test report

FCC ID: 2AQZU-18007

Test Report

Download: PDF
FCCID_4481374

I#]
       TEST                                                                                 Model: TR326A




                                   FCC Part 15C
                 Measurement and Test Report
                                               For

                        Satellite Electronic(Zhong shan)Ltd.

   No.8, Chuang Ye Road, Torch Development Zone, Zhongshan, Guangdong,

                                             China.



                                FCC ID: 2AQZU—18007


 FCC Rule(s):                         FCC Part 15.231

 Product Description:                 CEILING FAN REMOTE CONTROLLER

 Tested Model:                       TR326A

 Report No.:                          WTG19X09066654W

 Sample Receipt Date:                 2019—09—24

 Tested Date:                         2019—09—24 to 2019—09—26

 Issued Date:                         2019—09—26

                                                                      Jack Huang
 Tested By:                          Jack Huang / Engineer

                                                                       *"~~*~
                                                                                  "',‘fl;   _
                                                                       . I-_r 1

 Reviewed By:                         Silin Chen / EMC Manager

 Approved & Authorized By:           Jandy So / PSQ Manager            J"‘%‘”
 Prepared By:
                        Shenzhen SEM Test Technology Co., Ltd.
                      1/F, Building A, Hongwei Industrial Park, Liuxian 2nd Road,
                      Bao‘an District, Shenzhen, P.R.C. (518101)
          Tel.: +86—755—33663308   Fax.: +86—755—33663309     Website: www.semtest.com.cn


   Note: This test report is limited to the above client company and the product model only. It
   may not be duplicated without prior permitted by Shenzhen SEM Test Technology Co., Ltd.


Report No.: WTG19X09066634W                    Page 1 of 18                                 RF Part 15.231a


                                                                                                                                                    Model: TR326A



TABLE OF CONTENTS
1. GENERAL INFORMATION ...................................................................................................................................4
   1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ...............................................................................4
   1.2 TEST STANDARDS...................................................................................................................................................5
   1.3 TEST METHODOLOGY .............................................................................................................................................5
   1.4 TEST FACILITY .......................................................................................................................................................5
   1.5 EUT SETUP AND TEST MODE .................................................................................................................................6
   1.6 MEASUREMENT UNCERTAINTY ..............................................................................................................................6
   1.7 TEST EQUIPMENT LIST AND DETAILS .....................................................................................................................7
2. SUMMARY OF TEST RESULTS ...........................................................................................................................8
3. ANTENNA REQUIREMENT ..................................................................................................................................9
   3.1 STANDARD APPLICABLE.........................................................................................................................................9
   3.2 TEST RESULT..........................................................................................................................................................9
4. RADIATED EMISSIONS .......................................................................................................................................10
   4.1 STANDARD APPLICABLE.......................................................................................................................................10
   4.2 TEST PROCEDURE .................................................................................................................................................11
   4.3 CORRECTED AMPLITUDE & MARGIN CALCULATION ............................................................................................12
   4.4 SUMMARY OF TEST RESULTS/PLOTS ....................................................................................................................12
5. 20DB BANDWIDTH ...............................................................................................................................................15
   5.1 STANDARD APPLICABLE.......................................................................................................................................15
   5.1 TEST PROCEDURE .................................................................................................................................................15
   5.2 SUMMARY OF TEST RESULTS/PLOTS ....................................................................................................................15
6. TRANSMISSION TIME .........................................................................................................................................16
   6.1 STANDARD APPLICABLE.......................................................................................................................................16
   6.2 TEST PROCEDURE .................................................................................................................................................16
   6.3 SUMMARY OF TEST RESULTS/PLOTS ....................................................................................................................16
7. DUTY CYCLE .........................................................................................................................................................17
   7.1 STANDARD APPLICABLE.......................................................................................................................................17
   7.2 TEST PROCEDURE .................................................................................................................................................17
   7.3 SUMMARY OF TEST RESULTS/PLOTS ....................................................................................................................17




Report No.: WTG19X09066654W                                                        Page 2 of 18                                                      RF Part 15.231a


                                                                  Model: TR326A


Report version
  Version No.        Date of issue                  Description

     Rev.00           2019-09-26                     Original

        /                     /                          /




Report No.: WTG19X09066654W          Page 3 of 18                 RF Part 15.231a


                                                                                         Model: TR326A


1. GENERAL INFORMATION

1.1 Product Description for Equipment Under Test (EUT)

Client Information
Applicant:                              Satellite Electronic(Zhong shan)Ltd.
Address of applicant:                   No.8, Chuang Ye Road, Torch Development Zone, Zhongshan,
                                        Guangdong, China.

Manufacturer:                           Satellite Electronic(Zhong shan)Ltd.
Address of manufacturer:                No.8, Chuang Ye Road, Torch Development Zone, Zhongshan,
                                        Guangdong, China.

General Description of EUT
Product Name:                             CEILING FAN REMOTE CONTROLLER
Trade Name:                               /
Model No.:                                TR326A
Adding Model(s):                          /
Rated Voltage:                            DC 3V
Power Adaptor :                           /
Software Version:                         /
Hardware Version:                         /

Note: The test data is gathered from a production sample provided by the manufacturer.


Technical Characteristics of EUT
Frequency Range:                          304.25MHz
Max. Field Strength:                      77.09dBuV/m(3m)
Modulation:                               ASK
Antenna Type:                             PCB Antenna
Antenna Gain:                             0dBi




Report No.: WTG19X09066654W                          Page 4 of 18                        RF Part 15.231a


I#]
         TEST                                                                                Model: TR326A




1.2 Test Standards
The tests were performed according to following standards:


ECC Rules Part 15.231; Periodic operation in the band 40.66—40.70 MHz and above 70 MHz.
ANSI C€63.10—2013: American National Standard for Testing Unlicensed Wireless Devices

Maintenance of compliance is the responsibility of the manufacturer. Any modification of the product, which
result in lowering the emission/immunity, should be checked to ensure compliance has been maintained.

1.3 Test Methodology

All measurements contained in this report were conducted with ANSI C€63.10—2013,
The equipment under test (EUT) was configured to measure its highest possible emission level. The test modes
were adapted accordingly in reference to the Operating Instructions.

1.4 Test Facility

Address of the test laboratory
Laboratory: Shenzhen SEM Test Technology Co., Ltd.
Address: 1/F, Building A, Hongwei Industrial Park, Liuxian 2nd Road, Bao‘an District, Shenzhen, PR.C. (518101)


FCC — Registration No.: 125990
Shenzhen SEM Test Technology Co., Ltd. EMC Laboratory has been registered and fully described in a
report filed with the FCC (Federal Communications Commussion). The acceptance letter from the FCC is maintain
ed in our files. The Designation Number is CN5010


Industry Canada (IC) Registration No.: 11464A
The 3m Semi—anechoic chamber of Shenzhen SEM Test Technology Co., Ltd. has been registered by Certification
and Engineering Bureau of Industry Canada for radio equipment testing with Registration No.: 11464A.




Report No.: WTG19X090666M4W                           Page 5 of 18                             RF Part 15.231a


I#]
          TEST                                                                                   Model: TR326A




1.5 EUT Setup and Test Mode

The EUT was operated at continuous transmitting mode that was for the purpose of the measurements. All testing
shall be performed under maximum output power condition, and to measure its highest possible emissions level,
more detailed description as follows:


Test Mode List
 Test Mode                       Description                                      Remark
    TM1                          Transmitting                                     304.25

Test Conditions
                      Temperature:                                               20—21 °C
                    Relative Humidity:                                           50—52 %.
                      ATM Pressure:                                              1019 mbar

EUT Cable List and Details
    Cable Description                    Length (m)        Shielded/Unshielded          With / Without Ferrite
             /                                  /                      /                            /


Special Cable List and Details
    Cable Description                    Length (m)        Shielded/Unshielded          With / Without Ferrite
             /                                  /                      /                            /


Auxiliary Equipment List and Details
        Description                    Manufacturer                  Model                    Serial Number
             /                                  /                      /                            /

1.6 Measurement Uncertainty

Measurement uncertainty
                     Parameter                              Conditions                         Uncertainty
             Occupied Bandwidth                             Conducted                            +1.5%
        Conducted Spurious Emission                         Conducted                           +2.170B
                 Transmission Time                          Conducted                             +5%

             Conducted Emissions                            Conducted                   9—150kHz_+3.74dB
                                                                                       0.15—30MHz +3.34dB
                                                                                        30—200MHz +4.52dB
              ,        ,       20y                               ,                         0.2—1GHz +5.56dB
       Transmitter Spurious Emissions                        Radiated
                                                                                             1—6GHz +3.84dB
                                                                                            6—18GHz +3.92dB




Report No.: WTG19X09066634W                           Page 6 of 18                                RF Part 15.231a


                                                                                             Model: TR326A



1.7 Test Equipment List and Details

    No.        Description     Manufacturer               Model            Serial No.   Cal Date    Due Date
                Spectrum
SEMT-1072                          Agilent                E4407B          MY41440400    2019-04-30 2020-04-29
                Analyzer
                 Spectrum          Rohde &
SEMT-1031                                                 FSP30            836079/035   2019-04-30 2020-04-29
                 Analyzer          Schwarz
                 EMI Test          Rohde &
SEMT-1007                                                 ESVB             825471/005   2019-04-30 2020-04-29
                 Receiver          Schwarz
SEMT-1008        Amplifier         Agilent                8447F           3113A06717    2019-04-30 2020-04-29
SEMT-1043        Amplifier          C&D                 PAP-1G18              2002      2019-04-30 2020-04-29
                Broadband
SEMT-1011                       Schwarz beck            VULB9163            9163-333    2019-05-05 2021-05-04
                 Antenna
SEMT-1042      Horn Antenna          ETS                   3117             00086197    2019-05-05 2021-05-04
SEMT-1069      Loop Antenna     Schwarz beck            FMZB 1516             9773      2019-05-05 2021-05-04
                 EMI Test          Rohde &
SEMT-1001                                                  ESPI              101611     2019-04-30 2020-04-29
                 Receiver          Schwarz
SEMT-1003         L.I.S.N       Schwarz beck            NSLK8126            8126-224    2019-04-30 2020-04-29
SEMT-1166      Power Limiter       Agilent               N9356B           MY45450376    2019-04-30 2020-04-29
SEMT-1048       RF Limiter         ATTEN           AT-BSF-2400~2500                /    2019-04-30 2020-04-29
SEMT-1076       RF Switcher     Top Precision           RCS03-A2                   /    2019-04-30 2020-04-29
SEMT-C001          Cable          Zheng DI        LL142-07-07-10M(A)               /    2019-03-18 2020-03-17
SEMT-C002          Cable          Zheng DI        ZT40-2.92J-2.92J-6M              /    2019-03-18 2020-03-17
SEMT-C003          Cable          Zheng DI        ZT40-2.92J-2.92J-2.5M            /    2019-03-18 2020-03-17
SEMT-C004          Cable          Zheng DI               2M0RFC                    /    2019-03-18 2020-03-17
SEMT-C005          Cable          Zheng DI               1M0RFC                    /    2019-03-18 2020-03-17
SEMT-C006          Cable          Zheng DI               1M0RFC                    /    2019-03-18 2020-03-17
                 Anechoic
SEMT-1087                          SAEMC                 FSAC318                   /    2017-04-28 2020-04-27
                 chamber

                                                   Software List
         Description                       Manufacturer                     Model                Version
      EMI Test Software
                                                Farad                      EZ-EMC               RA-03A1
     (Radiated Emission)*
       EMI Test Software
                                                Farad                      EZ-EMC               RA-03A1
    (Conducted Emission)*


*Remark: indicates software version used in the compliance certification testing




Report No.: WTG19X09066654W                             Page 7 of 18                          RF Part 15.231a


I#]
         TEST                                                Model: TR326A



2. SUMMARY OF TEST RESULTS


          FCC Rules             Description of Test Item        Result
            $ 15.203             Antenna Requirement          Compliant
            §15.205           Restricted Band of Operation    Compliant
            § 15.209          Radiated Spurious Emissions     Compliant
          §15.231(a)              Deactivation Testing        Compliant
          §15.231(b)              Radiated Emissions          Compliant
          §15.231(c)            20dB Bandwidth Testing        Compliant
          § 15.207(a)             Conducted Emission             N/A


N/A: not applicable




Report No.: WTG19X090666M4W        Page 8 of 18              RF Part 15.231a


                                                                                                 Model: TR326A


3. Antenna Requirement

3.1 Standard Applicable

According to FCC Part 15.203, an intentional radiator shall be designed to ensure that no antenna other than that
furnished by the responsible party shall be used with the device. The use of a permanently attached antenna or of
an antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply with the
provisions of this section.

3.2 Test Result

This product has a PCB antenna, fulfill the requirement of this section.




Report No.: WTG19X09066654W                            Page 9 of 18                               RF Part 15.231a


                                                                                               Model: TR326A


4. Radiated Emissions

4.1 Standard Applicable

According to §15.231(b), the field strength of emissions from intentional radiators operated under this section
shall not exceed the following:




The limits on the field strength of the spurious emissions in the above table are based on the fundamental
frequency of the intentional radiator. Spurious emissions shall be attenuated to the average (or, alternatively,
CISPR quasi-peak) limits shown in this table or to the general limits shown in §15.209, whichever limit permits a
higher field strength.

The emission limit in this paragraph is based on measurement instrumentation employing an average detector. The
provisions in §15.35 for limiting peak emissions apply. Spurious Radiated Emissions measurements starting
below or at the lowest crystal frequency.

Compliance with the provisions of §15.205 shall be demonstrated using the measurement instrumentation
specified in that section.




Report No.: WTG19X09066654W                          Page 10 of 18                               RF Part 15.231a


                                                                                        Model: TR326A

4.2 Test Procedure

The setup of EUT is according with per ANSI C63.10-2013 measurement procedure. The specification used was
with the FCC Part 15.205 15.231(b) and FCC Part 15.209 Limit.




                                                         Antenna
                                                          Tower
                                                                       1m-4m




                                   3m

           EUT SYS
                            1.5m




          Turntable
           Table                                                               To EMI Receiver



                                        Ground Plane




Report No.: WTG19X09066654W                            Page 11 of 18                      RF Part 15.231a


                                                                                               Model: TR326A

4.3 Corrected Amplitude & Margin Calculation

The Corrected Amplitude is calculated by adding the Antenna Factor and the Cable Factor, and subtracting the
Amplifier Gain from the Amplitude reading. The basic equation is as follows:

                      Corr. Ampl. = Indicated Reading +Ant.Loss +Cab. Loss – Ampl.Gain

The “Margin” column of the following data tables indicates the degree of compliance with the applicable limit.
For example, a margin of -6dBV means the emission is 6dBV below the maximum limit. The equation for
margin calculation is as follows:
                                  Margin = Corr. Ampl. – FCC Part 15C Limit

4.4 Summary of Test Results/Plots

Note: this EUT was tested in 3 orthogonal positions and the worst case position data was reported.




Report No.: WTG19X09066654W                          Page 12 of 18                               RF Part 15.231a


                                                                                                                   Model: TR326A




                                         TM1                                                                       Horizontal




                                                                                                                   Limitd:




—20.0                                                                         1          1        1           1           1      bo   d
     30.000    40                                                           1I3I]l]      :II]l]   5II]l]     I'I:FI]l]    ilf'l]l] j 1l]lI]l].I] MHz




No.       Frequency   Reading   Corr.     Dutycycle     Result        Limit           Margin      Deg.               Height           Remark

              MHz     dBuV/m    Factor     Factor      dBuV/m     dBuV/m               dB             (° )               (cm)

                                 (dB)       (dB)
 1        304.6099     85.04    —7.95       N/A         77.09         94.95           —17.86          71                 100              Peak
          304.6099       /        /        —5.99        71.1          74.95           —3.85           12                 100              Ave
 2        912.8620     37.19    —0.99       N/A         36.8          74.95           —38.15          32                 100              Peak
          912.8620       /        /        —5.99        30.81         54.95           —24.14          114                100              Ave


Above 1GHz
No.       Frequency   Reading   Corr.     Dutycycle     Result        Limit           Margin      Deg.               Height           Remark

              MHz     dBuV/m    Factor     Factor      dBuV/m     dBuV/m               dB             (° )               (cm)

                                 (dB)       (dB)
 1        1218.4396    60.54    —8.64       N/A          51.9          74             —22.1           88                 150              Peak
          1218.4396      /        /         —5.99       45.91          54             —8.09           88                 150              Ave
 2        1523.0495    61.45    —9.97       N/A         51.48          74             —22.52          88                 150              Peak
          1523.0495      /        /         —5.99       45.49          54             —8.51           88                 150              Ave




Report No.: WTG19X09066634W                           Page 13 of 18                                                      RF Part 15.231a


                                                                                                                               Model: TR326A




              Test Mode                        TM1                                                                              Vertical


80.0      dBu¥/m

                                                                                                                          Limit1 :

70




—20.0                                                                              1           1        1             1          1      1    1
     30.000      40                                                               1I]l]I]     lIll]l]   5Il]l]       I;iI]I]    ilf'I]l] j 1 I]II]l]_l] MHz



 No.          Frequency   Reading    Corr.      Dutycycle     Result        Limit           Margin          Deg.               Height        Remark

                MHz       dBuV/m    Factor{(     Factor      dBuV/m     dBuV/m               (dB)           ( °* )              (ecm)
                                      dB)            (dB)
     1        304.6099     82.18     —7.95        N/A         74.23         94.95           —20.72          114                 100              peak
              304.6099       /         /          —5.99       63.76         74.95           —11.19           21                 100              Ave
     2        903.3094     49.25     —1.14        N/A         48.11         74.95           —26.84           31                 100              peak


Above 1GHz
 No.          Frequency   Reading    Corr.      Dutycycle     Result        Limit           Margin          Deg.               Height        Remark

                MHz       dBuV/m    Factor       Factor      dBuV/m     dBuV/m               dB             (° )                (cm)

                                     (dB)         (dB)
     1        1218.4396    60.32     —8.84        N/A         51.48          74             —22.52          140                 150              Peak
              1218.4396      /         /          —5.99       45.49          54             —8.51           140                 150              Ave
     2        1523.0495    61.55     —9.47        N/A         52.08          74             —21.92          140                 100              Peak
              1523.0495      /         /          —5.99       46.09          54             —7.91           140                 100              Ave


Note: Testing is carried out with frequency rang 30MHz to the tenth harmonics, which above 5 Harmonics are
attenuated more than 20dB below the permissible limits or the field strength is too small to be measured.




Report No.: WTG19X09066634W                                 Page 14 of 18                                                        RF Part 15.231a


                                                                                         Model: TR326A


5. 20dB Bandwidth

5.1 Standard Applicable

According to FCC Part 15.231(c), the bandwidth of the emission shall be no wider than 0.25% of the center
frequency for devices operating above 70 MHz and below 900 MHz. Bandwidth is determined at the points 20 dB
down from the modulated carrier.

5.1 Test Procedure

With the EUT’s antenna attached, the EUT’s 20dB Bandwidth power was received by the test antenna, which was
connected to the spectrum analyzer with the START, and STOP frequencies set to the EUT’s operation band.


5.2 Summary of Test Results/Plots

     Test Frequency                   20dB Bandwidth                   Limit
                                                                                           Result
          MHz                              kHz                         kHz
         304.25                     8.87                   760.625                          Pass
Limit = Fudamental Frequency X 0.25% = 304.25MHz X 0.25% = 760.625 kHz

Please refer to the attached plots.




        304.25MHz




Report No.: WTG19X09066654W                            Page 15 of 18                        RF Part 15.231a


                                                                                                 Model: TR326A


6. Transmission Time

6.1 Standard Applicable

According to FCC Part 15.231(a), the transmitter shall be complied the following requirements:

1) A manually operated transmitter shall employ a switch that will automatically deactivate the transmitter within
not more than 5 seconds of being released.
(2) A transmitter activated automatically shall cease transmission within 5 seconds after activation.
(3) Periodic transmissions at regular predetermined intervals are not permitted. However, polling or supervision
    transmissions, including data, to determine system integrity of transmitters used in security or safety
    applications are allowed if the total duration of transmissions does not exceed more than two seconds per hour
    for each transmitter. There is no limit on the number of individual transmissions, provided the total
    transmission time does not exceed two seconds per hour.

6.2 Test Procedure

With the EUT’s antenna attached, the EUT’s output signal was received by the test antenna, which was connected
to the spectrum analyzer. Set the center frequency to 433.92MHz, than set the spectrum analyzer to Zero Span for
the release time reading. During the testing, the switch was released then the EUT automatically deactivated.

6.3 Summary of Test Results/Plots

 Transmission Type        Test Frequency(MHz)       Transmission Time(s)            Limit(s)            Result
      Manually                        304.25                 0.288                     5                 Pass


Please refer to the attached plots.




        304.25MHz




Report No.: WTG19X09066654W                           Page 16 of 18                               RF Part 15.231a


                                                                                              Model: TR326A


7. Duty Cycle

7.1 Standard Applicable

According to FCC Part 15.231 (b)(2) and 15.35 (c), for pulse operation transmitter, the averaging pulsed
emissions are calculated by peak value of measured emission plus duty cycle factor.

7.2 Test Procedure

With the EUT’s antenna attached, the EUT’s output signal was received by the test antenna, which was connected
to the spectrum analyzer. Set the center frequency to 433.92MHz, than set the spectrum analyzer to Zero Span for
the release time reading. During the testing, the switch was released then the EUT automatically deactivated.

7.3 Summary of Test Results/Plots

433.93MHz:
                           Width of Pulse                               Transmission Time   Total Time (Ton)
    Type of Pulse                                 Quantity of Pulse
                               (ms)                                           (ms)                (ms)
    Pulse 1 (Wide)               0.750                   25                    18.75
                                                                                                  12.55
   Pulse 2 (Narrow)              0.375                   3                     1.13


      Test Period (Tp)              Total Time (Ton)              Duty Cycle            Duty Cycle Factor
             ms                            ms                           %                       dB
            39.60                         19.88                        50.20                   -5.99
Remark: Duty Cycle Factor=20*log(Duty Cycle)

Please refer to the attached test plots




Report No.: WTG19X09066654W                            Page 17 of 18                            RF Part 15.231a


                                                          Model: TR326A



304.25MHz




      Test Period




     Pulse Number




   Pulse 1 and Pulse 2




                              ***** END OF REPORT *****




Report No.: WTG19X09066654W             Page 18 of 18      RF Part 15.231a



Document Created: 2019-10-15 18:00:31
Document Modified: 2019-10-15 18:00:31

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC