RF Exposure

FCC ID: 2AQUQGL52275

RF Exposure Info

Download: PDF
FCCID_4175066

FCC ID: 2AQUQGL52275                                                                                 Test date:2018-12-31


                                       RF Exposure Considerations
1. Measuring Standard
KDB 680106 D01 RF Exposure Wireless Charging Apps v02

2. TEST MODE
            Test Mode                                 Description                                 Remark
                   TM1                                5W OUTPUT                              With mobile phone

3. Requirements
According to the item 5.2 of KDB 680106 D01v03:
Inductive wireless power transfer applications that meet all of the following requirements are excluded from
submitting an RF exposure evaluation.
a) Power transfer frequency is less than 1 MHz.
b) Output power from each primary coil is less than or equal to 15 watts.
c) The transfer system includes only single primary and secondary coils. This includes charging systems that may
have multiple primary coils and clients that are able to detect and allow coupling only between individual pairs of
coils
d) Client device is placed directly in contact with the transmitter.
e) Mobile exposure conditions only (portable exposure conditions are not covered by this exclusion).
f) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all simultaneous
transmitting coils are demonstrated to be less than 50% of the MPE limit.




4. Test Equipment List
          Test                                                                           Last Cal.         Next Cal.
                           Manufacturer              Model No.         Serial No.
        Equipment                                                                      (mm-dd-yy)        (mm-dd-yy)

    Exposure LeveI
                                Narda                  ELT-400           F-0010         2018/10/28         2019/10/27
          Tester


FCC ID: 2AQUQGL52275                                                                              Test date:2018-12-31

5. Test Setup




Note: Measurements should be made from all sides and the top of the primary/client pair, with the 10cm measured
from the center of the probe(s) to the edge of the device.
6. Test Procedure
1) The RF exposure test was performed in anechoic chamber.
2) The measurement probe was placed at test distance (15cm) which is between the edge of the charger and the
geometric center of probe.
3) The highest emission level was recorded and compared with limit as soon as measurement of each
points (A, B, C, D, E, F) were completed.
4) The EUT was measured according to the dictates of KDB 680106 D01 v02.
Remark:
The EUT’s test position A, B, C, D, E and F is valid for the E and H field measurements
7. Test Result

                                               Electric Field Emissions
     Test Position              Measure Value (V/m)                                  Limit(V/m)
           Top                          25.557                                            614
          Bottom                        25.256                                            614
          Front                         22.550                                            614
          Rear                          18.040                                            614
           Left                         19.243                                            614
          Right                         19.243                                            614


FCC ID: 2AQUQGL52275                                                      Test date:2018-12-31

                                         Magnetic Field Emissions
                               B-field
    Test Position                                   Measure Value (A/m)   Limit(A/m)
                                (µT)
          Top                  0.085                         0.068           1.63
        Bottom                 0.084                         0.067           1.63
          Front                0.075                         0.060           1.63
          Rear                 0.060                         0.048           1.63
          Left                 0.064                         0.051           1.63
          Right                0.064                         0.051           1.63


Remark:
1. H-field strength(A/m)=B-field(µT)/1.25
2. dBuV/m=dBuA/m+51.5
3. V/m=10(((dBuV/m)-120)/20)
4. The EUT only has one coil, not applicable for 50% of the MPE limit.


8. Test Set-up Photo




                                                      15cm