Test Report

FCC ID: 2AR2O-VOB-P3310

Test Report

Download: PDF

                                       DATE: 16 April 2019

                   I.T.L. (PRODUCT TESTING) LTD.
                             FCC Radio Test Report
                                                      for

                                       Augmedics Ltd.
                                           Equipment under test:

                                           Radio Module

                             Jeston TX2 assembly PN YELC0050


                              Tested by:   ____________________________
                                              M. Zohar

                           Approved by: _____________________________
                                           D. Shidlowsky




        This report must not be reproduced, except in full, without the written
                     permission of I.T.L. (Product Testing) Ltd.
                       This report relates only to items tested.




Test Report E194320.02                             Augmedics Ltd.         Page 1 of 22
FCC ACC M Ver 1.2 28 February 2011


                                     Measurement/Technical Report for
                                            Augmedics Ltd.
                                             Radio Module


                                Jeston TX2 assembly PN YELC0050

                                       FCC ID: 2AR2O-VOB-P3310


                This report concerns:             Original Grant:
                                                  Class I Change:
                                                  Class II Change:     X

                Equipment type:             FCC: DTS Part 15 Digital Transmission System
                Transmitter

                Limits used:                47CFR15 Section 15.247

                Measurement procedures used are FCC Public Notice DA-00-705 and
                ANSI C63.10: 2013.

                Application for Certification            Applicant for this device:
                prepared by:                             (different from "prepared by")
                    R. Pinchuck                          Stuart Wolf
                    ITL (Product Testing) Ltd.           1 Htzmicha St
                    1 Bat Sheva Street                   Yokneam, Israel 20692
                    Lod 7116002                          Tel: +972-54-999-7738
                    Israel                               Email: stuart@augmedics.com
                    e-mail Rpinchuck@itlglobal.org




Test Report E194320.02                            Augmedics Ltd.              Page 2 of 22
FCC ACC M Ver 1.2 28 February 2011


                                              TABLE OF CONTENTS
         1.       GENERAL INFORMATION ------------------------------------------------------------------------------- 4
                     1.1 Administrative Information ................................................................................. 4
                     1.2 List of Accreditations ......................................................................................... 5
                     1.3 Product Description ........................................................................................... 6
                     1.4 Test Methodology .............................................................................................. 6
                     1.5 Test Facility ....................................................................................................... 6
                     1.6 Measurement Uncertainty ................................................................................. 6
         2.       SYSTEM TEST CONFIGURATION --------------------------------------------------------------------- 7
                     2.1 Justification ........................................................................................................ 7
                     2.2 EUT Exercise Software ..................................................................................... 7
                     2.3 Special Accessories .......................................................................................... 7
                     2.4 Equipment Modifications ................................................................................... 7
                     2.5 Configuration of Tested System ........................................................................ 7
         3.       CONDUCTED & RADIATED MEASUREMENT TEST SET-UP PHOTOS ------------------- 8
         4.       OCCUPIED BANDWIDTH -------------------------------------------------------------------------------10
                     4.1 Test Specification ............................................................................................ 10
                     4.2 Test Procedure ................................................................................................ 10
                     4.3 Test Limit ......................................................................................................... 10
                     4.4 Test Results..................................................................................................... 10
                     4.5 Test Equipment Used, Occupied Bandwidth................................................... 10
         5.       PEAK OUTPUT POWER ---------------------------------------------------------------------------------11
                     5.1 Test Specification ............................................................................................ 11
                     5.2 Test Procedure ................................................................................................ 11
                     5.3 Test Limit ......................................................................................................... 11
                     5.4 Test Results..................................................................................................... 11
                     5.5 Test Equipment Used, Radiated Maximum Power Output ............................. 11
         6.       SPURIOUS RADIATED EMISSIONS -----------------------------------------------------------------12
                     6.1 Test Specification ............................................................................................ 12
                     6.2 Test Procedure ................................................................................................ 12
                     6.3 Test Limit ......................................................................................................... 13
                     6.4 Test Results..................................................................................................... 13
                     6.5 Test Equipment Used, Spurious Radiated Emissions ................................... 15
         7.       APPENDIX A - CORRECTION FACTORS ----------------------------------------------------------16
                     7.1 Correction factors for RF OATS Cable 35m ITL #1879 ................................. 16
                     7.2 Correction factor for RF CABLE for Semi Anechoic Chamber........................ 17
                     7.3 Correction factors for Active Loop Antenna .................................................... 18
                     7.4 Correction factors for biconical antenna – ITL # 1356 .................................... 19
                     7.5 Correction factors for log periodic antenna – ITL # 1349 ................................ 20
                     7.6 Correction factors for Double –Ridged Waveguide Horn ANTENNA............. 21
                     7.7 Correction factors for Horn Antenna .............................................................. 22




Test Report E194320.02                                              Augmedics Ltd.                                 Page 3 of 22
FCC ACC M Ver 1.2 28 February 2011


                               1.    General Information
  1.1           Administrative Information
             Manufacturer:                       Augmedics Ltd.

             Manufacturer's Address:             1 Htzmicha St.
                                                 Yokneam, 20692, Israel
                                                 Tel: +972-54-999-7738



             Manufacturer's Representative:      Stuart Wolf

             Equipment Under Test (E.U.T):       Radio Module



             Equipment Model No.:                Jeston TX2 assembly PN
                                                 YELC0050


             Equipment Serial No.:               Not designated

             Date of Receipt of E.U.T:           26.12.2018


             Start of Test:                      26.12.2018

             End of Test:                        07.01.2019

             Test Laboratory Location:           I.T.L (Product Testing) Ltd.
                                                 1 Batsheva St.,
                                                 Lod
                                                 ISRAEL 7120101

             Test Specifications:                47CFR15 Section 15.247




Test Report E194320.02                        Augmedics Ltd.              Page 4 of 22
FCC ACC M Ver 1.2 28 February 2011


  1.2     List of Accreditations
 The EMC laboratory of I.T.L. is accredited by the following bodies:
       1. The American Association for Laboratory Accreditation (A2LA)
           (U.S.A.), Certificate No. 1152.01.
       2. The Federal Communications Commission (FCC) (U.S.A.),
           FCC Designation No. IL1005.
       3. The Israel Ministry of the Environment (Israel),
           Registration No. 1104/01.
       4. Industry Canada (Canada), IC File No.: 46405-4025;
           Site Nos. IC 4025A-1, IC 4025A-2.




I.T.L. Product Testing Ltd. is accredited by the American Association for Laboratory Accreditation
(A2LA) and the results shown in this test report have been determined in accordance with I.T.L.'s
terms of accreditation unless stated otherwise in the report.




 Test Report E194320.02                           Augmedics Ltd.                   Page 5 of 22
 FCC ACC M Ver 1.2 28 February 2011


  1.3           Product Description
                Radio module

  1.4           Test Methodology
                Radiated testing was performed according to the procedures in FCC Public
                Notice DA 00-705 and ANSI C63.10: 2013. Radiated testing was performed at
                an antenna to EUT distance of 3 meters.

  1.5           Test Facility
                Emissions tests were performed at I.T.L.’s testing facility in Lod, Israel. I.T.L.’s
                EMC Laboratory is accredited by A2LA, certificate No. 1152.01 and its FCC
                Designation Number is IL1005.

  1.6           Measurement Uncertainty
                Conducted Emission
                Conducted Emission (CISPR 11, EN 55011, CISPR 22, EN 55022, ANSI C63.4)
                0.15 – 30 MHz:
                Expanded Uncertainty (95% Confidence, K=2):
                ± 3.6 dB

                Radiated Emission
                Radiated Emission (CISPR 11, EN 55011, CISPR 22, EN 55022, ANSI C63.4)
                for open site:
                30-1000MHz:
                Expanded Uncertainty (95% Confidence, K=2):
                ± 4.96 dB

                1 GHz to 6 GHz
                Expanded Uncertainty (95% Confidence, K=2):
                ±5.19 dB

                >6 GHz
                Expanded Uncertainty (95% Confidence, K=2):
                ±5.51 dB




Test Report E194320.02                              Augmedics Ltd.                 Page 6 of 22
FCC ACC M Ver 1.2 28 February 2011


                     2.          System Test Configuration
  2.1           Justification
           1.    An FCC ID Change Grant was issued to Augmedics LTD for the E.U.T. on
                 03/11/2019 under FCC ID: 2AR2O-VOB-P3310.
           2.    Augmedics LTD will be inserting the certified module in the headset of its own
                 product the “xvision-spine (XVS) system” and requests the following C2PC
                 changes.
           3.    The device will be body worn with a 4cm separation distance of the antenna
                 from the user.
           4.    Additionally, only the DTS – Wifi/g protocol of the module will be
                 operational. Via software the following transmissions will be non-operational:
                 DTS – BLE, DSS and NII.
           5.    The following C2PC testing has been performed: Occupied Bandwidth, Peak
                 Output Power and Spurious Radiated Emissions.
           6.    The E.U.T. met the requirements of a C2PC.
           7.    The E.U.T was tested using the IEEE 802.11/g standard protocol (2.4GHz
                 band, 20MHz BW, SISO) and was transmitting at the low channel (2412MHz),
                 the mid channel (2437MHz) and the high channel (2462MHz).
           8.    Conducted emission method performed while connected to a spectrum
                 analyzer via a 40dB attenuator.

  2.2           EUT Exercise Software
                No special exercise software was used.
  2.3           Special Accessories
                No special accessories were needed in order to achieve compliance.
  2.4           Equipment Modifications
                No modifications were needed in order to achieve compliance.

  2.5           Configuration of Tested System



                                                            E.U.T


                               Figure 1. Configuration of Tested System, Radiated



                                                     40 dB            Spectrum
                                       EUT         Attenuator         Analyzer




                             Figure 2. Configuration of Tested System, Conducted




Test Report E194320.02                                   Augmedics Ltd.             Page 7 of 22
FCC ACC M Ver 1.2 28 February 2011


 3.         Conducted & Radiated Measurement Test
                        Set-Up Photos




                                        Figure 3. Conducted Test Set Up




                                     Figure 4. Radiated Emission Test Setup



Test Report E194320.02                                 Augmedics Ltd.         Page 8 of 22
FCC ACC M Ver 1.2 28 February 2011


                                     Figure 5. Radiated Emission Test Setup




Test Report E194320.02                                 Augmedics Ltd.         Page 9 of 22
FCC ACC M Ver 1.2 28 February 2011


                                         4.         Occupied Bandwidth
               4.1          Test Specification
                            F.C.C. Part 15, Subpart C, Section 2.1048

               4.2          Test Procedure
                            (Temperature (22°C)/ Humidity (48%RH))
                            The E.U.T operation mode and test set-up are as described in Section 2 of this
                            report. The E.U.T. antenna terminal was connected to the Spectrum Analyzer
                            through an external attenuator and an appropriate coaxial cable. The spectrum
                            analyzer was set to the following parameters:
                            Span = ~ 1.5 to 5 times the OBW
                            RBW was between 1% to 5% of the OBW.
                            Detector Function: Peak, Trace: Maximum Hold.

               4.3          Test Limit
                            N/A

              4.4           Test Results

                                                                  Operation          Bandwidth
                                                 Technique
                                                                  Frequency           Reading
                                                  (b/g/n)           (MHz)              (MHz)
                                                                     2412.0             16.8
                                                     g               2437.0             17.0
                                                                     2462.0             17.0

                                                             Figure 6 Test Results


                       JUDGEMENT:                              Passed


               4.5          Test Equipment Used, Occupied Bandwidth

                                                                                         Last Calibration     Next Calibration
  Instrument             Manufacturer                    Model          Serial No.
                                                                                               Date                 Due

40dB Attenuator        Weinschel                     WA 39-40-33 A1323                   December 24, 2018   December 31, 2019

Spectrum
                       Rohde & Schwarz FSL6                          100194              February 19, 2018   February 19, 2019
Analyzer

RF Cable               Huber Suner                   Sucofelex       27502/4PEA          December 24, 2018   December 31, 2019
                                                         Figure 7 Test Equipment Used




            Test Report E194320.02                                      Augmedics Ltd.                Page 10 of 22
            FCC ACC M Ver 1.2 28 February 2011


                                        5.       Peak Output Power
           5.1        Test Specification
                   F.C.C. Part 15, Subpart C, Section 15.247(b)(1)

           5.2        Test Procedure
                   (Temperature (22°C)/ Humidity (48%RH))
                   The E.U.T operation mode and test set-up are as described in Section 2 of this
                   report. The E.U.T. antenna terminal was connected to the Spectrum Analyzer
                   through an external attenuator and an appropriate coaxial cable.

           5.3        Test Limit
                   The maximum peak conducted output power of the intentional radiator shall not
                   exceed the following: For frequency hopping systems operating in the 2400-2483.5
                   MHz band employing at least 75 non-overlapping hopping channels: 1 watt. For all
                   other frequency hopping systems in the 2400-2483.5 MHz band: 0.125 watts. (The
                   limits above applies to antenna gain until 6dBi).

           5.4       Test Results
                   JUDGEMENT:                              Passed by 973.7 mW

              Modulation                     Operation       Power         Power            Limit         Margin
                                             Frequency
                  (b/g/n)                      (MHz)         (dBm)          (mW)           (mW)            (mW)
                                               2412.0         13.4          21.88          1000.0         -978.12
                       g                       2437.0         14.2          26.30          1000.0         -973.70
                                               2462.0         12.3          16.98          1000.0         -983.02
                                             Figure 8 Radiated Power Output Test Results



           5.5          Test Equipment Used, Radiated Maximum Power Output

                                                                        Serial       Last Calibration       Next Calibration
   Instrument                 Manufacturer                Model
                                                                         No.               Date                   Due
                                                        WA 39-40-
40dB Attenuator             Weinschel                                  A1323         December 24, 2018     December 31, 2019
                                                        33

Spectrum Analyzer           Rohde & Schwarz FSL6                       100194        February 19, 2018     February 19, 2019
                                                                       27502/4
RF Cable                    Huber Suner                 Sucofelex                    December 24, 2018     December 31, 2019
                                                                       PEA

                                                   Figure 9 Test Equipment Used


        Test Report E194320.02                                      Augmedics Ltd.                  Page 11 of 22
        FCC ACC M Ver 1.2 28 February 2011


                 6.          Spurious Radiated Emissions
  6.1        Test Specification
           FCC, Part 15, Subpart C, Sections 247(d), 15.205, 15.209

  6.2         Test Procedure
           (Temperature (19°C)/ Humidity (57%RH))
           For measurements between 0.009MHz-30MHz:
           The E.U.T was tested inside the shielded room at a distance of 3 meters and the
           E.U.T was placed on a non-metallic table, 0.8 meters above the ground. The
           frequency range 0.009MHz-30MHz was scanned. The readings were maximized by
           the turntable azimuth between 0-360°, and the antenna polarization.
           The emissions were measured at a distance of 3 meters.
           For measurements between 30.0MHz-1.0GHz:
           A preliminary measurement to characterize the E.U.T was performed inside the
           shielded room at a distance of 3 meters, using peak detection mode and broadband
           antennas. The preliminary measurements produced a list of the highest emissions.
           The E.U.T was then transferred to the open site, and placed on a remote-controlled
           turntable. The E.U.T was placed on a non-metallic table, 0.8 meters above the
           ground. The frequency range 30.0MHz -1.0GHz was scanned and the list of the
           highest emissions was verified and updated accordingly.
           The readings were maximized by adjusting the antenna height between 1-4 meters,
           the turntable azimuth between 0-360°, and the antenna polarization.
           The emissions were measured at a distance of 3 meters.
           For measurements between 1.0GHz-25.0GHz:
           The E.U.T was tested inside the shielded room at a distance of 3 meters and the
           E.U.T was placed on a non-metallic table, 1.5 meters above the ground. The
           frequency range 1.0GHz -25.0GHz was scanned. The readings were maximized by
           the turntable azimuth between 0-360°, and the antenna polarization.
           The emissions were measured at a distance of 3 meters.

           The levels of the emissions within the frequency ranges of the restricted bands
           (Section 15.205 of FCC Part 15) were compared to the limits of the table in Section
           15.209 (a), General Requirements.




Test Report E194320.02                          Augmedics Ltd.                Page 12 of 22
FCC ACC M Ver 1.2 28 February 2011


  6.3        Test Limit
           Radiated emissions which fall in the restricted bands, as defined in §15.205(a),
           must also comply with the radiated emission limits specified in §15.209(a) (see
           §15.205(c)).

               Frequency               Field strength          Measurement       Field strength*     Field strength*
                 (MHz)               (microvolts/meter)      distance (meters)     (dBµV/m)          (dBµV/m)@3m
               0.009-0.490              2400/F(kHz)                300              48.5-13.8            128.5-73.8
               0.490-1.705             24000/F(kHz)                 30              33.8-23.0            73.8-63.0
                1.705-30.0                  30                      30                29.5                   69.5
                   30-88                    100                     3                 40.0                   40.0
                  88-216                    150                     3                 43.5                   43.5
                 216-960                    200                     3                 46.0                   46.0
                Above 960                   500                     3                 54.0                   54.0
           *The emission limits shown in the above table are based on measurements employing a CISPR
           quasi-peak detector except for the frequency bands 9-90 kHz, 110-490 kHz and above 1000 MHz.
           Radiated emission limits in these three bands are based on measurements employing an average
           detector. For average radiated emission measurements above 1000 MHz, there is also a limit
           corresponding to 20 dB above the indicated values in the table is specified when measuring with
           peak detector function.

  6.4         Test Results
           JUDGEMENT:                    Passed
           The EUT met the requirements of the F.C.C. Part 15, Subpart C 209 specification.
           For additional information see Figure 10.




Test Report E194320.02                                    Augmedics Ltd.                 Page 13 of 22
FCC ACC M Ver 1.2 28 February 2011


                                  Spurious Radiated Emission
       Specification: FCC, Part 15, Subpart C Sections 15.209, 15.205, 15.247(d)

Antenna Polarization: Horizontal/Vertical                   Frequency range: 9 kHz to 25.0 GHz
Protocol type: ‘g’                                          Detectors: Peak/AVG



                  Operation                               Peak            Peak     Peak
                                       Freq.     Pol
                  Frequency                              Reading          Limit   Margin

                      (MHz)            (MHz)    (H/V)   (dBµV/m)      (dBµV/m)      (dB)
                                       2428.0     V        45.3          74.0      -28.7
                      2412.0
                                       2428.0    H         37.1           74.0     -36.9
                                       4874.0    V         49.5           74.0     -24.5
                      2437.0
                                       4874.0    H         40.8           74.0     -33.2
                                       4924.0    V         44.8           74.0     -29.2
                      2462.0
                                       4924.0    H         44.1           74.0     -29.9



                  Operation                               Avg.            Avg.     Avg.
                                       Freq.     Pol
                  Frequency                              Reading          Limit   Margin

                      (MHz)            (MHz)    (H/V)   (dBµV/m)      (dBµV/m)      (dB)
                                       4824.0     V        38.6          54.0      -15.4
                      2412.0
                                       4824.0    H         33.0           54.0     -21.0
                                       4874.0    V         42.9           54.0     -11.1
                      2437.0
                                       4874.0    H         37.8           54.0     -16.2
                                       4924.0    V         37.2           54.0     -16.8
                      2462.0
                                       4924.0    H         37.3           54.0     -16.7
                                        Figure 10. Radiated Emission Results
      Margin refers to the test results obtained minus specified requirement; thus a positive number
      indicates failure, and a negative result indicates that the product passes the test.
      “Peak Amp” includes correction factor.
      * “Correction Factor” = Antenna Factor + Cable Loss- Low Noise Amplifier Gain




  Test Report E194320.02                                 Augmedics Ltd.              Page 14 of 22
  FCC ACC M Ver 1.2 28 February 2011


              6.5           Test Equipment Used, Spurious Radiated Emissions
                                                                                        Last Calibration       Next Calibration
 Instrument            Manufacturer                    Model       Serial Number
                                                                                              Date                   Due
EMI Receiver           R&S                       ESCI7             100724               February 19, 2018      February 19, 2019
Spectrum
                       HP                        8592L             3826A01204           February 19, 2018      February 19, 2019
Analyzer

EMI Receiver           HP                        8542E             3906A00276           February 19, 2018      February 19, 2019

RF Filter                                        85420E            3705A00248           February 19, 2018
                       HP                                                                                      February 19, 2019
section

Horn Antenna           ETS                       3115              29845                May 31, 2018           May 31, 2021
Log Periodic
                       EMCO                      3146              9505-4081            May 31, 2018           May 31, 2019
Antenna
Biconical Log
                       EMCO                      3110B             9912-3337            May 15, 2017           May 15, 2019
Antenna
Active Loop
                       EMCO                      6502              9506-2950            October 19, 2017       October 19, 2019
Antenna

Horn Antenna           ARA                       SWH-28            1007                 December 13, 2017      December 31, 2020

Low Noise              DBS                       LNA-DBS-
                                                                   013                  December 24, 2018      December 31, 2019
Amplifier              MICROWAVE                 0411N313
Low Noise
                       Sophia Wireless           LNA 28-B          232                  December 24, 2018      December 31, 2019
Amplifier

RF Cable               Commscope ORS 0623 WBC-400                  G020132-             December 24, 2018      December 31, 2019

RF Cable               Huber Suner               Sucofelex        27502/4PEA            December 24, 2018      December 31, 2019

Semi Anechoic                                                                                                  NCR
                       ETS                       S81               SL 11643             NCR
Civil Chamber
Antenna Mast           ETS                       2070-2            9608-1497            NCR                    NCR

Turntable              ETS                       2087              -                    NCR                    NCR

Mast & Table
                       ETS/EMCO                  2090              9608-1456            NCR                    NCR
Controller

                                                       Figure 11 Test Equipment Used




            Test Report E194320.02                                     Augmedics Ltd.                  Page 15 of 22
            FCC ACC M Ver 1.2 28 February 2011


    7.         APPENDIX A - CORRECTION FACTORS
  7.1 Correction factors for                     RF OATS Cable 35m ITL #1879

                                     Frequency    Cable loss
                                     (MHz)        (dB)
                                     30.0         1.1

                                     50.0         1.1

                                     100.0        1.7

                                     150.0        2.1

                                     200.0        2.5

                                     250.0        2.7

                                     300.0        2.9

                                     350.0        3.1

                                     400.0        3.5

                                     450.0        3.7

                                     500.0        3.9

                                     550.0        4.0

                                     600.0        4.2

                                     650.0        4.4

                                     700.0        4.9

                                     750.0        5.0

                                     800.0        5.0

                                     850.0        4.9

                                     900.0        5.0

                                     950.0        5.1

                                     1000.0       5.4




Test Report E194320.02                        Augmedics Ltd.         Page 16 of 22
FCC ACC M Ver 1.2 28 February 2011


  7.2           Correction factor for RF CABLE for Semi Anechoic Chamber
                ITL # 1841
                                               FREQ       LOSS
                                               (MHz)      (dB)
                                               1000.0     1.5

                                               2000.0     2.1

                                               3000.0     2.7

                                               4000.0     3.1

                                               5000.0     3.5

                                               6000.0     4.1

                                               7000.0     4.6

                                               8000.0     4.9

                                               9000.0     5.7

                                               10000.0    5.7

                                               11000.0    6.1

                                               12000.0    6.1

                                               13000.0    6.2

                                               14000.0    6.7

                                               15000.0    7.4

                                               16000.0    7.5

                                               17000.0    7.9

                                               18000.0    8.1

                                               19000.0    8.8

                                               20000.0    9.1

                                NOTES:
                                1. The cable is manufactured by Commscope
                                2. The cable type is 0623 WBC-400, serial # G020132 and
                                   10m long




Test Report E194320.02                                   Augmedics Ltd.           Page 17 of 22
FCC ACC M Ver 1.2 28 February 2011


  7.3           Correction factors for Active Loop Antenna
                                     Model 6502 S/N 9506-2950
                                     ITL # 1075:
                 f(MHz)                 MAF(dBs/m)           AF(dB/m)
                   0.01                   -33.1                18.4
                   0.02                   -37.2                14.3
                   0.03                   -38.2                13.3
                   0.05                   -39.8                11.7
                    0.1                   -40.1                11.4
                    0.2                   -40.3                11.2
                    0.3                   -40.3                11.2
                    0.5                   -40.3                11.2
                    0.7                   -40.3                11.2
                     1                    -40.1                11.4
                     2                     -40                 11.5
                     3                     -40                 11.5
                     4                    -40.1                11.4
                     5                    -40.2                11.3
                     6                    -40.4                11.1
                     7                    -40.4                11.1
                     8                    -40.4                11.1
                     9                    -40.5                 11
                    10                    -40.5                 11
                    20                    -41.5                 10
                    30                    -43.5                  8




Test Report E194320.02                      Augmedics Ltd.      Page 18 of 22
FCC ACC M Ver 1.2 28 February 2011


  7.4           Correction factors for biconical antenna – ITL # 1356
                                       Model:       EMCO 3110B
                                       Serial No.:9912-3337
                                     Frequency   ITL 1356 AF
                                     [MHz]       [dB/m]
                                     30          13.00
                                     35          10.89
                                     40          10.59
                                     45          10.63
                                     50          10.12
                                     60          9.26
                                     70          7.74
                                     80          6.63
                                     90          8.23
                                     100         11.12
                                     120         13.16
                                     140         13.07
                                     160         14.80
                                     180         16.95
                                     200         17.17




Test Report E194320.02                              Augmedics Ltd.      Page 19 of 22
FCC ACC M Ver 1.2 28 February 2011


             7.5           Correction factors for log periodic antenna – ITL # 1349
                                            Model:       EMCO 3146
                                            Serial No.:9505-4081
                                      Frequency    ITL 1349 AF
                                      [MHz]        [dB/m]
                                      200          11.58
                                      250          12.04
                                      300          14.76
                                      400          15.55
                                      500          17.85
                                      600          18.66
                                      700          20.87
                                      800          21.15
                                      900          22.32
                                      1000         24.22




Test Report E194320.02                            Augmedics Ltd.           Page 20 of 22
FCC ACC M Ver 1.2 28 February 2011


             7.6           Correction factors for Double –Ridged Waveguide
                           Horn ANTENNA
                                                   Model: 3115
                                                   Serial number:29845
                                                   3 meter range; ITL # 1352


                          FREQUENCY      AFE      FREQUENCY         AFE
                                (GHz)   (dB/m)        (GHz)        (dB/m)
                                 0.75      25          9.5            38
                                 1.0      23.5         10.0          38.5
                                 1.5      26.0         10.5          38.5
                                 2.0      29.0         11.0          38.5
                                 2.5      27.5         11.5          38.5
                                 3.0      30.0         12.0          38.0
                                 3.5      31.5         12.5          38.5
                                 4.0      32.5         13.0          40.0
                                 4.5      32.5         13.5          41.0
                                 5.0      33.0         14.0          40.0
                                 5.5      35.0         14.5          39.0
                                 6.0      36.5         15.0          38.0
                                 6.5      36.5         15.5          37.5
                                 7.0      37.5         16.0          37.5
                                 7.5      37.5         16.5          39.0
                                 8.0      37.5         17.0          40.0
                                 8.5      38.0         17.5          42.0
                                 9.0      37.5         18.0          42.5




Test Report E194320.02                           Augmedics Ltd.                Page 21 of 22
FCC ACC M Ver 1.2 28 February 2011


  7.7           Correction factors for   Horn Antenna
                                               Model: SWH-28
                                               at 3 meter range.
                                               ITL #:1353




Test Report E194320.02                   Augmedics Ltd.            Page 22 of 22
FCC ACC M Ver 1.2 28 February 2011



Document Created: 2019-04-17 05:12:12
Document Modified: 2019-04-17 05:12:12

© 2019 FCC.report