RF Exposure

FCC ID: 2ARD3-LL127

RF Exposure Info

Download: PDF
FCCID_4501526

                        Shenzhen Global Test Service Co.,Ltd.
                        No.7-101 and 8A-104, Building 7 and 8, DCC Cultural and Creative Garden, No.98, Pingxin North Road,
                        Shangmugu Community, Pinghu Street, Longgang District, Shenzhen, Guangdong




                                                            TEST REPORT

Report Reference No. ..................... :               GTS20191028006-1-1-2
FCC ID. ........................................... :      2ARD3-LL127
              Compiled by
( position+printed name+signature).. :                     File administrators Jimmy Wang


            Supervised by
( position+printed name+signature).. :                     Test Engineer Aaron Tan

              Approved by
( position+printed name+signature).. :                     Manager Jason Hu


Date of issue..................................... :       Oct. 23, 2019
Representative Laboratory Name .:                          Shenzhen Global Test Service Co., Ltd.

                                                           No.7-101 and 8A-104, Building 7 and 8, DCC Cultural and Creative
Address ............................................ :     Garden, No.98, Pingxin North Road, Shangmugu Community,
                                                           Pinghu Street, Longgang District, Shenzhen, Guangdong
Applicant’s name ............................ :            LEXON

Address ............................................ :     91 avenue Jean-Baptiste Clement 92100 Boulogne FRANCE
Test specification ...........................:

                                                           FCC Rules and Regulations part 2.1091
Standard ........................................... :
                                                           KDB680106 D01v03
TRF Originator .................................. :        Shenzhen Global Test Service Co.,Ltd.

Master TRF ....................................... :       Dated 2014-12

Shenzhen Global Test Service Co.,Ltd. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the
Shenzhen Global Test Service Co.,Ltd. is acknowledged as copyright owner and source of the material.
Shenzhen Global Test Service Co.,Ltd. takes no responsibility for and will not assume liability for damages
resulting from the reader's interpretation of the reproduced material due to its placement and context.
Test item description .....................:               BALI WIRELESS CHARGING PAD WITH BATTERY
Trade Mark ....................................... :       LEXON
Manufacturer .................................... :        LEXON
Model/Type reference....................... :              LL127
Listed Models .................................. :         N/A
Modulation Type ............................... :          ASK
Operation Frequency ........................ :             From 110KHz~205KHz

Rating ............................................... :   DC 3.7V from battery charged by DC 5V
Result................................................ :   PASS


Report No.: GTS20191028006-1-1-2                                                                               Page 2 of 11

                                   TEST REPORT
                                                                                           Oct. 23, 2019
 Test Report No. :                GTS20191028006-1-1-2              ____________________________________________________________________________________


                                                                                           Date of issue


   Equipment under Test      :     BALI WIRELESS CHARGING PAD WITH BATTERY


   Model /Type               :     LL127


   Listed Models             :     N/A


   Applicant                 :     LEXON


   Address                   :     91 avenue Jean-Baptiste Clement 92100 Boulogne FRANCE


   Manufacturer              :     LEXON


   Address                   :     91 avenue Jean-Baptiste Clement 92100 Boulogne FRANCE




                   Test Result:                                         PASS


   The test report merely corresponds to the test sample.
   It is not permitted to copy extracts of these test result without the written permission of the test
   laboratory.


    Report No.: GTS20191028006-1-1-2                                            Page 3 of 11

                                                  Contents

1         SUMMARY ............................................................................. 4

1.1  General Remarks                                                                           4
1.2  Product Description                                                                       4
1.3  Equipment under Test                                                                      错
误!未定义书签。
1.4  Modifications                                                                             4

2         TEST ENVIRONMENT............................................................... 5

2.1       Address of the test laboratory                                                       5
2.2       Test Facility                                                                        5
2.3       Environmental conditions                                                             5
2.4       Summary of measurement results                                                       6
2.5       Statement of the measurement uncertainty                                             6
2.6       Equipments Used during the Test                                                      6

3         TEST CONDITIONS AND RESULTS ............................................. 7

3.1       Applicable Standard                                                                  7
3.2       Limit                                                                                7
3.3       Test Setup                                                                           7
3.4       Measurement Procedure                                                                8
3.5       Test Result of E and H field Strength                                                8
3.6       Equipment Approval Considerations                                                    10
3.7       Conclusion                                                                           10

4         TEST SETUP PHOTOS OF THE EUT .......................................... 11


        Report No.: GTS20191028006-1-1-2                                                        Page 4 of 11

       1 SUMMARY

       1.1   General Remarks
       Date of receipt of test sample         :   Oct. 12, 2019


       Testing commenced on                   :   Oct. 13, 2019


       Testing concluded on                   :   Oct. 22, 2019

       1.2   Product Description
       Product Name:                    BALI WIRELESS CHARGING PAD WITH BATTERY
       Model/Type reference:            LL127
       Power supply:                    DC 3.7V from battery charged by DC 5V
                                        Mode:EP-TA20CBC
       Adapter(Auxiliary        test
                                        Input:AC100-240V-50/60Hz,0.5A
       Provided by the laborator)
                                        Output:DC 5V,2A
       Wireless Charger
       Antenna Type                     Coil Antenna
       Antenna Gain                     1.0dBi
       Operation frequency              110KHz~205KHz
       Modulation Type                  ASK
       Rated Output power               10W


       1.3   Description of the test mode
       Equipment under test was operated during the measurement under the following conditions:
         Charging and communication mode

Test Conditions Description                                                          Exposure conditions
      TM1        AC/DC Adapter + EUT + Mobile Phone (Battery Status: <1%)                Mobile  Portable      Record
      TM2        AC/DC Adapter + EUT + Mobile Phone (Battery Status: <50%)               Mobile  Portable      Record
      TM3        AC/DC Adapter + EUT + Mobile Phone (Battery Status: 100%)               Mobile  Portable      Record
      TM4        Charge from PC + EUT + Mobile Phone (Battery Status: <1%)               Mobile  Portable      Pre-tested
      TM5        Charge from PC + EUT + Mobile Phone (Battery Status: <50%)              Mobile  Portable      Pre-tested
      TM6        Charge from PC + EUT + Mobile Phone (Battery Status: 100%)              Mobile  Portable      Pre-tested
      TM7        EUT + Mobile Phone (Battery Status: <1%)                                Mobile  Portable      Record
      TM8        EUT + Mobile Phone (Battery Status: <50%)                               Mobile  Portable      Record
      TM9        EUT + Mobile Phone (Battery Status: 100%)                               Mobile  Portable      Record
Note: All test modes were pre-tested, but we only recorded the worst case in this report.


       1.4   Modifications
       No modifications were implemented to meet testing criteria.


 Report No.: GTS20191028006-1-1-2                                                           Page 5 of 11



2 TEST ENVIRONMENT

2.1   Address of the test laboratory
Shenzhen Global Test Service Co.,Ltd.
No.7-101 and 8A-104, Building 7 and 8, DCC Cultural and Creative Garden, No.98, Pingxin North Road,
Shangmugu Community, Pinghu Street, Longgang District, Shenzhen, Guangdong

The 3m-Semi anechoic test site fulfils CISPR 16-1-4 according to ANSI C63.4:2014 and CISPR 16-1-4:2010
SVSWR requirement for radiated emission above 1GHz.


2.2   Test Facility
The test facility is recognized, certified, or accredited by the following organizations:

FCC-Registration No.: 165725
Shenzhen Global Test Service Co.,Ltd EMC Laboratory has been registered and fully described in a report
filed with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is maintained
in our files.

A2LA-Lab Cert. No.: 4758.01

Shenzhen Global Test Service Co.,Ltd. EMC Laboratory has been accredited by A2LA for
technical competence in the field of electrical testing, and proved to be in compliance with ISO/IEC 17025:
2005 General Requirements for the Competence of Testing and Calibration Laboratories and any additional
program requirements in the identified field of testing.


CNAS-Lab Code: L8169
Shenzhen Global Test Service Co.,Ltd. has been assessed and proved to be in compliance with CNAS-
CL01 Accreditation Criteria for Testing and Calibration Laboratories (identical to ISO/IEC 17025: 2005
General Requirements) for the Competence of Testing and Calibration Laboratories. Date of Registration:
Dec. 11, 2015. Valid time is until Dec. 10, 2024.



2.3   Environmental conditions
During the measurement the environmental conditions were within the listed ranges:

  Temperature:                               15-35 °C

  Humidity:                                   30-60 %

  Atmospheric pressure:                   950-1050mbar


 Report No.: GTS20191028006-1-1-2                                                           Page 6 of 11

2.4     Summary of measurement results
                   Test Item                                Result
       Electric Field Strength (E) (V/m)                   Compliant
      Magnetic Field Strength (H) (A/m)                    Compliant


2.5     Statement of the measurement uncertainty
The data and results referenced in this document are true and accurate. The reader is cautioned that there
may be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was
calculated for all measurements listed in this test report acc. to CISPR 16 - 4 „Specification for radio
disturbance and immunity measuring apparatus and methods – Part 4: Uncertainty in EMC
Measurements“ and is documented in the Shenzhen Global Test Service Co.,Ltd quality system acc. to DIN
EN ISO/IEC 17025. Furthermore, component and process variability of devices similar to that tested may
result in additional deviation. The manufacturer has the sole responsibility of continued compliance of the
device.

Hereafter the best measurement capability for Shenzhen GTS laboratory is reported:
                                                                      Measurement
                       Test                        Range                               Notes
                                                                       Uncertainty
            Radiated Emission                  30~1000MHz                4.10 dB         (1)
            Radiated Emission                     1~18GHz                4.32 dB         (1)
            Radiated Emission                    18-40GHz                5.54 dB         (1)
            Conducted Disturbance               0.15~30MHz               3.12 dB         (1)
          (1) This uncertainty represents an expanded uncertainty expressed at approximately the 95%
              confidence level using a coverage factor of k=2.


2.6     Equipments Used during the Test

       Description           Brand         Model No.   Frequency Range    Calibrated Date     Calibrated Until


  Broadband Field
                                                                           Dec. 28, 2018      Dec. 27, 2019
       Meter                NARDA          NBM-550            -


Magnetic Field Meter                                                       Dec. 28, 2018      Dec. 27, 2019
                            NARDA          ELT-400       1 – 400kHz

  Magnetic Probe            NARDA          HF-3061     300kHz – 30MHz      Dec. 28, 2018      Dec. 27, 2019

  Magnetic Probe            NARDA          HF-0191      27 – 1000MHz       Dec. 28, 2018      Dec. 27, 2019

  Broadband Field
                            NARDA          NBM-550            -            Dec. 28, 2018      Dec. 27, 2019
       Meter

 Electric Field Meter    COMBINOVA         EFM 200      5Hz – 400kHz       Dec. 28, 2018      Dec. 27, 2019

      E-Field Probe         NARDA          EF-0391     100kHz – 3GHz       Dec. 28, 2018      Dec. 27, 2019

      E-Field Probe         NARDA          EF-6091     100MHz – 60GHz      Dec. 28, 2018      Dec. 27, 2019
Note: The Cal.Interval was one year.


 Report No.: GTS20191028006-1-1-2                                                          Page 7 of 11



3 TEST CONDITIONS AND RESULTS

3.1   Applicable Standard
According to §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a
manner that ensures that the public is not exposed to radio frequency energy level in excess of the
Commission’s guidelines.
According to §1.1310 and §2.1091 RF exposure is calculated.
According KDB 680106 D01 RF Exposure Wireless Charging App v03


3.2   Limit
Limits for Maximum Permissible Exposure (MPE)/Controlled Exposure

    Frequency            Electric Field          Magnetic Field        Power Density        Averaging Time
   Range(MHz)            Strength(V/m)           Strength(A/m)           (mW/cm²)              (minute)
                                  Limits for Occupational/Controlled Exposure
     0.3 – 3.0                614                     1.63                (100) *                   6
     3.0 – 30                1842/f                  4.89/f               (900/f)*                  6
     30 – 300                 61.4                   0.163                   1.0                    6
    300 – 1500                  /                       /                  f/300                    6
  1500 – 100,000                /                       /                     5                     6

Limits for Maximum Permissible Exposure (MPE)/Uncontrolled Exposure

    Frequency            Electric Field          Magnetic Field        Power Density        Averaging Time
   Range(MHz)            Strength(V/m)           Strength(A/m)           (mW/cm²)              (minute)
                                  Limits for Occupational/Controlled Exposure
     0.3 – 3.0                614                     1.63                (100) *                  30
     3.0 – 30                824/f                   2.19/f               (180/f)*                 30
     30 – 300                 27.5                   0.073                   0.2                   30
    300 – 1500                  /                       /                  f/1500                  30
  1500 – 100,000                /                       /                    1.0                   30

F=frequency in MHz
*=Plane-wave equivalent power density
3.3   Test Setup




Note: A, B, C, D, E, F for six surfaces of the product.


   Report No.: GTS20191028006-1-1-2                                                         Page 8 of 11

 3.4     Measurement Procedure
 For mobile RF exposure

 a) The RF exposure test was performed on 360 degree turn table in anechoic chamber.
 b) The measurement probe was placed at test distance (15cm) which is between the edge of the charger and
 the geometric center of probe.
 c) The turn table was rotated 360d degree to search of highest strength.
 d) The highest emission level was recorded and compared with limit as soon as measurement of each points
 (A, B, C, D, E) were completed.
 e) The EUT were measured according to the dictates of KDB 680106D01v03.

 For portable RF exposure

 a) The RF exposure test was performed on 360 degree turn table in anechoic chamber.
 b) The measurement probe was placed at test distance (0cm) which is between the edge of the charger and
 the geometric center of probe.
 c) The turn table was rotated 360d degree to search of highest strength.
 d) The highest emission level was recorded and compared with limit as soon as measurement of each points
 (A, B, C, D, E, F) were completed.
 e). Repeated measured (a) – (d) at measure distance 5cm, 10cm and 15cm.
 f) The EUT were measured according to the dictates of KDB 680106D01v03.


 3.5     Test Result of E and H field Strength
 3.5.1    For mobile exposure

 E-Field Strength at 15 cm from the edges surrounding the EUT and 15cm from the top surface of the EUT
                                                                                         FCC E-
                                           Measured E-Field Strength Values (V/m)                    FCC E-
                                                                                          Field
            Charging Frequency                                                                         Field
  Test                                                                                   Strength
             Battery      Range       Test       Test      Test       Test      Test                 Strength
Conditions                                                                                 50%
              Level       (MHz)      Position Position Position Position Position                     Limits
                                                                                          Limits
                                        A         B          C         D          E                   (V/m)
                                                                                          (V/m)
  TM1          1%         0.135       3.74      3.68       3.85      3.54       4.05          307.0        614.0

  TM2         50%         0.135       3.61      3.54       3.66      3.59       3.74          307.0        614.0

  TM3         99%         0.135       3.15      3.10       3.20      3.24       3.55          307.0        614.0

 H-Field Strength at 15 cm from the edges surrounding the EUT and 15cm from the top surface of the EUT
                                                                                          FCC H-
                                           Measured E-Field Strength Values (A/m)                    FCC H-
                                                                                           Field
             Charging Frequency                                                                        Field
  Test                                                                                   Strength
              Battery     Range        Test      Test       Test      Test       Test                Strength
Conditions                                                                                  50%
               Level      (MHz)      Position Position Position Position Position                     Limits
                                                                                           Limits
                                        A          B         C          D         E                   (A/m)
                                                                                           (A/m)
  TM1          1%           0.135     0.274     0.285      0.279      0.266         0.357     0.815        1.63

  TM2          50%          0.135     0.233     0.241      0.224      0.245         0.331     0.815        1.63

  TM3          99%          0.135     0.205     0.210      0.209      0.215         0.317     0.815        1.63

 H-Field Strength at 20cm from the top surface of the EUT
             Charging Frequency         Measured E-Field Strength      FCC H-Field             FCC H-Field
  Test
              Battery       Range              Values (A/m)            Strength 50%           Strength Limits
Conditions
               Level        (MHz)            Test Position E            Limits (A/m)              (A/m)
   TM1          1%           0.135               0.310                      0.815                  1.63

   TM2         50%           0.135               0.268                      0.815                  1.63

   TM3         99%           0.135               0.243                      0.815                  1.63


      Report No.: GTS20191028006-1-1-2                                                     Page 9 of 11


    3.5.2  For portable exposure
                      E-Field Strength at 0/5/10/15 cm from the edges surrounding the EUT
                                                         Measured E-Field Strength Values (V/m)             FCC E-
           Charging Measured Frequency                                                                       Field
  Test                                            Test     Test      Test      Test      Test      Test
            Battery    Distance     Range                                                                   Strength
Conditions                                      Position Position Position Position Position       Positi
             Level       (cm)        (MHz)                                                                   Limits
                                                   A         B         C         D         E       on F
                                                                                                             (V/m)
  TM7           1%         0          0.135      10.52     10.65     10.58     10.60     12.37     12.39     614.0
  TM8          50%         0          0.135      10.21     10.15     10.24     10.12     12.05     12.10     614.0
  TM9          99%         0          0.135      9.38      9.50      9.45      9.35      11.25     11.36     614.0
  TM7           1%         5          0.135      8.45      8.30      8.55      8.47      9.85       9.98     614.0
  TM8          50%         5          0.135      8.12      8.13      8.30      8.15      9.47       9.50     614.0
  TM9          99%         5          0.135      7.87      7.64      7.92      7.79      9.10       9.16     614.0
  TM7           1%         10         0.135      4.68      4.71      4.55      4.47      5.78       5.90     614.0
  TM8          50%         10         0.135      4.45      4.52      4.32      4.23      5.45       5.52     614.0
  TM9          99%         10         0.135      4.42      4.36      4.24      4.10      5.21       5.14     614.0
  TM7           1%         15         0.135      3.21      3.15      3.32      3.29      4.35       4.22     614.0
  TM8          50%         15         0.135      3.57      3.46      3.54      3.44      3.89       3.79     614.0
  TM9          99%         15         0.135      3.20      3.21      3.17      3.20      3.59       3.70     614.0

                           H-Field Strength at 0/5/10/15 cm from the edges surrounding the EUT
                                                          Measured H-Field Strength Values (A/m)            FCC H-
             Charging   Measured Frequency                                                                    Field
  Test                                             Test      Test      Test      Test      Test    Test
              Battery   Distance      Range                                                                 Strength
Conditions                                       Position Position Position Position Position      Positi
               Level      (cm)        (MHz)                                                                  Limits
                                                    A          B        C         D         E      on F
                                                                                                             (A/m)
  TM7           1%         0          0.135      0.885     0.876     0.881     0.866     1.142     1.138      1.63
  TM8          50%         0          0.135      0.855     0.832     0.842     0.834     1.087     1.055      1.63
  TM9          99%         0          0.135      0.814     0.788     0.804     0.793     0.975     0.765      1.63
  TM7           1%         5          0.135      0.587     0.574     0.590     0.562     0.788     0.754      1.63
  TM8          50%         5          0.135      0.535     0.529     0.541     0.515     0.736     0.719      1.63
  TM9          99%         5          0.135      0.505     0.487     0.510     0.479     0.701     0.698      1.63
  TM7           1%         10         0.135      0.366     0.380     0.374     0.385     0.474     0.468      1.63
  TM8          50%         10         0.135      0.325     0.336     0.330     0.340     0.425     0.417      1.63
  TM9          99%         10         0.135      0.289     0.305     0.291     0.311     0.389     0.378      1.63
  TM7           1%         15         0.135      0.274     0.268     0.277     0.284     0.366     0.357      1.63
  TM8          50%         15         0.135      0.225     0.215     0.229     0.235     0.315     0.305      1.63
  TM9          99%         15         0.135      0.201     0.198     0.205     0.217     0.298     0.287      1.63


 Report No.: GTS20191028006-1-1-2                                                         Page 10 of 11


3.6   Equipment Approval Considerations
The EUT does comply with KDB 680106 D01 as follow table.
Requirements of KDB 680106 D01                      Yes / No   Description
                                                               The device operate in the frequency range
Power transfer frequency is less than 1 MHz           Yes
                                                               110KHz~205KHz
Output power from each primary coil is less                    The maximum output power for each
                                                      Yes      primary coil is 10W.
than 15 watts
The transfer system includes only single
primary and secondary coils. This includes
charging systems that may have multiple                        The transfer system includes only one
                                                      Yes
primary coils and clients that are able to detect              primary coils.
and allow coupling only between individual
pairs of coils.
Client device is placed directly in contact with               Client device is placed directly in contact with
                                                      Yes
the transmitter.                                               the transmitter.
Mobile exposure conditions only (portable
                                                               Mixed mobile and portable exposure
exposure conditions are not covered by this           No
                                                               conditions
exclusion).
The aggregate H-field strengths at 15 cm
surrounding the device and 20 cm above the                     Not only just for mobile exposure condition,
top surface from all simultaneous transmitting        No       this sample used at mixed mobile and
coils are demonstrated to be less than 50% of                  portable exposure condition.
the MPE limit.


3.7   Conclusion
A minimum safety distance of 0 cm to the antenna is required when the device is charging a smart phone for
portable exposure and 20 cm to the antenna for mobile exposure. The detected emissions are below the
limitations according FCC KDB 680106 and confirmed by the FCC according to KDB Inquire.


Report No.: GTS20191028006-1-1-2                                                    Page 11 of 11



4 Test Setup Photos of the EUT




                      ********************** End of Report **********************



Document Created: 2019-11-04 13:31:49
Document Modified: 2019-11-04 13:31:49

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC