Test report

FCC ID: 2AQUQGL52275

Test Report

Download: PDF
FCCID_4175068

                                                   TEST REPORT
Report No. ...................................... :       CHTEW19010037                 Report verification:

Project No. ...................................... :      SHT1812058601EW

FCC ID .............................................. :   2AQUQGL52275

Applicant’s name .............................. :         Globe Electric Company Inc

Address ............................................. :   150 Oneida Quebec, Canada H9R 1A8

Manufacturer......................................:       Globe Electric Company Inc

Address..............................................:    150 Oneida Quebec, Canada H9R 1A8

Test item description .................... :              Wireless charging desk lamp

Trade Mark ....................................... :      Globe

Model/Type reference ....................... :            GL52275

Listed Model(s) ................................. :       -

Standard ......................................... :      47 CFR FCC Part 18

Date of receipt of test sample………..:                      Dec.28,2018

Date of testing…………………………:                                Dec.28,2018 ~ Jan.09,2019

Date of issue…………………………...:                               Jan.09,2019

Result .................. …………………...:                     Pass

Compiled by
( position+printed name+signature) .. :                   File administrators Yueming Li
Supervised by
( position+printed name+signature) .. :                   Project Engineer Jerry Zhao
Approved by
( position+printed name+signature) .. :                   RF Manager Hans Hu



Testing Laboratory Name ............. :                   Shenzhen Huatongwei International Inspection Co., Ltd.

Address ............................................. :   1/F, Bldg 3, Hongfa Hi-tech Industrial Park, Genyu Road, Tianliao,
                                                          Gongming, Shenzhen, China

Shenzhen Huatongwei International Inspection Co., Ltd. All rights reserved.

This publication may be reproduced in whole or in part for non-commercial purposes as long as the
Shenzhen Huatongwei International Inspection Co., Ltd. is acknowledged as copyright owner and source of
the material. Shenzhen Huatongwei International Inspection Co., Ltd. takes no responsibility for and will not
assume liability for damages resulting from the reader's interpretation of the reproduced material due to its
placement and context.

The test report merely corresponds to the test sample.


                                                                  Page: 1 of 18


Report No : CHTEW19010037                                                Page 2 of 18                                                    Issued: 2019-01-09




                                                                         Contents

1.       TEST STANDARDS AND REPORT VERSION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

1.1.    Test Standards                                                                                                                                                    3
1.2.    Report version information                                                                                                                                        3

2.       TEST DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4



3.       SUMMARY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

3.1.    Client Information                                                                                                                                                5
3.2.    Product Description                                                                                                                                               5
3.3.    Operation state                                                                                                                                                   5
3.4.    EUT configuration                                                                                                                                                 5
3.5.    Modifications                                                                                                                                                     5

4.       TEST ENVIRONMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

4.1.    Address of the test laboratory                                                                                                                                    6
4.2.    Test Facility                                                                                                                                                     6
4.3.    Environmental conditions                                                                                                                                          7
4.4.    Statement of the measurement uncertainty                                                                                                                          7
4.5.    Equipments Used during the Test                                                                                                                                   8

5.       TEST CONDITIONS AND RESULTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

5.1.    Conducted Emissions Test                                                                                                                                          9
5.2.    Radiated Emissions Test                                                                                                                                           12

6.       TEST SETUP PHOTOS OF THE EUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 4



7.       EXTERNAL AND INTERNAL PHOTOS OF THE EUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 5




Shenzhen Huatongwei International Inspection Co., Ltd.                                                     Report Template Version: V01 (2018-01)


Report No : CHTEW19010037                         Page 3 of 18                   Issued: 2019-01-09



1. TEST STANDARDS AND REPORT VERSION
1.1. Test Standards
The tests were performed according to following standards:
47 CFR FCC Part 15 Subpart B - Unintentional Radiators
FCC/OST MP-5 -Methods of Measurements of Radio Noise Emissions from Industrial, Scientific and
Medical equipment (February 1986)


1.2. Report version information
      Revision No.                Date of issue                          Description
          N/A                      2019-01-09                              Original




Shenzhen Huatongwei International Inspection Co., Ltd.           Report Template Version: V01 (2018-01)


Report No : CHTEW19010037                       Page 4 of 18                              Issued: 2019-01-09



2. TEST DESCRIPTION
              Test Item                       Section in CFR 47                  Result         Test Engineer
        Conducted Emissions                    PART 18.307(b)                    Pass           Jeremy Zhang
         Radiated Emissions                    PART 18.305(b)                    Pass              Pan Xie


Note: The measurement uncertainty is not included in the test result.




Shenzhen Huatongwei International Inspection Co., Ltd.                  Report Template Version: V01 (2018-01)


Report No : CHTEW19010037                         Page 5 of 18                        Issued: 2019-01-09



3. SUMMARY
3.1. Client Information
Applicant:                     Globe Electric Company Inc
Address:                       150 Oneida Quebec, Canada H9R 1A8
Manufacturer:                  Globe Electric Company Inc
Address:                       150 Oneida Quebec, Canada H9R 1A8

3.2. Product Description
Name of EUT:                   Wireless charging desk lamp
Trade Mark:                    Globe
Model No.:                     GL52275
Listed Model(s)                -
Power supply:                  AC 120V
Adapter information:           -
Wireless Charger
Operation Frequency:           105kHz~205kHz

Rating output:                 5W


3.3. Operation state
        Keep the EUT in wireless charging mode.

3.4. EUT configuration
The following peripheral devices and interface cables were connected during the measurement:

● - supplied by the manufacturer
○ - supplied by the lab

                                                     Manufacturer :   APPLE
    ○     Mobile
                                                     Model No. :      Iphone X
                                                     Manufacturer :   N/A
    ○     N/A
                                                     Model No. :      N/A


3.5. Modifications
No modifications were implemented to meet testing criteria.




Shenzhen Huatongwei International Inspection Co., Ltd.                Report Template Version: V01 (2018-01)


Report No : CHTEW19010037                          Page 6 of 18                             Issued: 2019-01-09



4. TEST ENVIRONMENT
4.1. Address of the test laboratory
Laboratory: Shenzhen Huatongwei International Inspection Co., Ltd.
Address: 1/F, Bldg 3, Hongfa Hi-tech Industrial Park, Genyu Road, Tianliao, Gongming, Shenzhen, China
Phone: 86-755-26748019 Fax: 86-755-26748089
4.2. Test Facility
The test facility is recognized, certified, or accredited by the following organizations:

CNAS-Lab Code: L1225

Shenzhen Huatongwei International Inspection Co., Ltd. has been assessed and proved to be in compliance
with CNAS-CL01 Accreditation Criteria for Testing and Calibration Laboratories (identical to ISO/IEC17025:
2005 General Requirements) for the Competence of Testing and Calibration Laboratories.

A2LA-Lab Cert. No. 3902.01

Shenzhen Huatongwei International Inspection Co., Ltd. EMC Laboratory has been accredited by A2LA for
technical competence in the field of electrical testing, and proved to be in compliance with ISO/IEC 17025:
2005 General Requirements for the Competence of Testing and Calibration Laboratories and any additional
program requirements in the identified field of testing.

FCC-Registration No.: 762235

Shenzhen Huatongwei International Inspection Co., Ltd. EMC Laboratory has been registered and fully
described in a report filed with the FCC (Federal Communications Commission). The acceptance letter from
the FCC is maintained in our files. Registration 762235.

IC-Registration No.: 5377B-1

Two 3m Alternate Test Site of Shenzhen Huatongwei International Inspection Co., Ltd. has been registered by
Certification and Engineering Bureau of Industry Canada for the performance of radiated measurements with
Registration No. 5377B-1.

ACA

Shenzhen Huatongwei International Inspection Co., Ltd. EMC Laboratory can also perform testing for the
Australian C-Tick mark as a result of our A2LA accreditation.




Shenzhen Huatongwei International Inspection Co., Ltd.                   Report Template Version: V01 (2018-01)


Report No : CHTEW19010037                      Page 7 of 18                           Issued: 2019-01-09



4.3. Environmental conditions
During the measurement the environmental conditions were within the listed ranges:
Temperature:                                         15~35°C
Relative Humidity:                                       30~60 %
Air Pressure:                                            950~1050mba



4.4. Statement of the measurement uncertainty
The data and results referenced in this document are true and accurate. The reader is cautioned that there
may be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was
calculated for all measurements listed in this test report acc. to CISPR 16 - 4 „Specification for radio
disturbance and immunity measuring apparatus and methods – Part 4: Uncertainty in EMC
Measurements“ and is documented in the Shenzhen Huatongwei International Inspection Co., Ltd quality
system acc. to DIN EN ISO/IEC 17025. Furthermore, component and process variability of devices similar to
that tested may result in additional deviation. The manufacturer has the sole responsibility of continued
compliance of the device.

Hereafter the best measurement capability for Shenzhen Huatongwei laboratory is reported:

                                                                       Measurement
                Test                             Range                                     Notes
                                                                        Uncertainty
Radiated Emissions                         30~1000MHz                     4.28 dB           (1)
Radiated Emissions                           1~18GHz                      5.16 dB           (1)
Conducted Disturbance                      0.15~30MHz                     3.35 dB           (1)
(1) This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence
level using a coverage factor of k=1.96.




Shenzhen Huatongwei International Inspection Co., Ltd.              Report Template Version: V01 (2018-01)


Report No : CHTEW19010037                        Page 8 of 18                          Issued: 2019-01-09



4.5. Equipments Used during the Test
Conducted Emissions
                                                                                     Last Cal.    Next Cal.
Item   Test Equipment            Manufacturer          Model No.       Serial No.
                                                                                     (mm-dd-yy)   (mm-dd-yy)
1      EMI Test Receiver         R&S                   ESCI            101247        10/27/2018   10/26/2019
2      Artificial Mains          SCHWARZBECK           NNLK 8121       573           10/27/2018   10/26/2019
3      Pulse Limiter             R&S                   ESH3-Z2         101488        10/27/2018   10/26/2019
4      RF Connection Cable       HUBER+SUHNER          EF400           N/A           11/14/2017   11/13/2019
5      Test Software             R&S                   ES-K1           N/A           N/A          N/A
       Temperature and
6                                MIAOXIN               TH10R           N/A           10/30/2018   10/29/2019
       Humidity Meter


Radiated Emissions(Below 1GHz)
                                                                                     Last Cal.    Next Cal.
Item   Test Equipment            Manufacturer         Model No.         Serial No.
                                                                                     (mm-dd-yy)   (mm-dd-yy)
1      Semi-Anechoic Chamber     Albatross projects   SAC-3m-02         C11121       09/30/2018   09/29/2021
2      EMI Test Receiver         R&S                  ESCI              100900       10/28/2018   10/27/2019
3      Loop Antenna              R&S                  HFH2-Z2           100020       04/02/2018   04/02/2021
4      Ultra-Broadband Antenna   SCHWARZBECK          VULB9163          546          04/05/2017   04/04/2020
5      Pre-amplifer              SCHWARZBECK          BBV 9742          N/A          11/15/2018   11/14/2019
6      RF Connection Cable       HUBER+SUHNER         N/A               N/A          09/28/2018   09/27/2019
7      RF Connection Cable       HUBER+SUHNER         SUCOFLEX104       501184/4     09/28/2018   09/27/2019
8      Test Software             R&S                  ES-K1             N/A          N/A          N/A
9      Turntable                 Maturo Germany       TT2.0-1T          N/A          N/A          N/A
10     Antenna Mast              Maturo Germany       TAM-4.0-P         N/A          N/A          N/A
       Temperature and
11                               KEJIAN               KJ03              N/A          10/30/2018   10/29/2019
       Humidity Meter


Radiated Emissions(Above 1GHz)
                                                                                     Last Cal.    Next Cal.
Item   Test Equipment            Manufacturer         Model No.         Serial No.
                                                                                     (mm-dd-yy)   (mm-dd-yy)
1      Anechoic Chamber          Albatross projects   SAC-3m-01         C11121       09/30/2018   09/29/2021
2      Horn Antenna              SCHWARZBECK          9120D             1011         03/27/2017   03/26/2020
3      Preamplifier              BONN                 BLWA0160-2M       1811887      11/14/2018   11/13/2019
4      Broadband Pre-amplifier   SCHWARZBECK          BBV 9718          9718-248     04/28/2018   04/27/2019
5      Spectrum Analyzer         R&S                  FSP40             100597       10/27/2018   10/26/2019
6      RF Connection Cable       HUBER+SUHNER         RE-7-FL           N/A          11/15/2018   11/14/2019
7      RF Connection Cable       HUBER+SUHNER         RE-7-FH           N/A          11/15/2018   11/14/2019
8      Test Software             Audix                E3                N/A          N/A          N/A
9      Turntable                 Maturo Germany       TT2.0-1T          N/A          N/A          N/A
10     Antenna Mast              Maturo Germany       CAM-4.0-P-12      N/A          N/A          N/A
       Temperature and
11                               MINGLE               YH101             N/A          10/30/2018   10/29/2019
       Humidity Meter




Shenzhen Huatongwei International Inspection Co., Ltd.               Report Template Version: V01 (2018-01)


Report No : CHTEW19010037                          Page 9 of 18                        Issued: 2019-01-09



5. TEST CONDITIONS AND RESULTS
5.1. Conducted Emissions Test
LIMIT
According to §18.307 (b):
                                                                        Limit (dBuV)
          Frequency range (MHz)
                                                         Quasi-peak                       Average
                  0.15-0.5                                66 to 56*                       56 to 46*
                    0.5-5                                    56                              46
                    5-30                                     60                              50
* Decreases with the logarithm of the frequency.

TEST CONFIGURATION




TEST PROCEDURE
1. The EUT was setup according to test configuration
2. The EUT was placed on a plat form of nominal size, 1 m by 1.5 m, raised 10 cm above the conducting
   ground plane. The vertical conducting plane was located 40 cm to the rear of the EUT. All other surfaces
   of EUT were at least 10 cm from any other grounded conducting surface.
3. The EUT and simulators are connected to the main power through a line impedance stabilization
   network (LISN). The LISN provides a 50ohm / 50uH coupling impedance for the measuring equipment.
4. The peripheral devices are also connected to the main power through a LISN. (Please refer to the block
   diagram of the test setup and photographs)
5. Each current-carrying conductor of the EUT power cord, except the ground (safety) conductor,was
   individually connected through a LISN to the input power source.
6. The excess length of the power cord between the EUT and the LISN receptacle were folded back and
   forth at the center of the lead to form a bundle not exceeding 40 cm in length.
7. Conducted emissions were investigated over the frequency range from 0.15MHz to 30MHz using a
   receiver bandwidth of 9 kHz.
8. During the above scans, the emissions were maximized by cable manipulation.

TEST MODE:
Please refer to the clause 3.3

TEST RESULTS

   Passed               Not Applicable




Shenzhen Huatongwei International Inspection Co., Ltd.                Report Template Version: V01 (2018-01)


           Level {dBpV)




                                                   i
           ° 150k         300k 400k    SL.—
                                        eook sook 1M            2M                                            30M
                                                            Frequency [Hz]
         x x xmzs cm1901025046_fin

        MEASUREMENT RESULT:                        "GM1901025046_fin"

         1/3/2019  1:179M
            Frequency     Level                                                                               PE
                  MHz      dBuV                        ds      dBuv              dB

               0.262500               52.60         10.2             61         8.8    P            L1      GND
               0.789000               48.80          9.9             56          .28   QP           L1      GND
               1.050000               45.70         10.0             56        10.3    QP           L1      GND
               2.634000               45.20         10.0             56        10.8    oP           L1      GND
              10.923000               39.10         10.2             60        20.9    QP           L1      GND
              18.375000               33.20         10.3             60        26.8    oP           L1      GND




        MEASUREMENT RESULT:                        "GM1901025046_fin2"

         1/3/2019          1:17PM
             Frequency                Level      Transd      Limit           Margin    Detector     Line      PE
                          MEz          dBuv            dB      dBuy              dB

               0.262500               40.80         10.2             51        10.6    Av           L1      GND
               0.528000               39. 60        10.0             46         6.4    AV           L1      GND
               1.054500               36.50         10.0             46         9.5    AV           L1      GND
               2.368500               36.00         10.0             46        10.0     AV          L1      GND
              10.923000               29.40         10.2             50        20.6    AV           L1      GND
              18.366000               28 .40        10.3             50        21.6    AV           L1      GND




womermernace s nc ig eevacer                   reprovaner vey cen                 rruprcs    proee rviamven evalqevieu vay


  Level {dBpM)




                                              Frequency [Hz]

x x xmes    ou1901025044_fin


MEASUREMENT RESULT:                   "GM1901025044_fin"

1/3/2019          1:14PM
    Frequency               Level    Transd   Limit            Margin   Detector   Line    PE
                 MHz         dBuv        dB     dBuv               dB

      0.262500              35.50      10.2         61           25.9   P          N      GND
      0. 523500             48.10      10.0         56            7.9   QP         N      GND
      1.045500              34.80      10.0         56           21.2   P          N      GND
      2.616000              25.30      10.0         56           30.7   P          N      GND
      2.881500              24.20      10.0         56           31.8   Qp         N      GND
      3.142500              25 .90     10.0         56           30.1   P          N      GND




MEASUREMENT RESULT:                   "GM1901 025044_fi1'12"

1/3/2019           1:14PM
    Frequency               Level    Transd   Limit            Margin   Detector   Line    PE
                 MHz         dBuv        dB     dBu¥               dB

     0. 523500              36.70      10.0         46            9.3   AV         N      GND
    18.316500               23.40      10.3         50           26.6   AV         N      GND
    18.577500               22.70      10.3         50           27.3    AV        N      GND
    18.843000               22.20      10.3         50           27.8    AV        N      GND
    19.104000               22.10      10.3         50           27.9    AV        N      GND
    19.365000               42.10      10.3         50            7.9    aV        N      GND


Report No : CHTEW19010037                     Page 12 of 18                   Issued: 2019-01-09



5.2. Radiated Emissions Test
LIMIT

According to §18.307 (b):




TEST CONFIGURATION




Shenzhen Huatongwei International Inspection Co., Ltd.        Report Template Version: V01 (2018-01)


Report No : CHTEW19010037                      Page 13 of 18                         Issued: 2019-01-09

TEST PROCEDURE

1.    The EUT is placed on a turn table which is 0.8 meter above ground.
2.    The turn table is rotated 360 degrees to determine the position of the maximum emission level.
3.    The EUT waspositioned such that the distance from antenna to the EUT was 3 meters.
4.    The antenna is scanned from 1 meter to 4 meters to find out the maximum emission level. Thisis
      repeated for both horizontal and vertical polarization of the antenna.
5.    Use the following spectrum analyzer settings
      (1) Span shall wide enough to fully capture the emission being measured;
      (2) Below 30MHz
           RBW=9kHz, VBW=30kHz Sweep=auto, Detector function=peak, Trace=max hold;

TEST MODE:
Please refer to the clause 3.3

TEST RESULTS

     Passed             Not Applicable

Note:
1. Final Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor
2. This product belong to any non-ISM frequency equipment, the field strength limit is 15uV/m at 300 meter
3. Emission level dBµV/m for 0.009~30MHz = 20log (15) + 40log (300/3) dBµV/m;




Shenzhen Huatongwei International Inspection Co., Ltd.              Report Template Version: V01 (2018-01)


Report No : CHTEW19010037                     Page 14 of 18                   Issued: 2019-01-09



6. TEST SETUP PHOTOS OF THE EUT
Conducted Emissions (AC Mains)




Radiated Emissions (Below 30MHz)




Shenzhen Huatongwei International Inspection Co., Ltd.        Report Template Version: V01 (2018-01)


Report No : CHTEW19010037                     Page 15 of 18                    Issued: 2019-01-09



7. EXTERNAL AND INTERNAL PHOTOS OF THE EUT

                                              External Photo




Shenzhen Huatongwei International Inspection Co., Ltd.         Report Template Version: V01 (2018-01)


Report No : CHTEW19010037                     Page 16 of 18                   Issued: 2019-01-09




Shenzhen Huatongwei International Inspection Co., Ltd.        Report Template Version: V01 (2018-01)


Report No : CHTEW19010037                     Page 17 of 18                    Issued: 2019-01-09



                                              Internal Photo




Shenzhen Huatongwei International Inspection Co., Ltd.         Report Template Version: V01 (2018-01)


Report No : CHTEW19010037                     Page 18 of 18                     Issued: 2019-01-09