2.74dB

 Uncertainty for Radiation Emission test in 3m chamber     3.77dB       Polarize: V
                   (30MHz to 1GHz)                         3.80dB       Polarize: H

 Uncertainty for Radiation Emission test in 3m chamber     4.16dB       Polarize: H
                   (1GHz to 25GHz)                         4.13dB       Polarize: V
             Uncertainty for radio frequency              5.4×10-8
          Uncertainty for conducted RF Power               0.37dB


                                            Page 9 of 25               Report No.: T1890162 05




2.9. Test Equipment List

 Equipment Manufacture             Model No.           Serial No.      Last cal.    Cal Interval
     3m
              ETS-LINDGREN            N/A                  SEL0017     2018.09.21      1Year
Semi-Anechoic
   Spectrum
                     Agilent         E4407B           MY46185649       2018.09.21      1Year
   analyzer

   Receiver           R&S             ESCI         1166.5950K03-1011   2018.09.21      1Year

   Receiver           R&S             ESCI                 101202      2018.09.21      1Year

Bilog Antenna     Schwarzbeck      VULB 9168         VULB9168-438      2018.04.13      2Year

 Active Loop      SCHWARZBEC
                                   FMZB 1519B               00059      2018.09.26      2Year
  Antenna             K

    Cable          Resenberger        N/A                    No.1      2018.09.21      1Year

                  SCHWARZBEC
    Cable                             N/A                    No.2      2018.09.21      1Year
                      K
                  SCHWARZBEC
    Cable                             N/A                    No.3      2018.09.21      1Year
                      K

 Pre-amplifier    Schwarzbeck       BBV9743                9743-019    2018.09.21      1Year

                                 AFS33-18002650-
 Pre-amplifier        R&S                                  SEL0080     2018.09.21      1Year
                                    30-8P-44
 Temperature
                     Terchy           MHQ                    120       2018.09.21      1Year
  controller

  L.I.S.N.#1      Schwarzbeck       NSLK8126               8126466     2018.09.21      1Year

                  ROHDE&SCHW
  L.I.S.N.#2                         ENV216                101043      2018.09.21      1 Year
                      ARZ

20db Attenuator    ICPROBING         IATS1                  82347      2018.09.21      1 Year


                                   Page 10 of 25                Report No.: T1890162 05


3. Test Results and Measurement Data
3.1. Conducted Emission
3.1.1. Test Specification

  Test Requirement:         FCC Part15 C Section 15.207
  Test Method:              ANSI C63.10:2013
  Frequency Range:          150 kHz to 30 MHz
  Receiver setup:           RBW=9 kHz, VBW=30 kHz, Sweep time=auto

                               Frequency range                Limit (dBuV)
                                    (MHz)             Quasi-peak        Average
  Limits:                          0.15-0.5            66 to 56*        56 to 46*
                                     0.5-5                56               46
                                     5-30                 60               50




  Test Setup:




  Test Mode:                Charging + Transmitting Mode
                            1. The E.U.T is connected to an adapter through a line
                               impedance stabilization network (L.I.S.N.). This
                               provides a 50ohm/50uH coupling impedance for the
                               measuring equipment.
                            2. The peripheral devices are also connected to the main
                               power through a LISN that provides a 50ohm/50uH
                               coupling impedance with 50ohm termination. (Please
  Test Procedure:
                               refer to the block diagram of the test setup and
                               photographs).
                            3. Both sides of A.C. line are checked for maximum
                               conducted interference. In order to find the maximum
                               emission, the relative positions of equipment and all of
                               the interface cables must be changed according to
                               ANSI C63.10: 2013 on conducted measurement.
  Test Result:              PASS


                                        Page 11 of 25            Report No.: T1890162 05


3.1.2. Test data

                      Please refer to following diagram for individual

Test Mode      : Full Load
Test Results : PASS
Note:   The test results are listed in next pages.
        This mode is worst case mode, so this report only reflected the worst mode.
        If the limits for the measurement with the average detector are met when using a
        receiver with a peak detector, the test unit shall be deemed to meet both limits
        and the measurement with the average detector and quasi-peak detector need
        not be carried out.
        If the limits for the measurement with the average detector are met when using a
        receiver with a quasi-peak detector, the test unit shall be deemed to meet both
        limits and the measurement with the average detector need not be carried out.


                                                       Conducted Emission Measurement
           File :2019                                      Data #4                       Date: 2019—1—25              Time: 13:45:59
       80.0      dBuv


      70

                                                                                                       FCC Part 15 CLASS B QP
      60                                                                                              oT

                                                                                                      FCC Part 15 CLASS B AV
      50                                                                                              o

      40
                                                                                                                 i
                                    2
      30                                               5             a        5

      20
                                                                                                                                            peak


      10                                                                                                                                    lave
       0.0
         0.150                          05                                (MHz]                       5                                30.000
                           Reading           Correct        Measure—      _       _          .
 No. Mk.          Freq.     Level            Factor           ment       Limit        Margin
                   MHz       dBuV             d8              dBuV        dBuV          dB       Detector   Comment

  1              0.1530     36.15             9.66           45.81       65.84 —20.03              peak
  2              0.4650     22.62             9.71           32.33       56.60 —24.27              peak
  3              0.8280     16.10             9.74           25.84       56.00 —30.16              peak
  4              1.2390     15.61             9.79           25.40       56.00 —30.60              peak
  5              1.8600     17.05             9.87           26.92       56.00 —29.08              QP
  6              1.8600     11.67             9.87           21.54       46.00 —24.46              AVG
  7              9.9180     26.25            10.32           36.57       60.00 —23.43              QP
  8 *            9.9180     19.99            10.32           30.31       50.00 —19.69              AVG




*:Maximum data            x:Overlimit         L:over margin
Note: Measurement=Reading Level+Correc Factor.                           Factor=(LISN or ISN or PLC or Current Probe)Factor+Cable


                                                     Conducted Emission Measurement
            File :2019                               Data #3                   Date: 2019—1—25              Time: 13:42:48

        80.0      dBuv


       70
            \
                                                                                            FCC Part 15 CLASS B OP
       60                                                                                   o
            \
                                                                                            FCC Part 15 CLASS B AV
       50                                                                                   o


       40
             \j

       30
                                                               3     d                                                       8

       20
                                                                                                                                  peak

       10
                                                                                                                                  lave
        0.0
          0.150                       05                            (MHz]                   5                                30.000
                            Reading        Correct    Measure—      _ _            .
 No. Mk.           Freq.      Level        Factor       ment       Limit    Margin
                    MHz       dBuV          d8          dBuV        dBuV      dB       Detector   Comment

  10    *         0.1530     37.39          9.66       47.05       65.84 —18.79          peak
  2               0.2070     32.05          9.67       41.72       63.32 —21.60          peak
  3               1.4460      16.17         9.82       25.99       56.00 —30.01          peak
  4               1.8600      16.00         9.87       25.87       56.00 —30.13          QP
  5               1.8600      10.98         9.87       20.85       46.00 —25.15          AVG
  6               9.9090     24.82         10.32       35.14       60.00 —24.86          QP
  7               9.9090      18.04        10.32       28.36       50.00 —21.64          AVG
  8            24.1709        14.59        10.72       25.31       60.00 —34.69          peak




*:Maximum data             x:Over limit     L:over margin
Note: Measurement=Reading Level+Correc Factor.                     Factor=(LISN or ISN or PLC or Current Probe)Factor+Cable


                                   Page 14 of 25                        Report No.: T1890162 05



3.2. Radiated Spurious Emission Measurement
3.2.1. Test Specification

  Test Requirement:         FCC Part15 C Section 15.209
  Test Method:              ANSI C63.10: 2013
  Frequency Range:          9 kHz to 25 GHz
  Measurement Distance:     3m
  Antenna Polarization:     Horizontal & Vertical
  Operation mode:           Refer to item 4.1
                              Frequency       Detector        RBW        VBW        Remark
                             9kHz- 150kHz    Quasi-peak      200Hz       1kHz   Quasi-peak Value
                               150kHz-       Quasi-peak       9kHz      30kHz   Quasi-peak Value
  Receiver Setup:               30MHz
                             30MHz-1GHz      Quasi-peak     100KHz     300KHz   Quasi-peak Value
                                               Peak          1MHz       3MHz      Peak Value
                             Above 1GHz
                                               Peak          1MHz       10Hz     Average Value

                                                             Field Strength       Measurement
                                   Frequency
                                                           (microvolts/meter)   Distance (meters)
                                  0.009-0.490                 2400/F(KHz)              300
                                  0.490-1.705                24000/F(KHz)               30
                                   1.705-30                        30                   30
                                     30-88                        100                   3
                                     88-216                       150                   3
  Limit:                            216-960                       200                   3
                                  Above 960                       500                   3

                                                                       Measurement
                                                   Field Strength
                                 Frequency                               Distance      Detector
                                                 (microvolts/meter)
                                                                         (meters)
                                                          500                3         Average
                               Above 1GHz
                                                          5000               3          Peak

                            For radiated emissions below 30MHz




  Test setup:




                            30MHz to 1GHz


                        Page 15 of 25                Report No.: T1890162 05




                  Above 1GHz




                  1. For the radiated emission test below 1GHz:
                      The EUT was placed on a turntable with 0.8 meter
                      above ground. The EUT was set 3 meters from the
                      interference receiving antenna, which was mounted
                      on the top of a variable height antenna tower. The
                      EUT was arranged to its worst case and then tune
                      the antenna tower (from 1 m to 4 m) and turntable
                      (from 0 degree to 360 degrees) to find the maximum
                      reading. A pre-amp and a high PASS filter are used
                      for the test in order to get better signal level.
                      For the radiated emission test above 1GHz:
                      Place the measurement antenna on a turntable with
Test Procedure:
                      1.5 meter above ground, which is away from each
                      area of the EUT determined to be a source of
                      emissions at the specified measurement distance,
                      while keeping the measurement antenna aimed at
                      the source of emissions at each frequency of
                      significant emissions, with polarization oriented for
                      maximum response. The measurement antenna
                      may have to be higher or lower than the EUT,
                      depending on the radiation pattern of the emission
                      and staying aimed at the emission source for
                      receiving the maximum signal. The final
                      measurement antenna elevation shall be that which


                       Page 16 of 25               Report No.: T1890162 05


                    maximizes the emissions. The measurement
                    antenna elevation for maximum emissions shall be
                    restricted to a range of heights of from 1 m to 4 m
                    above the ground or reference ground plane.
                2. Corrected Reading: Antenna Factor + Cable Loss +
                    Read Level - Preamp Factor = Level
                3. For measurement below 1GHz, If the emission level
                    of the EUT measured by the peak detector is 3 dB
                    lower than the applicable limit, the peak emission
                    level will be reported. Otherwise, the emission
                    measurement will be repeated using the quasi-peak
                    detector and reported.
                4. Use the following spectrum analyzer settings:
                   (1) Span shall wide enough to fully capture the
                        emission being measured;
                   (2) Set RBW=100 kHz for f < 1 GHz; VBW ≥        RBW;
                        Sweep = auto; Detector function = peak; Trace =
                        max hold;
                   (3) Set RBW = 1 MHz, VBW= 3MHz for f  1 GHz
                        for peak measurement.
                    For average measurement: VBW = 10 Hz, when
                    duty cycle is no less than 98 percent. VBW ≥1/T,
                    when duty cycle is less than 98 percent where T is
                    the minimum transmission duration over which the
                    transmitter is on and is transmitting at its maximum
                    power control level for the tested mode of operation.
Test mode:      Refer to section 4.1 for details
Test results:   PASS


                                           Page 17 of 25                  Report No.: T1890162 05




3.2.2. Test Data
                             Please refer to following diagram for individual

Frequency
                   : 9KHz~30MHz
Range
Test Mode          : TX: channel low, channel mid, channel high
Test Results       : PASS
Note:   1. The test results are listed in next pages.
        2. This mode is worst case mode, so this report only reflected the worst mode.
        3. If the limits for the measurement with the average detector are met when using
        a receiver with a peak detector, the test unit shall be deemed to meet both limits
        and the measurement with the quasi-peak detector need not be carried out.

                   Antenna    Cable     Amp
Freq.   Reading                                    Result      Limit     Margin            State
                    Factor     loss    Factor                                     Detect
                                                             (dBuV/m)              or
(MHz)   (dBuV/m)     dB/m       dB       dB      (dBuV/m)                 (dB)              P/F
                                                               at 3 m
0.125    24.10       48.34     0.16     29.87      42.73      126.77     -11.27    PK      PASS
0.125    18.76       48.34     0.16     29.87      37.39      106.77     -16.61    AV      PASS
0.175    92.59       48.34     0.16     29.87     111.22      122.95     -11.73    PK      PASS
0.175    69.33       48.34     0.16     29.87      87.96      102.95     -14.99    AV      PASS
0.205    49.29       48.38     0.17     29.89      67.95      120.76     -52.81    PK      PASS
0.205    46.15       48.38     0.17     29.89      64.81      100.76     -35.95    AV      PASS
0.35     44.93       48.44     0.19     29.89      63.67      117.78     -54.11    PK      PASS
0.35     42.62       48.44     0.19     29.89      61.36       97.78     -36.42    AV      PASS
0.45     45.55       48.47     0.19     29.89      64.32      115.35     -51.03    PK      PASS
0.45     42.27       48.47     0.19     29.89      61.04       95.35     -34.31    AV      PASS
1.928    18.31       49.12      0.2     29.94      37.69        60       -22.31    QP      PASS
1.920    21.81       49.12      0.2     29.94      41.19        60       -18.81    QP      PASS


                                        Page 18 of 25              Report No.: T1890162 05



Frequency
                   :     30MHz~1000MHz
Range
Test Mode          : Full Load
Test Results       : PASS
Note:   1. The test results are listed in next pages.
        2. This mode is worst case mode, so this report only reflected the worst mode.
        3. If the limits for the measurement with the average detector are met when using
        a receiver with a peak detector, the test unit shall be deemed to meet both limits
        and the measurement with the quasi-peak detector need not be carried out.



Frequency
                   :     Above 1GHz
Range
EUT                : /                                     Test Date     :         /
M/N                : /                                   Temperature     :         /
Test Engineer      : /                                     Humidity      :         /
Test Mode          : /
Test Results      : N/A
       1. The highest frequency of the internal sources of the EUT is less than 108 MHz,
Note: the measurement shall only be made up to 1 GHz. So the frequency rang above
       1GHz radiation test not applicable.


                                          Page 19 of 25   Report No.: T1890162 05

Test result for Channel 125KHz, AC 120V/ 60Hz
                                          30MHz-1GHz
Horizontal:


                                                 Page 20 of 25                       Report No.: T1890162 05

Test result for Channel 125KHz, AC 120V/ 60Hz
Vertical:




Note:
   Emission Level=Peak Reading + Correction Factor; Correction Factor= Antenna Factor + Cable loss – Pre-amplifier


                                     Page 21 of25                Repor No: Tiecoree 0s

3.3.     Test Specification
       Test Requirement:      FCC Part15 C Section 15.215(c)
       Test Method:           ANSICS3.10: 2013
       Limit:                 NA
                              1. According to Ts fallow Test—salup, keep ns relalive
                                  posiion between the artficial anterna and the EUT.
                              2. Set to the maximum power sefling and enable the
                                  EUT transmit continuously.
                              3. Use the following spectrum analyzer seltings for
       Test Procedure:            200B Bandwidih measurement.
                                 Span = approximately 2 to 3 times the 20 dB
                                  bandwicth, centered on a hopging channel; RBW>
                                  1%of the 20 dB bandwicth; VBW=RBW; Sweep =
                                  auto; Detector function = peak; Trace = max hold.
                              4. Measure and record the resultsin the test report.

       Test setup:
                              Spectrum Anarzer                   en
       Test Mode:             Refer to section 4.1 for details
       Test results:          PASS


                                      Page 22 of 25             Report No.: T1890162 05



3.3.1. Test data
                            20dB Occupy
    Frequency(KHz)                                Limit (kHz)        Conclusion
                           Bandwidth (kHz)
           175.0               27.26                  ---               PASS

  Test plots as follows:


                                     Lowest channel


                            Page 23 of 25   Report No.: T1890162 05


4.   Photos of test setup
     Radiated Emission




                                     Page 25 of 25               Report No.: T1890162 05


5. Photographs of EUT
   Please refer to separated files for External Photos & Internal Photos of the EUT.



                                      ------End------



Document Created: 2019-02-28 08:34:56
Document Modified: 2019-02-28 08:34:56