180628001RFC-2 _FCC Part 1.1307 MPE REPORT

FCC ID: 2AQQS-888

RF Exposure Info

Download: PDF
FCCID_3962078

   Uni+nTrust                                                    Page 1 of 9                          Report No.: 180628001RFC—2




                FCC RF EXPOSURE EVALUATION
                          REPORT

                                                 Product Name:              WIRELESS INTERCOM SYSTERM
                                                        Model No.:          TD—888
                                               Report Number:               180628001RFC—2
                                                Test Standards:             FCC 47 CFR Part 1 Subpart
                                                             FCC ID:        2AQQS—888
                                                      Test Result:          PaASS
                                                   Date of Issue:           July 30, 2018

                                                                  Prepared for:

                                 Shenzhen Todakj Co., Ltd.
                  No. 40 Huan Dong Road, Tie Gang Industrial District, Bacan,
                                         Shenzhen


                                                                  Prepared by:
                  Shenzhen UnionTrust Quality and Technology Co., Ltd.
            16/F, Block A, Building 6, Baoneng Science and Technology Park,
                Qingxiang Road No.1, Longhua New District, Shenzhen, China
                                  TEL: +86—755—2823 0888
                                 FAX: +86—755—2823 0886




                    Tested by:                                                     Reviewed by:                       # Z ——~
                                                 enry llu                                                              n Liang
                                            Project Engineer



                                                   [\
                                                                                                             Assistant Manager


                                                                                                             s   ““s‘ Labor’
                Approved by:                                                                 Date:       *    {.Auly 30, 2018 °2
                                                  Billy Li                                                       UnientTrUS
                                           Technical Director
                                                                                                                 & Certitiece»
Shenzhen UnionTrust Qualityand Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua NewDistrict, Shenzhen, China
Tel: +86—755—28230888                  Fax: +86—755—28230886                  E—mail: info@uttfab.com               Hitps/www.uttlab.com


                                                                Page 2 of 9                           Report No.: 180628001RFC-2


Version
       Version No.                         Date                                                   Description
            V1.0                      July 30, 2018                                                  Original




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                                           Page 3 of 9                                  Report No.: 180628001RFC-2



                                                                        CONTENTS
1.   GENERAL INFORMATION ....................................................................................................................................... 4
     1.1      CLIENT INFORMATION ........................................................................................................................................ 4
     1.2      EUT INFORMATION ............................................................................................................................................ 4
     1.3      PRODUCT SPECIFICATION SUBJECTIVE TO THIS STANDARD ................................................................................. 4
     1.4      OTHER INFORMATION ......................................................................................................................................... 4
     1.5      GENERAL DESCRIPTION OF APPLIED STANDARDS ............................................................................................... 5
     1.6      TEST LOCATION ................................................................................................................................................. 5
     1.7      TEST FACILITY ................................................................................................................................................... 5
     1.8      DEVIATION FROM STANDARDS ............................................................................................................................ 5
     1.9      ABNORMALITIES FROM STANDARD CONDITIONS .................................................................................................. 6
     1.10     OTHER INFORMATION REQUESTED BY THE CUSTOMER ........................................................................................ 6
2.   EQUIPMENT LIST .................................................................................................................................................... 6
3.   MPE EVALUATION ................................................................................................................................................... 7
     3.1      REFERENCE DOCUMENTS FOR EVALUATION ........................................................................................................ 7
     3.2      MPE COMPLIANCE REQUIREMENT ..................................................................................................................... 7
              3.2.1 LIMITS ................................................................................................................................................... 7
              3.2.2 TEST PROCEDURE ................................................................................................................................. 7
     3.3      MPE CALCULATION METHOD ............................................................................................................................. 7
     3.4      MPE CALCULATION RESULTS ............................................................................................................................ 8
              3.4.1 FOR FRS .............................................................................................................................................. 8
APPENDIX 1 PHOTOS OF TEST SETUP ....................................................................................................................... 9
APPENDIX 2 PHOTOS OF EUT CONSTRUCTIONAL DETAILS ................................................................................... 9




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                                 Page 4 of 9                          Report No.: 180628001RFC-2

1. GENERAL INFORMATION
   1.1 CLIENT INFORMATION
         Applicant:                             Shenzhen Todakj Co., Ltd.
         Address of Applicant:                  No. 40 Huan Dong Road, Tie Gang Industrial District, Baoan, Shenzhen
         Manufacturer:                          Shenzhen Todakj Co., Ltd.
         Address of Manufacturer:               No. 40 Huan Dong Road, Tie Gang Industrial District, Baoan, Shenzhen


      1.2 EUT INFORMATION
         Product Name:                          WIRELESS INTERCOM SYSTERM
         Model No.:                             TD-888
                                                WL-888
         Add. Model No.:
                                                LD-888

                                                The trade mark of WL-888 is
         Trade Mark:
                                       The trade mark of LD-888 is
         DUT Stage:                    Identical Prototype
                                       FRS:
                                       462.5625 MHz to 462.7125 MHz
         EUT Supports Function:
                                       467.5625 MHz to 467.7125 MHz
                                       462.5500 MHz to 462.7250 MHz
         Note: The test data is gathered from a production sample, provided by the manufacturer. The marksof others
         models listed in the report is different from main-test model LD-888, but the circuit and the electronic
         construction do not change, declared by the manufacturer.


      1.3 PRODUCT SPECIFICATION SUBJECTIVE TO THIS STANDARD
                                                                                  462.5625 MHz to 462.7125 MHz
         Frequency Range:                       FRS:                              467.5625 MHz to 467.7125 MHz
                                                                                  462.5500 MHz to 462.7250 MHz
         Rated Output Power:                    FRS:                              0.5W(27dBm)
         Modulation Type:                       FRS:                              FM
         Channel Separation:                    FRS:                              12.5 KHz
         Modulation Type:                       FRS:                              F3E
         Maximum Transmitter
                                                FRS:                              22.82dbm
         Power (ERP):
         Number of Channels:                    22
         Antenna Type:                          Integral Antenna


      1.4 OTHER INFORMATION
                                                    Operation Frequency Each of Channel
                                                                    FRS
          Channel             Frequency               Channel         Frequency         Channel                                  Frequency
               1           462.5625 MHz                      8               467.5625 MHz                     15               462.5500 MHz
               2           462.5875 MHz                      9               467.5875 MHz                     16               462.5750 MHz
               3           462.6125 MHz                     10               467.6125 MHz                     17               462.6000 MHz
               4           462.6375 MHz                     11               467.6375 MHz                     18               462.6250 MHz
               5           462.6625 MHz                     12               467.6625 MHz                     19               462.6500 MHz
               6           462.6875 MHz                     13               467.6875 MHz                     20               462.6750 MHz

Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                                 Page 5 of 9                          Report No.: 180628001RFC-2

               7           462.7125 MHz                     14               467.7125 MHz                     21               462.7000 MHz
                                                                                                              22               462.7250 MHz


      1.5 GENERAL DESCRIPTION OF APPLIED STANDARDS

       The EUT is a RF product, according to the specifications of the manufacturers. It must comply with the
       requirements of the following standards:

       FCC 47 CFR Part 1 Subpart I

       All test items have been performed and recorded as per the above standards


      1.6 TEST LOCATION

       All tests were performed at:

       Shenzhen UnionTrust Quality and Technology Co., Ltd.

       Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua
       New District, Shenzhen, China 518109
       Telephone: +86 (0) 755 2823 0888
       Fax: +86 (0) 755 2823 0886


      1.7 TEST FACILITY

       The test facility is recognized, certified, or accredited by the following organizations:

       CNAS-Lab Code: L9069
       The measuring equipment utilized to perform the tests documented in this report has been calibrated once a
       year or in accordance with the manufacturer's recommendations, and is traceable under the ISO/IEC/EN 17025
       to international or national standards. Equipment has been calibrated by accredited calibration laboratories.

       IC-Registration No.: 21600-1
       The 3m Semi-anechoic chamber of Shenzhen UnionTrust Quality and Technology Co., Ltd. has been registered
       by Certification and Engineering Bureau of Industry Canada for radio equipment testing with Registration No.:
       21600-1.

       A2LA-Lab Certificate No.: 4312.01
       Shenzhen UnionTrust Quality and Technology Co., Ltd. has been accredited by A2LA for technical competence
       in the field of electrical testing, and proved to be in compliance with ISO/IEC 17025: 2005 General
       Requirements for the Competence of Testing and Calibration Laboratories and any additional program
       requirements in the identified field of testing.

       FCC Accredited Lab.
       Designation Number: CN1194
       Test Firm Registration Number: 259480



      1.8 DEVIATION FROM STANDARDS
       None.



Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                                Page 6 of 9                           Report No.: 180628001RFC-2

      1.9 ABNORMALITIES FROM STANDARD CONDITIONS
       None.

      1.10        OTHER INFORMATION REQUESTED BY THE CUSTOMER
       None.

2. EQUIPMENT LIST
       Please refer to the RF test report.




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                                Page 7 of 9                           Report No.: 180628001RFC-2

3. MPE EVALUATION
   3.1 REFERENCE DOCUMENTS FOR EVALUATION
          No.                      Identity                                       Document Title
                                                                PROCEDURES      IMPLEMENTING      THE    NATIONAL
            1      FCC 47 CFR Part 1 Subpart I
                                                                ENVIRONMENTAL POLICY ACT OF 1969
            2      KDB 447498 D01 General RF                    RF EXPOSURE PROCEDURES AND EQUIPMENT
                   Exposure Guidance v06                        AUTHORIZATION POLICIES FOR MOBILE AND PORTABLE
                                                                DEVICES


      3.2 MPE COMPLIANCE REQUIREMENT
      3.2.1       Limits

       According to §1.1307(b)(1), system operating under the provisions of this section shall be operating in a
       manner that the public is not exposed to radio frequency energy level in excess limit for maximum permissible
       exposure.

       Limits for Occupational / Controlled Exposure
                                 Electric Field     Magnetic Field                                                          Averaging Times
         Frequency range                                                                       Power Density (S)
                                 Strength (E)        Strength (H)                                                           | E |2, | H |2 or S
               (MHz)                                                                              (mW/cm2)
                                    (V/m)               (A/m)                                                                   (minutes)
               0.3-3.0               614                 1.63                                          (100)*                         6
                 3.0-30                       1842/f                       4.89/f                     (900/f)*                        6
                 30-300                        61.4                        0.163                        1.0                           6
                300-1500                         /                            /                        F/300                          6
              1500-100000                        /                            /                          5                            6

       Limits for General Population / Uncontrolled Exposure
                                Electric Field      Magnetic Field                                                          Averaging Times
         Frequency range                                                                       Power Density (S)
                                Strength (E)         Strength (H)                                                           | E |2, | H |2 or S
                (MHz)                                                                             (mW/cm2)
                                    (V/m)               (A/m)                                                                   (minutes)
              0.3-1.34               614                 1.63                                          (100)*                        30
               1.34-30              824/f               2.19/f                                        (180/f)*                       30
               30-300                27.5               0.073                                            0.2                         30
             300-1500                  /                   /                                          F/1500                         30
           1500-100000                 /                   /                                              1                          30

       Note: f = frequency in MHz: * = Plane-wave equivalents power density.

      3.2.2       Test Procedure
       Software provided by client enabled the EUT to transmit and receive data at lowest, middle and highest channel
       individually.

      3.3 MPE CALCULATION METHOD
       S = PG/4πR^2= EIRP/4πR^2
       S = power density (in appropriate units, e.g., mw/cm2)
       P = power input to the antenna (in appropriate units, e.g., mw)
       G = power gain of the antenna in the direction of interest relative to an isotropic radiator, the power gain factor
       is normally numeric gain.
       R = distance to the center of radiation of the antenna (in appropriate units, e.g., cm)




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                                Page 8 of 9                           Report No.: 180628001RFC-2

      3.4 MPE CALCULATION RESULTS
       Note: For the test results, the EUT had been tested with all conditions. But only the worst case was shown in
       test report.

      3.4.1       For FRS
       For FRS function, operating at 462.5625 MHz to 462.7125 MHz, 467.5625 MHz to 467.7125 MHz and 462.5500
       MHz to 462.7250 MHz for FM

      3.4.2.1 Antenna Type:
       Chain 0: Integral Antenna

      3.4.2.2 Results for FRS
                                                   Max. positive
                                   Declared                               Calculated           Declared
              Operating                             tolerance
                                   maximum                                maximum              maximum             MPE Limit         MPE Value
              Frequency                             according
                                     ERP                                    ERP                  ERP
                                                   manufacturer
                 (MHz)                (dBm)            (dB)                 (dBm)                 (mW)                      (mw/cm2)
           462.5625 MHz to                                                                                            0.3085
                                        26                ±1                   27                 501.19                                0.0997
            462.7125 MHz                                                                                             (F/1500)
           467.5625 MHz to                                                                                            0.3118
                                        26                ±1                   27                 501.19                                0.0997
            467.7125 MHz                                                                                             (F/1500)
           462.5500 MHz to                                                                                            0.3085
                                        26                ±1                   27                 501.19                                0.0997
            462.7250 MHz                                                                                             (F/1500)




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                                Page 9 of 9                           Report No.: 180628001RFC-2


APPENDIX 1 PHOTOS OF TEST SETUP
                                                                            N/A

APPENDIX 2 PHOTOS OF EUT CONSTRUCTIONAL DETAILS

                                          Refer to Appendix 2 for EUT external and internal photos.




                                                                 *** End of Report ***




       The test report is effective only with both signature and specialized stamp. The result(s) shown in this report refer
       only to the sample(s) tested. Without written approval of UnionTrust, this report can’t be reproduced except in full.




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com



Document Created: 2019-09-12 05:20:13
Document Modified: 2019-09-12 05:20:13

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC