Test report-DCD

FCC ID: 2ARD3-LL127

Test Report

Download: PDF
FCCID_4501525

                        Shenzhen Global Test Service Co.,Ltd.
                        No.7-101 and 8A-104, Building 7 and 8, DCC Cultural and Creative Garden, No.98, Pingxin North Road,
                        Shangmugu Community, Pinghu Street, Longgang District, Shenzhen, Guangdong




                           FCC PART 15 SUBPART C TEST REPORT

Report Reference No. ..................... :               GTS20191028006-1-1
FCC ID. ........................................... :      2ARD3-LL127
              Compiled by
( position+printed name+signature).. :                     File administrators Jimmy Wang


            Supervised by
( position+printed name+signature).. :                     Test Engineer Aaron Tan

              Approved by
( position+printed name+signature).. :                     Manager Jason Hu


Date of issue..................................... :       Oct. 23, 2019
Representative Laboratory Name .:                          Shenzhen Global Test Service Co., Ltd.

                                                           No.7-101 and 8A-104, Building 7 and 8, DCC Cultural and Creative
Address ............................................ :     Garden, No.98, Pingxin North Road, Shangmugu Community,
                                                           Pinghu Street, Longgang District, Shenzhen, Guangdong
Applicant’s name ............................ :            LEXON

Address ............................................ :     91 avenue Jean-Baptiste Clement 92100 Boulogne FRANCE
Test specification ...........................:

                                                           FCC Rules and Regulations Part 15 Subpart C (Section 15.209),
Standard ........................................... :
                                                           ANSI C63.10: 2013
TRF Originator .................................. :        Shenzhen Global Test Service Co.,Ltd.

Master TRF ....................................... :       Dated 2014-12

Shenzhen Global Test Service Co.,Ltd. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the
Shenzhen Global Test Service Co.,Ltd. is acknowledged as copyright owner and source of the material.
Shenzhen Global Test Service Co.,Ltd. takes no responsibility for and will not assume liability for damages
resulting from the reader's interpretation of the reproduced material due to its placement and context.
Test item description .....................:               BALI WIRELESS CHARGING PAD WITH BATTERY
Trade Mark ....................................... :       LEXON
Manufacturer .................................... :        LEXON
Model/Type reference....................... :              LL127
Listed Models .................................. :         N/A
Modulation Type ............................... :          ASK
Operation Frequency ........................ :             From 110KHz~205KHz

Rating ............................................... :   DC 3.7V from battery charged by DC 5V
Result................................................ :   PASS


Report No.: GTS20191028006-1-1                                                                               Page 2 of 22

                                   TEST REPORT
                                                                                           Oct. 23, 2019
 Test Report No. :                 GTS20191028006-1-1               ____________________________________________________________________________________


                                                                                           Date of issue


   Equipment under Test      :     BALI WIRELESS CHARGING PAD WITH BATTERY


   Model /Type               :     LL127


   Listed Models             :     N/A


   Applicant                 :     LEXON


   Address                   :     91 avenue Jean-Baptiste Clement 92100 Boulogne FRANCE


   Manufacturer              :     LEXON


   Address                   :     91 avenue Jean-Baptiste Clement 92100 Boulogne FRANCE




                   Test Result:                                         PASS


   The test report merely corresponds to the test sample.
   It is not permitted to copy extracts of these test result without the written permission of the test
   laboratory.


    Report No.: GTS20191028006-1-1                                             Page 3 of 22



                                            Contents

1         TEST STANDARDS .................................................................. 4

2         SUMMARY ............................................................................. 5

2.1       General Remarks                                                                     5
2.2       Product Description                                                                 5
2.3       Equipment under Test                                                                5
2.4       Modifications                                                                       5

3         TEST ENVIRONMENT............................................................... 6

3.1       Address of the test laboratory                                                      6
3.2       Test Facility                                                                       6
3.3       Environmental conditions                                                            6
3.4       Summary of measurement results                                                      7
3.5       Statement of the measurement uncertainty                                            7
3.6       Equipments Used during the Test                                                     7

4         TEST CONDITIONS AND RESULTS ............................................. 9

4.1       AC Power Conducted Emission                                                         9
4.2       Radiated Emission                                                                   12
4.3       Occupied Bandwidth                                                                  16
4.4       Antenna Requirement                                                                 17

5         TEST SET-UP PHOTOS OF THE EUT ......................................... 18

6         PHOTOS OF THE EUT ............................................................. 19


 Report No.: GTS20191028006-1-1                                                       Page 4 of 22



1 TEST STANDARDS
The tests were performed according to following standards:

FCC Rules and Regulations Part 15 Subpart C (Section 15.207): Conducted limits.
FCC Rules and Regulations Part 15 Subpart C (Section 15.209): Radiated emission limits; general
requirements.
ANSI C63.10: 2013: American National Standard for Testing Unlicensed Wireless Devices


 Report No.: GTS20191028006-1-1                                                            Page 5 of 22

2 SUMMARY

2.1   General Remarks
Date of receipt of test sample         :       Oct. 12, 2019


Testing commenced on                   :       Oct. 13, 2019


Testing concluded on                   :       Oct. 22, 2019

2.2   Product Description
Product Name:                    BALI WIRELESS CHARGING PAD WITH BATTERY
Model/Type reference:            LL127
Power supply:                    DC 3.7V from battery charged by DC 5V
                                 Mode:EP-TA20CBC
Adapter(Auxiliary        test
                                 Input:AC100-240V-50/60Hz,0.5A
Provided by the laborator)
                                 Output:DC 5V,2A
Wireless Charger
Antenna Type                     Coil Antenna
Antenna Gain                     1.0dBi
Operation frequency              110KHz~205KHz
Modulation Type                  ASK
Rated Output power               10W


2.3   Equipment under Test
Power supply system utilised
Power supply voltage                       :   ○ 230V / 50 Hz                  ○ 120V / 60Hz
                                               ○ 12 V DC                       ○ 24 V DC
                                               ● Other (specified in blank below)

                                    DC 3.7V from battery charged by DC 5V

Description of the test mode

 Operation Frequency each of channel
 Channel       Frequency
 1             135KHz

Operating Mode
The mode is used: Transmitting mode


2.4   Modifications
No modifications were implemented to meet testing criteria.


 Report No.: GTS20191028006-1-1                                                             Page 6 of 22



3 TEST ENVIRONMENT

3.1   Address of the test laboratory
Shenzhen Global Test Service Co.,Ltd.
No.7-101 and 8A-104, Building 7 and 8, DCC Cultural and Creative Garden, No.98, Pingxin North Road,
Shangmugu Community, Pinghu Street, Longgang District, Shenzhen, Guangdong

The 3m-Semi anechoic test site fulfils CISPR 16-1-4 according to ANSI C63.4:2014 and CISPR 16-1-4:2010
SVSWR requirement for radiated emission above 1GHz.


3.2   Test Facility
The test facility is recognized, certified, or accredited by the following organizations:

FCC-Registration No.: 165725
Shenzhen Global Test Service Co.,Ltd EMC Laboratory has been registered and fully described in a report
filed with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is maintained
in our files.

A2LA-Lab Cert. No.: 4758.01

Shenzhen Global Test Service Co.,Ltd. EMC Laboratory has been accredited by A2LA for
technical competence in the field of electrical testing, and proved to be in compliance with ISO/IEC 17025:
2005 General Requirements for the Competence of Testing and Calibration Laboratories and any additional
program requirements in the identified field of testing.


CNAS-Lab Code: L8169
Shenzhen Global Test Service Co.,Ltd. has been assessed and proved to be in compliance with CNAS-
CL01 Accreditation Criteria for Testing and Calibration Laboratories (identical to ISO/IEC 17025: 2005
General Requirements) for the Competence of Testing and Calibration Laboratories. Date of Registration:
Dec. 11, 2015. Valid time is until Dec. 10, 2024.



3.3   Environmental conditions
During the measurement the environmental conditions were within the listed ranges:

  Temperature:                                  15-35 °C

  Humidity:                                      30-60 %

  Atmospheric pressure:                      950-1050mbar


 Report No.: GTS20191028006-1-1                                                          Page 7 of 22

3.4    Summary of measurement results
 DESCRIPTION OF TEST                                                   RESULT
 CONDUCTED EMISSIONS TEST                                             COMPLIANT
 RADIATED EMISSION TEST                                               COMPLIANT
 OCCUPIED BANDWIDTH MEASUREMENT                                       COMPLIANT
 ANTENNA REQUIREMENT                                                  COMPLIANT

3.5    Statement of the measurement uncertainty
The data and results referenced in this document are true and accurate. The reader is cautioned that there
may be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was
calculated for all measurements listed in this test report acc. to CISPR 16 - 4 „Specification for radio
disturbance and immunity measuring apparatus and methods – Part 4: Uncertainty in EMC
Measurements“ and is documented in the Shenzhen Global Test Service Co.,Ltd quality system acc. to DIN
EN ISO/IEC 17025. Furthermore, component and process variability of devices similar to that tested may
result in additional deviation. The manufacturer has the sole responsibility of continued compliance of the
device.

Hereafter the best measurement capability for Shenzhen GTS laboratory is reported:
                                                                      Measurement
                       Test                        Range                               Notes
                                                                       Uncertainty
            Radiated Emission                  30~1000MHz                4.10 dB         (1)
            Radiated Emission                     1~18GHz                4.32 dB         (1)
            Radiated Emission                    18-40GHz                5.54 dB         (1)
            Conducted Disturbance               0.15~30MHz               3.12 dB         (1)
          (1) This uncertainty represents an expanded uncertainty expressed at approximately the 95%
              confidence level using a coverage factor of k=2.


3.6    Equipments Used during the Test
                                                                                  Calibration    Calibration
  Test Equipment         Manufacturer          Model No.          Serial No.
                                                                                    Date         Due Date
        LISN                 R&S                ENV216          3560.6550.08      2019/09/20     2020/09/19
        LISN                 R&S               ESH2-Z5           893606/008       2019/09/20     2020/09/19
   Bilog Antenna         Schwarzbeck           VULB9163              976          2019/09/20     2020/09/19
 EMI Test Receiver           R&S                 ESCI7             101102         2019/09/20     2020/09/19
Spectrum Analyzer           Agilent             N9020A          MY48010425        2019/09/20     2020/09/19
Spectrum Analyzer            R&S                 FSP40             100019         2019/09/20     2020/09/19
                                             Controller EM
      Controller        EM Electronics                               N/A             N/A             N/A
                                                1000
   Horn Antenna          Schwarzbeck         BBHA 9120D             01622         2019/09/20     2020/09/19
      Active Loop       SCHWARZBEC
                                               FMZB1519           1519-037        2019/09/20     2020/09/19
       Antenna              K
  Broadband Horn        SCHWARZBEC
                                              BBHA 9170              971          2019/09/20     2020/09/19
     Antenna                K
      Amplifier          Schwarzbeck           BBV 9743             #202          2019/09/20     2020/09/19
      Amplifier              EMCI            EMC051845B            980355         2019/09/20     2020/09/19
Temperature/Humidi
                           Gangxing            CTH-608                02          2019/09/20     2020/09/19
    ty Meter
                                                9SH10-
  High-Pass Filter            K&L            2700/X12750-         KL142031        2019/09/20     2020/09/19
                                                 O/O

  High-Pass Filter            K&L               41H10-            KL142032        2019/09/20     2020/09/19
                                             1375/U12750-


 Report No.: GTS20191028006-1-1                                     Page 8 of 22

                                        O/O
  RF Cable(below       HUBER+SUHNE
                                       RG214       RE01       2019/09/20   2020/09/19
      1GHz)                 R
  RF Cable(above       HUBER+SUHNE
                                       RG214       RE02       2019/09/20   2020/09/19
      1GHz)                 R
  Data acquisition
                            Agilent    U2531A    TW53323507   2019/09/20   2020/09/19
       card
   Power Sensor             Agilent    U2021XA   MY5365004    2019/09/20   2020/09/19
 EMI Test Software           R&S        ES-K1      V1.7.1     2019/09/20   2020/09/19
 EMI Test Software       JS Tonscend   JS32-RE     2.0.1.5    2019/09/20   2020/09/19
 EMI Test Software           Audix       E3        2..1.1     2019/09/20   2020/09/19
Note: The Cal.Interval was one year.


 Report No.: GTS20191028006-1-1                                                            Page 9 of 22



4 TEST CONDITIONS AND RESULTS

4.1     AC Power Conducted Emission

TEST CONFIGURATION




TEST PROCEDURE

      1, The equipment was set up as per the test configuration to simulate typical actual usage per the user’s
         manual. The EUT is a tabletop system, a wooden table with a height of 0.8 meters is used and is
         placed on the ground plane as per ANSI C63.10.
      2, Support equipment, if needed, was placed as per ANSI C63.10.
      3, All I/O cables were positioned to simulate typical actual usage as per ANSI C63.10.
      4, If a EUT received DC power from the USB Port of Notebook PC, the PC’s adapter received power
         through a Line Impedance Stabilization Network (LISN) which supplied power source and was
         grounded to the ground plane.
      5, All support equipments received AC power from a second LISN, if any.
      6, The EUT test program was started. Emissions were measured on each current carrying line of the EUT
         using a spectrum Analyzer / Receiver connected to the LISN powering the EUT. The LISN has two
         monitoring points: Line 1 (Hot Side) and Line 2 (Neutral Side). Two scans were taken: one with Line 1
         connected to Analyzer / Receiver and Line 2 connected to a 50 ohm load; the second scan had Line 1
         connected to a 50 ohm load and Line 2 connected to the Analyzer / Receiver.
      7, Analyzer / Receiver scanned from 150 KHz to 30MHz for emissions in each of the test modes.

AC Power Conducted Emission Limit

For intentional device, according to § 15.207(a) AC Power Conducted Emission Limits is as following:
                                                                     Limit (dBuV)
          Frequency range (MHz)
                                                       Quasi-peak                       Average
                  0.15-0.5                              66 to 56*                       56 to 46*
                    0.5-5                                  56                               46
                    5-30                                   60                               50
* Decreases with the logarithm of the frequency.


 Report No.: GTS20191028006-1-1                                                      Page 10 of 22

TEST RESULTS

1. Both 120 VAC, 50/60 Hz and 240 VAC, 50/60 Hz power supply have been tested, only the worst result of
   120 VAC, 60 Hz was reported as below:.
                          DC 5V from Adapter
    Power supply:                                        Polarization                     L
                            AC 120V/60Hz


Report No.: GTS20191028006-1-1                            Page 11 of 22



                      DC 5V from Adapter
  Power supply:                            Polarization        N
                        AC 120V/60Hz


 Report No.: GTS20191028006-1-1                                                             Page 12 of 22


4.2     Radiated Emission
Limit
For intentional device, according to § 15.209(a), the general requirement of field strength of radiated emission
out of authorized band shall not exceed the following table at a 3 meters measurement distance.
In addition, radiated emissions which fall in the restricted bands, as defined in §15.205(a), must also comply
with the radiated emission limits specified in §15.209(a)
                                          Radiated emission limits
  Frequency (MHz)          Distance (Meters)             Radiated (dBμV/m)                    Radiated (μV/m)
     0.009-0.49                    3              20log(2400/F(KHz))+40log(300/3)              2400/F(KHz)
     0.49-1.705                    3              20log(24000/F(KHz))+ 40log(30/3)             24000/F(KHz)
      1.705-30                     3                   20log(30)+ 40log(30/3)                        30
       30-88                       3                             40.0                               100
       88-216                      3                             43.5                               150
      216-960                      3                             46.0                               200
     Above 960                     3                             54.0                               500


TEST CONFIGURATION
                            1.    Radiated Emission Test Set-Up, Frequency Below 30MHz




                           2.    Radiated Emission Test Set-Up, Frequency below 1000MHz


 Report No.: GTS20191028006-1-1                                                            Page 13 of 22

Test Procedure
1.    Below 1GHz measurement the EUT is placed on a turntable which is 0.8m above ground plane.
2.    Maximum procedure was performed by raising the receiving antenna from 1m to 4m and rotating the turn
      table from 0℃ to 360℃ to acquire the highest emissions from EUT
3.    And also, each emission was to be maximized by changing the polarization of receiving antenna both
      horizontal and vertical.
4.    Repeat above procedures until all frequency measurements have been completed.
5.    Radiated emission test frequency band from 9KHz to 1000MHz.
6.    The distance between test antenna and EUT as following table states:
           Test Frequency range         Test Antenna Type               Test Distance
           9KHz-30MHz                   Active Loop Antenna             3
           30MHz-1GHz                   Bilog Antenna                   3
7.    Setting test receiver/spectrum as following table states:
           Test Frequency range               Test Receiver/Spectrum Setting             Detector
               9KHz-150KHz             RBW=200Hz/VBW=3KHz,Sweep time=Auto                  QP
              150KHz-30MHz            RBW=9KHz/VBW=100KHz,Sweep time=Auto                  QP
                30MHz-1GHz           RBW=120KHz/VBW=1000KHz,Sweep time=Auto                QP


TEST RESULTS


For 9 KHz-30MHz
                                 WORST-CASE RADIATED EMISSION BELOW 30 MHz
                                          Antenna   Cable     Emission                                     Detector
 Frequency        Reading         Polar                                     Limits at 3m        Margin
                                           Factor   Loss        Levels                                      Mode
      (MHz)      (dBμV/m)         Loop     (dB/m)   (dB)      (dBμV/m)        (dBμV/m)           (dB)
     0.135(F)      56.61          Loop      23.64    0.01       80.26          103.91            23.65       PK
     0.135(F)      48.04          Loop     23.64     0.01       71.69           83.91            12.22       AV
      0.110        45.96          Loop     23.55     0.01       69.52          106.78            37.26       PK
      0.110        36.77          Loop     23.55     0.01       60.33           86.78            26.45       AV
      0.665        33.85          Loop     25.07     -0.17      58.75           71.15            12.40       QP
      1.625        23.46          Loop     27.12     -0.25      50.33           63.39            13.06       QP
      8.205        30.18          Loop     23.91     -0.24      53.85           69.54            15.69       QP
       --            --            --       --        --         --              --                          --
Remark:
1. Data of measurement within this frequency range shown “-- in the table above means the reading of
   emissions are attenuated more than 20dB below the permissible limits and not recorded.
2. The test limit distance is 3m limit.
3. PK means Peak Value, QP means Quasi Peak Value, AV means Average Value.
4. F means Fundamental Frequency.
5. Emission level (dBuV/m) =Reading + Antenna Factor + Cable Loss.
6. Margin value = Limit value- Emission level.


Report No.: GTS20191028006-1-1                Page 14 of 22


For 30MHz-1GHz
                                 Horizontal


Report No.: GTS20191028006-1-1              Page 15 of 22


                                 Vertical


 Report No.: GTS20191028006-1-1                                                              Page 16 of 22


4.3     Occupied Bandwidth

TEST CONFIGURATION


                                                               SPECTRUM
                      EUT
                                                               ANALYZER


TEST PROCEDURE

Intentional radiators operating under the alternative provisions to the general emission limits, as contained in
§§15.217 through 15.257 and in subpart E of this part, must be designed to ensure that 20dB bandwidth of
the emission, or whatever bandwidth may otherwise be specified in the specific rule section under which the
equip compliance with the 20dB attenuation specification may base on measurement at the intentional
radiator’s antenna output terminal unless the intentional radiator uses a permanently attached antenna, in
which case compliance shall be.deomonstrated by measuring the radiated emissions.

LIMIT

The 20dB bandwidth shall be less than 80% of the permitted frequency band.

TEST RESULTS

                                               20dB Bandwidth             99% OBW
        Mode            Freq (KHz)                                                               Conclusion
                                                   (KHz)                    (KHz)

      Tx Mode               135                     4.168                    3.777                  PASS


 Report No.: GTS20191028006-1-1                                                            Page 17 of 22


4.4   Antenna Requirement

Standard Applicable

Standard Applicable

For intentional device, according to FCC 47 CFR Section 15.203, an intentional radiator shall be designed to
ensure that no antenna other than that furnished by the responsible party shall be used with the device.

And according to FCC 47 CFR Section 15.247 (c), if transmitting antennas of directional gain greater than
6dBi are used, the power shall be reduced by the amount in dB that the directional gain of the antenna
exceeds 6dBi.

Antenna Information

The antenna used in this product is a Coil Antenna, The directional gains of antenna used for transmitting is
1dBi.


Report No.: GTS20191028006-1-1    Page 18 of 22

5 Test Set-up Photos of the EUT


Report No.: GTS20191028006-1-1                            Page 19 of 22

6 PHOTOS OF THE EUT
                                 External Photos of EUT


Report No.: GTS20191028006-1-1   Page 20 of 22


Report No.: GTS20191028006-1-1   Page 21 of 22


Report No.: GTS20191028006-1-1                                                     Page 22 of 22

                                     Internal Photos of EUT




                   antenna




                     ********************** End of Report **********************



Document Created: 2019-11-04 21:24:41
Document Modified: 2019-11-04 21:24:41

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC