RF Exposure Report

FCC ID: 2AR2STAPH802

RF Exposure Info

Download: PDF
FCCID_4377793

                    Test Report No.: FM190527N055


                                   RF EXPOSURE REPORT
   Applicant                       MMD Hong Kong Holding Limited

                                   Units 1006-1007, 10th Floor, C-Bons International Center, 108 Wai Yip Street, Kwun
   Address
                                   Tong, Kowloon, Hong Kong


   Manufacturer or
                                   MMD Hong Kong Holding Limited
   Supplier
                                   Units 1006-1007, 10th Floor, C-Bons International Center, 108 Wai Yip Street, Kwun
   Address
                                   Tong, Kowloon, Hong Kong

   Product                         Bluetooth Over-ear headband headphones

   Brand Name                      Philips

   Model                           TAPH802

   Additional Model &
                                   TAPH802xx/yy, xx=colour, yy=country destination; see section 1
   Model Difference

   Date of tests                   May 27, 2019 ~ Jun. 13, 2019

        FCC Part 2 (Section 2.1093)
        KDB 447498 D01
        IEEE C95.1

   CONCLUSION: The submitted sample was found to COMPLY with the test requirement

                         Tested by Tom Chen                                                            Approved by Glyn He
                 Project Engineer / EMC Department                                                  Supervisor/ EMC Department




                                                                                                            Date: Jul. 23, 2019
   This report is governed by, and incorporates by reference, CPS Conditions of Service as posted at the date of issuance of this report at
   http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/and is intended for your exclusive use. Any copying or
   replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This
   report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or
   representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and
   expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us.
   Measurement uncertainty is only provided upon request for accredited tests. You have 60 days from date of issuance of this report to notify us of any
   material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing
   and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute you unqualified
   acceptance of the completeness of this report, the tests conducted and the correctness of the report contents.



                                                    No. 34, Chenwulu Section, Guantai Rd., Houjie              Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                                    Town, Dongguan City,                                       Fax: +86 769 8593 1080
Dongguan Branch
                                                    Guangdong 523942, China                                    Email: customerservice.dg@cn.bureauveritas.com
                                                                         Page 1 of 6                                                             Report Version 1


                Test Report No.: FM190527N055




                                          Table of Contents
   RELEASE CONTROL RECORD ................................................................................ 3
   1.       CERTIFICATION .............................................................................................. 4
   2.       RF EXPOSURE DEFINE ................................................................................. 5
   3.       CLASSIFICATION ........................................................................................... 5
   4.       SAR TEST EXCLUSION THRESHOLDS ........................................................ 6




                                         No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                         Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                         Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                           Page 2 of 6                                                   Report Version 1


                Test Report No.: FM190527N055


                               RELEASE CONTROL RECORD

    ISSUE NO.                REASON FOR CHANGE                                                      DATE ISSUED

    FM190527N055             Original release                                                         Jul. 23, 2019




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                       Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                       Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                        Page 3 of 6                                                    Report Version 1


                Test Report No.: FM190527N055

   1. CERTIFICATION

                        FCC ID:     2AR2STAPH802
                   PRODUCT:         Bluetooth Over-ear headband headphones

              BRAND NAME:           Philips

                 MODEL NO.:         TAPH802

         ADDITIONAL NO.:            TAPH802xx/yy, xx=colour, yy=country destination

                 APPLICANT:         MMD Hong Kong Holding Limited

               STANDARDS:           FCC Part 2 (Section 2.1093)

                                    KDB 447498 D01

                                    IEEE C95.1

   NOTES:
   1. Additional models TAPH802xx/yy, xx=color, yy=country destination are identical with the test
      model TAPH802 except the color of appearance and model number for trading purpose.




                                     No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                     Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                     Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                      Page 4 of 6                                                    Report Version 1


                Test Report No.: FM190527N055

   2. RF EXPOSURE DEFINE
   The corresponding SAR Exclusion Threshold condition, listed below:

   1) The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances
     ≤ 50 mm are determined by:
     [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,
     mm)] ·[√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR,16 where
          f(GHz) is the RF channel transmit frequency in GHz
        Power and distance are rounded to the nearest mW and mm before calculation
          The result is rounded to one decimal place for comparison
     The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and
     for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation
     distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion.
   2) At 100 MHz to 6 GHz and for test separation distances > 50 mm, the SAR test exclusion threshold
     is determined according to the following:
     a) [Threshold at 50 mm in step 1) + (test separation distance - 50 mm)·( f(MHz)/150)] mW, at
       100MHz to 1500 MHz
     b) [Threshold at 50 mm in step 1) + (test separation distance - 50 mm)·10] mW at > 1500 MHz and ≤
       6 GHz
   3) At frequencies below 100 MHz, the following may be considered for SAR test exclusion.
     a) The threshold at the corresponding test separation distance at 100 MHz in step 2) is multiplied by
       [1 + log(100/f(MHz))] for test separation distances > 50 mm and < 200 mm.
     b) The threshold determined by the equation in a) for 50 mm and 100 MHz is multiplied by ½ for test
       separation distances ≤ 50 mm.
     c) SAR measurement procedures are not established below 100 MHz. When SAR test exclusion
       cannot be applied, a KDB inquiry is required to determine SAR evaluation requirements for any
       test results to be acceptable.


   3. CLASSIFICATION
   The antenna of this product, under normal use condition, is at less than 20cm away
   from the body of the user. So, this device is classified as Portable Device.




                                     No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                     Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                     Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                      Page 5 of 6                                                    Report Version 1


                Test Report No.: FM190527N055

   4. SAR TEST EXCLUSION THRESHOLDS

   The tuned conducted Average Power (declared by client)

                                            Target                                   Lower                   Upper
                        Frequency                             Tolerance
      Mode                                  Power                                  Tolerance               Tolerance
                          (MHz)                                 (dBm)
                                            (dBm)                                    (dBm)                   (dBm)
      GFSK              2402-2480              1                  +-1                    0                       2
     8DPSK              2402-2480              1                  +-1                    0                       2


   The measured conducted Average Power

                                                Frequency                               Averaged Power
                Mode
                                                  (MHz)                                      (dBm)

               GFSK                                2480                                         1.61
               8DPSK                               2480                                         1.29



   SAR Test Exclusion Thresholds


                          Maximum
                       source-based          Minimum                                           Limit for
    Frequency          time averaged        separation         Result of      Limit for          10-g
                                                                                                                 Verdict
      (MHz)              conducted           distance           Eq. 1         1-g SAR          extremity
                        output power           (mm)                                              SAR
                           (dBm)
                                                                                                                  Exempt
     2402-2480                 2                   5            0.49918           3.0               7.5            from
                                                                                                                   SAR

   Conclusion

   Therefore this device complies with FCC’s RF radiation exposure limits for general population without
   SAR evaluation.


    --- END ---




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie    Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                       Town, Dongguan City,                             Fax: +86 769 8593 1080
Dongguan Branch
                                       Guangdong 523942, China                          Email: customerservice.dg@cn.bureauveritas.com
                                                        Page 6 of 6                                                     Report Version 1



Document Created: 2019-07-23 14:35:16
Document Modified: 2019-07-23 14:35:16

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC