SAR exclusion report

FCC ID: 2AQVA-ONVAPAN51915

RF Exposure Info

Download: PDF
FCCID_4129866

             Radio Frequency Exposure Evaluation Report

                                      FOR: Digi Wireless Design Services, Inc.


                                       Marketing Name: Onvation PAN Module


   Product Description: Wireless module that connects to a sensor board and enables BLE
                           communications with external gateway.

                                            FCC ID: 2AQVA-ONVAPAN51915
                                              IC ID: 24318-ONVPAN51915

                                 Applied Rules and Standards:
                           CFR 47 Part 2.1093 and RSS-102 Issue 5
                     FCC KDB 447498 D01 General RF Exposure Guidance v06



                        Test Report #: SAR_EX_DIGII_045_18001_FCC_ISED

                                                          DATE: 01/02/2018




                                                                                               A2LA Accredited

                                                                                                IC recognized #
                                                                                                    3462B-2



                                                              CETECOM Inc.
                                         411 Dixon Landing Road  Milpitas, CA 95035  U.S.A.
                  Phone: + 1 (408) 586 6200  Fax: + 1 (408) 586 6299  E-mail: info@cetecom.com  http://www.cetecom.com
                                    CETECOM Inc. is a Delaware Corporation with Corporation number: 2905571

V4.0 2012-07-25           The BLUETOOTH trademarks are owned by Bluetooth SIG, Inc., U.S.A. and licensed to CETECOM Inc.    © Copyright by CETECOM


Test Report #:         SAR_EX_DIGII-045-18001_FCC_ISED                                                   FCC ID: 2AQVA-ONVAPAN51915
Date of Report:        01/02/2018                      Page 2 of 9                                       IC ID: 24318-ONVPAN51915




                                                                            Contents
1.      Assessment ................................................................................................................................................ 3
2.      Administrative Data .................................................................................................................................... 4
     2.1. Identification of the Testing Laboratory Issuing the Test Report ......................................................... 4
     2.2. Identification of the Client .................................................................................................................... 4
     2.3. Identification of the Manufacturer ........................................................................................................ 4
3.      Equipment under Assessment.................................................................................................................... 5
4.      FCC Exemption Limits for Routine Evaluation ............................................................................................ 6
     4.1. FCC SAR test exclusions are set by KDB 447498 D01 General RF Exposure Guidance v06 ............ 6
     4.2. RSS-102 ............................................................................................................................................. 6
        2.5.1 Exemption Limits for Routine Evaluation-SAR Evaluation ................................................................. 6
5.      Stand-Alone SAR Evaluation Exclusion ..................................................................................................... 8
6.      Revision History ......................................................................................................................................... 9


Test Report #:    SAR_EX_DIGII-045-18001_FCC_ISED                                  FCC ID: 2AQVA-ONVAPAN51915
Date of Report:   01/02/2018                      Page 3 of 9                      IC ID: 24318-ONVPAN51915


1. Assessment
The following device meets the limits of general population uncontrolled exposure specified in CFR 47 Part
2.1093 according to SAR evaluation exclusion requirements specified in FCC regulation as listed in KDB 447498
and the relevant ISED Canada standard RSS-RSS102, as it has been evaluated against the standards
mentioned above under this section.



Responsible for Testing Laboratory:


                                                                                                                     Digitally signed by Cindy Li
                                                                                                                     DN: cn=Cindy Li,
                                                                                                                     o=Cetecom Inc., ou=EMC,
                                                               Cindy Li                                              email=cindy.li@cetecom.co
                                                                                                                     m, c=US
                                                                                                                     Date: 2019.01.02 16:33:47
     01/02/2018          Compliance                         (Lab Manager)                                            -08'00'




         Date               Section                              Name                                        Signature



Responsible for the Report:
                                                                                                                 Digitally signed by: Issa
                                                                                                                 Ghanma
                                                                                                                 DN: CN = Issa Ghanma
                                                                                                                 email = issa.
                                                                                                                 ghanma@cetecom.com C
                                                                                                                 = US O = CETECOM INC.
                                                            Issa Ghanma                                           OU = EMC
                                                                                                                 Date: 2019.01.02 15:02:35
     01/02/2018            Compliance                      (EMC Engineer)                                         -08'00'


         Date                Section                             Name                                      Signature




The test results of this test report relate exclusively to the test item specified in Section3.
CETECOM Inc. USA does not assume responsibility for any conclusions and generalizations drawn from the test results with regard
to other specimens or samples of the type of the equipment represented by the test item. The test report may only be reproduced or
published in full. Reproduction or publication of extracts from the report requires the prior written approval of CETECOM Inc. USA.


Test Report #:    SAR_EX_DIGII-045-18001_FCC_ISED                         FCC ID: 2AQVA-ONVAPAN51915
Date of Report:   01/02/2018                      Page 4 of 9             IC ID: 24318-ONVPAN51915


2. Administrative Data
    2.1. Identification of the Testing Laboratory Issuing the Test Report


      Company Name:                        CETECOM Inc.
      Department:                          Compliance
      Street Address:                      411 Dixon Landing Road
      City/Zip Code                        Milpitas, CA 95035
      Country                              USA
      Telephone:                           +1 (408) 586 6200
      Fax:                                 +1 (408) 586 6299
      Compliance Manager:                  Cindy Li
      Responsible Project Manager:         Sangeetha Sivaraman


    2.2. Identification of the Client

      Applicant’s Name:                     Digi Wireless Design Services, Inc.
      Street Address:                       11001 Bren Rd E
      City/Zip Code                         Minnetonka, MN 55343
      Country                               USA

    2.3. Identification of the Manufacturer

      Applicant’s Name:                     Kimberly-Clark Professional

      Street Address:                       1400 Holcomb Bridge Road

      City/Zip Code                         Roswell, GA 30076
      Country                               USA


Test Report #:    SAR_EX_DIGII-045-18001_FCC_ISED                       FCC ID: 2AQVA-ONVAPAN51915
Date of Report:   01/02/2018                      Page 5 of 9           IC ID: 24318-ONVPAN51915


3. Equipment under Assessment


      Model #:                              51915
      FWIN:                                 1.0
      HVIN:                                 51915
      PMN:                                  Onvation PAN Module
      Hardware Version:                     1.0

      Software Version:                     1.0

      Minimum distance of antenna
                                    5mm
      or radiating parts to user
      Power Supply/ Rated Operating
                                    Low 2.7 VDC, Nominal 3.0 VDC, High 3.3 VDC
      Voltage Range:
      Operating Temperature Range:          Low 0⁰ C, Nominal 27⁰ C, High 50⁰ C
                                            Bluetooth LE in both advertising and connected mode of
      Modes of Operation:
                                            operation
      Other Radios included in the
                                            NA
      device:
      EUT Dimensions [cm]:                  2.5 x 6.3
      Weight (grams) :                      ~6.5
      Co-located Transmitters/
                                             Yes        No
      Antennas:
                                             Occupational/ Controlled  General Population/
      Exposure Category:
                                            Uncontrolled
                                            Fixed Installation Mobile
      Device Category:
                                             Portable           Mixed Mobile and Portable
      EUT Diameter:                          < 60 cm            Other __________
      Sample Revision                       Prototype Unit;    Production Unit;    Pre-Production


Test Report #:     SAR_EX_DIGII-045-18001_FCC_ISED                          FCC ID: 2AQVA-ONVAPAN51915
Date of Report:    01/02/2018                      Page 6 of 9              IC ID: 24318-ONVPAN51915


4. FCC Exemption Limits for Routine Evaluation
    4.1. FCC SAR test exclusions are set by KDB 447498 D01 General RF Exposure Guidance v06

       KDB 447498 Section: 4.3.1. Standalone SAR test exclusion considerations
               a) For 100 MHz to 6 GHz and test separation distances ≤ 50 mm, the 1-g and 10-g SAR test
               exclusion thresholds are determined by the following:

  [(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)] · [√f(GHz)]
                         ≤ 3.0 for 1-g SAR, and ≤ 7.5 for 10-g extremity SAR, where

              f(GHz) is the RF channel transmit frequency in GHz
              Power and distance are rounded to the nearest mW and mm before calculation
              The result is rounded to one decimal place for comparison
              The values 3.0 and 7.5 are referred to as numeric thresholds in step b) below
       The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm, and for
       transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is <
       5 mm, a distance of 5 mm according to 4.1 f) is applied to determine SAR test exclusion.


    4.2. RSS-102
               2.5.1 Exemption Limits for Routine Evaluation-SAR Evaluation

                   SAR evaluation is required if the separation distance between the user and/or bystander and
                    the antenna and/or radiating element of the device is less than or equal to 20 cm, except
                    when the device operates at or below the applicable output power level (adjusted for tune-up
                    tolerance) for the specified separation distance defined in Table 1.

                           Table 1: SAR evaluation — Exemption limits for routine evaluation based on
                                           frequency and separation distanceFootnote4,Footnote5

                                                         Exemption Limits (mW)


                       At separation     At separation      At separation        At separation    At separation
    Frequency           distance of       distance of        distance of          distance of      distance of
      (MHz)               ≤5 mm             10 mm               15 mm                20 mm            25 mm

       ≤300                71 mW            101 mW               132 mW            162 mW              193 mW

        450                52 mW             70 mW               88 mW             106 mW              123 mW

        835                17 mW             30 mW               42 mW              55 mW              67 mW

        1900               7 mW              10 mW               18 mW              34 mW              60 mW

        2450               4 mW              7 mW                15 mW              30 mW              52 mW


Test Report #:    SAR_EX_DIGII-045-18001_FCC_ISED                             FCC ID: 2AQVA-ONVAPAN51915
Date of Report:   01/02/2018                      Page 7 of 9                 IC ID: 24318-ONVPAN51915


                           Table 1: SAR evaluation — Exemption limits for routine evaluation based on
                                           frequency and separation distanceFootnote4,Footnote5

                                                          Exemption Limits (mW)


                      At separation       At separation       At separation       At separation     At separation
    Frequency          distance of         distance of         distance of         distance of       distance of
      (MHz)              ≤5 mm               10 mm                15 mm               20 mm             25 mm

        3500              2 mW               6 mW                16 mW               32 mW                55 mW

        5800              1 mW               6 mW                15 mW               27 mW                41 mW


                                                          Exemption Limits (mW)

                          At separation       At separation     At separation     At separation    At separation
    Frequency              distance of         distance of       distance of       distance of      distance of
      (MHz)                   30 mm               35 mm             40 mm             45 mm           ≥50 mm

        ≤300                223 mW               254 mW           284 mW            315 mW               345 mW

        450                 141 mW               159 mW           177 mW            195 mW               213 mW

        835                  80 mW               92 mW            105 mW            117 mW               130 mW

        1900                 99 mW               153 mW           225 mW            316 mW               431 mW

        2450                 83 mW               123 mW           173 mW            235 mW               309 mW

        3500                 86 mW               124 mW           170 mW            225 mW               290 mW

        5800                 56 mW               71 mW             85 mW             97 mW               106 mW




        Output power level shall be the higher of the maximum conducted or equivalent isotropically radiated
         power (e.i.r.p.) source-based, time-averaged output power. For controlled use devices where the 8
         W/kg for 1 gram of tissue applies, the exemption limits for routine evaluation in Table 1 are multiplied
         by a factor of 5. For limb-worn devices where the 10 gram value applies, the exemption limits for
         routine evaluation in Table 1 are multiplied by a factor of 2.5. If the operating frequency of the device
         is between two frequencies located in Table 1, linear interpolation shall be applied for the applicable
         separation distance. For test separation distance less than 5 mm, the exemption limits for a separation
         distance of 5 mm can be applied to determine if a routine evaluation is required.
         For medical implants devices, the exemption limit for routine evaluation is set at 1 mW. The output
         power of a medical implants device is defined as the higher of the conducted or e.i.r.p to determine
         whether the device is exempt from the SAR evaluation.


  Test Report #:    SAR_EX_DIGII-045-18001_FCC_ISED                                   FCC ID: 2AQVA-ONVAPAN51915
  Date of Report:   01/02/2018                      Page 8 of 9                       IC ID: 24318-ONVPAN51915


  5. Stand-Alone SAR Evaluation Exclusion
                 o According to KDB 447498, SAR evaluation can be excluded if the following equation is satisfied:

   [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·[√f(GHz)] ≤ 3.0 for 1-g
                                           SAR, and ≤ 7.5 for 10-g extremity SAR



                                 FCC Standalone Transmission SAR Exclusion Calculations

                    Max.Measured            Max.Declared                         P1/D*SQRT(F)    P2/D*SQRT(F)
 Frequency                                                        Distance                                         1-g ≤ 3.0
                    Output Power            Output Power                          at ≤ 5mm            at ≤ 5mm

    2.402                 1.59                    2.51                 5             0.49               0.78         Yes

    2.440                 1.54                    2.51                 5             0.48               0.78         Yes

    2.480                 1.42                    2.51                 5             0.45               0.79         Yes


            o   F: Frequency [GHz]
            o   P1: Max.Measured Output Power [mW]
            o   P2: Max.Declared Output Power [mW]
            o   D: Distance [mm]
            o   SQRT(F): Square root(Frequency[GHz])




                              ISED Standalone Transmission SAR Exclusion Calculations

Frequency       Max.Measured Output                            EIRP
                                                                                            Distance [mm]           Limit *1
  [MHz]             Power [mW]                                 [mW]
  2.402                    1.59                                 4.03                              5                  4.26

  2.440                    1.54                                 3.90                              5                  4.05

  2.480                    1.42                                 3.60                              5                  3.94


  *1: Limit by applying liner interpolation according to RSS-102 Section 2.5.1


Test Report #:    SAR_EX_DIGII-045-18001_FCC_ISED                         FCC ID: 2AQVA-ONVAPAN51915
Date of Report:   01/02/2018                      Page 9 of 9             IC ID: 24318-ONVPAN51915


6. Revision History

    Date                        Report Name                     Changes to report         Report prepared by
 01/02/2018          SAR_EX_DIGII-045-18001_FCC_ISED               Initial Version            Issa Ghanma



Document Created: 2019-01-02 16:33:48
Document Modified: 2019-01-02 16:33:48

© 2025 FCC.report