MPE Report

FCC ID: 2AR77TIBURNNCC1701A

RF Exposure Info

Download: PDF
FCCID_4160125

                                        FCC RF EXPOSURE REPORT

                                                            For


                                                Personal Computer

                                  MODEL NUMBER: Tiburn NCC-1701-A

                                     FCC ID: 2AR77TIBURNNCC1701A


                                     REPORT NUMBER:4788636465-12

                                      ISSUE DATE: December 21, 2018



                                                      Prepared for

                                Tiburn Technology Co., Ltd.
    606, 6 / f, Building 10, No. 44, Beisanhuan middle road, Haidian district, Beijing



                                                      Prepared by

     UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
          Building 10, Innovation Technology Park, No. 1, Li Bin Road,
Song Shan Lake Hi-Tech Development Zone, Dongguan, People’s Republic of China
                              Tel: +86 769-22038881
                              Fax: +86 769 33244054
                              Website: www.ul.com




The results reported herein have been performed in accordance with the laboratory’s terms of accreditation. This report
shall not be reproduced except in full without the written approval of the Laboratory. The results in this report apply to the
test sample(s) mentioned above at the time of the testing period only and are not to be used to indicate applicability to
other similar products. This report does not imply that the product(s) has met the criteria for certification.


                                                                                  REPORT No.: 4788636465-12
                                                                                            Page 2 of 6

                                                 Revision History

            Issue Date
Rev.                                                      Revisions                                     Revised By
V0          12/21/2018                                   Initial Issue




                 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
     This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                  (Guangzhou) Co., Ltd, Song Shan Lake Branch.


                                                                                          REPORT No.: 4788636465-12
                                                                                                    Page 3 of 6
                                           TABLE OF CONTENTS
1.   ATTESTATION OF TEST RESULTS ................................................................................. 4

2.   TEST METHODOLOGY ..................................................................................................... 4

3.   FACILITIES AND ACCREDITATION ................................................................................. 5

4.   REQUIREMENT ................................................................................................................. 6




                   UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
      This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                   (Guangzhou) Co., Ltd, Song Shan Lake Branch.


                                                                                  REPORT No.: 4788636465-12
                                                                                            Page 4 of 6

1. ATTESTATION OF TEST RESULTS
 Applicant Information
 Company Name:                        Tiburn Technology Co., Ltd.

 Address:                             606, 6 / f, Building 10, No. 44, Beisanhuan middle road, Haidian
                                      district, Beijing

 Manufacturer Information
 Company Name:                        Tiburn Technology Co., Ltd.

 Address:                             606, 6 / f, Building 10, No. 44, Beisanhuan middle road, Haidian
                                      district, Beijing


 EUT Description
 EUT Name:                            Personal Computer
 Model:                               Tiburn NCC-1701-A
 Brand Name:                          Tiburn
                                      Tiburn NCC-1701-A*, 1000*
 Series Model                         (Where * maybe any alphanumeric character, symbol or blank of
                                      0~7 digits, for marketing purpose.)
 Model Difference                     All the same except for the model name.
 Sample Received Date:                December 2, 2018
 Sample ID:                           12467549
 Sample Status:                       Normal
 Date of Tested:                      December 10, 2018 ~ December 20, 2018

                                        APPLICABLE STANDARDS
                              STANDARD                                                 TEST RESULTS
                          FCC 47CFR§2.1091                                                    PASS
                        KDB-447498 D01 V06                                                    PASS

Tested By:                                                      Checked By:




Denny Huang                                                    Shawn Wen
Engineer Project Associate                                     Laboratory Leader
Approved By:




Stephen Guo
Laboratory Manager

                 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
     This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                  (Guangzhou) Co., Ltd, Song Shan Lake Branch.


                                                                                  REPORT No.: 4788636465-12
                                                                                            Page 5 of 6
2. TEST METHODOLOGY
The tests documented in this report were performed in accordance with KDB 447498 D01
General RF Exposure Guidance v06.


3. FACILITIES AND ACCREDITATION
                        A2LA (Certificate No.: 4102.01)
                        UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch.
                        has been assessed and proved to be in compliance with A2LA.
                        FCC (FCC Designation No.: CN1187)
                        UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch.
                        Has been recognized to perform compliance testing on equipment subject
                        to the Commission's Delcaration of Conformity (DoC) and Certification
                        rules
                        IC(Company No.: 21320)
Accreditation
                        UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch.
Certificate
                        has been registered and fully described in a report filed with
                        Industry Canada. The Company Number is 21320.
                        VCCI (Registration No.: G-20019, R-20004, C-20012 and T-20011)
                        UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch.
                        has been assessed and proved to be in compliance with VCCI, the
                        Membership No. is 3793.
                        Facility Name:
                        Chamber D, the VCCI registration No. is G-20019 and R-20004
                        Shielding Room B , the VCCI registration No. is C-20012 and T-20011

Note 1: All tests measurement facilities use to collect the measurement data are located at
Building 10, Innovation Technology Park, Song Shan Lake Hi tech Development Zone,
Dongguan, 523808, China

Note 2 : For below 30MHz, lab had performed measurements at test anechoic chamber and
comparing to measurements obtained on an open field site. These measurements below
30MHz had been correlated to measurements performed on an OATS.




                 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
     This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                  (Guangzhou) Co., Ltd, Song Shan Lake Branch.


                                                                                  REPORT No.: 4788636465-12
                                                                                            Page 6 of 6

4. REQUIREMENT
LIMIT
Limits for General Population/Uncontrolled Exposure

                         Limits for General Population/Uncontrolled Exposure
                         Electric Field      Magnetic Field               Power                   Averaging Time
 Frequency Range
                         Strength (E)        Strength (H)              Density (S)                 |E|2, |H|2 or S
   (MHz)
                           (V/m)                (A/m)                  (mW/cm2)                      (minutes)
      0.3-1.34               614                  1.63                    (100)*                          30
      1.34-30                824/f                2.19/f                 (180/f2)*                        30
      30-300                 27.5                 0.073                     0.2                           30
     300-1500                  --                   --                     f/150                          30
   1500-100,000                --                   --                      1.0                           30
Note 1: f = frequency in MHz, * means Plane-wave equivalent power density

Note 2: General population/uncontrolled exposures apply in situations in which the general
public may be exposed, or in which persons that are exposed as a consequence of their
employment may not be fully aware of the potential for exposure or cannot exercise control over
their exposure.

Note 3: The limit value 1.0mW/cm2 is available for this EUT.



MPE CALCULATION METHOD

             2
S =PG/(4πR )


where: S = power density (in appropriate units, e.g. mW/ cm2)
P = power input to the antenna (in appropriate units, e.g., mW)
G = power gain of the antenna in the direction of interest relative to an isotropic radiator
R = distance to the center of radiation of the antenna (appropriate units, e.g., cm)




                 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
     This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                  (Guangzhou) Co., Ltd, Song Shan Lake Branch.


                                                                                  REPORT No.: 4788636465-12
                                                                                            Page 7 of 6
CALCULATED RESULTS

Radio Frequency Radiation Exposure Evaluation

                                                    BLE Mode

 Frequency       Output Power        Output Power         Power Density              Limit            Test Result

    MHz               dBm                  mW                 mW/cm2               mW/cm2                   --

 2402~2480             1.0                 1.26                0.0004                 1.0              Complies


                                              9560NGW BT Mode

 Frequency       Output Power         Output Power        Power Density               Limit           Test Result

    MHz                dBm                  mW                mW/cm2               mW/cm2                   --

 2402~2480              12                 15.85                0.006                  1.0             Complies


                                          9560NGW 2.4G WiFi Mode

 Frequency       Output Power         Output Power        Power Density               Limit           Test Result

    MHz                dBm                  mW                mW/cm2               mW/cm2                   --

 2412~2472              30                 1000                 0.354                  1.0             Complies


                                           9560NGW 5G WiFi Mode

 Frequency       Output Power         Output Power        Power Density               Limit           Test Result

    MHz                dBm                  mW                mW/cm2               mW/cm2                   --

 5150~5825              30                316.23                0.096                  1.0             Complies



Note: 1. Antenna Gain=2.10dBi (Numeric 1.62) for BT; Antenna Gain=2.5dBi (Numeric 1.78) for
9560NGW 2.4G, Antenna Gain=1.85dBi (Numeric 1.1.53) for 9560NGW 5.8G, π=3.141.
      2. The BLE power comes from turn up power which declared by customer. The power of
the 9560NGW module comes from the original test report.
      3. The minimum separation distance of the device is greater than 20 cm.
      4. All of transmitter function can Tx simultaneously for the EUT, so the combined Power
Density is 0.004+0.006+0.354+0.096=0.46mW/cm2 less than 1.0mW/cm2.
      5. Calculate by WORST-CASE mode.




                 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
     This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                  (Guangzhou) Co., Ltd, Song Shan Lake Branch.


(Up )
        __J



Document Created: 2019-01-30 11:42:20
Document Modified: 2019-01-30 11:42:20

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC