RF report (DCD)

FCC ID: 2AQISPOUT-00801

Test Report

Download: PDF
FCCID_4136079

                                                                Page 1 of 19                      Report No. : OT-18D-RWD-014




        ELECTROMAGNETIC EMISSION
           COMPLIANCE REPORT
 FOR LOW-POWER, NON-LICENSED TRANSMITTER

        Test Report No.                 : OT-18D-RWD-014

        AGR No                          : A187A-351

        Applicant                       : BROS&COMPANY INC.
        Address                         : A-101, InnoValley, 253, Pangyo-ro,Bundang-gu,                   Seongnam-si, Gyeonggi-do,
                                           Korea

        Manufacturer                    : Shenzhen Hongbo Innovation Co.,Ltd
        Address                         : 4F, D, Xinshida Gongrong Distration, Shiyan Street, Baoanqu, Shenzhen,
                                           Guangdong, China

        Type of Equipment               : HANDS3

        FCC ID.                         : 2AQISPOUT-00801

        Model Name                      : POUT-00801

        Multiple Model Name             : N/A

        Serial number                   : N/A

        Total page of Report            : 19 pages (including this page)

        Date of Incoming                : August 23, 2018

        Date of issue                   : December 10, 2018


        SUMMARY
        The equipment complies with the regulation;               FCC CFR47 Part 15 Subpart C Section 15.207 and
        15.209
        This test report only contains the result of a single test of the sample supplied for the examination.
        It is not a generally valid assessment of the features of the respective products of the mass-production.




         Reviewed by:                                                           Approved by:
                             Jae-Ho, Lee / Chief Engineer                                       Keun-Young, Choi / Vice President
                             ONETECH Corp.                                                      ONETECH Corp.

It should not be reproduced except in full, without the written approval of ONETECH Corp.                                  EMC-003 (Rev.3)
HEAD OFFICE      : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)
EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904)


                                                                             Page 2 of 19                                      Report No. : OT-18D-RWD-014


                                                                             CONTENTS
                                                                                                                                                                         PAGE

1. VERIFICATION OF COMPLIANCE .............................................................................................5

2. TEST SUMMARY ..............................................................................................................................6

  2.1 TEST ITEMS AND RESULTS ............................................................................................................................................. 6
  2.2 ADDITIONS, DEVIATIONS, EXCLUSIONS FROM STANDARDS .......................................................................................... 6
  2.3 RELATED SUBMITTAL(S) / GRANT(S) ............................................................................................................................ 6
  2.4 PURPOSE OF THE TEST ................................................................................................................................................... 6
  2.5 TEST METHODOLOGY .................................................................................................................................................... 6
  2.6 TEST FACILITY ............................................................................................................................................................... 6

3. GENERAL INFORMATION ............................................................................................................7

  3.1 PRODUCT DESCRIPTION ................................................................................................................................................. 7
  3.2 ALTERNATIVE TYPE(S)/MODEL(S); ALSO COVERED BY THIS TEST REPORT................................................................. 7

4. EUT MODIFICATIONS....................................................................................................................7

5. SYSTEM TEST CONFIGURATION ...............................................................................................8

  5.1 JUSTIFICATION ............................................................................................................................................................... 8
  5.2 PERIPHERAL EQUIPMENT .............................................................................................................................................. 8
  5.3 MODE OF OPERATION DURING THE TEST ...................................................................................................................... 8
  5.4 CONFIGURATION OF TEST SYSTEM ............................................................................................................................... 9
  5.5 ANTENNA REQUIREMENT .............................................................................................................................................. 9

6. PRELIMINARY TEST ....................................................................................................................10

  6.1 AC POWER LINE CONDUCTED EMISSIONS TESTS ....................................................................................................... 10

8. 20 DB BANDWIDTH .......................................................................................................................11

  8.1 OPERATING ENVIRONMENT ......................................................................................................................................... 11
  8.2 TEST SET-UP ................................................................................................................................................................. 11
  8.3 TEST DATA FOR 5V ....................................................................................................................................................... 11
  8.4 TEST DATA FOR 9V .................................................................................. 오류! 책갈피가 정의되어 있지 않습니다.

9. SPURIOUS EMISSION TEST ........................................................................................................12

  9.1 REGULATION ................................................................................................................................................................ 12
  9.2 TEST SET-UP ................................................................................................................................................................. 12
  9.3 TEST DATA FOR USING MAX LOAD (1 000 MA) ........................................................................................................... 13
     9.3.1 Spurious Radiated Emission Below 30 MHz ........................................................................................................13
It should not be reproduced except in full, without the written approval of ONETECH Corp.                                                                      EMC-003 (Rev.3)
HEAD OFFICE      : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)
EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904)


                                                                     Page 3 of 19                                 Report No. : OT-18D-RWD-014

     9.3.2 Spurious Radiated Emission below 1 GHz ...........................................................................................................14
  9.4 TEST DATA FOR USING MID. LOAD (500 MA) .............................................................................................................. 15
     9.4.1 Spurious Radiated Emission Below 30 MHz ........................................................................................................15
     9.4.2 Spurious Radiated Emission below 1 GHz ...........................................................................................................16
  9.5 TEST DATA FOR USING MIN. LOAD (100 MA) .............................................................................................................. 17
     9.5.1 Spurious Radiated Emission Below 30 MHz ........................................................................................................17
     9.5.2 Spurious Radiated Emission below 1 GHz ...........................................................................................................18
  10. LIST OF TEST EQUIPMENT ................................................................................................................................... 19




It should not be reproduced except in full, without the written approval of ONETECH Corp.                                                      EMC-003 (Rev.3)
HEAD OFFICE      : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)
EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904)


                                                                Page 4 of 19                      Report No. : OT-18D-RWD-014


                                                               Revision History


    Issue Report No.                Issued Date                                 Revisions                           Effect Section

  OT-18D-RWD-014                December 10, 2018                             Initial Release                             All




It should not be reproduced except in full, without the written approval of ONETECH Corp.                                  EMC-003 (Rev.3)
HEAD OFFICE      : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)
EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904)


                                                                 Page 5 of 19                     Report No. : OT-18D-RWD-014


1. VERIFICATION OF COMPLIANCE
APPLICANT                          : BROS&COMPANY INC.
ADDRESS                            : A-101, InnoValley, 253, Pangyo-ro,Bundang-gu, Seongnam-si, Gyeonggi-do, Korea
CONTACT PERSON                     : KIYEOL PARK / CEO
TELEPHONE NO                       : +82-31-286-8646
FCC ID                             : 2AQISPOUT-00801
MODEL NAME                         : POUT-00801
BRAND NAME                         : N/A
SERIAL NUMBER                      : N/A
DATE                               : December 10, 2018

 EQUIPMENT CLASS                                            FCC: DCD – Part 15 Low Power Transmitter Below 1 705 kHz
 KIND OF EQUIPMENT                                          HANDS3
 THIS REPORT CONCERNS                                       Original Grant
 MEASUREMENT PROCEDURES                                     ANSI C63.10: 2013
 TYPE OF EQUIPMENT TESTED                                   Pre-Production
 KIND OF EQUIPMENT
                                                            Certification
 AUTHORIZATION REQUESTED
 EQUIPMENT WILL BE OPERATED
                                                            FCC CFR47 Part 15 Subpart C Section 15.207 and 15.209
 UNDER FCC&IC RULES PART(S)
 MODIFICATIONS ON THE EQUIPMENT
                                                            No
 TO ACHIEVE COMPLIANCE
 FINAL TEST WAS CONDUCTED ON                                3 m, Semi Anechoic Chamber

-. The above equipment was tested by ONETECH Corp. for compliance with the requirement set forth in the FCC&IC Rules
   and Regulations. The equipment in the configuration described in this report shows the maximum emission levels
   emanating from equipment are within the compliance requirements.




It should not be reproduced except in full, without the written approval of ONETECH Corp.                                  EMC-003 (Rev.3)
HEAD OFFICE      : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)
EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904)


                                                                Page 6 of 19                      Report No. : OT-18D-RWD-014


2. TEST SUMMARY

2.1 Test items and results

      SECTION                                                 TEST ITEMS                                              RESULTS

15.209, 15.209(a)          Radiated emission, Spurious Emission and Field Strength of Fundamental                Met the Limit / PASS

2.1049                     20 dB Bandwidth                                                                       Met the Limit / PASS

15.207                     Transmitter AC Power Line Conducted Emission                                                   N/A


2.2 Additions, deviations, exclusions from standards
No additions, deviations or exclusions have been made from standard.

2.3 Related Submittal(s) / Grant(s)
Original submittal only


2.4 Purpose of the test
  To determine whether the equipment under test fulfills the requirements of the regulation stated in FCC CFR47 Part 15
Subpart C Section 15.207 and 15.209, 2.1049 and IC RSS-Gen Issue 4 and RSS-216 Issue 2.


2.5 Test Methodology
Radiated testing was performed according to the procedures in ANSI C63.10: 2013 at a distance of 3 m from EUT to the
antenna.


2.6 Test Facility
The Onetech Corp. has been designated to perform equipment testing in compliance with ISO/IEC 17025.
The Electromagnetic compatibility measurement facilities are located at 301-14, Daessangnyeong-ri, Chowol-eup, Gwangju-
si, Gyeonggi-do, 464-862 Korea.
-. Site Filing:
VCCI (Voluntary Control Council for Interference) – Registration No. R-4112/ C-4617/ G-666/ T-1842
IC (Industry Canada) – Registration No. Site# 3736-3
-. Site Accreditation:
KOLAS (Korea Laboratory Accreditation Scheme) - Accreditation NO. KT085
FCC (Federal Communications Commission) - Accreditation No. KR0013
RRA (Radio Research Agency) – Designation No. KR0013




It should not be reproduced except in full, without the written approval of ONETECH Corp.                                  EMC-003 (Rev.3)
HEAD OFFICE      : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)
EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904)


                                                                Page 7 of 19                      Report No. : OT-18D-RWD-014


3. GENERAL INFORMATION


3.1 Product Description
The BROS&COMPANY INC., Model: POUT-00801 (referred to as the EUT in this report) is a HANDS3. Product
specification information described herein was obtained from product data sheet or user’s manual.

 DEVICE TYPE                                     Wireless Charger
 OPERATING FREQUENCY                             110 kHz ~ 205 kHz
 RATED RF OUTPUT POWER                           55.10 dBμV/m
 ANTENNA TYPE                                    Coil Antenna
 MODULATION                                      ASK
 LIST OF EACH OSC. OR
                                                 110 kHz ~ 205 kHz
 CRY. FREQ.(FREQ. >= 1 MHz)
 RATED SUPPLY VOLTAGE                            DC 5.0 V


3.2 Alternative type(s)/model(s); also covered by this test report.

-. None

4. EUT MODIFICATIONS

-. None




It should not be reproduced except in full, without the written approval of ONETECH Corp.                                  EMC-003 (Rev.3)
HEAD OFFICE      : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)
EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904)


                                                                Page 8 of 19                         Report No. : OT-18D-RWD-014


5. SYSTEM TEST CONFIGURATION


5.1 Justification

This device was configured for testing in a typical way as a normal customer is supposed to be used. During the test, the
following components were installed inside of the EUT.

          DEVICE TYPE                            MANUFACTURER                           MODEL/PART NUMBER                      FCC ID

             Main Board                                    N/A                                       N/A                           N/A


5.2 Peripheral equipment
          Model                           Manufacturer                                 Description                   Connected to
            N/A                                  N/A                                  DUMMY load                             N/A


5.3 Mode of operation during the test

For the testing, software used to control the EUT for staying in continuous transmitting is programmed.
For final testing, the EUT was set at Max. load (115 kHz), Mid. load (115 kHz), and Min. load (115 kHz). To get a
maximum emission levels from the EUT, the EUT was moved throughout the XY, XZ, and YZ planes and the worst case is
“XY” axis.


              Mode                                   Charging current                                       Description
                                                          1 000 mA                                         Using Max. load
        Charging Mode
                                                           500 mA                                          Using Mid. load
          With load
                                                           100 mA                                          Using Min. load




It should not be reproduced except in full, without the written approval of ONETECH Corp.                                    EMC-003 (Rev.3)
HEAD OFFICE      : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)
EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904)


                                                                Page 9 of 19                      Report No. : OT-18D-RWD-014


5.4 Configuration of Test System
Line Conducted Test                      : The EUT was tested in a charging mode. The EUT was connected to USB and the
                                         power of USB was connected to Adapter. All supporting equipments were connected to
                                         another LISN. Preliminary Power line Conducted Emission test was performed by using
                                         the procedure in ANSI C63.4: 2009 7.3.3 to determine the worse operating conditions.
Radiated Emission Test                   : Preliminary radiated emissions test were conducted using the procedure in ANSI
                                         C63.10: 2013 to determine the worse operating conditions. Final radiated emission tests
                                         were conducted at 3 m Semi Anechoic Chamber.
                                         The turntable was rotated through 360 degrees and the EUT was tested by positioned
                                         three orthogonal planes to obtain the highest reading on the field strength meter. Once
                                         maximum reading was determined, the search antenna was raised and lowered in both
                                         vertical and horizontal polarization.


5.5 Antenna Requirement
According to section 15.203, an intentional radiator shall be designed to ensure that no antenna other than that furnished by
the responsible party shall be used with the device.

Antenna Construction:
The antenna of the EUT is a Coil Antenna on the main board in the EUT, so no consideration of replacement by the user.




It should not be reproduced except in full, without the written approval of ONETECH Corp.                                  EMC-003 (Rev.3)
HEAD OFFICE      : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)
EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904)


                                                                Page 10 of 19                     Report No. : OT-18D-RWD-014


6. PRELIMINARY TEST

6.1 AC Power line Conducted Emissions Tests
As this product is only using DC power, AC conducted emission test has not been performed.
6.2 General Radiated Emissions Tests
During Preliminary Tests, the following operating modes were investigated

                        Operation Mode                                   The Worse operating condition (Please check one only)

                       Transmitting Mode                                                             X




It should not be reproduced except in full, without the written approval of ONETECH Corp.                                  EMC-003 (Rev.3)
HEAD OFFICE      : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)
EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904)


                                                                Page 11 of 19                          Report No. : OT-18D-RWD-014


8. 20 dB BANDWIDTH


8.1 Operating environment

Temperature                          :      24 °C
Relative humidity                    :      46 % R.H.

8.2 Test set-up

a. Span = approximately 2 to 3 times the 20 dB bandwidth, RBW = greater than 1 % of the 20 dB bandwidth,
  VBW = RBW, Sweep = auto, Detector = peak, Trace = max hold.
b. The marker-to-peak function to set the mark to the peak of the emission. Use the marker-delta function to measure 20 dB
  down one side of the emission. Reset the function, and move the marker to the other side of the emission, until it is
  (as close as possible to) even with the reference marker level.
  The marker-delta reading at this point is 20 dB bandwidth of the emission.



                             EUT                                                            Spectrum analyzer



8.3 Test data for 5V

Test Date                      : September 19, 2018
Frequency                      : 115.3 KHz
20 dB Bandwidth                : 269.7 Hz




                                                                                            Tested by: Min-Gu, Ji / Project Engineer
It should not be reproduced except in full, without the written approval of ONETECH Corp.                                  EMC-003 (Rev.3)
HEAD OFFICE      : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)
EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904)


                                                                Page 12 of 19                       Report No. : OT-18D-RWD-014


9. Spurious Emission Test


9.1 Regulation

According to §15.209(a), for an intentional device, the general requirement of field strength of radiated emissions from
intentional radiators at a distance of 3 meters shall not exceed the following values:

                                              Field strength                       Field strength            Measurement distance
      Frequency [MHz]
                                                  [μ V/m]                            [dBμ V/m]                          [m]

         0.009 ~ 0.490                        2 400 / F (kHz)                                                           300
         0.490 ~ 1.705                       24 000 / F (kHz)                                                            30
           1.705 ~ 30                                30                                 29.50                            30
             30 ~ 88                                *100                                40.00                            3
            88 ~ 216                                *150                                43.52                            3
            216 ~ 960                               *200                                46.02                            3
           Above 960                                 500                                53.98                            3
*Except as provided in paragraph (g), fundamental emissions from intentional radiators operating under this Section shall
not be located in the frequency bands 54 ~ 72 MHz, 76 ~ 88 MHz, 174 ~ 216 MHz or 470 ~ 806 MHz. However, operation
within these frequency bands is permitted under other sections of this Part, e.g., Sections 15.231 and 15.241.


9.2 Test set-up

The radiated emissions measurements were on the 3 m semi anechoic chamber. The EUT and other support equipment were
placed on a non-conductive turntable above the ground plane. The interconnecting cables from outside test site were inserted
into ferrite clamps at the point where the cables reach the turntable.

The frequency spectrum from 30 kHz to 1 GHz was scanned and maximum emission levels at each frequency recorded. The
system was rotated 360°, and the antenna was varied in the height between 1.0 m and 4.0 ms in order to determine the
maximum emission levels. This procedure was performed for horizontal and vertical polarization of the receiving antenna.




It should not be reproduced except in full, without the written approval of ONETECH Corp.                                  EMC-003 (Rev.3)
HEAD OFFICE      : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)
EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904)


                                                                Page 13 of 19                          Report No. : OT-18D-RWD-014


9.3 Test data for Using Max load (1 000 mA)

9.3.1 Spurious Radiated Emission Below 30 MHz
Humidity Level           : 46 % R.H.                                                                                Temperature: 24 ºC

Limits apply to          : FCC CFR 47, PART 15, SUBPART C, SECTION 15.209

Frequency Range          : 9 kHz ~ 30 MHz

Result                   : PASSED

EUT                      : HANDS3                                                                               Date: September 18, 2018

Operating Condition : Transmitting Mode

         Frequency               Reading         Ant. Pol. Ant. Factor           Cable           Emission         Limits        Margin
          (MHz)                   (dBμV)           (H/V)         (dB/m)          Loss         Level(dBμV/m)      (dBμV/m)        (dB)

           0.016                    10.4             H            19.00           0.1              29.50           123.52        94.02
           0.034                    15.3             H            19.40           0.1              34.80           116.97        82.17
           0.068                    20.1             H            19.40           0.1              39.60           110.95        71.35
           0.115                    35.6             H            19.40           0.1              55.10           106.39        51.29
           0.389                    23.2             H            19.40           0.1              42.71           95.81         53.10
           26.09                    32.1             H            20.30           0.8              53.20           70.00         16.80

-. Remark: “H” Horizontal, “V” Vertical
-. “*” Means Fundamental frequency
-. Emission Level [dBμV/m] = Reading [dBμV] + Ant. Factor [dB/m] + Cable Loss [dB]
-. Margin [dB] = Emission Level [dBμV/m] – Limit [dBμV/m]
-. Limit calculation: Limit at specified distance + 40log (300/3) = Limit + 80 dB for up to 0.49 MHz
                       Limit at specified distance + 40log (30/3) = Limit + 40 dB for above 0.49 MHz, Below 30 MHz




                                                                                            Tested by: Min-Gu, Ji / Project Engineer




It should not be reproduced except in full, without the written approval of ONETECH Corp.                                   EMC-003 (Rev.3)
HEAD OFFICE      : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)
EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904)


                                                                Page 14 of 19                          Report No. : OT-18D-RWD-014



9.3.2 Spurious Radiated Emission below 1 GHz
The following table shows the highest levels of radiated emissions on both polarizations of horizontal and vertical.

Humidity Level           : 46 % R.H.                                                                                Temperature: 24 ºC

Limits apply to          : FCC CFR 47, PART 15, SUBPART C, SECTION 15.209

Frequency range          : 30 MHz ~ 1 000 MHz

Result                   : PASSED

EUT                      : HANDS3                                                                               Date: September 18, 2018

Operating Condition : Transmitting Mode




                                                                                            Tested by: Min-Gu, Ji / Project Engineer


It should not be reproduced except in full, without the written approval of ONETECH Corp.                                  EMC-003 (Rev.3)
HEAD OFFICE      : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)
EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904)


                                                                Page 15 of 19                          Report No. : OT-18D-RWD-014

9.4 Test data for Using Mid. load (500 mA)
9.4.1 Spurious Radiated Emission Below 30 MHz
Humidity Level           : 46 % R.H.                                                                                Temperature: 24 ºC

Limits apply to          : FCC CFR 47, PART 15, SUBPART C, SECTION 15.209

Frequency Range          : 9 kHz ~ 30 MHz

Result                   : PASSED

EUT                      : HANDS3                                                                               Date: September 18, 2018

Operating Condition : Transmitting Mode

         Frequency               Reading         Ant. Pol. Ant. Factor           Cable           Emission         Limits        Margin
          (MHz)                   (dBμV)           (H/V)         (dB/m)          Loss         Level(dBμV/m)      (dBμV/m)        (dB)

           0.016                     9.8             H            19.00           0.1              28.90           123.52        94.62
           0.031                    16.3             H            19.40           0.1              35.80           117.78        81.98
           0.076                    18.7             H            19.40           0.1              38.20           109.99        71.79
           0.115                    31.6             H            19.40           0.1              51.05           106.39        55.34
           0.367                    22.1             H            19.40           0.1              41.63           96.31         54.68
           25.7                     30.1             H            20.30           0.8              51.20           70.00         18.80

-. Remark: “H” Horizontal, “V” Vertical
-. “*” Means Fundamental frequency
-. Emission Level [dBμV/m] = Reading [dBμV] + Ant. Factor [dB/m] + Cable Loss [dB]
-. Margin [dB] = Emission Level [dBμV/m] – Limit [dBμV/m]
-. Limit calculation: Limit at specified distance + 40log (300/3) = Limit + 80 dB for up to 0.49 MHz
                       Limit at specified distance + 40log (30/3) = Limit + 40 dB for above 0.49 MHz, Below 30 MHz




                                                                                            Tested by: Min-Gu, Ji / Project Engineer




It should not be reproduced except in full, without the written approval of ONETECH Corp.                                   EMC-003 (Rev.3)
HEAD OFFICE      : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)
EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904)


                                                                Page 16 of 19                          Report No. : OT-18D-RWD-014



9.4.2 Spurious Radiated Emission below 1 GHz
The following table shows the highest levels of radiated emissions on both polarizations of horizontal and vertical.

Humidity Level           : 46 % R.H.                                                                                Temperature: 24 ºC

Limits apply to          : FCC CFR 47, PART 15, SUBPART C, SECTION 15.209

Frequency range          : 30 MHz ~ 1 000 MHz

Result                   : PASSED

EUT                      : HANDS3                                                                               Date: September 18, 2018

Operating Condition : Transmitting Mode




                                                                                            Tested by: Min-Gu, Ji / Project Engineer


It should not be reproduced except in full, without the written approval of ONETECH Corp.                                  EMC-003 (Rev.3)
HEAD OFFICE      : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)
EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904)


                                                                Page 17 of 19                          Report No. : OT-18D-RWD-014


9.5 Test data for Using Min. load (100 mA)

9.5.1 Spurious Radiated Emission Below 30 MHz
Humidity Level           : 46 % R.H.                                                                                Temperature: 24 ºC

Limits apply to          : FCC CFR 47, PART 15, SUBPART C, SECTION 15.209

Frequency Range          : 9 kHz ~ 30 MHz

Result                   : PASSED

EUT                      : HANDS3                                                                               Date: January 05, 2016

Operating Condition : Transmitting Mode

         Frequency               Reading         Ant. Pol. Ant. Factor           Cable           Emission         Limits        Margin
          (MHz)                   (dBμV)           (H/V)         (dB/m)          Loss         Level(dBμV/m)      (dBμV/m)        (dB)

           0.016                    12.6             H            19.00           0.1              31.70           123.52        91.82
           0.026                    13.2             H            19.40           0.1              32.70           119.30        86.60
           0.087                    18.8             H            19.40           0.1              38.30           108.81        70.51
           0.115                    29.7             H            19.40           0.1              49.21           106.39        57.18
           0.405                    24.1             H            19.40           0.1              43.63           95.46         51.83
           25.67                    33.1             H            20.30           0.8              54.20           70.00         15.80

-. Remark: “H” Horizontal, “V” Vertical
-. “*” Means Fundamental frequency
-. Emission Level [dBμV/m] = Reading [dBμV] + Ant. Factor [dB/m] + Cable Loss [dB]
-. Margin [dB] = Emission Level [dBμV/m] – Limit [dBμV/m]
-. Limit calculation: Limit at specified distance + 40log (300/3) = Limit + 80 dB for up to 0.49 MHz
                       Limit at specified distance + 40log (30/3) = Limit + 40 dB for above 0.49 MHz, Below 30 MHz




                                                                                            Tested by: Min-Gu, Ji / Project Engineer




It should not be reproduced except in full, without the written approval of ONETECH Corp.                                   EMC-003 (Rev.3)
HEAD OFFICE      : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)
EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904)


                                                                Page 18 of 19                          Report No. : OT-18D-RWD-014



9.5.2 Spurious Radiated Emission below 1 GHz
The following table shows the highest levels of radiated emissions on both polarizations of horizontal and vertical.

Humidity Level           : 46 % R.H.                                                                                Temperature: 24 ºC

Limits apply to          : FCC CFR 47, PART 15, SUBPART C, SECTION 15.209

Frequency range          : 30 MHz ~ 1 000 MHz

Result                   : PASSED

EUT                      : HANDS3                                                                               Date: September 18, 2018

Operating Condition : Transmitting Mode




                                                                                            Tested by: Min-Gu, Ji / Project Engineer
It should not be reproduced except in full, without the written approval of ONETECH Corp.                                  EMC-003 (Rev.3)
HEAD OFFICE      : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)
EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904)


                                                                Page 19 of 19                     Report No. : OT-18D-RWD-014


10. LIST OF TEST EQUIPMENT

 No.       EQUIPMENTS                     MFR.              MODEL               SER. NO.        LAST CAL            DUE CAL         USE

  1.                                       R/S                ESCI               101012        Oct. 22, 2018         One Year         
  2.         Test receiver                 R/S                ESR                101470        Oct. 22, 2018         One Year         
  3.                                       R/S              ESHS10             834467/007      Mar. 29, 2018         One Year         
  4.      Spectrum analyzer                R/S               FSV30               101372        Aug 23, 2018          One Year         
                                        Sonoma
  5.           Amplifier                                      310N               312544        Mar. 28, 2018         One Year         
                                       Instrument
                                        Sonoma
  6.           Amplifier                                      310N               312545        Mar. 28, 2018         One Year         
                                       Instrument
         TRILOG Broadband
  7.                                 Schwarzbeck          VULB9163              9163-255        Jun 05, 2018        Two Years         
                Antenna
  8.           Controller            Innco System           CO2000          619/27030611/L           N/A                N/A           

                                         EMCO                3825/2             9109-1869      Apr. 11, 2018         One Year          -
  9.              LISN
                                     Schwarzbeck          NSLK8126              8126-404       Apr. 04, 2018         One Year         
                                     Schwarzbeck          NSLK8128              8128-216       Mar. 28, 2018         One Year         
 10.           Turn Table            Innco System           DT3000               930611              N/A                N/A           
 11.        Antenna Master           Innco System         MA4000-EP           MA4000/332             N/A                N/A           
 12.        Antenna Master           Innco System         MA4000-EP           MA4000/335             N/A                N/A           
 13.     Triple Loop Antenna         Schwarzbeck          HXYZ 9170         HFCD 9171-207      Sep. 25, 2017        Two Years         
 14.      Frequency Counter                HP               53152A            US39270295       Aug. 23, 2018         One Year         
  15         Loop Antenna            Schwarzbeck          FMZB 1513             1513-235       May. 13, 2018        Two Years         




It should not be reproduced except in full, without the written approval of ONETECH Corp.                                  EMC-003 (Rev.3)
HEAD OFFICE      : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)
EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904)



Document Created: 2019-03-26 10:08:00
Document Modified: 2019-03-26 10:08:00

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC