2AQM7-AG55

FCC ID

Equipment: Asset Gateway

Keep Truckin, Inc. -AG55

55 Hawthorne St. Suite #400, San Francisco, CA 94105 United States

Application
Frequency Range
Final Action Date
Granted
K1VME+Pab5jdnefPESHOQA==
699.1-715.9
2019-10-09
APPROVED
K1VME+Pab5jdnefPESHOQA==
699.7-715.3
2019-10-09
APPROVED
K1VME+Pab5jdnefPESHOQA==
777.1-786.9
2019-10-09
APPROVED
K1VME+Pab5jdnefPESHOQA==
779.5-784.5
2019-10-09
APPROVED
K1VME+Pab5jdnefPESHOQA==
814.1-823.9
2019-10-09
APPROVED
K1VME+Pab5jdnefPESHOQA==
814.7-823.3
2019-10-09
APPROVED
K1VME+Pab5jdnefPESHOQA==
824.1-848.9
2019-10-09
APPROVED
K1VME+Pab5jdnefPESHOQA==
824.7-848.3
2019-10-09
APPROVED
K1VME+Pab5jdnefPESHOQA==
1710.1-1754.9
2019-10-09
APPROVED
K1VME+Pab5jdnefPESHOQA==
1710.7-1754.3
2019-10-09
APPROVED
K1VME+Pab5jdnefPESHOQA==
1850.1-1909.9
2019-10-09
APPROVED
K1VME+Pab5jdnefPESHOQA==
1850.7-1909.3
2019-10-09
APPROVED
8gtxdnXgOsYLooc0ELMwLQ==
2402.0-2480.0
2019-10-09
APPROVED
File NameDocument TypeDateDirect
MPERF Exposure Info 2019-10-09 00:00:00 pdf
Test Report_BLETest Report 2019-10-09 00:00:00 pdf
ConfidentialityCover Letter(s) 2019-10-09 00:00:00 pdf
Declaration of authorizationCover Letter(s) 2019-10-09 00:00:00 pdf
NB IoT CatM1_ver01_Part 4Test Report 2019-10-09 00:00:00 pdf
NB IoT CatM1_ver01_Part 3Test Report 2019-10-09 00:00:00 pdf
NB IoT CatM1_ver01_Part 2Test Report 2019-10-09 00:00:00 pdf
NB IoT CatM1_ver01_Part 1Test Report 2019-10-09 00:00:00 pdf
ID Label/Location InfoID Label/Location Info 2019-10-09 00:00:00 pdf
Block DiagramBlock Diagram N/A
External PhotosExternal Photos 2020-03-31 00:00:00 N/A
Internal PhotosInternal Photos 2020-03-31 00:00:00 N/A
Operational DescriptionOperational Description N/A
BOMParts List/Tune Up Info N/A
Tune-up ProcedureParts List/Tune Up Info N/A
SchematicsSchematics N/A
Setup Photo_BLETest Setup Photos 2020-03-31 00:00:00 N/A
Users ManualUsers Manual 2020-03-31 00:00:00 N/A
Setup Photo_NB IT Cat M1Test Setup Photos 2020-03-31 00:00:00 N/A

Application Details:

EquipmentAsset Gateway
FRN0027688258
Grantee Code2AQM7
Product Code-AG55
Applicant BusinessKeep Truckin, Inc.
Business Address55 Hawthorne St. Suite #400, San Francisco,California United States 94105
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
TCB Email[email protected]
ApplicantDaniel Nelson – Director of Quality and Compliance
Applicant Phone
Applicant Fax4082736497
Applicant Email[email protected]
Applicant MailStop
Test FirmSGS Taiwan Ltd. Electronics & Communication Lab
Test Firm ContactRyan WANG
Test Firm Phone 1473
Test Firm Fax+886-2-2299-2248
Test Firm Email[email protected]
Certified ByDaniel Nelson – Director of Quality and Compliance
Comment [8gtxdnXgOsYLooc0ELMwLQ==]: Power output listed is conducted. The antenna(s) used for this transmitter must be used to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.
Comment [K1VME+Pab5jdnefPESHOQA==]: Output power is ERP for Part 22 and 27(Below 1 GHz) )and EIRP for Part 24 and 27(Above 1GHz). The antenna(s) used for this transmitter must be used to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device contains functions that are not operational in U.S. Territories. This filing is only applicable for U.S. operations.