RF Exposure Info

FCC ID: 2AR38-001

RF Exposure Info

Download: PDF
FCCID_4178874

                                       SGS-CSTC Standards Technical Services Co., Ltd.
                                       Guangzhou Branch

 198 Kezhu Road, Scientech Park, Guangzhou Economic & Technological
 Development District, Guangzhou, China 510663
 Telephone: +86 (0) 20 82155555                                                       Report No.: GZEM181200539402
 Fax:       +86 (0) 20 82075059                                                       Page:       1 of 12
 Email:        ee.guangzhou@sgs.com



                                             TEST REPORT
Application No.:           GZEM1812005394CR
Applicant:                 GMY LIGHTING TECHNOLOGY CO.,LTD.
Address of Applicant:      No.328 Xinxing Road, Gonghe Town, Heshan City, Guangdong, China
Manufacturer:              The same as applicant
Address of Manufacturer:   The same as applicant
Factory:                   The same as applicant
Address of Factory:        The same as applicant
Equipment Under Test (EUT):
EUT Name:                  LED Filament Bulb
Model No.:                 A19YY-4.5D-Z01-XXZZ, A21YY-4.5D-Z01-XXZZ, A23YY-4.5D-Z01-XXZZ,
                           ST19YY-4.5D-Z01-XXZZ, ST21YY-4.5D-Z01-XXZZ, G25YY-4.5D-Z01-XXZZ,
                           G30YY-4.5D-Z01-XXZZ, G40YY-4.5D-Z01-XXZZ
                           (XX=00-99, ZZ=00-99, Y=A-Z). ¤
¤                          Please refer to section 2 of this report which indicates which model was
                           actually tested and which were electrically identical.
Standard(s) :              47 CFR Part 1.1307, Part 2.1093, KDB 447498
Date of Receipt:           2018-12-13
Date of Test:              2018-12-19 to 2019-01-15
Date of Issue:             2019-01-21
Test Result:                Pass*
* In the configuration tested, the EUT complied with the standards specified above.




                 Kobe Jian
                Lab Manager
The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report.
If the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure the new
system complies with all relevant standards. Any mention of SGS International Electrical Approvals or testing done by SGS International
Electrical Approvals in connection with, distribution or use of the product described in this report must be approved by SGS International
Electrical Approvals in writing.


                           SGS-CSTC Standards Technical Services Co., Ltd.
                           Guangzhou Branch
                                                         Report No.: GZEM181200539402
                                                         Page:       2 of 12


                                       Revision Record

Version      Chapter            Date               Modifier               Remark

   01                         2019-01-21                                  Original




Authorized for issue by:




Tested By
                                                                   2018-12-19 to 2019-01-15

                             Jackson_Yuan /Project Engineer        Date




Checked By
                                                                   2019-01-21

                             Ricky_Liu /Reviewer                   Date


                             SGS-CSTC Standards Technical Services Co., Ltd.
                             Guangzhou Branch
                                                                 Report No.: GZEM181200539402
                                                                 Page:       3 of 12



2   Test Summary
    Radio Spectrum Technical Requirement
             Item                Standard                 Method               Requirement          Result
                            47 CFR Part 1.1307,
        RF Exposure          Part 2.1093, KDB       CFR 47 Part 2.1093      CFR 47 Part 2.1093       Pass
                                  447498

    ¤ Declaration of EUT Family Grouping:
    Model No.: A19YY-4.5D-Z01-XXZZ, A21YY-4.5D-Z01-XXZZ, A23YY-4.5D-Z01-XXZZ, ST19YY-4.5D-
    Z01-XXZZ, ST21YY-4.5D-Z01-XXZZ, G25YY-4.5D-Z01-XXZZ, G30YY-4.5D-Z01-XXZZ, G40YY-4.5D-
    Z01-XXZZ
    (XX=00-99, ZZ=00-99, Y=A-Z)
    According to the declaration from the applicant, the electrical circuit design, layout, components used
    and internal wiring were identical for all models, with only difference on the appearance and rated
    power.

    Therefore only one model A19CL-4.5D-Z01-2750 with maximum rated power was tested in this report.


                                                                  SGS—CSTC Standards Technical Services Co., Ltd.
                                                                  Guangzhou Branch
                                                                                                                                                  Report No.: GZEM181200539402
                                                                                                                                                  Page:                    4 of 12



3             Contents
                                                                                                                                                                                                                    Page
1         COV@F PAG@.............«c«ssrssrrrrsrrrrrrrrrsrrrsssrssssssssssssssssrsssssssssssssssssssrsssrssrxssssrsssssssssssssssssssssssaaasaaassskssskksskkkkkkksnnnns 1

2         Te@St SUMIM@FY...............ccccsccosssnssssnssssnssssssssssssssersrrrssrssssssssssssssssssssssssaaasaaaaaaaasssassssasskksskkkkkkkksskkksskksaaa8aaaanan ns 3

3         CONI@MTS ...........csss00ssserrrrrrnnnnnirrrrrrrrrnnnsnsrrarrr snn nnn en rrnnnnnnnn in rrr n n snn n n n n n n in n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n ns 4

4         GeN@er@l INnfOFM@TION .................ssssssssssssssrrrrrssssssrerrrrssssssrrrrrrrrrsnnsnnrrarrrrr snn snn n ar n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n ns 5
    4.1             DEet@il$ Of E.U.T.......2202222222240r¥r¥¥¥eeerrrrrrerrrrrrerrrr se se vrrreresrrrrressrrrrrresrrrrrsssrrrrrsserrrrrrsrrrer se se rr iss se a ie es se aa e e ks k a00 5
    4.2             Description Of SUPPOFt UNItS .............22...222222222rrrrrrvvvvrvvvrvvrrssrrsssssssssssr se s iss i ie i i se rrrrrrrrrrrrrer e e e e e e e e e e e e e e k e k a04 5
    4.3             M EET )c iae blaleclee ts e 5
    4.4             CSc( e 6
    4.5             T@St FACIIItY .....22222222220020222rr¥4464¥¥¥r iss r¥rvvvasvrrrrvvrrrrv s i rrev is i rrr kess is a k es ki ar k k k e i¥ r¥ k k ki is¥ k k k e ki 6k k k k ki e 6k k e aaa e e k e e e ie e e e k e w aa en 7
    4.6             DPEMEii(e s (colupfheic ale CleoC 8
    4.7             Abnormalities from Stand@rd CONQItiONS .................00000000022rrer e r s rr se e e e e e e e rrr e e e e rr e e e e e e e e e e e e e e e e e e e e a e e e es 8
5         Equiipment LiISt . . . . . . . . . . . ... mm mm mm mm mm n n m en nn n n nnn n n en n n n en ies na en kn n n n n es 9

6         Radio Spectrum Technical R@QUIF@M@NT ................00csscsssssssssssserssssrrrrrrrsrrsrrrssrrrsssrrrsrssssrssssassssssssssss8a8a008 10
    6.1              Mise >on e 10
          6.1.1          TeSst R@QUIF@M@NT! ...........222222222222222222rr66r6ar¥¥rrrrrvsssrrrrrrkksrrss iss rrrkrrrssssasrrrrrkksk kss ssrrrkrkea s k ks k k k k k k k k k k k k00 10
          6.1.2           MPE C@ICUIAtiON MQthOGU .........22222222200000020002224rrrr e e rrrrrrrrrrrrrrrrrrr e e e e e e e e e e e e e e e e e e e e e e e e a e a e en e en e en e e e e 11
          6.1.3          CAICUuI@ated R@SUIt ANU LIMit.......2..2.22.00002222¥¥¥¥¥¥er t rrrrrrrvrvrrrrrrrrerrrvvrrrrrrr is se se e @rr i i6 ie e i se e rrrr e e e e e e e e raaa e 11
7         P HOTOGFAD NS . . . 2 2 2 2 2200000000000 mm im m mm i i in n n n n i i i n n m i w e n w e n n e w i n m n n e w i n n e w i n n n e n i n n n w n i n e i n i n n n n i i n e i n i n n e i i i n e w i i n w n n i 12
    7.1              EUT CONStrUCtiON@I D@QtAIIS............2222222002226¥¥¥¥¥¥¥¥¥err e rrrrrrrvrvrrrrrrrrerrrrvrrrrirr i se e rrrarr i i i i ie i se aaarr ie e e e e e e raaa e 00 12




                                                Unless otherwise agreed in writing, this document is issued by the Company subject to its General Conditions of Service printed
                                                overlieaf, available on request or accessible at http://www.sqs.com/en/Terms—and—Conditions.aspx and, for electronic format documents,
                                                subject to Terms and Conditions for Electronic Documents at http://www.sqs.com/en/Terms—and—Conditions/Terms—e—Document.aspx.
                                                Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is
                                                advised that information contained hereon reflects the Company‘s findings at the time of its intervention only and within the limits of
                                                Client‘s instructions, if any. The Company‘s sole responsibility                        is to its Client and this document does not exonerate parties to a
                                                transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced
                                                except in full, without prior written approval of the Company. Any unauthorized alteration, for%ery or falsification of the content or
     c cepmtne *                                appearance of this document is unlawful and offenders may be prosecuted to the fullest extent         the law. Unless otherwise stated the
                                                results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 30 days only.
    r«%;)Inspectum & Testing Services
                                   §
                                                Attentlon To check the authenticity of testing /inspection report & certificate, please contact us at telephone: (86—755)8307 1443,
                                                         1: CN.Doccheck@sgs.com
                       chnicales Co. Ltd. No198KezhuRoad Scientech Park, Guangzhou Economic & Technology Development District, Guangzhou, China 510663
                                                                   chec
                                                                                                                                                         t (86—20) 82155555 f (86—20) 82075058 www.sgsgroup.com.cn
                       [E \' C Laboratory. 1B JUMN —ZHRARATEEEREPREIIR1OSS                                                         BB&M: 510663 t (86—20) 82155555 f (86—20) 82075058 sqs.china@sgs.com
                                                I
                                                                                                                                                                       Member of the SGS Group (SGS SA)


                               SGS-CSTC Standards Technical Services Co., Ltd.
                               Guangzhou Branch
                                                      Report No.: GZEM181200539402
                                                      Page:       5 of 12


4   General Information
4.1 Details of E.U.T.
    Power Supply:               AC 120 V, 60 Hz
    Rated Power:                4.5W
    Test Voltage:               AC 120 V, 60 Hz
    Cable:                      Cap E26
    Antenna Gain                0 dBi
    Antenna Type                Integral Antenna
    Channel Spacing             5MHz
    Number of Channels          15
    Modulation Type             O-QPSK
    Operation Frequency         2405MHz to 2475MHz


4.2 Description of Support Units
            Description               Manufacturer   Model No.                Serial No.
             DC power                  ZHAOXIN       RXN-305D             REF. No.SEA2700


4.3 Measurement Uncertainty

      No.                      Item                  Measurement Uncertainty
       1                  Radio Frequency                   ±5.5 x 10-8
       2                    Duty cycle                       ±0.57%
       3             Occupied Bandwidth                          ±3%
       4             RF Conducted power                      ±0.68dB
       5             RF Power Density                         ±1.50dB
       6        Conducted Spurious Emissions                  ±1.04dB
                                                        ±4.5dB (below 1GHz)
       7                RF Radiated Power
                                                        ±4.8dB (above 1GHz)
                                                       ±4.5dB (30MHz-1GHz)
       8        Radiated Spurious Emission Test
                                                       ±4.8dB (1GHz-18GHz)
        9                  Temperature                        ±0.4°C
       10                    Humidity                          ±1.3%
       11                 Supply Voltages                      ±1.5%
       12                      Time                             ±3%


                             SGS-CSTC Standards Technical Services Co., Ltd.
                             Guangzhou Branch
                                                           Report No.: GZEM181200539402
                                                           Page:       6 of 12


4.4 Test Location
    All tests were performed at:
    SGS-CSTC Standards Technical Services Co., Ltd., Guangzhou Branch EMC Laboratory,
    198 Kezhu Road, Scientech Park, Guangzhou Economic & Technology Development District,
    Guangzhou, China 510663
    Tel: +86 20 82155555        Fax: +86 20 82075059
    No tests were sub-contracted.


                                                    SGS—CSTC Standards Technical Services Co., Ltd.
                                                    Guangzhou Branch
                                                                                                                             Report No.: GZEM181200539402
                                                                                                                             Page:                        7 of 12


4.5 Test Facility
       The test facility is recognized, certified, or accredited by the following organizations:

       © NVLAP (Lab Code: 200611—0)
       SGS—CSTC Standards Technical Services Co., Ltd., Guangzhou EMC Laboratory is accredited by the
       National Voluntary Laboratory Accreditation Program (NVLAP/NIST). NVLAP Code: 200611—0.
       The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any
       agency of the Federal Government.

       ©@ ACMA

       SGS—CSTC Standards Technical Services Co., Ltd., EMC Laboratory can also perform testing for the
       Australian C—Tick mark as a result of our NVLAP accreditation.
       e SGS UK(Certificate No.: 32), SGS—TUV SAARLAND and SGS—FIMKO
       Have approved SGS—CSTC Standards Technical Services Co., Ltd., EMC Laboratory as a supplier of
       EMC TESTING SERVICES and SAFETY TESTING SERVICES.
       © CNAS (Lab Code: LO167)
       SGS—CSTC Standards Technical Services Co., Ltd., EMC Laboratory has been assessed and in
       compliance with CNAS—CLO1:2006 accreditation criteria for testing laboratories (identical to

       ISO/IEC 17025:2005 General Requirements) for the Competence of Testing Laboratories.
       @FCC Recognized 2.948 Listed Test Firm(Registration No.: 282399)
       SGS—CSTC Standards Technical Services Co., Ltd., EMC Laboratory has been registered and fully
       described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter
       from the FCC is maintained in our files. Registration 282399, May 31, 2002.
       @FCC Recognized Accredited Test Firm(Registration No.: 486818)
       SGS—CSTC Standards Technical Services Co., Ltd., EMC Laboratory has been accredited and fully
       described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter
       from the FCC is maintained in our files. Designation Number: CN5016, Test Firm Registration Number:
       486818, Jul 13, 2017.
       e Industry Canada (Registration No.: 4620B—1)
       The 3m/10m Alternate Semi—anechoic chamber of SGS—CSTC Standards Technical Services Co., Ltd.,
       has been registered by Certification and Engineering of Industry Canada for radio equipment testing
       with Registration No. 4620B—1.
       ® VCCI (Registration No.: R—12460, C—12584, G—10449 and T—11179)

       The 10m Semi—anechoic chamber and Shielded Room of SGS—CSTC Standards Technical Services
       Co., Ltd. have been registered in accordance with the Regulations for Voluntary Control Measures with
       Registration No.: R—12460, C—12584, G—10449 and T—11179 respectively.
       ©@ CBTL (Lab Code: TL129)
       SGS—CSTC Standards Technical Services Co., Ltd., E&E Laboratory has been assessed and fully
       comply with the requirements of ISO/IEC 17025:2005, the Basic Rules, IECEE 01 and Rules of
       procedure IECEE 02, and the relevant IECEE CB—Scheme Operational documents.


                                   Unless otherwise agreed in writing, this document is issued by the Company subject to its General Conditions of Service printed
                                   overlieaf, available on request or accessible at http://www.sqs.com/en/Terms—and—Conditions.aspx and, for electronic format documents,
                                   subject to Terms and Conditions for Electronic Documents at http://www.sqs.com/en/Terms—and— Conditions/Terms—e—Document. aspx.
                                   Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is
                                   advised that information contained hereon reflects the Company‘s findings at the time of its intervention only and within the limits of
                                   Client‘s instructions, if any. The Company‘s sole responsibility                is to its Client and this document does not exonerate parties to a
                                   transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced
                                   except in full, without prior written approval of the Company. Any unauthorized alteration, for%ery or falsification of the content or
  #@lfigflflgfifig                      appearance of this document is unlawful and offenders may be prosecuted to the fullest extent         the law. Unless otherwise stated the
   Inspection & Testing Services   results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 30 days only.
  %                         @      Attentlon To check the authenticity of testing /inspection report & certificate, please contact us at telephone: (86—755) 8307 1443,
                                            1: CN.Doccheck@sgs.com
                                   No198KezhuRoad Scientech Park, Guangzhou Economic & Technology Development District, Guangzhou, China 510663 t (86—20) 82155555 f (86—20) 82075058 www.sgsgroup.com.cn
                                       1B +JX —ZFHRERRTEERNEHERRR198S                                          BBZ: 510663 t (86—20) 82155555 f (86—20) 82075058 sgs.china@sgs.com
                                   I
                                                                                                                                                    Member of the SGS Group (SGS SA)


                      SGS-CSTC Standards Technical Services Co., Ltd.
                      Guangzhou Branch
                                             Report No.: GZEM181200539402
                                             Page:       8 of 12


4.6 Deviation from Standards
    None
4.7 Abnormalities from Standard Conditions
    None


                             SGS-CSTC Standards Technical Services Co., Ltd.
                             Guangzhou Branch
                                                              Report No.: GZEM181200539402
                                                              Page:       9 of 12



5   Equipment List
    General used equipment
                                                                Inventory
          Equipment            Manufacturer        Model No                  Cal Date    Cal Due Date
                                                                   No
             DMM                   Fluke              73        EMC0006     2018-07-20    2019-07-19
             DMM                   Fluke              73        EMC0007     2018-07-19    2019-07-18


    Conducted Peak Output Power
                                                                Inventory
          Equipment            Manufacturer        Model No                  Cal Date    Cal Due Date
                                                                   No
      EXA Signal Analzer     AgilentTechnologies   N9010A       EMC2138     2018-11-19   2019-11-18
        6dB Attenuator               HP             8491A       EMC2062     2018-04-04   2020-04-03
    Test Software JS1120-3     HangTianXing          V2.6       GZE100-69      N/A           N/A


                              SGS-CSTC Standards Technical Services Co., Ltd.
                              Guangzhou Branch
                                                                 Report No.: GZEM181200539402
                                                                 Page:       10 of 12


6     Radio Spectrum Technical Requirement
6.1 RF Exposure
6.1.1 Test Requirement:
      Systems operating under the provisions of this section shall be operated in a manner that ensures that
      the public is not exposed to radio frequency energy level in excess limit for maximum permissible
      exposure. In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined
      as a mobile device whereby a distance of 0.2m normally can be maintained between the user and the
      device.
(a) Limits for Occupational / Controlled Exposure
Frequency Range           Electric Field     Magnetic Field                             Averaging Times
                                                                   Power Density
                          Strength (E)        Strength (H)                       2       ‫׀‬E‫ ׀‬2 ,‫׀‬H‫ ׀‬2or S
       (MHz)                                                        (S)(mW/cm )
                              (V/m)              (A/m)                                     (minutes)
      0.3-3.0               614                1.63                (100)*                  6
      3.0-30               1842/f              4.89/f              (900/f)*                6
      30-300                61.4               0.163                 1.0                   6
     300-1500                --                  --                F/300                   6
    1500-100000              --                  --                   5                    6

(b) Limits for General Population / Uncontrolled Exposure
Frequency Range        Electric Field    Magnetic Field                            Averaging Times
                                                               Power Density
                        Strength (E)      Strength (H)                              ‫׀‬E‫ ׀‬2 ,‫׀‬H‫ ׀‬2or S
       (MHz)                                                    (S)(mW/cm2)
                           (V/m)              (A/m)                                   (minutes)
      0.3-1.34              614                1.63                (100)*                 30
      1.34-30              824/f               2.19/f              (180/f)*               30
      30-300                27.5               0.073                 0.2                  30
     300-1500                --                  --                F/1500                 30
    1500-100000              --                  --                  1.0                  30
Note: f=frequency in MHz; *Plane-wave equivalent power density


                               SGS-CSTC Standards Technical Services Co., Ltd.
                               Guangzhou Branch
                                                                Report No.: GZEM181200539402
                                                                Page:       11 of 12


  6.1.2 MPE Calculation Method
        E (V/m)=(30*P*G)0.5/d Power Density: Pd(W/m2)=E2/377
        E=Electric Field (V/m)
        P=Peak RF output Power (W)
        G=EUT Antenna numeric gain (numeric)
        d= Separation distance between radiator and human body (m)
        The formula can be changed to
        Pd= (30*P*G)/(377*d2)
        From the peak EUT RF output power, the minimum mobile separation distance, d=0.2m, as well as
        the gain of the used antenna, the RF power density can be obtained.


  6.1.3 Calculated Result and Limit


                                                                              Limit of
   Frequency      Antenna      Peak Output                                     Power
                                               Peak Output   Power Density                   Test
                   Gain          Power                                       Density (S)
     (MHz)                                     Power (mW)     (S) (mW/cm2)                  Result
                 (Numeric)        (dBm)
                                                                             (mW/cm2)
      2405          1.000            -22.745      0.005        0.000001          1         Complies
      2445          1.000            -22.951      0.005        0.000001          1         Complies
      2475          1.000            -22.392      0.006        0.000001          1         Complies

So the SAR report is not required.


                           SGS-CSTC Standards Technical Services Co., Ltd.
                           Guangzhou Branch
                                                            Report No.: GZEM181200539402
                                                            Page:       12 of 12



7   Photographs

7.1 EUT Constructional Details

       Refer to Appendix A - Photographs of EUT Constructional Details for GZEM1812005394CR.

                                        --End of Report—



Document Created: 2019-02-18 08:16:51
Document Modified: 2019-02-18 08:16:51

© 2024 FCC.report