MPE_Test_Report

FCC ID: 2AQUQGL67240

RF Exposure Info

Download: PDF
FCCID_4480096

FCC ID: 2AQUQGL67240

                                 RF Exposure Evaluation
Limit
The criteria listed in the following table shall be used to evaluate the environment impact of human
exposure to radio frequency (RF) radiation as specified in 1.1310 & 2.1091
Table 1-Limits for Maximum Permissible Exposure (MPE)
   Frequency            Electric field
                                           Magnetic field strength   Power density     Averaging time
      range               strength                                                2
                                                   (A/m)               (mW/cm )          (minutes)
     (MHz)                  (V/m)
                             (A) Limits for Occupational/Controlled Exposures
    0.3–3.0                   614                   1.63                 *(100)              6
                                                                                2
     3.0–30                1842/f                  4.89/f               *(900/f )            6
    30–300                   61.4                  0.163                   1.0               6
   300–1500                    -                      -                   f/300              6
 1500–100,000                  -                      -                     5                6
                        (B) Limits for General Population/Uncontrolled Exposure
    0.3–1.34                  614                   1.63                 *(100)             30
                                                                                2
    1.34–30                 824/f                  2.19/f               *(180/f )           30
    30–300                   27.5                  0.073                   0.2              30
   300–1500                    -                      -                  f/1500             30
 1500–100,000                  -                      -                    1.0              30
Note: f = frequency in MHz


Evaluation Method
Transmission formula: Pd = (Pout*G)/(4*pi*R2)
Where
Pd = power density in mW/cm2, Pout = output power to antenna in mW, G = gain of antenna in
linear scale;
Pi = 3.1416, R = distance between observation point and center of the radiator in cm

Conducted Power Results
WIFI
                                                                    Conducted Peak Output Power
     Mode             Channel             Frequency (MHz)
                                                                               (dBm)
                           1                    2412                            7.34
    802.11b                6                    2437                            8.72
                          11                    2462                            8.65
                           1                    2412                            9.99
    802.11b                6                    2437                            9.34
                          11                    2462                           11.11
                           1                    2412                            9.88
802.11n(HT20)              6                    2437                            9.28
                          11                    2462                           11.02


FCC ID: 2AQUQGL67240

Manufacturing tolerance
WIFI
                                                     802.11b
      Channel                    Channel 1                      Channel 6              Channel 11
   Target (dBm)                       8                                8                     8
  Tolerance ±(dB)                     1                                1                     1
                                                     802.11g
      Channel                    Channel 1                      Channel 6              Channel 11
   Target (dBm)                       9                                9                     9
  Tolerance ±(dB)                     1                                1                     1
                                                    802.11n20
      Channel                    Channel 1                      Channel 6              Channel 11
   Target (dBm)                      10.5                             10.5                10.5
  Tolerance ±(dB)                     1                                1                     1

Evaluation Results
WIFI
               Antenna               EIRP                 Gain of        Power
                                                                                    Limit
 Band/Mode Distance                                     antenna in      Density                  Result
                              dBm           mW                                    (mW/cm2)
                 (cm)                                  linear scale    (mW/cm2)
  802.11b          20           9            7.94          1.78          0.003      1.0          Pass
  802.11g          20          10           10.00          1.78          0.004      1.0          Pass
 802.11n20         20         11.5          14.13          1.78          0.005      1.0          Pass

Remark:
1. Output power including tune up tolerance;
2. The maximum antenna gain is 2.5dBi
3. The exposure safety distance is 20cm.
4. EIRP = Conducted Peak Output Power + Antenna Gain + Tolerance

Conclusion
The measurement results comply with the FCC Limit per 47 CFR 1.1310 & 2.1091 for the
uncontrolled RF Exposure and MPE complicance per KDB 447498 v06.



Document Created: 2019-09-18 14:48:38
Document Modified: 2019-09-18 14:48:38

© 2024 FCC.report