test report

FCC ID: 2ARD3-LH059

Test Report

Download: PDF
FCCID_4372081

                                                                                 Report Number: SZ1905FE11
                                                                                                    Rev. 01




                                      EMC Test Report


Applicant                : LEXON

Product Type             : OBLIO

Trade Name               : LEXON

Model Number             : LH59

FCC ID                   : 2ARD3-LH059

EUT Rated Voltage        : DC 9 V, 2 A

Test Voltage             : 120 Vac / 60 Hz

Test Specification       : FCC 47 CFR PART 18 Subpart C
                           MP-5:1986

Receive Date             : Apr. 12, 2019

Test Period              : Apr. 26 ~ May 14, 2019

Issue Date               : Jul. 24, 2019

                                                 Issue by

A Test Lab Techno Corp.
101-104, 1F, A building, Safflower ridge industrial area,
Taoyuan street, Nanshan district, Shenzhen
Tel:+86-755-23987770 / Fax:+86-755-26637771
American Association for Laboratory Accreditation number: 3464.02
 Note: This report shall not be reproduced except in full, without the written approval of A Test Lab Techno
 Corp. This document may be altered or revised by A Test Lab Techno Corp. personnel only, and shall be
 noted in the revision section of the document. The client should not use it to claim product endorsement by
 TAF, or any government agencies. The test results in the report only apply to the tested sample.


  Approved By             :                              Reviewed By               :

  (Manager)                       (Hai. Wang)            (Testing Engineer)                 (Simon. Hu)




                                               Page 1 of 16


                                                               Report Number: SZ1905FE11
                                                                                  Rev. 01




                                   Revision History
Rev.    Issue Date                                 Revisions
00     May 28, 2019    Initial Issue.
01     Jul. 24, 2019   Page 1 and 5 added FCC ID.




                                    Page 2 of 16


                                                                                                  Report Number: SZ1905FE11
                                                                                                                     Rev. 01




                                              TABLE OF CONTENTS
1 General Information ......................................................................................................... 4
2 EUT Description................................................................................................................ 5
3 Test Methodology ............................................................................................................. 5
  3.1.   Decision of Test Mode ............................................................................................ 5
  3.2.   EUT Exercise Software .......................................................................................... 5
  3.3.   Configuration of Test System Details ..................................................................... 6
  3.4.   Test Instruments ..................................................................................................... 7
4 Emission Test ................................................................................................................... 8
  4.1.   Conducted Emission .............................................................................................. 8
  4.2.   Radiated Emission ................................................................................................. 9
5 Test Result ...................................................................................................................... 11
  5.1.   Conducted Emission ............................................................................................ 11
  5.2.   Radiated Emission ............................................................................................... 14




                                                         Page 3 of 16


                                                                                              Report Number: SZ1905FE11
                                                                                                                 Rev. 01



1     General Information
1.1   Summary of Test Result

                                                               Emission

                      Standard                                Item                      Result                Remark


        FCC 47 CFR PART 18
                                                 Conducted Emission                     PASS           Consumer Equipment
        §18.307 (b)


        FCC 47 CFR PART 18
                                                 Radiated Emission                      PASS           Consumer Equipment
        §18.305 (b)

      The test results of this report relate only to the tested sample(s) identified in this report. Manufacturer or whom it
      may concern should recognize the pass or fail of the test result.


1.2   Testing Location

      Site Name:          A Test Lab Techno Corp.
      Site Address:       101-104, 1F, A building, Safflower ridge industrial area,
                          Taoyuan street, Nanshan district, Shenzhen
      Tel:                +86-755-23987770
      Fax:                +86-755-26637771


1.3   Measurement Uncertainty

                                Test Item                                     Frequency Range                Uncertainty (dB)

       Conducted Emission         AC Power Port                              150 kHz ~ 30 MHz                       2.8



              Test Item                      Test Site                        Frequency Range                Uncertainty (dB)

       Radiated Emission         RE-026                                        9 kHz ~ 30 MHz                       6.3
       The Vertical and Horizontal measurement uncertainty of 30 MHz to 1GHz is evaluated and choose which polarity is
       worst value.



1.4   Test Site Environment

              Test Item                        Items                       Required (IEC 60068-1)                 Actual
                                         Temperature (C)                             15-35                         26
        Conducted Emission                Humidity (%RH)                              25-75                         60
                                    Barometric pressure (mbar)                    860-1060                         990
                                         Temperature (C)                             15-35                         26
         Radiated Emission                Humidity (%RH)                              25-75                         60
                                    Barometric pressure (mbar)                    860-1060                         990




                                                     Page 4 of 16


                                                                                      Report Number: SZ1905FE11
                                                                                                         Rev. 01



2        EUT Description
                                   LEXON
          Applicant
                                   91 avenue Jean-Baptiste Clément - 92100 Boulogne - FRANCE
                                   LEXON
          Manufacturer
                                   91 avenue Jean-Baptiste Clément - 92100 Boulogne - FRANCE

          Product Type             OBLIO

          Trade Name               LEXON

          Model Number             LH59

          FCC ID                   2ARD3-LH059

          I/O Ports                 Refer to User Manual

          Highest Operating
                                   210 kHz
          Frequency




3        Test Methodology
3.1.     Decision of Test Mode
3.1.1.   The following test mode(s) were scanned during the preliminary test:

                                                            Pre-Test Mode
          Mode 1: Normal operation mode(AC 120 V / 60 Hz)


3.1.2.   After the preliminary scan, the following test mode was found to produce the highest emission
         level.

          Final Test Mode
                           Conducted Emission                     Mode 1
          Emission
                           Radiated Emission                      Mode 1
         Then, the above highest emission mode of the configuration of the EUT and cable was chosen for all final test

         items.



3.2.     EUT Exercise Software

           1.     Setup the EUT and simulators as shown on 3.3.

           2.     Turn on the power of all the equipment.

           3.     Make the i-Pod charging with EUT.

           4.     Start to test get the worst reading




                                                        Page 5 of 16


                                                                                           Report Number: SZ1905FE11
                                                                                                              Rev. 01




3.3.   Configuration of Test System Details

                                                           Mode 1


                          AC Input


                                 AC                                EUT
                               Adapter          A

                                                                    (2)
                                                          Wireless charge receiver

                                                                     (1)
                                                                   i-Pod




                     Signal Cable Type                                      Signal Cable Description
        A     USB Type-C Cable                               Non-Shielded, 1.2 m


                                                      Devices Description

              Product                Manufacturer      Model Number          Serial Number             Power Cord

       (1)        i-Pod                 Apple             A1574                      N/A                  N/A
             Wireless charge
       (2)                              PZOZ             JDHZ21                      N/A                  N/A
                 receiver




                                                    Page 6 of 16


                                                                                            Report Number: SZ1905FE11
                                                                                                               Rev. 01




3.4.   Test Instruments

       Test Period : Apr. 26, 2019

                                                    Conducted Emission test site

              Equipment               Manufacturer         Model Number      Serial Number        Cal. Date   Remark

            Test Receiver                R&S                    ESR3               101923        09/14/2018    1 year

                 LISN                    R&S                   ENV216              101942        09/18/2018    1 year

                 LISN                    R&S                   ENV216              101943        09/18/2018    1 year

                  RF                     EMCI               EMCCFD400              433LFC        09/18/2018    1 year

               Test Site                  ATL                    CE                 CE             N.C.R.       -----



       Test Period : May 14, 2019

                                               Radiated Emission - 3 Meter Chamber

             Equipment               Manufacturer          Model Number      Serial Number        Cal. Date   Remark
            Preamplifier
                                        EMCI                 EMC001330             980300        09/18/2018    1 year
          (10 kHz~3 GHz)
             Preamplifier
                                        EMCI               EMC012645SE             980318        09/18/2018    1 year
        (0.1 GHz~26.5 GHz)
            Preamplifier
                                        EMCI                EMC2654045             980028        09/18/2018    1 year
        (26.5 GHz~40 GHz)
           Bilog Antenna
                                     Schwarzbeck             VULB 9168              672          11/21/2018    1 year
         (30 MHz~1.4 GHz)
            Horn Antenna
                                         ETS                    3117           00204949          11/16/2018    1 year
          (1 GHz~18 GHz)
             Receiver
                                       Keysight                N9038A        MY51210179          09/18/2018    1 year
         (3 Hz~26.5 GHz)
        Spectrum Analyzer
                                       Keysight                N9030A        MY55410268          09/18/2018    1 year
         (3 Hz~43 GHz)
              Cable
                                        EMCI                     N/A           1066LFC           09/18/2018    1 year
         (30 MHz~1 GHz)
               Cable
                                        EMCI                     N/A               160719        09/18/2018    1 year
          (1 GHz~18 GHz)
               Cable
                                        EMCI                     N/A               160324        09/18/2018    1 year
          (1 GHz~18 GHz)
               Cable
                                        EMCI                     N/A               160322        09/18/2018    1 year
          (1 GHz~18 GHz)
           Loop Antenna                 EMCI                   LPA600               272          02/21/2019    1 year

              Test Site                OuHeng                 MFAC3M               RE-026        02/14/2019    1 year


       Note: N.C.R. = No Calibration Request.




                                                     Page 7 of 16


                                                                                            Report Number: SZ1905FE11
                                                                                                               Rev. 01



4      Emission Test
4.1.   Conducted Emission

        Test Setup




        Test Procedure
       a)   The EUT was placed 0.8 meters form the horizontal ground plane with EUT being connected to the power
            mains though a line impedance stabilization network (LISN). All other support equipments powered from
            additional LISN(s). The LISN provide 50 ohm/50uH of coupling impedance for the measuring instrument.
       b)   Interconnecting cables that hang closer than 40cm to the ground plane shall be folded back and forth in the
            center forming a bundle 30 to 40cm long.
       c)   I/O cables that are not connected to a peripheral shall be bundled in the center. The end of the cable may be
            terminated. If required, using the correct terminating impedance. The overall length shall not exceed 1m.
       d)   LISN at least 80cm from nearest part of EUT chassis.
       e)   For the actual test configuration, please refer to the related item “Configuration of Test System Details”
            (section 3.3).




                                                     Page 8 of 16


                                          Report Number: SZ1905FE11
                                                             Rev. 01




4.2.   Radiated Emission

        Setup
       9 kHz ~ 30 MHz




       30 MHz ~ 1 GHz




                           Page 9 of 16


                                                                                  Report Number: SZ1905FE11
                                                                                                     Rev. 01




 Test Procedure
a)   The measuring distance of at 3 m shall be used for measurement at frequency above 30 MHz. For
     frequencies above 30 MHz, any suitable measuring distance may be used.
b)   The EUT was placed on the top of a rotating table 0.8 m above the ground at 3m open area test site. The
     table was rotated 360 degrees to determine the position of the highest radiation.
c)   The height of the equipment or the substitution antenna shall be 0.8m; the height of the test antenna shall
     vary between 1 m to 4 m. Both horizontal and vertical polarizations of the antenna are set to make the
     measurement.
d)   The initial step in collecting radiated emission data is a spectrum analyzer peak detector mode pre-scanning
     the measurement frequency range. Significant peaks are marked and then Quasi Peak detector mode
     re-measured.
e)   If the Peak mode measured     value compliance with and lower than Quasi Peak mode limit, the EUT shall be
     deemed to meet QP limits and then no additional QP mode measurement performed.
f)   In case the emission is lower than 30MHz, loop antenna has be used for measurement and the recorded
     data should be QP measured by receiver. High – low scan is not required in this case.
g)   In the frequency range of 9kHz – 30MHz, magnetic field measurements may be performed. The method is
     applicable for radiated radio noise from all units, cables, power coeds and interconnect cabling or wring. A
     calibrated loop antenna as specified in ANSI C63.4 (4.5.2) shall be positioned with its plane vertical at the
     specified distance from the EUT and rotated about its vertical axis for maximum response at each azimuth
     about the EUT. For certain application, the loop antenna may also need to be positioned horizontally at the
     specified distance from the EUT. The center of the loop shall be 1 m above the round.
h)   For field strength measurements:
      Highest frequency generated or used in the device or
                                                                 Upper frequency of measurement range (MHz)
          on which the device operates or tunes (MHz)
                          Below 1.705                                                    30
                            1.705 - 30                                                 400
                             30 - 500                          Tenth harmonic or 1000 MHz, whichever is higher.
                           500 - 1000                                            Tenth harmonic
                           Above 1000                            Tenth harmonic or highest detectable emission




                                           Page 10 of 16


                                                                                        Report Number: SZ1905FE11
                                                                                                           Rev. 01



5      Test Result
5.1.   Conducted Emission

        Limit
       Power Line

                                                     Quasi-peak                                  Average
              Frequency (MHz)
                                                      (dBuV)                                     (dBuV)

                    0.15 - 0.5                         66-56 *                                   56-46 *

                    0.50 - 5.0                          56.00                                     46.00

                    5.0 - 30.0                          60.00                                     50.00

       Note: (1) The Equipment is for 18.307(b) other part 18 consumer devices.
             (2) The tighter limit applies at the band edges.
             (3) The limit of “*” marked band means the limitation decreases linearly with the logarithm of the frequency
                 in the range.




                                                  Page 11 of 16


                                                                                     Report Number: SZ1905FE11
                                                                                                        Rev. 01




 Test Result
 Standard:             FCC Part 18 §18.307(b)                        Line:                    L1
 Test item:            Conducted Emission                            Power:                   AC 120 V/60 Hz
 Mode:                 Mode 1                                        Temp.(℃)/Hum.(%RH):      26(℃)/60 %RH
 Description:




No. Frequency     QP        AVG      Correction     QP       AVG         QP      AVG       QP       AVG      Remark
                reading    reading     factor      result   result      limit    limit   margin    margin
      (MHz)     (dBuV)     (dBuV)        (dB)     (dBuV)    (dBuV)     (dBuV)   (dBuV)     (dB)     (dB)
 1    3.1100     10.80      1.43         9.79      20.59    11.22      56.00    46.00    -35.41    -34.78      Pass

 2    3.3940     24.25     18.62         9.80      34.05    28.42      56.00    46.00    -21.95    -17.58      Pass

 3    3.6700     24.54     20.09         9.82      34.36    29.91      56.00    46.00    -21.64    -16.09      Pass

 4    3.9500     22.61     15.43         9.83      32.44    25.26      56.00    46.00    -23.56    -20.74      Pass

 5    4.5140     23.38     17.71         9.86      33.24    27.57      56.00    46.00    -22.76    -18.43      Pass

 6    4.8020     25.51     20.62         9.87      35.38    30.49      56.00    46.00    -20.62    -15.51      Pass

Note: 1. Result (dBuV) = Correction factor (dB) + Reading(dBuV).
         Example: 20.59 = 9.79 + 10.80
      2. Correction factor (dB) = Cable loss (dB) + L.I.S.N. factor (dB).




                                                Page 12 of 16


                                                                                      Report Number: SZ1905FE11
                                                                                                         Rev. 01




 Standard:              FCC Part 18 §18.307(b)                        Line:                    N
 Test item:             Conducted Emission                            Power:                   AC 120 V/60 Hz
 Mode:                  Mode 1                                        Temp.(℃)/Hum.(%RH):      26(℃)/60 %RH
 Description:




No. Frequency     QP         AVG      Correction     QP       AVG         QP      AVG       QP      AVG       Remark
                reading     reading     factor      result   result      limit    limit   margin   margin
      (MHz)     (dBuV)      (dBuV)       (dB)      (dBuV)    (dBuV)     (dBuV)   (dBuV)     (dB)    (dB)
 1    2.8580     20.79      16.20        9.88       30.67    26.08      56.00    46.00    -25.33   -19.92       Pass

 2    3.7060     5.94        0.57        9.90       15.84    10.47      56.00    46.00    -40.16   -35.53       Pass

 3    4.0020     12.12       5.48        9.91       22.03    15.39      56.00    46.00    -33.97   -30.61       Pass

 4    4.2780     5.81        0.49        9.92       15.73    10.41      56.00    46.00    -40.27   -35.59       Pass

 5    4.5660     6.23        1.04        9.94       16.17    10.98      56.00    46.00    -39.83   -35.02       Pass

 6    4.8460     6.02        0.75        9.95       15.97    10.70      56.00    46.00    -40.03   -35.30       Pass

Note: 1. Result (dBuV) = Correction factor (dB) + Reading(dBuV).
         Example: 30.67 = 9.88 + 20.79
      2. Correction factor (dB) = Cable loss (dB) + L.I.S.N. factor (dB).




                                                 Page 13 of 16


                                                                                             Report Number: SZ1905FE11
                                                                                                                Rev. 01




5.2.   Radiated Emission

        Limit
       9 k~30 MHz
          Operating Frequency             Measurement Distance at 300 meters             Measurement Distance at 3 meters
                 (MHz)                       (uV/m)                   (dBuV/m)                         (dBuV/m)
                Any ISM                        25                       27.96                           107.96
              Any non-ISM                      15                       23.52                           103.52
       Note:
       (1) The Equipment is for 18.305(b). Any type unless otherwise specified (miscellaneous) operating frequency in any
           non-ISN frequency.
       (2) Limitation expressed in dBuV/m is calculated by 20log emission level (uV/m).
       (3) Distance extrapolation factor = 40log (specific distance / test distance) (dB), Limit line = specific limits (dBuV/m)
           + distance extrapolation factor.


       Above 30 MHz
          Operating Frequency             Measurement Distance at 300 meters             Measurement Distance at 3 meters
                 (MHz)                       (uV/m)                   (dBuV/m)                         (dBuV/m)
                Any ISM                        25                       27.96                            67.96
              Any non-ISM                      15                       23.52                            63.52
       Note:
       (1) The Equipment is for 18.305(b). Any type unless otherwise specified (miscellaneous) operating frequency in any
           non-ISN frequency.
       (2) Limitation expressed in dBuV/m is calculated by 20log emission level (uV/m).
       (3) Distance extrapolation factor = 20log (specific distance / test distance) (dB), Limit line = specific limits (dBuV/m)
       + distance extrapolation factor.




                                                      Page 14 of 16


                                                                                     Report Number: SZ1905FE11
                                                                                                        Rev. 01




 Test Result
 Standard:             FCC Part 18 §18.305(b)                    Test Distance:                 3m
 Test item:            Radiated Emission                         Power:                         AC 120 V/60 Hz
 Mode:                 Mode 1 (9 kHz~30 MHz)                     Temp.(℃)/Hum.(%RH):            26(℃)/60 %RH
 Ant.Polar.:           Horizontal




          Frequency     Reading     Correct Factor    Result      Limit     Margin     Height    Degree
  No.                                                                                                       Remark
              (MHz)      (dBuV)         (dB/m)       (dBuV/m)   (dBuV/m)     (dB)       (cm)      (°)
   1          0.0090     119.58         -30.04        89.54      103.50     -13.96      100       180        peak

   2          0.1590      39.20         29.55         68.75      103.50     -34.75      100       360        peak

   3          0.2190      40.09         26.84         66.93      103.50     -36.57      100          15      peak

   4          0.4601      32.67         21.08         53.75      103.50     -49.75      100       124        peak

   5          0.6790      32.41         18.41         50.82      103.50     -52.68      100          54      peak

   6          1.3286      28.85         15.57         44.42      103.50     -59.08      100       281        peak

Note1:(1) Result (dBuV) = Correction factor (dB) + Reading(dBuV).
           Example: 89.54 = -30.04 + 119.58
        (2) Correction factor (dB/m) = Antenna Factor (dB/m) + Cable loss (dB) – Pre-Amplifier gain (dB).

Note2: The level is measured at 3 meter and is converted into result at 300 meter.
        300 m Limit (dBuV/m) change 3 m Limit (dBuV/m) = 300 m Limit (dBuV/m) + 40 log(300/3)




                                             Page 15 of 16


                                                                                     Report Number: SZ1905FE11
                                                                                                        Rev. 01




 Standard:             FCC Part 18 §18.305(b)                    Test Distance:                 3m
 Test item:            Radiated Emission                         Power:                         AC 120 V/60 Hz
 Mode:                 Mode 1 (9 kHz~30 MHz)                     Temp.(℃)/Hum.(%RH):            26(℃)/60 %RH
 Ant.Polar.:           Vertical




          Frequency     Reading    Correct Factor    Result       Limit     Margin     Height    Degree
  No.                                                                                                      Remark
              (MHz)      (dBuV)        (dB/m)       (dBuV/m)    (dBuV/m)     (dB)       (cm)      (°)
   1          0.1590      65.08         29.55         94.63      103.50      -8.87      100       145       peak

   2          0.4588      58.41         21.11         79.52      103.50     -23.98      100       123       peak

   3          0.7288      52.55         17.89         70.44      103.50     -33.06      100       274       peak

   4          1.0286      53.93         16.13         70.06      103.50     -33.44      100          0      peak

   5          1.3286      45.73         15.57         61.30      103.50     -42.20      100       186       peak

   6          1.9281      47.32         14.43         61.75      103.50     -41.75      100       312       peak

Note: 1. Result (dBuV) = Correction factor (dB) + Reading(dBuV).
          Example: 94.63 = 29.55 + 65.08
        2. Correction factor (dB/m) = Antenna Factor (dB/m) + Cable loss (dB) – Pre-Amplifier gain (dB).




                                            Page 16 of 16



Document Created: 2019-07-24 17:08:53
Document Modified: 2019-07-24 17:08:53

© 2025 FCC.report