RF Exposure

FCC ID: 2AQISPOUT-00801

RF Exposure Info

Download: PDF
FCCID_4136080

                                                                Page 1 of 10                        Report No.: OT-18D-RWD-013




        ELECTROMAGNETIC EMISSION
           COMPLIANCE REPORT
 FOR LOW-POWER, NON-LICENSED TRANSMITTER

         Test Report No.               : OT-18D-RWD-013

         AGR No.                       : A187A-351

         Applicant                     : BROS & COMPANY INC.
         Address                       : A-101, InnoValley, 253, Pangyo-ro, Bundang-gu, Seongnam-si, Gyeonggi-do, Korea

         Manufacturer                  : Shenzhen Hongbo Innovation Co.,Ltd
         Address                       :4F, D, Xinshida Gongrong Distration, Shiyan Street, Baoanqu, Shenzhen,
                                        Guangdong, China

         Type of Equipment             : HANDS3

         FCC ID.                       : 2AQISPOUT-00801

         Model Name                    : POUT-00801

         Serial number                 : N/A

         Total page of Report          : 10 pages (including this page)

         Date of Incoming              : August 23, 2018

         Date of issue                 : December 10, 2018


         SUMMARY
         The equipment complies with the regulation; FCC CFR 47 PART 1.1310
         This test report only contains the result of a single test of the sample supplied for the examination.
         It is not a generally valid assessment of the features of the respective products of the mass-production.




         Reviewed by:                                                           Approved by:
                             Jae-Ho, Lee / Chief Engineer                                       Keun-Young, Choi / Vice President
                             ONETECH Corp.                                                      ONETECH Corp.




It should not be reproduced except in full, without the written approval of ONETECH Corp.                                  EMC-003 (Rev.3)
HEAD OFFICE      : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)
EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904)


                                                                            Page 2 of 10                                      Report No.: OT-18D-RWD-013


                                                                            CONTENTS
                                                                                                                                                                    PAGE

1. VERIFICATION OF COMPLIANCE ............................................................................................. 4

2. GENERAL INFORMATION ............................................................................................................5

   2.1 PRODUCT DESCRIPTION................................................................................................................................................. 5
   2.2 MODEL DIFFERENCES.................................................................................................................................................... 5

3. EUT MODIFICATIONS ....................................................................................................................5

4. RADIO FREQUENCY EXPOSURE ................................................................................................ 6

   4.1 ENVIRONMENTAL EVALUATION AND EXPOSURE LIMIT ................................................................................................ 6
   4.2 H / E FIELD STRENGTH ................................................................................................................................................... 8




It should not be reproduced except in full, without the written approval of ONETECH Corp.                                                                  EMC-003 (Rev.3)
HEAD OFFICE      : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)
EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904)


                                                                Page 3 of 10                        Report No.: OT-18D-RWD-013


                                                               Revision History


    Issue Report No.                Issued Date                                  Revisions                           Effect Section

   OT-18D-RWD-013               December 10, 2018                              Initial Release                            All




It should not be reproduced except in full, without the written approval of ONETECH Corp.                                  EMC-003 (Rev.3)
HEAD OFFICE      : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)
EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904)


                                                                 Page 4 of 10                       Report No.: OT-18D-RWD-013


1. VERIFICATION OF COMPLIANCE

Applicant                           : BROS & COMPANY INC.
Address                             : A-101, InnoValley, 253, Pangyo-ro, Bundang-gu, Seongnam-si, Gyeonggi-do, Korea
Contact Person                      : KIYEOL PARK / CEO
Telephone No.                       : +82-31-286-8646
FCC ID                              : 2AQISPOUT-00801
Model Name                          : POUT-00801
Serial Number                       : N/A
Date                                : December 10, 2018


 EQUIPMENT CLASS                                            DCD – Part 15 Low Power Transmitter Below 1 705 kHz
 KIND OF EQUIPMENT                                          HANDS3
 THIS REPORT CONCERNS                                       Original Grant
 MEASUREMENT PROCEDURES                                     ANSI C63.10: 2013
 TYPE OF EQUIPMENT TESTED                                   Pre-Production
 KIND OF EQUIPMENT
                                                            Certification
 AUTHORIZATION REQUESTED
 EQUIPMENT WILL BE OPERATED
                                                            FCC CFR 47 PART 1.1310
 UNDER FCC RULES PART(S)
 MODIFICATIONS ON THE EQUIPMENT
                                                            No
 TO ACHIEVE COMPLIANCE
 FINAL TEST WAS CONDUCTED ON                                3 m, Semi Anechoic Chamber

-. The above equipment was tested by ONETECH Corp. for compliance with the requirement set forth in the FCC Rules and
   Regulations. This said equipment in the configuration described in this report, shows the maximum emission levels
   emanating from equipment are within the compliance requirements.




It should not be reproduced except in full, without the written approval of ONETECH Corp.                                  EMC-003 (Rev.3)
HEAD OFFICE      : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)
EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904)


                                                                Page 5 of 10                        Report No.: OT-18D-RWD-013


2. GENERAL INFORMATION


2.1 Product Description
The BROS & COMPANY INC., Model: POUT-00801 (referred to as the EUT in this report) is a HANDS3. Product
specification information described herein was obtained from product data sheet or user’s manual.

 DEVICE TYPE                                     HANDS3_PRO
 OPERATING FREQUENCY                             110 kHz ~ 205 kHz
 RATED RF OUTPUT POWER                           55.10 dBμV/m
 ANTENNA TYPE                                    Coil Antenna
 MODULATION                                      ASK
 LIST OF EACH OSC. OR
                                                 110 kHz ~ 205 kHz
 CRY. FREQ.(FREQ. >= 1 MHz)
 RATED SUPPLY VOLTAGE                            DC 5.0 V


2.2 Model Differences

-. None

3. EUT MODIFICATIONS

-. None




It should not be reproduced except in full, without the written approval of ONETECH Corp.                                  EMC-003 (Rev.3)
HEAD OFFICE      : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)
EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904)


                                                                Page 6 of 10                          Report No.: OT-18D-RWD-013


4. RADIO FREQUENCY EXPOSURE


4.1 Environmental evaluation and exposure limit

According to FCC 1.1310 : The criteria listed in the following table shall be used to evaluate the environment impact of
human exposure to radio frequency (RF) radiation as specified in §1.1307(b), except in the case of portable devices which
shall be evaluated according to the provisions of FCC part 2.1093 of this chapter


   Frequency Range                 Electric Field               Magnetic Field              Power Density             Average Time
          [MHz]                   Strength [V/m]                Strength [A/m]               [mW/cm2]                    [minutes]
                                            (A) Limits for Occupational / Control Exposures
        0.3 – 3.0                        614                          1.63                     *(100)                        6
        3.0 – 30                       1 842/f                        4.89/f                  *(900/f2)                      6
        30 – 300                        61.4                          0.163                     1.0                          6
      300 – 1 500                                                                              f/300                         6
   1 500 – 100 000                                                                               5                           6
                                      (B) Limits for General Population/Uncontrolled Exposure
        0.3 – 3.0                        614                          1.63                     *(100)                       30
        3.0 – 30                        824/f                         2.19/f                  *(180/f2)                     30
        30 – 300                        27.5                          0.073                     0.2                         30
      300 – 1 500                                                                             f/1 500                       30
   1 500 – 100 000                                                                              1.0                         30

f = frequency in MHz
* = Plane wave equivalent power density

Note 1 to Table 1: Occupational/controlled limits apply in situations in which persons are exposed as a consequence of their
employment provided those persons are fully aware of the potential for exposure and can exercise control over their
exposure. Limits for occupational/controlled exposure also apply in situations when an individual is transient through a
location where occupational/controlled limits apply provided he or she is made aware of the potential for exposure.


Note 2 to Table 1: General population/uncontrolled exposures apply in situations in which the general public may be
exposed, or in which persons that are exposed as a consequence of their employment may not be fully aware of the potential
for exposure or can not exercise control over their exposure.




It should not be reproduced except in full, without the written approval of ONETECH Corp.                                  EMC-003 (Rev.3)
HEAD OFFICE      : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)
EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904)


                                                                Page 7 of 10                        Report No.: OT-18D-RWD-013


The EUT does meet the requirement of section 5.2 of KDB 680106

1. Power transfer frequency is less than 1MHz
2. Output power from each primary coil is less than 15 watts.
3. The transfer system includes only single primary and secondary coils.
4. Client devices is inserted in or placed directly in contact with the transmitter.
5. The device is applied for Mobile condition regarding the RF exposure.




It should not be reproduced except in full, without the written approval of ONETECH Corp.                                  EMC-003 (Rev.3)
HEAD OFFICE      : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)
EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904)


                                                                Page 8 of 10                        Report No.: OT-18D-RWD-013

4.2 H / E field strength
4.2.1 EUT Operating condition
              Mode                                   Charging current                                      Description
                                                           1 000 mA                                      Using Max load
        Charging Mode
                                                            500 mA                                       Using Mid load
          With load
                                                            100 mA                                       Using Min load

4.2.2 EUT Operating condition




4.2.3 Measurement procedure
1) The RF exposure test was performed in anechoic chamber.
2) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface.
3) The highest emission level was recorded and compared with limit as soon as measurement of each points (A, B, C, D, E)
   were completed.
4) The EUT was measured according to the dictates of KDB 680106 D01 v03.
Remark:
The EUT’s test position A, B, C, D and E is valid for the E and H field measurements.




It should not be reproduced except in full, without the written approval of ONETECH Corp.                                  EMC-003 (Rev.3)
HEAD OFFICE      : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)
EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904)


                                                                 Page 9 of 10                           Report No.: OT-18D-RWD-013

4.2.4 H - field strength
                                  Position A          Position B          Position C          Position D     Position E        Limits
           Mode
                                     [A/m]               [A/m]              [A/m]               [A/m]          [A/m]           [A/m]

      Charging Mode
      With Max. load
                                      0.13                0.12               0.17                0.18           0.20            1.63


      Charging Mode
      With Mid. load                  0.13                0.14               0.18                0.20           0.20            1.63


      Charging Mode
      With Min. load                  0.13                0.14               0.20                0.19           0.21            1.63

Note: The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface.
V/m=10(((dBuV /m)-120)/20) = 10(((dBuA/m+51.5)-120)/20) =10(((20lg(A/m*106 )+51.5)-120)/20)

A/m=uT/1.25




                                                                                            Tested by: Min-Gu, Ji / Project Engineer




It should not be reproduced except in full, without the written approval of ONETECH Corp.                                  EMC-003 (Rev.3)
HEAD OFFICE      : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)
EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904)


                                                                Page 10 of 10                       Report No.: OT-18D-RWD-013

4.3 LIST OF TEST EQUIPMENT
 No.            EQUIPMENTS                          MFR.             MODEL           SER. NO.     LAST CAL            DUE CAL         USE

   1         Exposure Level Meter                  NARDA              ELT-400         H-0013      2018. 07. 06        One Year         




It should not be reproduced except in full, without the written approval of ONETECH Corp.                                  EMC-003 (Rev.3)
HEAD OFFICE      : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)
EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904)



Document Created: 2019-03-26 17:28:22
Document Modified: 2019-03-26 17:28:22

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC