Limit
The criteria listed in the following table shall be used to evaluate the environment impact of human
exposure to radio frequency (RF) radiation as specified in 1.1310 & 2.1091
Table 1-Limits for Maximum Permissible Exposure (MPE)
   Frequency            Electric field
                                           Magnetic field strength   Power density     Averaging time
      range               strength                                                2
                                                   (A/m)               (mW/cm )          (minutes)
      (MHz)                 (V/m)
                             (A) Limits for Occupational/Controlled Exposures
     0.3–3.0                  614                   1.63                 *(100)              6
                                                                                2
     3.0–30                1842/f                  4.89/f               *(900/f )            6
     30–300                  61.4                  0.163                    1.0              6
   300–1500                    -                      -                   f/300              6
 1500–100,000                  -                      -                      5               6
                        (B) Limits for General Population/Uncontrolled Exposure
    0.3–1.34                  614                   1.63                 *(100)             30
                                                                                2
    1.34–30                 824/f                  2.19/f               *(180/f )           30
     30–300                  27.5                  0.073                    0.2             30
   300–1500                    -                      -                  f/1500             30
 1500–100,000                  -                      -                     1.0             30
Note: f = frequency in MHz


Evaluation Method
Transmission formula: Pd = (Pout*G)/(4*pi*R2)
Where
Pd = power density in mW/cm2, Pout = output power to antenna in mW, G = gain of antenna in
linear scale;
Pi = 3.1416, R = distance between observation point and center of the radiator in cm

Conducted Power Results
WIFI
                                                                   Conducted Peak Output Power
     Mode             Channel            Frequency (MHz)
                                                                              (dBm)
                          1                     2412                             17.59
    802.11b               6                     2437                             17.33
                         11                     2462                              17.6
                          1                     2412                             17.21
    802.11b               6                     2437                             17.02
                         11                     2462                              17.2
                          1                     2412                             17.11
802.11n(HT20)             6                     2437                             17.04
                         11                     2462                             16.99


FCC ID: 2AQUQGE50020

Manufacturing tolerance
WIFI
                                                    802.11b
      Channel                    Channel 1                     Channel 6               Channel 11
   Target (dBm)                      17                              17                      17
  Tolerance ±(dB)                     1                              1                       1
                                                    802.11g
      Channel                    Channel 1                     Channel 6               Channel 11
   Target (dBm)                      17                              17                      17
  Tolerance ±(dB)                     1                              1                       1
                                                 802.11n20
      Channel                    Channel 1                     Channel 6               Channel 11
   Target (dBm)                      17                              17                      17
  Tolerance ±(dB)                     1                              1                       1

Evaluation Results
WIFI
              Antenna                EIRP                Gain of       Power
                                                                                    Limit
 Band/Mode Distance                                    antenna in     Density                     Result
                              dBm           mW                                    (mW/cm2)
               (cm)                                   linear scale   (mW/cm2)
  802.11b           20          21         125.89          3              0.025     1.0           Pass
  802.11g           20          21         125.89          3              0.025     1.0           Pass
 802.11n20          20          21         125.89          3              0.025     1.0           Pass


Remark:
1. Output power including tune up tolerance;
2. The maximum antenna gain is 3dBi
3. The exposure safety distance is 20cm.
4. EIRP = Conducted Peak Output Power + Antenna Gain + Tolerance

Conclusion
The measurement results comply with the FCC Limit per 47 CFR 1.1310 & 2.1091 for the
uncontrolled RF Exposure and MPE compliance per KDB 447498 v06.