test report

FCC ID: 2AQZU-18005

Test Report

Download: PDF
FCCID_4368832

                                                                                       Model:: TR76G




                        FCC
                          C Partt 15C
                 M
                 Measur
                      remen
                          nt and
                               d Test Repoort
                                                For
                        Satellitte Electrronic(Zh
                                                hong Shaan)Ltd.
   No.8, Chuang Ye
                Y Road, Torch Deevelopmen
                                        nt Zone, Zhongsha
                                                 Z      an, Guang
                                                                gdong,

                                               China


                                  FCC ID
                                       D: 2AQZU-180055


       FC
        CC Rule(s):                          FCC Part 15.231
                                                      1

       Pro
         oduct Desc
                  cription:                  CEILING FAN
                                                     F   REMOT
                                                             TE CONTR
                                                                    ROLLER

         sted Model:
       Tes                                   TR76G

       Re
        eport No.:                                 07045028W
                                             WTG19G0       W

       Sample Rece
                 eipt Date:                  2019-07-08
                                                      8

       Tes
         sted Date:                                   9 to 2019-07-17
                                             2019-07-09

       Iss
         sued Date:                          2019-07-17
                                                      7

         sted By:
       Tes                                   Iven Guo / Engineer

        eviewed By
       Re        y:                          Silin Chen / EMC Man
                                                                nager

        pproved & Authorized
       Ap         A        d By:             Jandy So / PSQ Mana
                                                               ager

       Pre
         epared By::
                                 henzhen SE
                                Sh           EM Test Technology Co.,  C Ltd.
                       1/F, Buildin
                                  ng A, Hongw wei Industrial Park, Liu
                                                                     uxian 2nd Road,
                               Baoo'an District, Shenzhen n, P.R.C.(518101)
          Tel.: +86-75
                     55-33663308
                               8 Fax.: +86
                                         6-755-336633
                                                    309 Websitte: www.sem
                                                                        mtest.com.cn


   Note: This
         T    test repport is limite
                                   ed to the abbove client company
                                                           c       an
                                                                    nd the produ
                                                                               uct model only.
                                                                                         o     It
   may noot be dupliccated withou  ut prior perm
                                               mitted by Shhenzhen SE
                                                                    EM.Test Tecchnology Co.,
                                                                                        C Ltd.


Report No.: WTG19G070
            W        45028W                         Page 1 of 19                         RF Part
                                                                                            P 15.231


                                                                                                                                                  Model: TR76G



TABLE OF CONTENTS
1. GENERAL INFORMATION ...................................................................................................................................3
   1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ...............................................................................3
   1.2 TEST STANDARDS...................................................................................................................................................4
   1.3 TEST METHODOLOGY .............................................................................................................................................4
   1.4 TEST FACILITY .......................................................................................................................................................4
   1.5 EUT SETUP AND TEST MODE .................................................................................................................................5
   1.6 MEASUREMENT UNCERTAINTY ..............................................................................................................................5
   1.7 TEST EQUIPMENT LIST AND DETAILS .....................................................................................................................6
2. SUMMARY OF TEST RESULTS ...........................................................................................................................7
3. ANTENNA REQUIREMENT ..................................................................................................................................8
   3.1 STANDARD APPLICABLE.........................................................................................................................................8
   3.2 TEST RESULT..........................................................................................................................................................8
4. CONDUCTED EMISSIONS ....................................................................................................................................9
   4.1 TEST PROCEDURE ...................................................................................................................................................9
   4.2 BASIC TEST SETUP BLOCK DIAGRAM.....................................................................................................................9
   4.3 TEST RECEIVER SETUP ...........................................................................................................................................9
   4.4 SUMMARY OF TEST RESULTS/PLOTS ......................................................................................................................9
5. RADIATED EMISSIONS .......................................................................................................................................10
   5.1 STANDARD APPLICABLE.......................................................................................................................................10
   5.2 TEST PROCEDURE .................................................................................................................................................11
   5.3 CORRECTED AMPLITUDE & MARGIN CALCULATION ............................................................................................12
   5.4 SUMMARY OF TEST RESULTS/PLOTS ....................................................................................................................12
6. 20DB BANDWIDTH ...............................................................................................................................................15
   6.1 STANDARD APPLICABLE.......................................................................................................................................15
   6.1 TEST PROCEDURE .................................................................................................................................................15
   6.2 SUMMARY OF TEST RESULTS/PLOTS ....................................................................................................................15
7. TRANSMISSION TIME .........................................................................................................................................16
   7.1 STANDARD APPLICABLE.......................................................................................................................................16
   7.2 TEST PROCEDURE .................................................................................................................................................16
   7.3 SUMMARY OF TEST RESULTS/PLOTS ....................................................................................................................16
8. DUTY CYCLE .........................................................................................................................................................17
   8.1 STANDARD APPLICABLE.......................................................................................................................................17
   8.2 TEST PROCEDURE .................................................................................................................................................17
   8.3 SUMMARY OF TEST RESULTS/PLOTS ....................................................................................................................17




Report No.: WTG19G07045028W                                                              Page 2 of 19                                                 RF Part 15.231


                                                                                                Model: TR76G


1. GENERAL INFORMATION

1.1 Product Description for Equipment Under Test (EUT)

Client Information
Applicant:                                Satellite Electronic(Zhong Shan)Ltd.
                                          No.8, Chuang Ye Road, Torch Development Zone, Zhongshan,
Address of applicant:
                                          Guangdong, China

Manufacturer:                             Satellite Electronic(Zhong Shan)Ltd.
                                          No.8, Chuang Ye Road, Torch Development Zone, Zhongshan,
Address of manufacturer:
                                          Guangdong, China

General Description of EUT
Product Name:                              CEILING FAN REMOTE CONTROLLER
Trade Name:                                /
Model No.:                                 TR76G
Adding Model(s):                           TR76F
Rated Voltage:                             DC 3V
Software Version:                          N/A
Hardware Version:                          N/A

Note: The test data is gathered from a production sampleprovided by the manufacturer.The appearance of others
models listed in the report is different from main-test model TR76G, but the circuit and the electronic construction
do not change, declared by the manufacturer.


Technical Characteristics of EUT
Frequency Range:                           304.25MHz
Max. Field Strength:                       82.55dBuV/m(3m)
Data Rate:                                 /
Modulation:                                ASK
Antenna Type:                              PCB Antenna
Antenna Gain:                              0dBi
Lowest Internal frequency of EUT:          16MHz




Report No.: WTG19G07045028W                               Page 3 of 19                            RF Part 15.231


                                                                                            Model: TR76G

1.2 Test Standards
The tests were performed according to following standards:

FCC Rules Part 15.231: Periodic operation in the band 40.66-40.70 MHz and above 70 MHz.
ANSI C63.10-2013: American National Standard for Testing Unlicensed Wireless Devices

Maintenance of compliance is the responsibility of the manufacturer. Any modification of the product, which
result in lowering the emission/immunity, should be checked to ensure compliance has been maintained.

1.3 Test Methodology

All measurements contained in this report were conducted with ANSI C63.10-2013,
The equipment under test (EUT) was configured to measure its highest possible emission level. The test modes
were adapted accordingly in reference to the Operating Instructions.

1.4 Test Facility

FCC – Registration No.: 125990
Shenzhen SEM Test Technology Co., Ltd. Laboratory has been recognized to perform compliance testing on
equipment subject to the Commissions Declaration Of Conformity (DOC). The Designation Number is CN5010,
and Test Firm Registration Number is 125990.


Industry Canada (IC) Registration No.: 11464A
The 3m Semi-anechoic chamber of Shenzhen SEM.Test Technology Co., Ltd. has been registered by Certification
and Engineering Bureau of Industry Canada for radio equipment testing with Registration No.: 11464A.




Report No.: WTG19G07045028W                             Page 4 of 19                           RF Part 15.231


                                                                                             Model: TR76G

1.5 EUT Setup and Test Mode

The EUT was operated at continuous transmitting mode that was for the purpose of the measurements. All testing
shall be performed under maximum output power condition, and to measure its highest possible emissions level,
more detailed description as follows:


Test Mode List
 Test Mode                      Description                                    Remark
    TM1                         Transmitting                                304.25MHz
      /                                /                                          /

Test Conditions
                        Temperature:                                           22~25 C
                   Relative humidity                                           50~55 %.
                     ATM Pressure:                                           1019 mbar

EUT Cable List and Details
    Cable Description                      Length (m)    Shielded/Unshielded          With / Without Ferrite



Special Cable List and Details
    Cable Description                      Length (m)    Shielded/Unshielded          With / Without Ferrite



Auxiliary Equipment List and Details
          Description                  Manufacturer             Model                      Serial Number



1.6 Measurement Uncertainty

Measurement uncertainty
                    Parameter                              Conditions                       Uncertainty
               Occupied Bandwidth                          Conducted                          ±1.5%
          Conducted Spurious Emission                      Conducted                         ±2.17dB
                Transmission Time                          Conducted                           ±5%
                                                                                        9-150kHz ±3.74dB
              Conducted Emissions                          Conducted
                                                                                      0.15-30MHz ±3.34dB
                                                                                      30-200MHz ±4.52dB
                                                                                        0.2-1GHz ±5.56dB
          Transmitter Spurious Emissions                    Radiated
                                                                                          1-6GHz ±3.84dB
                                                                                        6-18GHz ±3.92dB




Report No.: WTG19G07045028W                             Page 5 of 19                           RF Part 15.231


                                                                                       Model: TR76G

1.7 Test Equipment List and Details

   No.      Description     Manufacturer            Model             Serial No.   Cal Date    Due Date
             Spectrum
SEMT-1072                       Agilent            E4407B            MY41440400    2019-04-30 2020-04-29
             Analyzer
              Spectrum         Rohde &
SEMT-1031                                           FSP30             836079/035   2019-04-30 2020-04-29
              Analyzer         Schwarz
              EMI Test         Rohde &
SEMT-1007                                           ESVB              825471/005   2019-04-30 2020-04-29
              Receiver         Schwarz
SEMT-1008     Amplifier         Agilent             8447F             3113A06717   2019-04-30 2020-04-29
SEMT-1043     Amplifier          C&D              PAP-1G18               2002      2019-04-30 2020-04-29
             Broadband
SEMT-1011                   Schwarz beck          VULB9163             9163-333    2019-05-05 2021-05-04
              Antenna
SEMT-1042   Horn Antenna         ETS                 3117              00086197    2019-05-05 2021-05-04
SEMT-1121   Horn Antenna      Schwarzbeck         BBHA 9170          BBHA9170582 2019-05-05 2021-05-04
SEMT-1069   Loop Antenna    Schwarz beck          FMZB 1516              9773      2019-05-05 2021-05-04
              EMI Test         Rohde &
SEMT-1001                                            ESPI               101611     2019-04-30 2020-04-29
              Receiver         Schwarz
SEMT-1003      L.I.S.N      Schwarz beck          NSLK8126             8126-224    2019-04-30 2020-04-29
                               Rohde &
SEMT-1002   Pulse Limiter                          ESH3-Z2              100911     2019-04-30 2020-04-29
                               Schwarz
                               Direction
SEMT-1168   Pre-amplifier                          PAP-0126          14141-12838   2019-04-30 2020-04-29
                              Systems Inc.
                               Direction
SEMT-1169   Pre-amplifier                          PAP-2640          14145-14153   2019-04-30 2020-04-29
                              Systems Inc.
              Spectrum         Rohde &
SEMT-1163                                           FSP40               100612     2019-04-30 2020-04-29
              Analyzer         Schwarz
             DRG Horn            A.H.
SEMT-1170                                          SAS-574               571       2019-05-05 2021-05-04
              Antenna         SYSTEMS
SEMT-1166   Power Limiter       Agilent            N9356B            MY45450376    2019-04-30 2020-04-29
SEMT-1048    RF Limiter         ATTEN         AT-BSF-2400~2500            /        2019-04-30 2020-04-29
SEMT-1076    RF Switcher    Top Precision         RCS03-A2                /        2019-04-30 2020-04-29
SEMT-C001      Cable           Zheng DI      LL142-07-07-10M(A)           /        2019-03-18 2020-03-17
SEMT-C002      Cable           Zheng DI      ZT40-2.92J-2.92J-6M          /        2019-03-18 2020-03-17
SEMT-C003      Cable           Zheng DI      ZT40-2.92J-2.92J-2.5M        /        2019-03-18 2020-03-17
SEMT-C004      Cable           Zheng DI            2M0RFC                 /        2019-03-18 2020-03-17
SEMT-C005      Cable           Zheng DI            1M0RFC                 /        2019-03-18 2020-03-17
SEMT-C006      Cable           Zheng DI            1M0RFC                 /        2019-03-18 2020-03-17




Report No.: WTG19G07045028W                          Page 6 of 19                        RF Part 15.231


                                                             Model: TR76G


2. SUMMARY OF TEST RESULTS


        FCC Rules               Description of Test Item         Result
         §15.203                 Antenna Requirement           Compliant
          §15.205             Restricted Band of Operation     Compliant
        §15.207(a)                Conducted Emission              N/A
         §15.209              Radiated Spurious Emissions      Compliant
         §15.231(a)               Deactivation Testing         Compliant
        §15.231(b)                Radiated Emissions           Compliant
         §15.231(c)             20dB Bandwidth Testing         Compliant




Report No.: WTG19G07045028W            Page 7 of 19            RF Part 15.231


                                                                                                Model: TR76G


3. Antenna Requirement

3.1 Standard Applicable

According to FCC Part 15.203, an intentional radiator shall be designed to ensure that no antenna other than that
furnished by the responsible party shall be used with the device. The use of a permanently attached antenna or of
an antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply with the
provisions of this section.

3.2 Test Result

This product has a permanent antenna, fulfill the requirement of this section.




Report No.: WTG19G07045028W                                Page 8 of 19                           RF Part 15.231


                                                                                                          Model: TR76G


4. Conducted Emissions

4.1 Test Procedure

The setup of EUT is according with per ANSI C63.10:2013 measurement procedure. The specification used was
with the FCC Part 15.207 Limit.
The external I/O cables were draped along the test table and formed a bundle 30 to 40 cm long in the middle.
The spacing between the peripherals was 10 cm.

4.2 Basic Test Setup Block Diagram




                                              Adapter                     EUT



     LISN




                                                                                                                 1.0 m
                                                           1.5
 To Receiver                  Non-conduction table
                              80 cm above Ground
                              Plane

                                                                              1. 5 m


4.3 Test Receiver Setup
During the conducted emission test, the test receiver was set with the following configurations:

     Start Frequency .......................................................................... 150 kHz
     Stop Frequency .......................................................................... 30 MHz
     Sweep Speed .............................................................................. Auto
     IF Bandwidth.............................................................................. 10 kHz
     Quasi-Peak Adapter Bandwidth ................................................. 9 kHz
     Quasi-Peak Adapter Mode ......................................................... Normal

4.4 Summary of Test Results/Plots

     Not Applicable, battery powered.




Report No.: WTG19G07045028W                                                 Page 9 of 19                    RF Part 15.231


                                                                                             Model: TR76G


5. Radiated Emissions

5.1 Standard Applicable

According to §15.231(b), the field strength of emissions from intentional radiators operated under this section
shall not exceed the following:




The limits on the field strength of the spurious emissions in the above table are based on the fundamental
frequency of the intentional radiator. Spurious emissions shall be attenuated to the average (or, alternatively,
CISPR quasi-peak) limits shown in this table or to the general limits shown in §15.209, whichever limit permits a
higher field strength.

The emission limit in this paragraph is based on measurement instrumentation employing an average detector. The
provisions in §15.35 for limiting peak emissions apply. Spurious Radiated Emissions measurements starting
below or at the lowest crystal frequency.

Compliance with the provisions of §15.205 shall be demonstrated using the measurement instrumentation
specified in that section.




Report No.: WTG19G07045028W                              Page 10 of 19                           RF Part 15.231


                                                                                       Model: TR76G

5.2 Test Procedure

The setup of EUT is according with per ANSI C63.10-2013 measurement procedure. The specification used was
with the FCC Part 15.205 15.231(b) and FCC Part 15.209 Limit.




                                                       Antenna
                                                        Tower
                                                                       1m-4m




                                   3m

           EUT SYS
                            1.5m




          Turntable
           Table                                                               To EMI Receiver



                                        Ground Plane




Report No.: WTG19G07045028W                            Page 11 of 19                      RF Part 15.231


                                                                                              Model: TR76G

5.3 Corrected Amplitude & Margin Calculation

The Corrected Amplitude is calculated by adding the Antenna Factor and the Cable Factor, and subtracting the
Amplifier Gain from the Amplitude reading. The basic equation is as follows:

                      Corr. Ampl. = Indicated Reading +Ant.Loss +Cab. Loss – Ampl.Gain

The “Margin” column of the following data tables indicates the degree of compliance with the applicable limit.
For example, a margin of -6dBV means the emission is 6dBV below the maximum limit. The equation for
margin calculation is as follows:
                                  Margin = Corr. Ampl. – FCC Part 15C Limit

5.4 Summary of Test Results/Plots

Note: this EUT was tested in 3 orthogonal positions and the worst case position data was reported.




Report No.: WTG19G07045028W                              Page 12 of 19                           RF Part 15.231


                                                                                          Model: TR76G



      Test Mode                    TM1                       Polarity:                    Horizontal




       No.   Frequency   Reading   Corr.     Dutycycle    Result         Limit   Margin    Remark
                  MHz    dBuV/m    Factor(    Factor     dBuV/m     dBuV/m        (dB)
                                    dB)        (dB)
        1    304.6099     89.88    -7.33       N/A        82.55          94.95   -12.40      peak
        2    304.6099         /       /        -9.41      73.14          74.95   -1.81       Ave
        3    610.0000     32.24    -3.90       N/A        28.34          46.00   -17.66      peak


Above 1GHz

       No.   Frequency   Reading   Corr.     Dutycycle    Result         Limit   Margin    Remark
                  MHz    dBuV/m    Factor     Factor     dBuV/m     dBuV/m        dB
                                    (dB)       (dB)
        1    1218.4396    60.76    -9.66       N/A        51.10          74.00   -22.90     Peak
             1218.4396        /       /        -9.41      41.69          54.00   -12.31      Ave
        2    1523.0495    57.88    -8.32       N/A        49.56          74.00   -24.44     Peak
             1523.0495        /       /        -9.41      40.15          54.00   -13.85      Ave




Report No.: WTG19G07045028W                        Page 13 of 19                             RF Part 15.231


                                                                                             Model: TR76G


       Test Mode                      TM1                       Polarity:                      Vertical




         No.   Frequency    Reading    Corr.    Dutycycle    Result         Limit   Margin    Remark
                   MHz      dBuV/m    Factor(    Factor     dBuV/m     dBuV/m        (dB)
                                        dB)       (dB)
         1     304.6099      82.01     -7.33      N/A        74.68          94.95   -20.27      peak
         2     304.6099        /         /        -9.41      65.27          74.95   -9.68       Ave
         3     610.0000      31.83     -3.90      N/A        27.93          46.00   -18.07      peak


Above 1GHz
         No.   Frequency    Reading    Corr.    Dutycycle    Result         Limit   Margin    Remark
                   MHz     dBuV/m     Factor     Factor     dBuV/m     dBuV/m        dB
                                       (dB)       (dB)
         1     1218.4396     63.92     -9.66      N/A        54.26          74.00   -19.74      Peak
               1218.4396       /         /        -9.41      44.85          54.00   -9.15       Ave


Note: Testing is carried out with frequency rang 9kHz to the tenth harmonics, which above 5th Harmonics are
attenuated more than 20dB below the permissible limits or the field strength is too small to be measured.
      The fundamental frequency is 304.25MHz, so the fundamental and spurious emissions radiated limit base
on the the operating frequency 304.25MHz.




Report No.: WTG19G07045028W                           Page 14 of 19                             RF Part 15.231


                                                                                        Model: TR76G


6. 20dB Bandwidth

6.1 Standard Applicable

According to FCC Part 15.231(c), The bandwidth of the emission shall be no wider than 0.25% of the center
frequency for devices operating above 70 MHz and below 900 MHz. Bandwidth is determined at the points 20 dB
down from the modulated carrier.

6.1 Test Procedure

With the EUT’s antenna attached, the EUT’s 20dB Bandwidth power was received by the test antenna, which was
connected to the spectrum analyzer with the START, and STOP frequencies set to the EUT’s operation band.


6.2 Summary of Test Results/Plots

      Test Frequency                  20dB Bandwidth             Limit
                                                                                          Result
           MHz                             kHz                   kHz
          304.25                   455.189                  760.6                          Pass
Limit = Fundamental Frequency X 0.25% = 304.25 MHz X 0.25% = 760 kHz

Please refer to the attached plots.




        304.25MHz




Report No.: WTG19G07045028W                            Page 15 of 19                        RF Part 15.231


                                                                                                Model: TR76G


7. Transmission Time

7.1 Standard Applicable

According to FCC Part 15.231 (a), the transmitter shall be complied the following requirements:

1) A manually operated transmitter shall employ a switch that will automatically deactivate the transmitter within
not more than 5 seconds of being released.
(2) A transmitter activated automatically shall cease transmission within 5 seconds after activation.
(3) Periodic transmissions at regular predetermined intervals are not permitted. However, polling or supervision
transmissions, including data, to determine system integrity of transmitters used in security or safety applications
are allowed if the total duration of transmissions does not exceed more than two seconds per hour for each
transmitter. There is no limit on the number of individual transmissions, provided the total transmission time does
not exceed two seconds per hour.

7.2 Test Procedure

With the EUT’s antenna attached, the EUT’s output signal was received by the test antenna, which was connected
to the spectrum analyzer. Set the center frequency to 304.25MHz, than set the spectrum analyzer to Zero Span for
the release time reading. During the testing, the switch was released then the EUT automatically deactivated.

7.3 Summary of Test Results/Plots

 Transmission Type        Test Frequency(MHz)        Transmission Time(s)            Limit(s)            Result
      Manually                        304.25                  0.325                      5                 Pass


Please refer to the attached plots.




        304.25MHz




Report No.: WTG19G07045028W                               Page 16 of 19                             RF Part 15.231


                                                                                             Model: TR76G


8. Duty Cycle

8.1 Standard Applicable

According to FCC Part 15.231 (b)(2) and 15.35 (c), For pulse operation transmitter, the averaging pulsed
emissions are calculated by peak value of measured emission plus duty cycle factor.

8.2 Test Procedure

With the EUT’s antenna attached, the EUT’s output signal was received by the test antenna, which was connected
to the spectrum analyzer. Set the center frequency to 304.25MHz, than set the spectrum analyzer to Zero Span for
the release time reading. During the testing, the switch was released then the EUT automatically deactivated.

8.3 Summary of Test Results/Plots

433.93MHz:
                           Width of Pulse                                Transmission Time   Total Time (Ton)
    Type of Pulse                                 Quantity of Pulse
                               (ms)                                            (ms)                (ms)
    Pulse 1 (Wide)               0.400                   18                      7.20
                                                                                                  12.80
   Pulse 2 (Narrow)              0.800                   7                       5.60


      Test Period (Tp)              Total Time (Ton)                Duty Cycle           Duty Cycle Factor
             ms                            ms                            %                      dB
             37.8                         12.80                        33.86                   -9.41
Remark: Duty Cycle Factor=20*log(Duty Cycle)

Please refer to the attached test plots




Report No.: WTG19G07045028W                                  Page 17 of 19                      RF Part 15.231


                                              Model: TR76G



304.25MHz




      Test Period




     Pulse Number




Report No.: WTG19G07045028W   Page 18 of 19      RF Part 15.231


                                                           Model: TR76G




   Pulse 1 and Pulse 2




                              ***** END OF REPORT *****




Report No.: WTG19G07045028W                Page 19 of 19      RF Part 15.231



Document Created: 2019-07-19 14:33:49