Test report

FCC ID: 2AQE4FLYTEC2008

Test Report

Download: PDF
FCCID_4196800

                             Global United Technology Services Co., Ltd.

                                                                                  Report No.: GTS201811000082F01
Cover Page

                               FCC REPORT
    Applicant:                        Shantou Flying Technology Inc.

    Address of Applicant:             Room 406, North 4F, Building No.6, Polyacer E-commerce
                                      Industrial Centre, No.283 Nanao Rd, Jinping Industrial,
                                      Shantou, China
    Manufacturer:                     Shantou Flying Technology Inc.

    Address of                        Room 406, North 4F, Building No.6, Polyacer E-commerce
    Manufacturer:                     Industrial Centre, No.283 Nanao Rd, Jinping Industrial,
                                      Shantou, China
    Equipment Under Test (EUT)

      Product Name:                   Remote control boat series

      Model No.:                      See section 5.1

    FCC ID:                           2AQE4FLYTEC2008

    Applicable standards:             FCC CFR Title 47 Part 15 Subpart C Section 15.231

    Date of sample receipt:           November 30, 2018

    Date of Test:                     December 03, 2018-March 04, 2019

    Date of report issued:            March 04, 2019

    Test Result :                     PASS *

*     In the configuration tested, the EUT complied with the standards specified above.




    Authorized Signature:




      Robinson Lo
Laboratory Manager
This results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in
full, without prior written permission of the company. The report would be invalid without specific stamp of test institute
and the signatures of compiler and approver.


                                                                               Report No.: GTS201811000082F01



2     Version
    Version No.                        Date                                     Description
          01                     March 04, 2019                                   Original




Prepared By:                                                       Date:                March 04, 2019

                                     Project Engineer



Check By:                                                          Date:                March 04, 2019

                                         Reviewer




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                  Page 2 of 32


                                                                                                              Report No.: GTS201811000082F01


3         Contents
                                                                                                                                                          Page
1       COVER PAGE ...........................................................................................................................................1

2       VERSION ...................................................................................................................................................2

3       CONTENTS ...............................................................................................................................................3

4       TEST SUMMARY ......................................................................................................................................4
    4.1         MEASUREMENT UNCERTAINTY .............................................................................................................4
5       GENERAL INFORMATION .......................................................................................................................5
    5.1         GENERAL DESCRIPTION OF EUT ..........................................................................................................5
    5.2         TEST MODE .........................................................................................................................................6
    5.3         DESCRIPTION OF SUPPORT UNITS ........................................................................................................6
    5.4         TEST FACILITY ....................................................................................................................................6
    5.5         TEST LOCATION ..................................................................................................................................6
    5.6         OTHER INFORMATION REQUESTED BY THE CUSTOMER..........................................................................6
6       TEST INSTRUMENTS LIST ......................................................................................................................7

7       TEST RESULTS AND MEASUREMENT DATA .......................................................................................8
    7.1     ANTENNA REQUIREMENT .....................................................................................................................8
    7.2     RADIATED EMISSION METHOD ..............................................................................................................9
       7.2.1 Field Strength of The Fundamental Signal ..................................................................................11
       7.2.2 Spurious Emissions.....................................................................................................................12
    7.3     20DB OCCUPY BANDWIDTH ...............................................................................................................15
    7.4     DWELL TIME .....................................................................................................................................16
    7.5     DUTY CYCLE .....................................................................................................................................17
8       TEST SETUP PHOTO .............................................................................................................................19

9       EUT CONSTRUCTIONAL DETAILS .......................................................................................................20




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                                                      Page 3 of 32


                                                                               Report No.: GTS201811000082F01

4      Test Summary
                Test Item                              Section in CFR 47                      Result
          Antenna Requirement                                 15.203                           Pass
          Conduction Emission                                 15.207                            N/A
Field strength of the Fundamental Signal                    15.231 (b)                         Pass
           Spurious Emissions                           15.231 (b)/15.209                      Pass
             20dB Bandwidth                                 15.231 (c)                         Pass
                Dwell Time                                15.231 (a)(1)                        Pass
Pass: The EUT complies with the essential requirements in the standard.


4.1    Measurement Uncertainty
            Test Item                      Frequency Range                Measurement Uncertainty        Notes
       Radiated Emission                     9kHz ~ 30MHz                           4.54dB               (1)
       Radiated Emission                   30MHz ~ 1000MHz                          5.34dB               (1)
       Radiated Emission                    1GHz ~ 26.5GHz                          5.34dB               (1)
    AC Power Line Conducted
                                           0.15MHz ~ 30MHz                          3.44dB               (1)
          Emission
    Note (1): The measurement uncertainty is for coverage factor of k=2 and a level of confidence of 95%.




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                               Page 4 of 32


                                                                               Report No.: GTS201811000082F01

5     General Information
5.1 General Description of EUT
      Product Name:                      Remote control boat series
      Model No.:                         HQ2011-5, V001, V002, V003, V004, V005, V006, V007, V008, V009,
                                         V011, V022, V033, V055, V066, V077, V088, V099, V010, V020, V030,
                                         V050, V060, V070, V080, V090, V300, V500, V600, V700, V800, V900,
                                         V301, V302, V303, V305, V306, V307, V308, V309, V333, V555, V666,
                                         V777, V888, V999, HQ2011-1, HQ2011-2, HQ2011-3, HQ2011-6,
                                         HQ2011-7, HQ2011-8, HQ2011-9, HQ2011-10, HQ2011-15, HQ5010,
                                         HQ5011, HQ5012, HQ5013, H100, H101, H102, H103, H105, H106,
                                         H107, H108, H109, H110, H111, H112, H113, H115, H116, H117, H118,
                                         H119, H120
      Test Model No:                     HQ2011-5
      Remark: All above models are identical in the same PCB layout, interior structure and electrical circuits.
      The differences are color and model name for commercial purpose.
      Serial No.:                        TX:TX2018082001
                                         RX:RX2018092001
      Test sample(s) ID:                 GTS201811000082-1
      Sample(s) Status:                  Engineer sample
      Hardware Version:                  TX:TXHW2.00A
                                         RX:RXHW2.00A
      Software Version:                  TX:TXFW1.01F
                                         RX:RXFW1.00F
      Operation Frequency:               434MHz
      Modulation technology:             GFSK
      Antenna Type:                      Integral Antenna
      Antenna gain:                      1.0dBi(declare by applicant)
      Power supply:                      LI-ION CHARGER
                                         Model:YSN-84100
                                         Input: AC 100-240V, 50/60Hz
                                         Output: DC 8.4V, 1A
                                         Or
                                         Battery(RX): DC 7.4V, 5200mAh,
                                         Battery(TX): DC 6V (4*1.5V Size“AA” )




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                              Page 5 of 32


                                                                               Report No.: GTS201811000082F01


5.2 Test mode
     Transmitting mode              Keep the EUT in transmitting mode. (New battery is used during all test)


Per-test mode.
We have verified the construction and function in typical operation, The EUT was placed on three different polar
directions; i.e. X axis, Y axis, Z axis. which only the worst case was shown in this test report and defined as
follows:
                               Axis                        X                     Y                      Z
       434MHz                  Field
                                                        82.37                   82.85              81.43
                         Strength(dBuV/m)
5.3 Description of Support Units
      None.
5.4 Test Facility
      The test facility is recognized, certified, or accredited by the following organizations:
      ● FCC —Registration No.: 381383
      Global United Technology Services Co., Ltd., Shenzhen EMC Laboratory has been registered and fully
      described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter
      from the FCC is maintained in files. Registration 381383.
      ● Industry Canada (IC) —Registration No.: 9079A-2
      The 3m Semi-anechoic chamber of Global United Technology Services Co., Ltd. has been registered by
      Certification and Engineering Bureau of Industry Canada for radio equipment testing with Registration
      No.: 9079A-2.
      ● NVLAP (LAB CODE:600179-0)
      Global United Technology Services Co., Ltd., is accredited by the National Voluntary Laboratory
      Accreditation Program (NVLAP). LAB CODE:600179-0
      ● CNAS (No. CNAS L5775)
      CNAS has accredited Global United Technology Services Co., Ltd., to ISO/IEC 17025:2017 General
      Requirements for the Competence of Testing and Calibration Laboratories (CNAS-CL01 Accreditation
      Criteria for the Competence of Testing and Calibration Laboratories) for the competence in the field of
      testing.
5.5 Test Location
      All tests were performed at:
      Global United Technology Services Co., Ltd.
      No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
      Xixiang Road, Baoan District, Shenzhen, Guangdong, China
      Tel: 0755-27798480
      Fax: 0755-27798960
5.6 Other Information Requested by the Customer
      None.




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                              Page 6 of 32


                                                                                Report No.: GTS201811000082F01


6      Test Instruments list
Radiated Emission:
                                                                               Inventory     Cal.Date        Cal.Due date
Item      Test Equipment            Manufacturer            Model No.
                                                                                  No.       (mm-dd-yy)       (mm-dd-yy)
         3m Semi- Anechoic
 1                               ZhongYu Electron     9.2(L)*6.2(W)* 6.4(H)     GTS250     July. 03 2015    July. 02 2020
             Chamber
 2         Control Room        ZhongYu Electron 6.2(L)*2.5(W)* 2.4(H)           GTS251          N/A              N/A
 3       EMI Test Receiver     Rohde & Schwarz         ESU26                    GTS203     June. 27 2018    June. 26 2019
                               SCHWARZBECK
 4       BiConiLog Antenna                           VULB9163                   GTS214     June. 27 2018    June. 26 2019
                              MESS-ELEKTRONIK
           Double -ridged      SCHWARZBECK
 5                                                  BBHA 9120 D                 GTS208     June. 27 2018    June. 26 2019
           waveguide horn     MESS-ELEKTRONIK
6          Horn Antenna         ETS-LINDGREN             3160                   GTS217     June. 27 2018    June. 26 2019
7        EMI Test Software          AUDIX                 E3                     N/A            N/A              N/A
8          Coaxial Cable             GTS                  N/A                   GTS213     June. 27 2018    June. 26 2019
9          Coaxial Cable             GTS                  N/A                   GTS211     June. 27 2018    June. 26 2019
10          Coaxial cable            GTS                  N/A                   GTS210     June. 27 2018    June. 26 2019
11         Coaxial Cable             GTS                  N/A                   GTS212     June. 27 2018    June. 26 2019
12     Amplifier(100kHz-3GHz)         HP                8347A                   GTS204     June. 27 2018    June. 26 2019
13     Amplifier(2GHz-20GHz)          HP               84722A                   GTS206     June. 27 2018    June. 26 2019
                                                    AFS33-18002
14      Amplifier (18-26GHz)   Rohde & Schwarz                                  GTS218     June. 27 2018    June. 26 2019
                                                    650-30-8P-44
15           Band filter             Amindeon                 82346             GTS219     June. 27 2018    June. 26 2019
16         Power Meter                 Anritsu              ML2495A             GTS540     June. 27 2018    June. 26 2019
17        Power Sensor                 Anritsu              MA2411B             GTS541     June. 27 2018    June. 26 2019
         Wideband Radio
18                               Rohde & Schwarz            CMW500              GTS575     June. 27 2018    June. 26 2019
       Communication Tester
19            Splitter                 Agilent              11636B              GTS237     June. 27 2018    June. 26 2019
20        Loop Antenna                ZHINAN               ZN30900A             GTS534     June. 27 2018    June. 26 2019
            Breitband
21                               SCHWARZBECK               BBHA 9170            GTS579     Oct. 20 2018     Oct. 19 2019
           horn antenna
22           Amplifier                  TDK                 PA-02-02            GTS574     Oct. 20 2018     Oct. 19 2019
23           Amplifier                  TDK                 PA-02-03            GTS576     Oct. 20 2018     Oct. 19 2019
       PSA Series Spectrum
24                               Rohde & Schwarz              FSP               GTS578     June. 27 2018    June. 26 2019
             Analyzer



General used equipment:
                                                                                             Cal.Date       Cal.Due date
Item      Test Equipment            Manufacturer           Model No.      Inventory No.
                                                                                            (mm-dd-yy)      (mm-dd-yy)
       Humidity/ Temperature
 1                                      KTJ                 TA328              GTS243      June. 27 2018    June. 26 2019
             Indicator
 2           Barometer              ChangChun               DYM3               GTS255      June. 27 2018    June. 26 2019




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                  Page 7 of 32


                                                                                Report No.: GTS201811000082F01


7      Test results and Measurement Data
7.1 Antenna Requirement
      Standard requirement:            FCC Part15 C Section 15.203
       15.203 requirement:
       An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
       responsible party shall be used with the device. The use of a permanently attached antenna or of an
       antenna that uses a unique coupling to the intentional radiator, the manufacturer may design the unit so
       that a broken antenna can be replaced by the user, but the use of a standard antenna jack or electrical
       connector is prohibited.
      EUT Antenna:

        The antenna is integral antenna, the best case gain of the antenna is 1.0dBi




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                               Page 8 of 32


                                                                               Report No.: GTS201811000082F01


7.2 Radiated Emission Method
      Test Requirement:                FCC Part15 C Section 15.231 (b)& Section 15.209
      Test Method:                     ANSI C63.10:2013
      Test Frequency Range:            9kHz to 5000MHz
      Test site:                       Measurement Distance: 3m
      Receiver setup:                       Frequency            Detector         RBW          VBW            Value
                                          9KHz-150KHz           PK,AV,QP         200Hz         600Hz      PK,AV,QP
                                          150KHz-30MHz          PK,AV,QP          9KHz         30KHz      PK,AV,QP
                                           30MHz-1GHz           Quasi-peak      120KHz     300KHz         Quasi-peak
                                                                   Peak          1MHz          3MHz           Peak
                                           Above 1GHz
                                                                   Peak          1MHz   10Hz      Average
      Limit:                                     Frequency             Limit (dBuV/m @3m)       Remark
                                                                               100.83         Peak Value
      (Field strength of the                    434MHz
      fundamental signal)                                                       80.83        Average Value

      Limit:                                                                                         Field Strength of
                                                                           Field Strength of
                                         Fundamental Frequency                                          Unwanted
      (Spurious Emissions)                                                   fundamental
                                                (MHz)                                                   Emissions
                                                                          (microvolts/meter)
                                                                                                    (microvolts/meter)
                                                40.66-40.70                      1,000                      100
                                                   70-130                         500                        50
                                                  130-174                    500 to 1,500**            50 to 1,50**
                                                  174-260                        1,500                     1,50
                                                  260-470                   1,500 to 5,000**          1,50 to 5,00**
                                                 Above 470                       5,000                     5,00

                                                 Frequency                  Class B(dBuV/m @3m)
                                                   (MHz)                   Peak                  Average
                                                Above 1000                  74                      54
                                       Or The maximum permitted unwanted emission level is 20 dB below the
                                       maximum permitted fundamental level whichever limit permits a higher field
                                       strength.
      Test setup:                      Below 30MHz




                                       Below 1GHz




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                    Page 9 of 32


                                                                               Report No.: GTS201811000082F01




                                       Above 1GHz




      Test Procedure:                  1. The EUT was placed on the top of a rotating table (0.8 meters for below
                                          1GHz and 1.5 meters for above 1GHz) above the ground at a 3 meter
                                          camber. The table was rotated 360 degrees to determine the position of
                                          the highest radiation.
                                       2. The EUT was set 3 meters away from the interference-receiving
                                          antenna, which was mounted on the top of a variable-height antenna
                                          tower.
                                       3. The antenna height is varied from one meter to four meters above the
                                          ground to determine the maximum value of the field strength. Both
                                          horizontal and vertical polarizations of the antenna are set to make the
                                          measurement.
                                       4. For each suspected emission, the EUT was arranged to its worst case
                                          and then the antenna was tuned to heights from 1 meter to 4 meters
                                          and the rota table was turned from 0 degrees to 360 degrees to find the
                                          maximum reading.
                                       5. The test-receiver system was set to Peak Detect Function and Specified
                                          Bandwidth with Maximum Hold Mode.
                                       6. If the emission level of the EUT in peak mode was 10dB lower than the
                                          limit specified, then testing could be stopped and the peak values of the
                                          EUT would be reported. Otherwise the emissions that did not have 10dB
                                          margin would be re-tested one by one using peak, quasi-peak or
                                          average method as specified and then reported in a data sheet.
      Test Instruments:                Refer to section 6.0 for details
      Test mode:                       Refer to section 5.2 for details
      Test results:                    Pass


Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 10 of 32


                                                                               Report No.: GTS201811000082F01
Measurement data:
7.2.1   Field Strength of The Fundamental Signal

Peak value:
                 Read        Antenna      Cable      Preamp                                       Over
Frequency                                                           Level        Limit Line
                 Level        Factor      Loss        Factor                                      Limit        polarization
  (MHz)                                                           (dBuV/m)       (dBuV/m)
                (dBuV)        (dB/m)       (dB)        (dB)                                       (dB)
  434.00         86.52         17.53      3.02        29.43         77.64         100.83         -23.19        Horizontal
  434.00         91.73         17.53      3.02        29.43         82.85         100.83         -17.98         Vertical
Average value:
                                                       Average
 Frequency        Peak Value        Duty cycle                         Limit Line        Over Limit
                                                        value                                              Polarization
   (MHz)           (dBuV/m)           factor                           (dBuV/m)            (dB)
                                                      (dBuV/m)
   434.00            77.64             -17.68           59.96            80.83                -20.87           Horizontal
   434.00            82.85             -17.68           65.17            80.83                -15.66            Vertical

Remarks:
1. Final Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor
2. Average value=Peak value + Duty cycle factor




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                    Page 11 of 32


 GTS
                                                                                            Report No.: GTS201811000082F01

7.2.2         Spurious Emissions


Measurement data:
9 kHz ~ 30 MHz
The low frequency, which started from 9 kHz to 30 MHz, was pre—scanned and the result which was 20 dB
lower than the limit line per 15.31(0) was not reported.


Below 1GHz:

 Mode:                       Transmitting mode                                         Test by:                 Bill
 Temp./Hum.(%H):             26 °C/56%RH                                               Polarziation:            Horizontal



        Level (dBuVim)
8
8=
  o
H%HES




  10
                                                                                                  m
        30          50                     100                     200                            500                      1000
                                                       Frequency (MHz)

             Freq   Reading      Antenna     Cable        Preanp                       Limit      Over
                    level        factor      loss         factor         level         level      limit          Remark
             MHz      dBu¥        dB/m       dB            dB             dBu¥          dBu¥/m       dB

         40. 988    38. 77        12. 21       0. 67      35. 72         15. 93        40. 00     —24. 07          QP
         55. 221    37. 64        11. 78       0. 82      36. 26         13. 98        40. 00     —26. 02          QP
         95. 427    36. 58        11. 52       1.16       36. 68         12. 58        43. 50     —30. 92          qP
        216. 024    49. 80        11. 02      1. 93       37. 35         25. 40        46. 00     —20. 60          qP
        338.400     39. 14        14. 31      2. 57       37. 46         18. 56        46. 00     —27. 44           qP
        868.130     62. 51        22. 02      4.73        37. 61         51. 65        80. 83     —29.18           Feak



Average value:
 Frequency          Peak Level         Duty cycle          Azglrjge               Limit Line      Over Limit            Polarization
     (MHz)           (dBuV/m)              factor          (dBuV/im)              (dBuV/m)              (dB)

  868.130                51.65             —17.68           33.97                   60.83              —26.86             Horizontal



Global United Technology Services Co., Ltd.
No. 301—309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Bacan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                              Page 12 of 32


 GTS
                                                                                           Report No.: GTS201811000082F01



 Mode:                      Transmitting mode                                         Test by:                 Bill
 Temp./Hum.(%H):            26 °C/56%RH                                               Polarziation:            Vertical


     mLe‘vel{dBqu]


     80

     T70

     60


     so                                                                                                                               [
     m—,—l




     ®
                                                                                                                      5            \tw



     10


           30          50                  100                       200                               500                          1000
                                                       Frequency (MHz)

                Freq   Reading   Antenna      Cable       Preanp                           Limit       Over
                       level     factor       loss        factor           level           level       limit              Remark
                 MHz     dBu¥     dB/m        dB           dB               dBuy            dBu¥/m           dB
            40.988     39.02      12. 21       0. 67      35.   72         16.   18        40.   00    —23.02               qP
            96. 199    37. 46     11. 65       1.16       36.   69         13.   58        43.   50    —29.92               qP
           204. 238    38. 49     10. 58       1. 86      37.   33         14.   60        43.   50    —28. 90             qP
           338. 400    37. 00     14. 31       2.57       37.   46         16.   42        46.   00    —29.58              qP
           654.232     36. 07     19. 55       3 .93      37. 59           21. 96          46. 00      —24. 04             qP
           868.130     66. 47     22. 02       4 73       37. 61           55. 61          80. 83      —25. 22             Peak



Average value:

 mema® fegumd Cote                                        Cveme                  UMWLNQ |5im moerzaton
                                                        Average                  id    i                     h

                                                        (dBuV/m)
  868.130              55.61          —17.68              37.93                   60.83               —22.90                     Vertical




Global United Technology Services Co., Ltd.
No. 301—309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Bacan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                             Page 13 of 32


                                                                               Report No.: GTS201811000082F01

Above 1G:
Peak value:
               Read           Antenna       Cable      Preamp                                     Over
Frequency                                                             Level       Limit Line
               Level           Factor       Loss        Factor                                    Limit      Polarization
  (MHz)                                                             (dBuV/m)      (dBuV/m)
             (dBuV)            (dB/m)        (dB)        (dB)                                     (dB)
 1736.00       67.21            25.05       4.82        34.00         63.08          80.83       -17.75        Vertical
 2170.00       55.36            27.74       5.15        34.27         53.98          80.83       -26.85        Vertical
 2604.00       53.73            27.82       5.58        33.78         53.35          80.83       -27.48        Vertical
 1736.00       65.45            25.05       4.82        34.00         61.32          80.83       -19.51       Horizontal
 2170.00       54.08            27.74       5.15        34.27         52.70          80.83       -28.13       Horizontal
 2604.00       52.97            27.82       5.58        33.78         52.59          80.83       -28.24       Horizontal
Average value:
                                                        Average
 Frequency           Level           Duty cycle                         Limit Line       Over Limit
                                                         value                                               Polarization
   (MHz)           (dBuV/m)            factor                           (dBuV/m)           (dB)
                                                       (dBuV/m)
   1736.00            63.08             -17.68           45.40            60.83              -15.43           Vertical
   2170.00            53.98             -17.68           36.30            60.83              -24.53           Vertical
   2604.00            53.35             -17.68           35.67            60.83              -25.16           Vertical
   1736.00            61.32             -17.68           43.64            60.83              -17.19          Horizontal
   2170.00            52.70             -17.68           35.02            60.83              -25.81          Horizontal
   2604.00            52.59             -17.68           34.91            60.83              -25.92          Horizontal

Remarks:
1. Final Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor
2. Average value=Peak value + Duty cycle factor




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                  Page 14 of 32


                                                                               Report No.: GTS201811000082F01

7.3 20dB Occupy Bandwidth
      Test Requirement:               FCC Part15 C Section 15.231 (c)
      Test Method:                    ANSI C63.10:2013
      Limit:                          The bandwidth of the emission shall be no wider than 0.25% of the center
                                      frequency for devices operating above 70 MHz and below 900MHz. For
                                      devices operating above 900 MHz, the emission shall be no wider than
                                      0.5% of the center frequency. Bandwidth is determined at the points 20 dB
                                      down from the modulated carrier.
      Test setup:




      Test Instruments:               Refer to section 6.0 for details
      Test mode:                      Refer to section 5.2 for details
      Test results:                   Pass


Measurement Data
 Test Frequency (MHz)            20dB bandwidth (MHz)                    Limit (MHz)               Result
          434.00                           0.129                           1.085                    Pass
Note: Limit= Fundamental frequency×0.25%
434×0.25%=1.085MHz


Test plot as follows:




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 15 of 32


                                                                                Report No.: GTS201811000082F01


7.4 Dwell Time
      Test Requirement:               FCC Part15 C Section 15.231 (a)(1)
      Test Method:                    ANSI C63.10:2013
      Receiver setup:                 RBW=100KHz, VBW=100KHz, span=0Hz, detector: Peak
      Limit:                          Not more than 5 seconds
      Test setup:




      Test Instruments:               Refer to section 6.0 for details
      Test mode:                      Refer to section 5.2 for details
      Test results:                   Pass




Measurement data:
     Frequency                   Duration of each TX                   Limit
                                                                                                 Result
       (MHz)                          (second)                       (second)
       434.00                            2.2                           <5.0                       Pass


Test plot as follows:




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                              Page 16 of 32


                                                                               Report No.: GTS201811000082F01

7.5 Duty Cycle
      Test Requirement:               FCC Part15 C Section 15.231
      Test Method:                    ANSI C63.10:2013
      Receiver setup:                 RBW=100KHz, VBW=100KHz, span=0Hz, detector: Peak
      Limit:                          No dedicated limit specified in the Rules.
      Test Procedure:                 1. Place the EUT on the table and set it in transmitting mode.
                                      2. Remove the antenna from the EUT and then connect a low loss RF
                                      cable from the antenna port to the spectrum analyzer.
                                      3. Set centre frequency of spectrum analyzer=operating frequency.
                                      4. Set the spectrum analyzer as RBW=100kHz, VBW=100KHz,
                                      Span=0Hz, Adjust Sweep=100ms to obtain the “worst-case” pulse on time
                                      5. Repeat above procedures until all frequency measured was complete.
      Test setup:




      Test Instruments:               Refer to section 6.0 for details
      Test mode:                      Refer to section 5.2 for details
      Test results:                   Pass




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 17 of 32


                                                                               Report No.: GTS201811000082F01
Measurement data:
                        Duty cycle factor =20 log(Duty cycle)
Calculate Formula:
                        Duty cycle=on time/0.1 seconds or period, whichever is less
Test data:
                        T on time =6.333(ms)
                        T period =48.5(ms)
                        Duty cycle=6.333/48.5=13.06%
                        Duty cycle factor =20 log(0.1306)=-17.68


Test plot as follows:




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 18 of 32


 GTS
                                                                               Report No.: GT$201811000082F01


8     Test Setup Photo
       Radiated Emission




Global United Technology Services Co., Ltd.
No. 301—309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Bacan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 19 of 32


                                                                               Report No.: GTS201811000082F01


9     EUT Constructional Details




             TX




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 20 of 32


                                                                               Report No.: GTS201811000082F01




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 21 of 32


                                                                               Report No.: GTS201811000082F01




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 22 of 32


                                                                               Report No.: GTS201811000082F01




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 23 of 32


                                                                               Report No.: GTS201811000082F01




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 24 of 32


                                                                               Report No.: GTS201811000082F01




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 25 of 32


                                                                               Report No.: GTS201811000082F01


             RX




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 26 of 32


                                                                               Report No.: GTS201811000082F01




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 27 of 32


                                                                               Report No.: GTS201811000082F01




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 28 of 32


                                                                               Report No.: GTS201811000082F01




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 29 of 32


                                                                               Report No.: GTS201811000082F01




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 30 of 32


                                                                               Report No.: GTS201811000082F01




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 31 of 32


                                                                               Report No.: GTS201811000082F01




                                                   ------ End ------




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 32 of 32



Document Created: 2019-03-11 20:06:07
Document Modified: 2019-03-11 20:06:07

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC