18_GS750 RFExp

FCC ID: 2AR8X-GS750

RF Exposure Info

Download: PDF
FCCID_4299107

          CERPASS TECHNOLOGY CORP.                              Report No.: TEFU1903066




                               RF Exposure Report

           Applicant       : Cooler Master Technology Inc.
                               8F., No. 788-1, Zhongzheng Rd., Zhonghe Dist., New Taipei City
           Address         :
                               23586, Taiwan
           Equipment :         Gaming Satellite

           Model No.       : GS750
           Trademark : Cooler Master
           FCC ID          : 2AR8X-GS750



    I HEREBY CERTIFY THAT :
    The sample was received on Oct. 16, 2018 and the test items were conducted during Nov. 15, 2018 at
    Cerpass Technology Corp. The test result refers exclusively to the test presented test model /
    sample. Without written approval of Cerpass Technology Corp., the test report shall not be
    reproduced except in full.


       Approved by:                               Tested by:




       Miro Chueh/ EMC/RF Manager                 Amos Zhang / Engineer


       Laboratory Accreditation:
               Cerpass Technology Corporation Test Laboratory
                    TAF LAB Code:                1439




Cerpass Technology Corp.                                                  Issued Date : Apr. 18, 2019
                                                                          Page No.     :   1 of 6


               CERPASS TECHNOLOGY CORP.                                                                    Report No.: TEFU1903066




                                                                          CONTENTS


  1. Summary Of Standards And Results ........................................................................................................ 3
    1.1. Measuring Standard .................................................................................................................................. 3
    1.2. Requirements ............................................................................................................................................ 3
    1.3. Typical test Setup ...................................................................................................................................... 4
    1.4. Specification Limits.................................................................................................................................... 4
    1.5. Test Equipment List and Details................................................................................................................ 5
    1.6. Test Result ................................................................................................................................................ 5
    1.7. Photographs of test setup ......................................................................................................................... 6




Cerpass Technology Corp.                                                                                                    Issued Date : Apr. 18, 2019
                                                                                                                            Page No.            :   2 of 6


            CERPASS TECHNOLOGY CORP.                                  Report No.: TEFU1903066


1. Summary Of Standards And Results
1.1. Measuring Standard
    The EUT have been tested according to the applicable standards as referenced below:
          Test Item              Normative References                Remarks
                               FCC CFR 47 part1, 1.1310
         RF Exposure                                                  PASS
                                 KDB680106 D01v03



1.2. Requirements
 According to the item 5 of KDB 680106 D01v03:
  Inductive wireless power transfer applications that meet all of the following requirements are
 excluded from submitting an RF exposure evaluation.


 a) Power transfer frequency is less that 1 MHz
 b) Output power from each primary coil is less than or equal to 15 watts
 c) The transfer system includes only single primary and secondary coils. This includes charging
 systems that may have multiple primary coils and clients that are able to detect and allow
 coupling only between individual pairs of coils
 d) Client device is inserted in or placed directly in contact with the transmitter
 e) Mobile exposure conditions only(portable exposure conditions are not covered by this
 exclusion).
 f) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top
 surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the
 MPE limit..
 Remark: Meet all the above requirements.




  Cerpass Technology Corp.                                                       Issued Date : Apr. 18, 2019
                                                                                 Page No.     :   3 of 6


            CERPASS TECHNOLOGY CORP.                        Report No.: TEFU1903066

1.3. Typical test Setup




1.4. Specification Limits
 The criteria listed in the following table shall be used to evaluate the environment impact of
 human exposure to radio frequency (RF) radiation as specified in 1.1307(b) Limits for Maximum
 Permissible Exposure (MPE)




  Cerpass Technology Corp.                                            Issued Date : Apr. 18, 2019
                                                                      Page No.     :   4 of 6


            CERPASS TECHNOLOGY CORP.                                 Report No.: TEFU1903066

1.5. Test Equipment List and Details
     Instrument        Manufacturer              Model No           Serial No     Calibration Date Valid Date
    EMIF Tester              Narda               ELT-400            G-0041             2019/01/16      2020/01/15



1.6. Test Result
  Electric Field Strength at 15 cm surrounding the EUT and 20cm above the top surface of
  the EUT
                   Frequency          Test       Test result(v/m)        Limit (v/m)
                     Range           Position
                     (KHz)
                  127.4~128          A: Front         0.412                614.00
                  127.4~128          B: Back          0.411                614.00
                  127.4~128           C: Left         0.423                614.00
                  127.4~128          D: Right         0.423                614.00
                  127.4~128           E: Top          0.436                614.00
                  127.4~128          F: Bottom        0.438                614.00
  Magnetic Field Strength at 15 cm surrounding the EUT and 20cm above the top surface
  of the EUT
                   Frequency          Test       Test result(A/m)        Limit (A/m)
                     Range           Position
                     (KHz)
                  127.4~128          A: Front         0.432                     1.63
                  127.4~128          B: Back          0.413                     1.63
                  127.4~128           C: Left         0.421                     1.63
                  127.4~128          D: Right         0.426                     1.63
                  127.4~128           E: Top          0.414                     1.63
                  127.4~128          F: Bottom        0.443                     1.63




  Cerpass Technology Corp.                                                        Issued Date : Apr. 18, 2019
                                                                                  Page No.     :    5 of 6


            CERPASS TECHNOLOGY CORP.   Report No.: TEFU1903066

1.7. Photographs of test setup




  Cerpass Technology Corp.                     Issued Date : Apr. 18, 2019
                                               Page No.     :   6 of 6



Document Created: 2019-05-09 22:05:03