18_600-W RFExp

FCC ID: 2AR9J-600X

RF Exposure Info

Download: PDF

Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1905009FV00
FCC ID: 2AR9J-600X




                           RF EXPOSURE REPORT
 The device described below is tested by Dongguan Nore Testing Center Co., Ltd. to determine the maximum emission
 levels emanating from the device, the severe levels which the device can endure and E.U.T.’s performance criterion.
 The test results, data evaluation, test procedures, and equipment of configurations shown in this report were made in
 accordance with the procedures in ANSI C63.10(2013).


 Applicant                    : Xigang Technologies Ltd.

 Address                      : Room 123, Building B, Lane 139, Fanghua RD, Shanghai, China

 Manufacturer/Factory         : Yuyao Durable Electric Appliance Co., Ltd.

 Address                      : Lane 38, Huanzhen North RD, DiTang Town, YuYao City, Zhejiang, China

 E.U.T.                       : Phonesoap Wireless

 Brand Name                   : N/A

 Model No.                    : 600-W, 600-G, 600-X("X" stand for variable, which can be the number 0-9
                                and the letter A-Z, it represent the color of the product appearance. for
                                example "G" represent the color gray, "W" represent the color white.)
                                (For model difference refer to section 1.1)

 FCC ID                       : 2AR9J-600X

 Measurement Standard : FCC PART 15 Subpart C

 Date of Receiver             : May 05, 2019

 Date of Test                 : May 06, 2019 to May 24, 2019

 Date of Report               : May 25, 2019


 In the configuration tested, the EUT complied with the standards specified above.



 This test report is for the customer shown above and their specific product only. This report applies to above tested
 sample only and shall not be reproduced in part without written approval of Dongguan Nore Testing Center Co., Ltd.


                     TEL: +86-769-22022444     FAX: +86-769-22022799     Web: www.ntc-c.com
             Address: Building D, Gaosheng Science and Technology park, Hongtu road, Nancheng district,
                                     Dongguan city, Guangdong province, China



                                                                                                            Page 1 of 7


Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1905009FV00
FCC ID: 2AR9J-600X



                                  1. GENERAL INFORMATION


    1.1 Product Description for Equipment under Test
        Product name              : Phonesoap Wireless

         Main model                      : 600-W

         Additional model                : 600-G, 600-X("X" stand for variable, which can be
                                           the number 0-9 and the letter A-Z, it represent the
                                           color of the product appearance. for example "G"
                                           represent the color gray, "W" represent the color
                                           white.)

         Brand name                      : N/A

         Power Supply                    : AC 100V-240V, 50/60Hz

         Test voltage                    : AC 120V /60Hz

         Adapter                         : MODEL: XS-0503100S
                                           INPUT: 100-240V~50/60Hz 0.5A
                                           OUT PUT: 5V 3100mA

         Cable                           : DC Line: 1.11m unshielded

         Software version                : V1.0

         Hardware version                : V1.0

         Note                            : N/A

         Frequency Range                 : 110.5-205KHz

         Description of model            : These models have the same circuit schematic,
         difference                        construction, PCB Layout and critical components.
                                           Their difference are the appearance colours and
                                           model name for trading purpose.

         Remark                          : According to the model difference, all tests were
                                           performed on model 600-W.




                                                                                       Page 2 of 7


Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1905009FV00
FCC ID: 2AR9J-600X




    1.2 Related Submittal(s) / Grant (s)
        This submittal(s) (test report) is intended for FCC ID: 2AR9J-600X filing to comply
        with FCC Part 15 (2017), Subpart C Rule.




    1.3 Test Facility and Location


        Site Description
        EMC     Lab         : Listed by CNAS, August 13, 2018
                              The certificate is valid until August 13, 2024
                              The Laboratory has been assessed and proved to
                              be in compliance with CNAS/CL01
                              The Certificate Registration Number is L5795.

                               Listed by A2LA, November 01, 2017
                               The certificate is valid until December 31, 2019
                               The Laboratory has been assessed and proved to
                               be in compliance with ISO17025
                               The Certificate Registration Number is 4429.01

                               Listed by FCC, November 06, 2017
                               The Designation Number is CN1214
                               Test Firm Registration Number: 907417

                              Listed by Industry Canada, June 08, 2017
                              The Certificate Registration Number. Is 46405-9743
        Name of Firm        : Dongguan Nore Testing Center Co., Ltd.
                              (Dongguan NTC Co., Ltd.)
        Site Location       : Building D, Gaosheng Science and Technology
                              park, Hongtu road, Nancheng district,
                              Dongguan city, Guangdong province, China




                                                                                    Page 3 of 7


Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1905009FV00
FCC ID: 2AR9J-600X



   2. Method of measurement

    2.1 Applicable standard

          According to 1.1307(b)(1), system operating under the provisions of this section
         shall be operated in amnner that ensures that the public is not exposed to radio
         frequency energy level in excess of the commission's guidelines.

         According to 1.1310 and 2.1093 RF exposure is calculated.
         According to KDB680106 D01V03: RF exposure wireless charging apps v03.



    2.2 Test Setup

                                                  15CM




    2.3 Test procedure

        1. The RF exposure test was performed on 360 degree turn table in anechoic
        chamber;
        2.The measurement probe was placed at test distance 15cm which is between the
        edge of the charger and 20cm between top of the charger and the geometric centre of
        probe.
        3. The turn table was rotated 360d degree to search of highest strength.
        4. The highest emission level was recorded and compared with limit as soon as
        measurement of each points (A,B,C,D,E) were completed.
        5. The EUT were measured according to the dictates of KDB 680106D01V03
                                                                                    Page 4 of 7


Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1905009FV00
FCC ID: 2AR9J-600X




    2.4 Equipment approval considerations

        1. The EUT dose comply with item 5.2 of KDB 680106D01V03
        a, Power transfer frequency is less than 1MHz.
           YES; the device operated in the frequency range from 110.5-205KHz.

        b, Output power from each primary coil is less than or equal to 15 watts
           YES; the maximum output power of the primary coil is 5W<15W.

        c, The transfer system includes only single primary and secondary coils. This includes
           charging systems that may have multiple primary coils and clients that able to
           detect and allow coupling only between individual pair of coils.
           YES; the transfer system includes only single primary and secondary coils.

        d, Client device is placed directly in contact with the transmitter.
           YES; Client device is placed directly in contact with the transmitter.

        e, Mobile exposure conditions only (portable exposure conditions are not covered by
           this exclusion).
           YES;

        f, The aggregate H-field strengths at 15cm surrounding the device and 20cm above
           the top surface from all simultaneous transmitting coils are demonstrated to be less
           than 50% of the MPE limit.
           YES; The EUT field strength levels are less than 50% x MPE limits.




                                                                                     Page 5 of 7


Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1905009FV00
FCC ID: 2AR9J-600X




    2.5 E and H field strength
        Limit

           Frequency       Electric field Magnetic field Power density
                                                                                 Averaging time
             range            strength        strength           (mW/cm2)
                                                                                     (minutes)
             (MHz)              (V/m)           (A/m)
                          (A) Limits for Occupational/Controlled Exposures
              0.3-3.0            614             1.63                *(100)               6
              3.0-30           1842/f           4.89/f             *(900/f2)              6
              30-300             61.4           0.163                   1.0               6
            300-1500              /                /                  f/300               6
          1500-100,000            /                /                     5                6
                      (B) Limits for General Population/Uncontrolled Exposure
             0.3-1.34            614             1.63               *(100)               30
             1.34-30            824/f           2.19/f             *(180/f2)             30
              30-300             27.5           0.073                   0.2              30
            300-1500              /                /                f/1500               30
           1500-100,00            /                /                    1.0              30
        F=frequency in MHz
        *=Plane-wave equivalent power density
        RF exposure compliance will need to be determined with respect to 1.1307(c) and (d) of
        the FCC rules. The emissions should be within the limits at 300kHz in Table 1 of
        1.1310(use the 300kHz limits for 150kHz:614V/m,1.63A/m).


        Test Result

        Mobile phone has been charge at zero charge, intermediate charge, and full charge.

        Electric Field Emissions
                                     Test           Probe Measure Result(V/m)            Limit     50%
        Operation        Test
                                   Distance       zero    intermediate      full         (V/m)    Limit
        frequency      Position
                                     (cm)        charge      charge       charge                  (V/m)
                        Side A        15          3.21         3.43        2.63          614       307
                        Side B        15          3.48         3.52        3.52          614       307
          124KHz        Side C        15          3.50         3.43        3.56          614       307
                        Side D        15          2.71         2.78        3.57          614       307
                        Side E        20          3.54         2.61        3.52          614       307

        Magnetic Field Emissions s
                                     Test           Probe Measure Result(A/m)           Limit      50%
        Operation        Test
                                   Distance       zero     intermediate     full        (A/m)     Limit
        frequency      Position
                                     (cm)        charge       charge      charge                  (A/m)
                       Side A         15         0.0662       0.0761      0.0715         1.63     0.815
                       Side B         15         0.0746       0.0714      0.0642         1.63     0.815
          124KHz       Side C         15         0.0728       0.0733      0.0745         1.63     0.815
                       Side D         15         0.0616       0.0745      0.0740         1.63     0.815
                       Side E         20         0.0558       0.0551      0.0652         1.63     0.815

                                                                                           Page 6 of 7


Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1905009FV00
FCC ID: 2AR9J-600X




    2.7 Test equipment list


      Description          Manufacturer      Model Number     Serial   Calibration    Calibration
                                                             Number       Date         Due Date
   3m semi-anechoic
                          Zhongyu electron    9.2*6.2*63.4    N/A      July 03,2015   July 02, 2020
       chamber
  Exposure lever tester        Narda           ELT-400       N-0231    June 29,2018 June 28, 2019
  Magnetic field probe                        ELT Probe
                               Narda                         M0675     June 29,2018 June 28, 2019
       100cm2                                  100cm2




    2.6 Test Photo




                                               ---End---