RF EXPOSURE_T1890162 06_EMF_V1.0

FCC ID: 2ARDY-T511

Test Report

Download: PDF
FCCID_4189039

                         FCC TEST REPORT
                          FCC ID: 2ARDY-T511
                                   On Behalf of

               SHENZHEN DAK TECHNOLOGY CO.,LTD
                     Wireless Charger
Model No.: T511, T513, T517, T811C,T526, T527, T528, T516,
   T525, T532, T538, T539, T560, T561, T562, T563, T565,
       T567, T568 (T5xx: T5 followed by two numbers)




Prepared for       : SHENZHEN DAK TECHNOLOGY CO.,LTD
                     3-4/F, BLDG D, Demei Industrial CTR, Donghuan 2nd RD,
Address            :
                     Longhua St., Longhua District, Shenzhen, China




Prepared By        : Shenzhen Alpha Product Testing Co., Ltd.
                     Building i, No.2, Lixin Road, Fuyong Street, Bao'an District,
Address            :
                     518103, Shenzhen, Guangdong, China




                Report Number        :   T1890162 06
                Date of Receipt      :   January 24, 2019
                Date of Test         :   January 24, 2019-February 14, 2019
                Date of Report       :   February 14, 2019
                Version Number       :   REV0


                                                                  Page 2 of 13                                      Report No.: T1890162 06


                                                     TABLE OF CONTENTS

1. Test Result Summary .................................................................................. 5
2. EUT Description ........................................................................................... 6
     2.1. DESCRIPTION OF DEVICE (EUT) ........................................................................................................... 6
     2.2. ACCESSORIES OF DEVICE (EUT) .......................................................................................................... 7
     2.3. TESTED SUPPORTING SYSTEM DETAILS ................................................................................................ 7
     2.4. BLOCK DIAGRAM OF CONNECTION BETWEEN EUT AND SIMULATORS ...................................................... 7
     2.5. DESCRIPTION OF TEST MODES ............................................................................................................. 7
     2.6. TEST CONDITIONS ............................................................................................................................... 7
     2.7. TEST FACILITY .................................................................................................................................... 8
     2.8. MEASUREMENT UNCERTAINTY ............................................................................................................. 8

3. Test Results and Measurement Data ........................................................ 9
     3.1. RF EXPOSURE TEST ....................................................................................................................... 9

4. Photos of test setup .................................................................................. 12
5. Photographs of EUT .................................................................................. 13


                                           Page 3 of 13             Report No.: T1890162 06


                        TEST REPORT DECLARATION
Applicant           : SHENZHEN DAK TECHNOLOGY CO.,LTD
                        3-4/F, BLDG D, Demei Industrial CTR, Donghuan 2nd RD, Longhua
Address             :
                        St., Longhua District, Shenzhen, China
Manufacturer        : SHENZHEN DAK TECHNOLOGY CO.,LTD
                        3-4/F, BLDG D, Demei Industrial CTR, Donghuan 2nd RD, Longhua
Address             :
                        St., Longhua District, Shenzhen, China
EUT Description     : Wireless Charger
                                               T511, T513, T517, T811C,T526, T527, T528,
                                               T516, T525, T532, T538, T539, T560, T561,
                        (A)   Model No.      :
                                               T562, T563, T565, T567, T568
                                               (T5xx: T5 followed by two numbers)
                        (B)   Trademark      : CHOETECH


Measurement Standard Used:
FCC CFR Title 47 Part 15 Subpart C


The device described above is tested by Shenzhen Alpha Product Testing Co., Ltd. to
determine the maximum emission levels emanating from the device and the severe levels
of the device can endure and its performance criterion. The test results are contained in
this test report and Shenzhen Alpha Product Testing Co., Ltd. is assumed full
responsibility for the accuracy and completeness of test. Also, this report shows that the
EUT is technically compliant with the FCC CFR Title 47 Part 15 Subpart C requirements.


This report applies to above tested sample only. This report shall not be reproduced in
parts without written approval of Shenzhen Alpha Product Testing Co., Ltd.




                                               Reak Yang
Tested by (name + signature)........…..:
                                               Project Engineer
                                                                   ……………………………

                                               Simple Guan
Approved by (name + signature)…....:
                                               Project Manager
                                                                   ……………………………

Date of issue…… …………………..:                     February 14, 2019


                                     Page 4 of 13            Report No.: T1890162 06



                               Revision History
Revision      Issue Date                 Revisions              Revised By
  00       February 14, 2019        Initial released Issue     Simple Guan


                                                      Page 5 of 13          Report No.: T1890162 06


1. Test Result Summary

           Requirement                                  CFR 47 Section            Result

         RF EXPOSURE                           §1.1307(b)(1) & KDB680106           PASS
 Note:
    1. PASS: Test item meets the requirement.

    2. Fail: Test item does not meet the requirement.

    3. N/A: Test case does not apply to the test object.

    4. The test result judgment is decided by the limit of test standard.


                                       Page 6 of 13                   Report No.: T1890162 06


2. EUT Description
2.1. Description of Device (EUT)
EUT Name                :    Wireless Charger

Model No.               :    T511, T513, T517, T811C,T526, T527, T528, T516, T525,
                             T532, T538, T539, T560, T561, T562, T563, T565, T567,
                             T568 (T5xx: T5 followed by two numbers)
                             There is no difference between all the models, except the
DIFF.                   :    appearance color and model number, this report performs
                             the model T511.

Trademark               :    CHOETECH

Power supply            :    Input: 5V/2A
                             Output: 5W

Operation frequency     :    125-205KHz


Modulation              :    MSK


Antenna Type            :    Coil Antenna, Maximum Gain is 28dBi


Software version        :    V1.0
Hardware version        :    V3.0


           Conditions requirement                                    Answers
Power transfer frequency is less that 1 MHz           After measuring the product the
                                                      transfer frequency is 125-205KHz
Output power from each primary coil is less than      After measuring the product the each
15 watts                                              primary coil power is 5 watts
The transfer system includes only single primary      The transfer system includes only
and secondary coils. This includes charging           single primary.
systems that may have multiple primary coils
and clients that are able to detect and allow
coupling only between individual pairs of oils
Client device is inserted in or placed directly in    Client device is placed directly in
contact with the transmitter                          contact with the transmitter
Aggregate leakage fields at 15 cm surrounding         After measuring the product the Max
the device from all simultaneous transmitting         E-Filed Strength is 0.34V/m Far less
coils are demonstrated to be less than 50% of         than 50% of the MPE limit.
the MPE limit.


                                                        Page 7 of 13                             Report No.: 1890162 06




2.2. Accessories of Device (EUT)
Accessories1          _:   /
Manufacturer               /
Model                      /
Ratings                    /


2.3. Tested Supporting System Details
  No.        Description          Manufacturer                    Model        Serial Number          Cemfll:;:oagon or

   1             Load                     ——                        ——                  ——                     ——
   2           Adapter                    ——             A138A120150                    ——                     ——


 2.4. Block Diagram of connection between EUT and simulators

                                    Load



                                    EUT                 Adapter          > AC 120V/60Hz




 2.5. Description of Test Modes
Channel         Fr(-z&lfiezr)lcy   Channel      Fr(-z&l#-)zr)lcy     Channel     Fr(-z&:e;r)lcy    Channel     Frt-qu:ezr)lcy

       1            125              6              150                  11         175              16             200
       2            130              7              155                  12         180              17             205
       3            135              8              160                  13         185              18
       4            140              9              165                  14         190              19
       5            145             10              170                  15         195              20



 2.6. Test Conditions
                 Items                                            Required                                Actual
           Temperature range:                                     15—35°C                                   27°C
            Humidity range:                                       25—75%                                    56%
            Pressure range:                                   86—106kPa                                   980kPa


                                              Page 8 of 13                     Report No.: T1890162 06




2.7. Test Facility
Shenzhen Alpha Product Testing Co., Ltd
Building i, No.2, Lixin Road, Fuyong Street, Bao'an District, 518103, Shenzhen, Guangdong, China

June 21, 2018 File on Federal Communication Commission
Registration Number: 293961

July 25, 2017 Certificated by IC
Registration Number: 12135A



2.8. Measurement Uncertainty
(95% confidence levels, k=2)
                                   Item                                         Uncertainty

           Uncertainty for Conducted Emission Test                                  2.74dB

   Uncertainty for Radiation Emission test in 3m chamber                            3.77dB
                     (30MHz to 1GHz)                                               3.80dB
   Uncertainty for Radiation Emission test in 3m chamber                           4.16dB
                      (1GHz to 25GHz)                                              4.13dB
               Uncertainty for radio frequency                                     5.4×10-8
         Uncertainty for Conducted Emission Test                                   2.74dB
   Uncertainty for Radiation Emission test in 3m chamber
                                                                                    3.77dB
                     (30MHz to 1GHz)
           Uncertainty for conducted RF Power                                      0.65dB
                Uncertainty for temperature                                         0.2℃
                   Uncertainty for humidity                                          1%
      Uncertainty for DC and low frequency voltages                                0.06%


                                   Page 9 of 13                Report No.: T1890162 06


3.      Test Results and Measurement Data
3.1. RF EXPOSURE TEST
3.1.1. Test Specification

     Test Requirement:      FCC Rules and Regulations KDB680106
     Test Method:           §1.1307(b)(1) & KDB680106
                            According to §1.1307(b)(1), systems operating under the
                            provisions of this section shall be
                            operated in a manner that ensures that the public is not
                            exposed to radio frequency energy
     Limits:                level in excess of the Commission’s guidelines.
                            According to §1.1310 and §2.1093 RF
                            exposure is calculated. According KDB680106 D01v03:
                            RF Exposure Wireless Charging
                            Apps v02.




     Test Setup:




     Test Mode:             Charging + Transmitting Mode
                            1. The RF exposure test was performed on 360 degree
                               turn table in anechoic chamber.
                            2. The measurement probe was placed at test distance
                               (10cm) which is between the edge of the charger and
                               the geometric centre of probe.
                            3. The turn table was rotated 360d degree to search of
     Test Procedure:
                               highest strength.
                            4. The highest emission level was recorded and
                               compared with limit as soon as measurement of each
                               points (A, B, C, D, E) were completed.
                            5. The EUT were measured according to the dictates of
                               KDB 680106D01v03.
     Test Result:           PASS


                                Page 10 of 13                   Report No.: T1890162 06


3.1.2. Test Instruments
                                                                             Cal.
 Item Equipment Manufacturer    Model No.       Serial No.   Last Cal.
                                                                           Interval
        Van der
  1.                      MPB    MS-210           0019       2018.09.21     1 Year
        Hoofden


                                     Page 11 of 13               Report No.: T1890162 06



  3.1.3. Test data

For Full load mode:
E-Filed Strength at 15 cm from the edges surrounding the EUT (V/m)
Frequency Test          Test       Test       Test      Test     Reference   Limits
Range         Position Position    Position Position Position Limit          Test
(MHz)         A         B          C          D         E        (V/m)       (V/m)
0.205         0.33      0.34       0.32       0.31      0.31     184.2       614

H-Filed Strength at 15 cm from the edges surrounding the EUT (A/m)
Frequency Test          Test       Test      Test       Test     Reference   Limits
Range        Position Position     Position Position Position Limit          Test
(MHz)        A          B          C         D          E        (A/m)       (V/m)
0. 205       0.23       0.25       0.22      0.23       0.25     0.489       1.63

For half load mode:
E-Filed Strength at 15 cm from the edges surrounding the EUT (V/m)
Frequency Test          Test       Test       Test      Test     Reference   Limits
Range         Position Position    Position Position Position Limit          Test
(MHz)         A         B          C          D         E        (V/m)       (V/m)
0.175         0.23      0.24       0.27       0.26      0.27     184.2       614

H-Filed Strength at 15 cm from the edges surrounding the EUT (A/m)
Frequency Test          Test       Test      Test       Test     Reference   Limits
Range        Position Position     Position Position Position Limit          Test
(MHz)        A          B          C         D          E        (A/m)       (V/m)
0.175        0.11       0.10       0.12      0.11       0.11     0.489       1.63


For No load mode:
E-Filed Strength at 15 cm from the edges surrounding the EUT (V/m)
Frequency Test          Test       Test       Test      Test     Reference   Limits
Range        Position Position     Position Position Position Limit          Test
(MHz)        A          B          C          D         E        (V/m)       (V/m)
0.125        0.25       0.26       0.25       0.24      0.25     184.2       614

H-Filed Strength at 15 cm from the edges surrounding the EUT (A/m)
Frequency Test          Test       Test      Test       Test     Reference   Limits
Range        Position Position     Position Position Position Limit          Test
(MHz)        A          B          C         D          E        (A/m)       (V/m)
0.125        0.09       0.10       0.09      0.11       0.08     0.489       1.63


                          Page 12 of 13   Report No.: T1890162 06


4. Photos of test setup
For Full load mode




For No load mode


                                    Page 13 of 13     Report No.: T1890162 06


5. Photographs of EUT
    Refer to test report T1890162 05.

                                    ------End------



Document Created: 2019-02-28 08:34:30
Document Modified: 2019-02-28 08:34:30

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC