Test Report

FCC ID: 2AQPBBAP-0713B

Test Report

Download: PDF
FCCID_4099522

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                      FCC ID: 2AQPBBAP-0713B            Report No.: LCS181025024AEA




                                                 FCC TEST REPORT
                                                                For
                                                Boost Auto Parts LLC
                                                             remote
                                               Test Model: BAP# 0713B
                            Additional Model No.: Please Refer to Page 6




  Prepared for                             :    Boost Auto Parts LLC
                                                Boost Auto Parts 2948 Kirk Road.Suite 106, #324 Aurora Illinois,
  Address                                  :
                                                UnitedStates 60502

  Prepared by                              :    Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                1/F., Xingyuan Industrial Park, Tongda Road, Bao’an Avenue,
  Address                                  :
                                                Bao’an District, Shenzhen, Guangdong, China
  Tel                                      :    (+86)755-82591330
  Fax                                      :    (+86)755-82591332
  Web                                      :    www.LCS-cert.com
  Mail                                     :    webmaster@LCS-cert.com

  Date of receipt of test sample           :    October 26, 2017
  Number of tested samples                 :    1
  Serial number                            :    Prototype
  Date of Test                             :    October 26, 2017 ~ November 16, 2017
  Date of Report                           :    November 21, 2017




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 1 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: 2AQPBBAP-0713B         Report No.: LCS181025024AEA


                                                           FCC TEST REPORT
                                                 FCC CFR 47 PART 15C(15.231)
Report Reference No. ................ : LCS181025024AEA

Date of Issue .................................. : November 21, 2017

Testing Laboratory Name............ : Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                        1/F., Xingyuan Industrial Park, Tongda Road, Bao’an Avenue,
Address .......................................... :
                                                        Bao’an District, Shenzhen, Guangdong, China
                                                        Full application of Harmonised standards ■
                                                   :
Testing Location/ Procedure ..........                  Partial application of Harmonised standards □
                                                        Other standard testing method □
Applicant’s Name ......................... : Boost Auto Parts LLC

                                                        Boost Auto Parts 2948 Kirk Road.Suite 106, #324 Aurora Illinois,
Address .......................................... :
                                                        UnitedStates 60502

Test Specification

Standard ......................................... : FCC CFR 47 PART 15 Subpart C; ANSI C63.10

Test Report Form No. .................... : LCSEMC-1.0

TRF Originator ............................... : Shenzhen LCS Compliance Testing Laboratory Ltd.

Master TRF .................................... : Dated 2011-03
Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the
Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the
material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not
assume liability for damages resulting from the reader's interpretation of the reproduced material due to its
placement and context.
Test Item Description. ............. : remote

Trade Mark ................................. : N/A

Test Model ................................. : BAP# 0713B

Ratings ....................................... : DC 3V

Result ....................................... : Positive


             Compiled by:                                      Supervised by:                            Approved by:




  Raing Ye / File administrators                       Calvin Weng / Technique principal            Gavin Liang/ Manager




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 2 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                       FCC ID: 2AQPBBAP-0713B           Report No.: LCS181025024AEA


                                                        FCC -- TEST REPORT

                                                                                             November 21, 2017
      Test Report No. :                            LCS181025024AEA                             Date of issue



   Test Mode...............................         : BAP# 0713B

   EUT.........................................     : remote


   Applicant...............................         : Boost Auto Parts LLC
                                                      Boost Auto Parts 2948 Kirk Road.Suite 106, #324 Aurora Illinois,
   Address..................................        :
                                                      UnitedStates 60502
   Telephone...............................         : /
   Fax..........................................    : /


   Manufacturer........................             : Wuxi Keyoung Electronic Technology Co., Ltd
                                                      5-301, 5-301 Huaqing Creative Park, Huishan Economic
   Address...................................       :
                                                      Development Zone, Wuxi, Jiangsu
   Telephone...............................         : /
   Fax..........................................    : /


   Factory...................................       : Wuxi Keyoung Electronic Technology Co., Ltd
                                                      5-301, 5-301 Huaqing Creative Park, Huishan Economic
   Address...................................       :
                                                      Development Zone, Wuxi, Jiangsu
   Telephone...............................         : /
   Fax..........................................    : /




                              Test Result                                                       Positive

  The test report merely corresponds to the test sample.
  It is not permitted to copy extracts of these test result without the written permission of the test laboratory.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 3 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                      FCC ID: 2AQPBBAP-0713B            Report No.: LCS181025024AEA


                                                    Revision History

          Revision                      Issue Date                            Revisions                        Revised By
            00                       November 21, 2017                       Initial Issue                     Gavin Liang




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 4 of 30


 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                                               FCC ID: 2AQPBBAP-0713B                       Report No.: LCS181025024AEA


                                                                 TABLE OF CONTENTS

1. GENERAL INFORMATION ................................................................................................................................... 6
   1.1. DESCRIPTION OF DEVICE (EUT) ........................................................................................................................ 6
   1.2. HOST SYSTEM CONFIGURATION LIST AND DETAILS .......................................................................................... 6
   1.3. EXTERNAL I/O CABLE ......................................................................................................................................... 6
   1.4. DESCRIPTION OF TEST FACILITY ........................................................................................................................ 6
   1.5. STATEMENT OF THE MEASUREMENT UNCERTAINTY .......................................................................................... 7
   1.6. MEASUREMENT UNCERTAINTY ........................................................................................................................... 7
   1.7. DESCRIPTION OF TEST MODES .......................................................................................................................... 7
2. TEST METHODOLOGY ......................................................................................................................................... 8
   2.1. EUT CONFIGURATION ........................................................................................................................................ 8
   2.2. EUT EXERCISE ................................................................................................................................................... 8
   2.3. GENERAL TEST PROCEDURES ........................................................................................................................... 8
3. SYSTEM TEST CONFIGURATION ...................................................................................................................... 9
   3.1. JUSTIFICATION .................................................................................................................................................... 9
   3.2. EUT EXERCISE SOFTWARE ................................................................................................................................ 9
   3.3. SPECIAL ACCESSORIES ...................................................................................................................................... 9
   3.4. BLOCK DIAGRAM/SCHEMATICS........................................................................................................................... 9
   3.5. EQUIPMENT MODIFICATIONS .............................................................................................................................. 9
   3.6. TEST SETUP ........................................................................................................................................................ 9
4. SUMMARY OF TEST RESULTS......................................................................................................................... 10
5. TEST ITEMS AND RESULTS .............................................................................................................................. 11
   5.1. TRANSMISSION CEASE TIME ............................................................................................................................. 11
   5.2. TRANSMITTER FIELD STRENGTH OF EMISSIONS .............................................................................................. 13
   5.3. 99% AND 20DB BANDWIDTH EMISSIONS ......................................................................................................... 22
   5.4. DUTY CYCLE ...................................................................................................................................................... 24
   5.5. AC POWER LINE CONDUCTED EMISSIONS (NOT APPLICABLE) ....................................................................... 27
   5.6. ANTENNA REQUIREMENT .................................................................................................................................. 28
6. LIST OF MEASURING EQUIPMENTS .............................................................................................................. 29
7. PHOTOGRAPHS OF TEST SETUP ................................................................................................................... 30
8. EXTERIOR PHOTOGRAPHS OF EUT .............................................................................................................. 30
9. INTERIOR PHOTOGRAPHS OF EUT ............................................................................................................... 30




      This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                     Page 5 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                       FCC ID: 2AQPBBAP-0713B             Report No.: LCS181025024AEA


1. GENERAL INFORMATION

 1.1. Description of Device (EUT)

      EUT                                        : remote
      Test Model                                 : BAP# 0713B
                                                     BAP# 0713, BAP# 0713R, BAP# 0713PL, BAP# 0713LG,
      Additional Model No.                       :
                                                   BAP# 0713RLG, BAP# 0713RPL, BAP# 0713LGPL
                                                   PCB board, structure and internal of these model(s) are the
      Model Declaration                          : same, So no additional models were tested.

      Power Supply                               : DC3.0V from 2*AAA battery
      Hardware version                           : 1.0
      Software version                           : 1.0
      Transmit Frequency                         : 315MHz
      Number of Channels                         : 1

      Modulation Type                            : FSK

      Antenna Description                        : PCB Antenna, 5dBi (Max.)


 1.2. Host System Configuration List and Details

                  Manufacturer                         Description           Model         Serial Number          Certificate
                            --                              --                  --                 ---                  --


 1.3. External I/O Cable

           I/O Port Description                             Quantity                                      Cable
                       --                                        --                                          --


 1.4. Description of Test Facility

   FCC Registration Number. is 254912.
   Industry Canada Registration Number. is 9642A-1.
   ESMD Registration Number. is ARCB0108.
   UL Registration Number. is 100571-492.
   TUV SUD Registration Number. is SCN1081.
   TUV RH Registration Number. is UA 50296516-001
   NVLAP Registration Code is 600167-0

   The 3m-Semi anechoic test site fulfils CISPR 16-1-4 according to ANSI C63.10:2013 and CISPR
   16-1-4:2010 SVSWR requirement for radiated emission above 1GHz.



  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 6 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                      FCC ID: 2AQPBBAP-0713B            Report No.: LCS181025024AEA

 1.5. Statement of the Measurement Uncertainty
   The data and results referenced in this document are true and accurate. The reader is cautioned that
   there may be errors within the calibration limits of the equipment and facilities. The measurement
   uncertainty was calculated for all measurements listed in this test report acc. To CISPR 16 – 4
   “Specification for radio disturbance and immunity measuring apparatus and methods – Part 4: Uncertainty
   in EMC Measurements” and is documented in the LCS quality system acc. To DIN EN ISO/IEC 17025.
   Furthermore, component and process variability of devices similar to that tested may result in additional
   deviation. The manufacturer has the sole responsibility of continued compliance of the device.

 1.6. Measurement Uncertainty
                    Test Item                       Frequency Range                      Uncertainty                Note
                                                      9KHz~30MHz                           ±3.10dB                   (1)
                                                    30MHz~200MHz                           ±2.96dB                   (1)
            Radiation Uncertainty           :      200MHz~1000MHz                          ±3.10dB                   (1)
                                                     1GHz~26.5GHz                          ±3.80dB                   (1)
                                                    26.5GHz~40GHz                          ±3.90dB                   (1)
           Conduction Uncertainty :                  150kHz~30MHz                          ±1.63dB                   (1)
              Power disturbance             :       30MHz~300MHz                           ±1.60dB                   (1)

   (1). This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence
   level using a coverage factor of k=2.

 1.7. Description of Test Modes


   The EUT has been tested under engineering mode. Press any one of the buttons on the EUT can transmit
   315MHz control signal. All buttons were tested for the pre-test, and we found that pressed the Button 1
   was the worst case. Only recorded the worst test case in this report.
   The field strength of radiation emission was measured in the following position: EUT stand-up position (Y
   axis), lie-down position (X, Z axis).
   The worst case of X axis was reported.

   ***Note: The active time of the transmitter is depended on the time how long the user pressed the button.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 7 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                      FCC ID: 2AQPBBAP-0713B            Report No.: LCS181025024AEA


2. TEST METHODOLOGY

   All measurements contained in this report were conducted with ANSI C63.10-2013, American National
   Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices.
   The radiated testing was performed at an antenna-to-EUT distance of 3 meters. All radiated and
   conducted emissions measurement was performed at Shenzhen LCS Compliance Testing Laboratory Ltd.

 2.1. EUT Configuration
   The EUT configuration for testing is installed on RF field strength measurement to meet the Commissions
   requirement and operating in a manner that intends to maximize its emission characteristics in a
   continuous normal application.

 2.2. EUT Exercise
   The EUT was operated in the engineering mode to fix the TX frequency that was for the purpose of the
   measurements.
   According to its specifications, the EUT must comply with the requirements of the Section 15.203, 15.205,
   15.207, 15.209 and 15.231 under the FCC Rules Part 15 Subpart C.

 2.3. General Test Procedures

  2.3.1 Conducted Emissions

   The EUT is placed on the turntable, which is 0.8 m above ground plane. According to the requirements in
   Section 6.2.1 of ANSI C63.10-2013 Conducted emissions from the EUT measured in the frequency range
   between 0.15 MHz and 30MHz using Quasi-peak and average detector modes.

  2.3.2 Radiated Emissions

   The EUT is placed on a turn table, which is 0.8 m above ground plane. The turntable shall rotate 360
   degrees to determine the position of maximum emission level. EUT is set 3m away from the receiving
   antenna, which varied from 1m to 4m to find out the highest emission. And also, each emission was to be
   maximized by changing the polarization of receiving antenna both horizontal and vertical. In order to find
   out the maximum emissions, exploratory radiated emission measurements were made according to the
   requirements in Section 6.3 of ANSI C63.10-2013.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 8 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                      FCC ID: 2AQPBBAP-0713B            Report No.: LCS181025024AEA


3. SYSTEM TEST CONFIGURATION

 3.1. Justification
   The system was configured for testing in a continuous transmit condition.
   Using sample to test, which was automatically launched

 3.2. EUT Exercise Software
   N/A
 3.3. Special Accessories
   N/A

 3.4. Block Diagram/Schematics
   Please refer to the related document

 3.5. Equipment Modifications
   Shenzhen LCS Compliance Testing Laboratory Ltd. has not done any modification on the EUT.

 3.6. Test Setup
   Please refer to the test setup photo.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 9 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                      FCC ID: 2AQPBBAP-0713B            Report No.: LCS181025024AEA



 4. SUMMARY OF TEST RESULTS

                                      Applied Standard: FCC Part 15 Subpart C
            FCC Rules                            Description of Test                                            Result
             §15.203                                 Antenna Requirement                                      Compliant
             §15.205                           Restricted Bands Of Operation                                  Compliant
             §15.207                           AC Mains Conducted Emission                                       N/A*
             §15.209               Radiated Emission Limits, General Requirements.                            Compliant
          §15.231 (b)                Field Strength Of Fundamental And Harmonics                              Compliant
          §15.231 (c)                             99% and 20dB Bandwidth                                      Compliant
         §15.231 (a)(1)                           Transmission Cease Time                                     Compliant

    Note:
  1.                    All buttons have been taken into consideration and only worst case reported.
  2.                    N/A – Not Applicable!!!




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 10 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                      FCC ID: 2AQPBBAP-0713B            Report No.: LCS181025024AEA



 5. TEST ITEMS AND RESULTS

 5.1. Transmission Cease Time

   5.1.1. Limit

   According to § 15.231 (a) (1), A manually operated transmitter shall employ a switch that will automatically
   deactivate the transmitter within not more than 5 seconds of being released.
   According to § 15.231 (a) (2), A transmitter activated automatically shall cease transmission within 5
   seconds after activation.

   5.1.2. Test Procedure

   Maximizing procedure was performed on the highest emissions to ensure that the EUT complied with all
   installation combinations. The antenna was all opened.

   5.1.3. Test Results

                                                             Limit: not more than 5 seconds
                                 Deactivation Time
     Frequency (MHz)                                                 of being released                       Conclusion
                                        (s)
                                                                            (s)
            315.00                       0.536                               5                                   PASS




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 11 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                      FCC ID: 2AQPBBAP-0713B            Report No.: LCS181025024AEA




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 12 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                      FCC ID: 2AQPBBAP-0713B            Report No.: LCS181025024AEA


 5.2. Transmitter Field Strength of Emissions

       5.2.1. Limit

   According to § 15.231 (b), In addition to the provisions of §15.205, the field strength of emissions from
   intentional radiators operated under this section shall not exceed the following:

                                                   Field strength of fundamental                Field strength of spurious
        Fundamental frequency (MHz)
                                                         (microvolts/meter)                    emissions (microvolts/meter)
                  40.66-40.70                                   2,250                                      225
                     71-130                                     1,250                                      125
                    130-174                               11,250 to 3,750                              1125 to 375
                    174-260                                     3,750                                      375
                    260-470                               13,750 to 12,500                            1375 to 1,250
                   Above 470                                  1 12,500                                    1,250
   1
    Linear interpolations.
   (1) The above field strength limits are specified at a distance of 3 meters. The tighter limits apply at the
   band edges.
   (2) Intentional radiators operating under the provisions of this section shall demonstrate compliance with
   the limits on the field strength of emissions, as shown in the above table, based on the average value of
   the measured emissions. As an alternative, compliance with the limits in the above table may be based on
   the use of measurement instrumentation with a CISPR quasi-peak detector. The specific method of
   measurement employed shall be specified in the application for equipment authorization. If average
   emission measurements are employed, the provisions in §15.35 for averaging pulsed emissions and for
   limiting peak emissions apply. Further, compliance with the provisions of §15.205 shall be demonstrated
   using the measurement instrumentation specified in that section.
   (3) The limits on the field strength of the spurious emissions in the above table are based on the
   fundamental frequency of the intentional radiator. Spurious emissions shall be attenuated to the average
   (or, alternatively, CISPR quasi-peak) limits shown in this table or to the general limits shown in §15.209,
   whichever limit permits a higher field strength.

          Frequencies(MHz)           Field Strength (microvolts/meter)             Measurement Distance (meters)
             0.009~0.490                        2400/F(KHz)                                    300
             0.490~1.705                       24000/F(KHz)                                    30
             1.705~30.0                              30                                        30
                30~88                               100                                         3
               88~216                               150                                         3
               216~960                              200                                         3
              Above 960                             500                                         3

   According to § 15.231 (e), Intentional radiators may operate at a periodic rate exceeding that specified in
   paragraph (a) of this section and may be employed for any type of operation, including operation
   prohibited in paragraph (a) of this section, provided the intentional radiator complies with the provisions of
   paragraphs (b) through (d) of this section, except the field strength table in paragraph (b) of this section is
   replaced by the following:

                                                   Field strength of fundamental                Field strength of spurious
        Fundamental frequency (MHz)
                                                         (microvolts/meter)                    emissions (microvolts/meter)
                  40.66-40.70                                  1,000                                       100
                     71-130                                      500                                        50
                    130-174                                 500 to 1,5001                               50 to 1501
                    174-260                                    1,500                                       150
                    260-470                               1,500 to 5,0001                              150 to 5001
                   Above 470                                   5,000                                       500




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 13 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                      FCC ID: 2AQPBBAP-0713B            Report No.: LCS181025024AEA


   5.2.2 Measuring Instruments and Setting


   Please refer to equipment’s list in this report. The following table is the setting of spectrum analyzer and
   receiver.

    Spectrum Parameter                                         Setting
    Attenuation                                                Auto
    Start Frequency                                            1000 MHz
    Stop Frequency                                             10th carrier harmonic
    RB / VB (Emission in restricted band)                      1MHz / 3MHz for Peak, 1 MHz / 10Hz for Average
    RB / VB (Emission in non-restricted band)                  1MHz / 3MHz for Peak, 1 MHz / 10Hz for Average

    Receiver Parameter                                    Setting
    Attenuation                                           Auto
    Start ~ Stop Frequency                                9kHz~150kHz / RB/VB 200Hz/1KHz for QP/Average
    Start ~ Stop Frequency                                150kHz~30MHz / RB/VB 9kHz/30KHz for QP/Average
    Start ~ Stop Frequency                                30MHz~1000MHz / RB/VB 120kHz/1MHz for QP

   5.2.3. Test Procedures


   1) Sequence of testing 9 kHz to 30 MHz
   Setup:
   --- The equipment was set up to simulate a typical usage like described in the user manual or described by
   manufacturer.
   --- If the EUT is a tabletop system, a rotatable table with 0.8 m height is used.
   --- If the EUT is a floor standing device, it is placed on the ground.
   --- Auxiliary equipment and cables were positioned to simulate normal operation conditions.
   --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
   --- The measurement distance is 3 meter.
   --- The EUT was set into operation.
   Premeasurement:
   --- The turntable rotates from 0° to 315° using 45° steps.
   --- The antenna height is 1.5 meter.
   --- At each turntable position the analyzer sweeps with peak detection to find the maximum of all
   emissions
   Final measurement:
   --- Identified emissions during the premeasurement the software maximizes by rotating the turntable
   position (0° to 360°) and by rotating the elevation axes (0° to 360°).
   --- The final measurement will be done in the position (turntable and elevation) causing the highest
   emissions with QPK detector.
   --- The final levels, frequency, measuring time, bandwidth, turntable position, correction factor, margin to
   the limit and limit will be recorded. Also a plot with the graph of the premeasurement and the limit will be
   stored.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 14 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                      FCC ID: 2AQPBBAP-0713B            Report No.: LCS181025024AEA



   2) Sequence of testing 30 MHz to 1 GHz

   Setup:
   --- The equipment was set up to simulate a typical usage like described in the user manual or described by
   manufacturer.
   --- If the EUT is a tabletop system, a table with 0.8 m height is used, which is placed on the ground plane.
   --- If the EUT is a floor standing device, it is placed on the ground plane with insulation between both.
   --- Auxiliary equipment and cables were positioned to simulate normal operation conditions
   --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
   --- The measurement distance is 3 meter.
   --- The EUT was set into operation.
   Premeasurement:
   --- The turntable rotates from 0° to 315° using 45° steps.
   --- The antenna is polarized vertical and horizontal.
   --- The antenna height changes from 1 to 3 meter.
   --- At each turntable position, antenna polarization and height the analyzer sweeps three times in peak to
   find the maximum of all emissions.
   Final measurement:
   --- The final measurement will be performed with minimum the six highest peaks.
   --- According to the maximum antenna and turntable positions of premeasurement the software maximize
   the peaks by changing turntable position (± 45°) and antenna movement between 1 and 4 meter.
   --- The final measurement will be done with QP detector with an EMI receiver.
   --- The final levels, frequency, measuring time, bandwidth, antenna height, antenna polarization, turntable
   angle, correction factor, margin to the limit and limit will be recorded. Also a plot with the graph of the
   premeasurement with marked maximum final measurements and the limit will be stored.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 15 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                      FCC ID: 2AQPBBAP-0713B            Report No.: LCS181025024AEA



   3) Sequence of testing 1 GHz to 18 GHz

   Setup:
   --- The equipment was set up to simulate a typical usage like described in the user manual or described by
   manufacturer.
   --- If the EUT is a tabletop system, a rotatable table with 1.5 m height is used.
   --- If the EUT is a floor standing device, it is placed on the ground plane with insulation between both.
   --- Auxiliary equipment and cables were positioned to simulate normal operation conditions
   --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
   --- The measurement distance is 3 meter.
   --- The EUT was set into operation.
   Premeasurement:
   --- The turntable rotates from 0° to 315° using 45° steps.
   --- The antenna is polarized vertical and horizontal.
   --- The antenna height is 1.5 meter.
   --- At each turntable position and antenna polarization the analyzer sweeps with peak detection to find the
   maximum of all emissions.
   Final measurement:
   --- The final measurement will be performed with minimum the six highest peaks.
   --- According to the maximum found antenna polarization and turntable position of the premeasurement
   the software maximizes the peaks by rotating the turntable position (0° to 360°). This measurement is
   repeated for different EUT-table positions (0° to 150° in 30°-steps). This procedure is repeated for both
   antenna polarizations.
   --- The final measurement will be done in the position (turntable, EUT-table and antenna polarization)
   causing the highest emissions with Peak and RMS detector.
   --- The final levels, frequency, measuring time, bandwidth, turntable position, EUT-table position, antenna
   polarization, correction factor, margin to the limit and limit will be recorded. Also a plot with the graph of
   the premeasurement with marked maximum final measurements and the limit will be stored.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 16 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                      FCC ID: 2AQPBBAP-0713B            Report No.: LCS181025024AEA



   4) Sequence of testing above 18 GHz

   Setup:
   --- The equipment was set up to simulate a typical usage like described in the user manual or described by
   manufacturer.
   --- If the EUT is a tabletop system, a rotatable table with 1.5 m height is used.
   --- If the EUT is a floor standing device, it is placed on the ground plane with insulation between both.
   --- Auxiliary equipment and cables were positioned to simulate normal operation conditions
   --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
   --- The measurement distance is 1 meter.
   --- The EUT was set into operation.
   Premeasurement:
   --- The antenna is moved spherical over the EUT in different polarizations of the antenna.
   Final measurement:
   --- The final measurement will be performed at the position and antenna orientation for all detected
   emissions that were found during the premeasurements with Peak and RMS detector.
   --- The final levels, frequency, measuring time, bandwidth, correction factor, margin to the limit and limit
   will be recorded. Also a plot with the graph of the premeasurement and the limit will be stored.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 17 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                      FCC ID: 2AQPBBAP-0713B            Report No.: LCS181025024AEA


   5.2.4. Test Setup Layout




   Above 18 GHz shall be extrapolated to the specified distance using an extrapolation factor of 20
   dB/decade form 3m to 1m.
   Distance extrapolation factor = 20 log (specific distance [3m] / test distance [1.5m]) (dB);
   Limit line = specific limits (dBuV) + distance extrapolation factor [6 dB].

   5.2.5. EUT Operation during Test

   The EUT was programmed to be in continuously transmitting mode.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 18 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                       FCC ID: 2AQPBBAP-0713B            Report No.: LCS181025024AEA


    5.2.6. Results of Radiated Emissions (9 KHz~30MHz)

             Temperature                        23.5℃                       Humidity                          51.3%
             Test Engineer                     Tom Liu                    Configurations                       TX

                Freq.                   Level                Over Limit               Over Limit
               (MHz)                   (dBuV)                  (dB)                     (dB)                    Remark
                  -                       -                      -                        -                    See Note

    Note:
    The amplitude of spurious emissions which are attenuated by more than 20 dB below the permissible
    value has no need to be reported.
    Distance extrapolation factor = 40 log (specific distance / test distance) (dB);
    Limit line = specific limits (dBuV) + distance extrapolation factor.

    5.2.7. Results of Radiated Emissions (30MHz~1GHz)

Horizontal




                          Fundamental and Harmonics Average Result
Frequency Peak Level AV Factor(dBµV/m) Average Level Limit(dBµV/m)
                                                                                                      Margin(dB)           Conclusion
  (MHz)    (dBµV/m)   (see Section 5.4)  (dBµV/m)      (average)
  315.48     69.69         -13.13          56.56          82.36                                           -25.80              PASS
  631.69     29.04         -13.13          15.91          62.36                                           -46.45              PASS
  945.44     40.71         -13.13          27.58          62.36                                           -34.78              PASS



   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 19 of 30


 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                       FCC ID: 2AQPBBAP-0713B            Report No.: LCS181025024AEA

Vertical




                          Fundamental and Harmonics Average Result
Frequency Peak Level AV Factor(dBµV/m) Average Level Limit(dBµV/m)
                                                                                                       Margin(dB)           Conclusion
  (MHz)    (dBµV/m)   (see Section 5.4)  (dBµV/m)      (average)
  315.48     74.37         -13.13          61.24          82.36                                            -21.12              PASS
  631.69     31.99         -13.13          18.86          62.36                                            -43.50              PASS
  945.44     34.84         -13.13          21.71          62.36                                            -40.65              PASS




    This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 20 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                       FCC ID: 2AQPBBAP-0713B            Report No.: LCS181025024AEA


    5.2.8. Results of Radiated Emissions (Above1GHz)

           Temperature                         25.1℃                         Humidity                     53.1%
                                                                                                   Harmonics Emissions/
           Test Engineer                     MINA XU                     Configurations
                                                                                                    Spurious Emission


                                                             Peak Value
            Frequency
                                   Level (dBuV/m)          Limit Line (dBuV/m)            Margin (dB)           Polarization
              (MHz)
             1259.94                     45.41                      74.00                     -28.59             Horizontal
             1575.05                     46.49                      74.00                     -27.51             Horizontal
             1890.14                     47.06                      74.00                     -26.94             Horizontal
             1259.93                     47.11                      74.00                     -26.89              Vertical
             1575.06                     46.77                      74.00                     -27.23              Vertical
             1890.10                     47.28                      74.00                     -26.72              Vertical

                                                          Average Value:
                            Peak              Duty         Average
        Frequency                                                      Limit Line
                            Level            cycle          value                            Margin (dB)         Polarization
          (MHz)                                                        (dBuV/m)
                          (dBuV/m)           factor       (dBuV/m)
          1259.88           45.44           -13.13          32.31        54.00                   -21.69           Horizontal
          1575.06           46.50           -13.13          33.37        54.00                   -20.63           Horizontal
          1890.13           47.05           -13.13          33.92        54.00                   -20.08           Horizontal
          1259.92           47.11           -13.13          33.98        54.00                   -20.02            Vertical
          1575.07           46.77           -13.13          33.64        54.00                   -20.36            Vertical
          1890.14           47.29           -13.13          34.16        54.00                   -19.84            Vertical

Remark:

1. Measuring frequencies from 9 KHz~10th harmonic (ex. 5GHz), No emission found between lowest internal
used/generated frequency to 30MHz.
2. Radiated emissions measured in frequency range from 9 KHz~10th harmonic (ex. 5GHz) were made with an
instrument using Peak detector mode.
3. Average values = Peak values + DC factor = Peak values – 13.13
3. Data of measurement within this frequency range shown “---” in the table above means the reading of
emissions are attenuated more than 20dB below the permissible limits or the field strength is too small to be
measured.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 21 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2AQPBBAP-0713B            Report No.: LCS181025024AEA


   5.3. 99% and 20dB Bandwidth Emissions

    5.3.1. Limit

    According to § 15.231 (d), the bandwidth of the emission shall be no wider than 0.25% of the center
    frequency for devices operating above 70 MHz and below 900 MHz. For devices operating above 900
    MHz, the emission shall be no wider than 0.5% of the center frequency. Bandwidth is determined at the
    points 20 dB down from the modulated carrier.
        0.25% of the center operating frequency
        0.5% of the center operating frequency

    5.4.2. Block Diagram of Test Setup




    5.3.2. Test Procedure

    Use the following spectrum analyzer settings:
    Span = 2MHz
    RBW = 10 KHz
    VBW = 30 KHz
    Sweep = auto
    Detector function = peak
    Trace = max hold
    The EUT should be transmitting at its maximum data rate. Allow the trace to stabilize. Use the
    marker-to-peak function to set the marker to the peak of the emission. Use the marker-delta function to
    measure 20 dB down one side of the emission. Reset the marker-delta function, and move the marker to
    the other side of the emission, until it is (as close as possible to) even with the reference marker level. The
    marker-delta reading at this point is the 20 dB bandwidth of the emission. If this value varies with different
    modes of operation (e.g., data rate, modulation format, etc.), repeat this test for each variation. The limit is
    specified in one of the subparagraphs of this Section. Submit this plot(s).

    5.3.3. Test Data

       Transmit Frequency                  Limit            20dB Bandwidth            99% Bandwidth             Result
             (MHz)                         (kHz)                (kHz)                     (kHz)
            315.00                        787.50                96.98                    134.05                  PASS


Remark:

1. Test results including cable loss;
2. Please refer following test plots;




    This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 22 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                      FCC ID: 2AQPBBAP-0713B            Report No.: LCS181025024AEA




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 23 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                      FCC ID: 2AQPBBAP-0713B            Report No.: LCS181025024AEA


 5.4. Duty cycle

   5.4.1. Limit

   No dedicated limit specified in the Rules.

   5.4.2. Block Diagram of Test Setup




   5.4.3. Test Procedure


   a. Place the EUT on the table and set it in transmitting mode.
   b. Remove the antenna from the EUT and then connect a low loss RF cable from the antenna port to the
      spectrum analyzer.
   c. Set centre frequency of spectrum analyzer=operating frequency.
   d. Set the spectrum analyzer as RBW=100 KHz, VBW=300 KHz, Span=0Hz, Adjust Sweep=100ms.
   e. Repeat above procedures until all frequency measured was complete.

   5.4.3. Test Results


       Ton = 0.05*1 + 0.5*24 + 0.25*40 = 22.05 ms
       Tp = 100 (ms)
       The duty cycle = (0.05*1 + 0.5*24 + 0.25*40) / 100= 22.05%
       Average Correction Factory = 20log (Ton/Tp) =20log (22.05/100) = -13.13 dB

   Note: The signal bandwidth was measured and less than 100 kHz RBW so PDCF factor is not required to
   correct the fundamental signal peak result.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 24 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                      FCC ID: 2AQPBBAP-0713B            Report No.: LCS181025024AEA




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 25 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                      FCC ID: 2AQPBBAP-0713B            Report No.: LCS181025024AEA




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 26 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                      FCC ID: 2AQPBBAP-0713B            Report No.: LCS181025024AEA


 5.5. AC Power Line Conducted Emissions (Not Applicable)

   5.5.1 Standard Applicable

   According to §15.207 (a): For an intentional radiator which is designed to be connected to the public utility
   (AC) power line, the radio frequency voltage that is conducted back onto the AC power line on any
   frequency or frequencies within the band 150 kHz to 30 MHz shall not exceed 250 microvolts (The limit
   decreases linearly with the logarithm of the frequency in the range 0.15 MHz to 0.50 MHz). The limits at
   specific frequency range is listed as follows:

              Frequency Range                                                   Limits (dBμV)
                    (MHz)                                   Quasi-peak                                  Average
                 0.15 to 0.50                                66 to 56                                   56 to 46
                  0.50 to 5                                     56                                         46
                   5 to 30                                      60                                         50

             * Decreasing linearly with the logarithm of the frequency

   5.5.2 Block Diagram of Test Setup




    5.5.3 Test Results


   Not Applicable!!!!
   The device was powered by DC battery!!!




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 27 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                      FCC ID: 2AQPBBAP-0713B            Report No.: LCS181025024AEA


 5.6. Antenna Requirement

   5.6.1. Standard Applicable

   According to § 15.203 and RSS-Gen, an intentional radiator shall be designed to ensure that no antenna
   other than that furnished by the responsible party shall be used with the device. The use of a permanently
   attached antenna or of an antenna that uses a unique coupling to the intentional radiator shall be
   considered sufficient to comply with the provisions of this section. The manufacturer may design the unit
   so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or electrical
   connector is prohibited.

   5.6.2. Antenna Connected Construction

   The directional gains of antenna used for transmitting is 5.0.dBi, and the antenna is an Internal PCB
   antenna connect to PCB board and no consideration of replacement. Please see EUT photo for details.

   5.6.3 Result

   Compliance.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 28 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                          FCC ID: 2AQPBBAP-0713B            Report No.: LCS181025024AEA


6. LIST OF MEASURING EQUIPMENTS

Item                Equipment                   Manufacturer           Model No.             Serial No.          Cal Date        Due Date
 1            MXA Signal Analyzer                  Agilent              N9020A             MY49100060           2018-11-15      2019-11-14
 2            DC Power Supply                    Agilent                E3642A                  N/A             2018-11-15      2019-11-14
            Temperature & Humidity             GUANGZHOU
 3                                                                      GDS-100                70932            2018-10-10      2019-10-09
                  Chamber                       GOGNWEN
 4            EMI Test Software                   AUDIX                    E3                     /             2018-06-16      2019-06-15
                                                   SIDT
 5        3m Semi Anechoic Chamber                                      SAC-3M              03CH03-HY           2018-06-16      2019-06-15
                                               FRANKONIA
 6            Positioning Controller                MF                  MF-7082                   /                 N/A             N/A
 7            Active Loop Antenna            SCHWARZBECK             FMZB 1519B                00005            2018-07-26      2019-07-25
 8               By-log Antenna              SCHWARZBECK               VULB9163              9163-470           2018-07-26      2019-07-25
 9                Horn Antenna               SCHWARZBECK             BBHA 9120D            9120D-1925           2018-07-02      2019-07-01
 10            EMI Test Receiver                     R&S                 ESR 7                101181            2018-06-16      2019-06-15
 11       RS SPECTRUM ANALYZER                       R&S                 FSP40                100503            2018-11-15      2019-11-14
 12                AMPLIFIER                      QuieTek                 QTK             CHM/0809065           2018-11-15      2019-11-14
 13              RF Cable-R03m                     Jye Bao  RG142          CB021        2018-06-16                              2019-06-15
                                                          SUCOFLEX
 14            RF Cable-HIGH                SUHNER                       03CH03-HY      2018-06-16                              2019-06-15
                                                             106
Note: All equipment is calibrated through GUANGZHOU LISAI CALIBRATION AND TEST CO.,LTD.




      This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                    Page 29 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                      FCC ID: 2AQPBBAP-0713B            Report No.: LCS181025024AEA



7. PHOTOGRAPHS OF TEST SETUP

   Please refer to separated files for Test Setup Photos of the EUT.


8. EXTERIOR PHOTOGRAPHS OF EUT

   Please refer to separated files for External Photos of the EUT.


9. INTERIOR PHOTOGRAPHS OF EUT

   Please refer to separated files for Internal Photos of the EUT.



                            ----------------THE END OF TEST REPORT---------------




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 30 of 30



Document Created: 2018-12-07 00:07:54
Document Modified: 2018-12-07 00:07:54

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC