EMC Test Report

FCC ID: 2AQ95-NIUV3LTE

Test Report

Download: PDF
FCCID_4105654

                                 Test Report No.: FV180823W003



                                                                      EMC TEST REPORT
      Applicant:                           Beijing Niu Technology Co., Ltd

                                           11F, Fangheng Times Center Block A (Lianluo Building), No. 10 Wangjing street,
      Address:
                                           Chaoyang, Beijing, China


      Manufacturer or
                                           NIU INTERNATIONAL CO., LTD.
      Supplier:

      Address:                             Lingxiang Road, WEZ, Wujin, Changzhou, Jiangsu Province, China


      Product:                             Smart central controller

      Brand Name:                          NIU

      Model Name:                          V3LTE

      FCC ID:                              2AQ95-NIUV3LTE

      Date of tests:                       Aug. 27, 2018 ~ Sep. 28, 2018

      The submitted sample of the above equipment has been tested for according to the requirements of the
      following standards:

            FCC Part 15, Subpart B, Class B
            ANSI C63.4:2014

      CONCLUSION: The submitted sample was found to COMPLY with the test requirement

                               Issued by Alex Chen                                                                                   Approved by Sam Tung
                           Engineer / Mobile Department                                                                            Manager / Mobile Department




                                     Date: Sep. 29, 2018                                                                                    Date: Sep. 29, 2018
      This report is governed by, and incorporates by reference, CPS Conditions of Service as posted at the date of issuance of this report at
      http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/and is intended for your exclusive use. Any copying or replication of this report to or for any other person
      or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results
      set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and
      expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon
      request for accredited tests. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty;
      provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute you
      unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents.




                                                             No.B102, Dazu Chuangxin Mansion, North of Beihuan                                       Tel: +86 755 8869 6566
BV 7Layers Communications
                                                             Avenue, North Area, Hi-Tech Industrial Park, Nanshan                                    Fax: +86 755 8869 6577
Technology (Shenzhen) Co. Ltd
                                                             District, Shenzhen51800, China                                                          Email: customerservice.dg@cn.bureauveritas.com
                                                                                                Page 1 of 17                                                                                 Report Version 1


                           Test Report No.: FV180823W003


                                                   TABLE OF CONTENTS
       RELEASE CONTROL RECORD ............................................................................................................... 3

       1      GENERAL INFORMATION ................................................................................................................ 4
           1.1      GENERAL DESCRIPTION OF EUT............................................................................................. 4
           1.2      SUMMARY OF TEST RESULTS .................................................................................................. 5
           1.3      MEASUREMENT UNCERTAINTY ............................................................................................... 5
           1.4      DESCRIPTION OF TEST MODES............................................................................................... 6
           1.5      DESCRIPTION OF SUPPORT UNITS ......................................................................................... 6
       2      EMISSION TEST ................................................................................................................................ 7
           2.1    RADIATED EMISSION MEASUREMENT .................................................................................... 7
             2.1.1   LIMITS OF RADIATED EMISSION MEASUREMENT ......................................................... 7
             2.1.2   TEST INSTRUMENTS.......................................................................................................... 8
             2.1.3   TEST PROCEDURE............................................................................................................. 9
             2.1.4   DEVIATION FROM TEST STANDARD .............................................................................. 10
             2.1.5   TEST SETUP .......................................................................................................................11
             2.1.6   EUT OPERATING CONDITIONS ....................................................................................... 12
             2.1.7   TEST RESULTS ................................................................................................................. 13
       3 APPENDIX A – MODIFICATIONS RECORDERS FOR ENGINEERING CHANGES TO THE EUT
       BY THE LAB ............................................................................................................................................ 17




                                                 No.B102, Dazu Chuangxin Mansion, North of Beihuan                   Tel: +86 755 8869 6566
BV 7Layers Communications
                                                 Avenue, North Area, Hi-Tech Industrial Park, Nanshan                Fax: +86 755 8869 6577
Technology (Shenzhen) Co. Ltd
                                                 District, Shenzhen51800, China                                      Email: customerservice.dg@cn.bureauveritas.com
                                                                            Page 2 of 17                                                             Report Version 1


                       Test Report No.: FV180823W003


                                  RELEASE CONTROL RECORD

         ISSUE NO.              REASON FOR CHANGE                                                          DATE ISSUED
         FV180823W003           Original release                                                           Sep. 29, 2018




                                    No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications
                                    Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
Technology (Shenzhen) Co. Ltd
                                    District, Shenzhen51800, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 3 of 17                                                 Report Version 1


                       Test Report No.: FV180823W003

         1 GENERAL INFORMATION
         1.1      GENERAL DESCRIPTION OF EUT
        PRODUCT                     Smart central controller

        BRAND NAME                  NIU
        MODEL NAME                  V3LTE
        NOMINAL VOLTAGE             30Vdc (adapter or host equipment)
                                    WCDMA                      BPSK/QPSK

        MODULATION TYPE             LTE                        QPSK/16QAM

                                    GPS/GLONASS                C/A code
                                                               1852.4MHz ~ 1907.6MHz(FOR WCDMA B2)
                                    WCDMA                      1712.4MHz ~ 1907.6MHz(FOR WCDMA B4)
                                                               826.4MHz ~ 846.6MHz (FOR WCDMA B5)
                                                               1850.7MHz ~ 1909.3MHz (FOR LTE Band2)
        OPERATING                   LTE                        1710.7MHz ~ 1754.3MHz (FOR LTE Band4)
        FREQUENCY                                              699.7MHZ ~ 715.3MHZ (FOR LTE Band12)
                                    GPS                        1575.42MHz

                                    Glonass                    1602MHz

        HW VERSION                  TRA01D12
        SW VERSION                  TRA01D14
        I/O PORTS                   Refer to user’s manual
        CABLE SUPPLIED              N/A
        ACCESSORY DEVICES Refer to note as below
       NOTE:
       1. For a more detailed features description, please refer to the manufacturer’s specifications or the user's
          manual.
       2. For the test results, the EUT had been tested with all conditions. But only the worst case was shown in
          test report.




                                   No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications
                                   Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
Technology (Shenzhen) Co. Ltd
                                   District, Shenzhen51800, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                         Page 4 of 17                                                 Report Version 1


                       Test Report No.: FV180823W003



          1.2      SUMMARY OF TEST RESULTS
       The EUT has been tested according to the following specifications:

                                APPLIED STANDARD: FCC Part 15, Subpart B

           Standard Section                 Test Item                   Result                    Remark

                                                                                   Meets Class B Limit
                                    Radiated Emission
                                                                        PASS       Minimum passing margin is
           FCC Part 15,       Test (30MHz ~ 1GHz)
                                                                                   -12.96dB at 487.87MHz
           Subpart B, Class B
                                                                                   Meets Class B Limit
           ANSI C63.4:2014    Radiated Emission
                                                                        PASS       Minimum passing margin is
                              Test (Above 1GHz)
                                                                                   -10.58dB at 4712MHz




          1.3      MEASUREMENT UNCERTAINTY
       Where relevant, the following measurement uncertainty levels have been estimated for
       tests performed on the EUT as specified in CISPR 16-4-2:

       This uncertainty represents an expanded uncertainty expressed at approximately the
       95% confidence level using a coverage factor of k=2.

                      MEASUREMENT                         FREQUENCY                  UNCERTAINTY

                                                         30MHz ~ 1GHz                     +/-3.26dB
                    Radiated emissions
                                                         1GHz ~ 18GHz                     +/-4.48dB




                                   No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications
                                   Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
Technology (Shenzhen) Co. Ltd
                                   District, Shenzhen51800, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                         Page 5 of 17                                                 Report Version 1


                         Test Report No.: FV180823W003


          1.4           DESCRIPTION OF TEST MODES
          Test
                                                                Test Condition
          Mode

                                                    Radiated emission test

              1         WCDMA B2 Idle+ DC Charge+ GPS RX
              2         WCDMA B5 Idle+ DC Charge+ Glonass Rx
              3         LTE B2 Idle+ DC Charge+ GPS RX
              4         LTE B4 Idle+ DC Charge+ Glonass Rx
              5         LTE B12 Idle+ DC Charge+ GPS RX
       NOTE:
       1. For radiated emission test, test mode 1 was the worst case and only this mode was presented in this
          report



          1.5           DESCRIPTION OF SUPPORT UNITS
       The EUT has been tested as an independent unit together with other necessary
       accessories or support units. The following support units or accessories were used to
       form a representative test configuration during the tests.

       FOR EMISSION TESTS
        NO.          PRODUCT             BRAND             MODEL NO.                SERIAL NO.                  FCC ID
         1          GPS Simulator         N/A                 N/A                      N/A                       N/A
         2            Adapter             N/A               MPA-630                    N/A                       N/A


        NO.                     SIGNAL CABLE DESCRIPTION OF THE ABOVE SUPPORT UNITS
          1       N/A
          2       N/A




                                      No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications
                                      Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
Technology (Shenzhen) Co. Ltd
                                      District, Shenzhen51800, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                            Page 6 of 17                                                 Report Version 1


                       Test Report No.: FV180823W003



         2 EMISSION TEST

       2.1      RADIATED EMISSION MEASUREMENT

       2.1.1        LIMITS OF RADIATED EMISSION MEASUREMENT
       TEST STANDARD: FCC Part 15, Subpart B (Section: 15.109)
       Emissions radiated outside of the specified bands, shall be according to the general
       radiated limits as following:

                                Radiated Emissions Limits at 10 meters (dBµV/m)
                                   FCC 15B/                FCC 15B /
         Frequencies                                                                CISPR 22,                CISPR 22,
                                   ICES-003,               ICES-003,
            (MHz)                                                                    Class A                  Class B
                                    Class A                 Class B
              30-88                   39                      29.5
              88-216                 43.5                     33.1                           40                     30
             216-230
                                      46.4                      35.6
             230-960
                                                                                             47                     37
            960-1000                 49.5                    43.5
           1000-3000               Avg: 49.5               Avg: 43.5               Not defined              Not defined
              3000+                Peak: 69.5              Peak: 63.5              Not defined              Not defined

                                Radiated Emissions Limits at 3 meters (dBµV/m)
                                   FCC 15B /               FCC 15B /
         Frequencies                                                                CISPR 22,                CISPR 22,
                                   ICES-003,               ICES-003,
            (MHz)                                                                    Class A                  Class B
                                    Class A                 Class B
              30-88                  49.5                      40
              88-216                  54                      43.5                       50.5                     40.5
             216-230
                                      56.9                       46
             230-960
                                                                                         57.5                     47.5
            960-1000                   60                        54
           1000-3000                                                                 Avg: 56                   Avg: 50
                                    Avg: 60                 Avg: 54                  Peak: 76                  Peak: 70
              3000+                 Peak: 80                Peak: 74                 Avg: 60                   Avg: 54
                                                                                     Peak: 80                  Peak: 74




                                      No.B102, Dazu Chuangxin Mansion, North of Beihuan       Tel: +86 755 8869 6566
BV 7Layers Communications
                                      Avenue, North Area, Hi-Tech Industrial Park, Nanshan    Fax: +86 755 8869 6577
Technology (Shenzhen) Co. Ltd
                                      District, Shenzhen51800, China                          Email: customerservice.dg@cn.bureauveritas.com
                                                            Page 7 of 17                                                  Report Version 1


                       Test Report No.: FV180823W003

       Frequency Range (For unintentional radiators)
           Highest frequency generated or used in the                         Upper frequency of measurement
            device or on which the device operates or                                   range (MHz)
                          tunes (MHz)
                                Below 1.705                                                  30
                                 1.705-108                                                  1000
                                  108-500                                                   2000
                                 500-1000                                                   5000
                                                                              th
                                                                             5 harmonic of the highest frequency
                                Above 1000
                                                                                 or 40GHz, whichever is lower

       NOTE: 1. The lower limit shall apply at the transition frequencies.
             2. Emission level (dBuV/m) = 20 log Emission level (uV/m).
             3. As shown in 15.35(b), for frequencies above 1000MHz, the field strength limits are based on
                average detector, however, the peak field strength of any emission shall not exceed the
                maximum permitted average limits, specified above by more than 20dB under any condition of
                modulation.
                4. QP detector shall be applied if not specified.



       2.1.2        TEST INSTRUMENTS

       Frequency range below1GHz
       Equipment            Manufacturer           Model No.  Serial No.                    Last Cal.       Next Cal.
       3m Semi-anechoic                                       Euroshieldpn-
                            ETS-LINDGREN           9m*6m*6m                                 Apr. 21,18      Apr. 20,19
       Chamber                                                CT0001143-1216
       Bilog Antenna        ETS-LINDGREN           3143B      00161965                      Nov. 26,16 Nov. 25,18
       MXE EMI Receiver KEYSIGHT                   N9038A-544 MY54450026                    Mar. 16,18 Mar. 15,19
       Signal Pre-Amplifier EMSI                   EMC 9135 980249                          Jul. 09,18 Jul. 08,19

       Frequency range above 1GHz
       Equipment          Manufacturer             Model No.    Serial No.        Last Cal.   Next Cal.
       3m Semi-anechoic                                         Euroshieldpn-
                          ETS-LINDGREN            9m*6m*6m                        Apr. 21,18 Apr. 20,19
       Chamber                                                  CT0001143-1216
       Horn Antenna       ETS-LINDGREN            3117          00168728          Nov. 10,16 Nov. 09,18
       MXE EMI Receiver KEYSIGHT                  N9038A-544 MY54450026           Mar. 16,18 Mar. 15,19
                                                  EMC
       Signal Pre-Amplifier EMSI                                980257            Jul. 09,18 Jul. 08,19
                                                  012645B
         NOTE: 1. The test was performed in 3m chamber.
                 2. The calibration interval of the above test instruments is 12 months or 24 months and the
                    calibrations are traceable to CEPREI/CHINA, GRGT/CHINA and NIM/CHINA.
                3. The FCC Site Registration No. is 525120.




                                     No.B102, Dazu Chuangxin Mansion, North of Beihuan        Tel: +86 755 8869 6566
BV 7Layers Communications
                                     Avenue, North Area, Hi-Tech Industrial Park, Nanshan     Fax: +86 755 8869 6577
Technology (Shenzhen) Co. Ltd
                                     District, Shenzhen51800, China                           Email: customerservice.dg@cn.bureauveritas.com
                                                           Page 8 of 17                                                   Report Version 1


                       Test Report No.: FV180823W003

       2.1.3        TEST PROCEDURE


       <Frequency Range below 1GHz>

       The basic test procedure was in accordance with ANSI C63.4:2014 (section 12).
       a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3
          meter semi-anechoic chamber room. The table was rotated 360 degrees to determine
          the position of the highest radiation.
       b. The EUT was set 3 meters away from the interference-receiving antenna, which was
          mounted on the top of a variable-height antenna tower.
       c. The height of antenna is varied from 1 meter to 4 meters above the ground to
          determine the maximum value of the field strength. Both horizontal and vertical
          polarizations of the antenna are set to make the measurement.
       d. For each suspected emission, the EUT was arranged to its worst case and then the
          antenna was tuned to heights from 1 meter to 4 meters and the rotatable table was
          turned from 0 degrees to 360 degrees to find the maximum reading.
       e. The test-receiver system was set to quasi-peak detect function and specified
          bandwidth with maximum hold mode when the test frequency is below 1GHz.

          NOTE:
          1. The resolution bandwidth of test receiver/spectrum analyzer is 120kHz for Quasi-peak detection
             (QP) at frequency below 1GHz.

          2. Emission level(dBuV/m)=Raw Value(dBuV) + Correction Factor(dB/m)
          3. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB) (if the raw value not
             contains the amplifier);

          4. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB) – Amplifier Gain(dB) (if the
             raw value contains the amplifier).

          5. Margin value = Emission level – Limit value.




                                   No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications
                                   Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
Technology (Shenzhen) Co. Ltd
                                   District, Shenzhen51800, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                         Page 9 of 17                                                 Report Version 1


                       Test Report No.: FV180823W003

       <Frequency Range above 1GHz>

         a. The EUT was placed on the top of a rotating table 0.8 meters above the ground
            at a 3 meter fully-anechoic chamber room. The table was rotated 360 degrees to
            determine the position of the highest radiation.
          b. The EUT was set 3 meters away from the interference-receiving antenna, which
             was mounted on the top of a variable-height antenna tower.
          c. The height of antenna is varied from one meter to four meters above the ground
             to determine the maximum value of the field strength. Both horizontal and
             vertical polarizations of the antenna are set to make the measurement. The bore
             sight should be used during the test above 1GHz.
         d. For each suspected emission, the EUT was arranged to its worst case and then
            the antenna was tuned to heights from 1 meter to 4 meters and the rotatable
            table was turned from 0 degrees to 360 degrees to find the maximum reading.
         e. The test-receiver system was set to peak and average detect function and
            specified bandwidth with maximum hold mode when the test frequency is above
            1 GHz
         NOTE:
          1. The resolution bandwidth of test receiver/spectrum analyzer is 120kHz for Quasi-peak detection (QP)
             at frequency below 1GHz.
          2. The resolution bandwidth is 1MHz and video bandwidth of test receiver/spectrum analyzer is 3MHz
             for Peak detection at frequency above 1GHz. The resolution bandwidth of test receiver/spectrum
             analyzer is 1 MHz and video bandwidth of test receiver/spectrum analyzer is 10Hz for Average
             detection (AV) at frequency above 1GHz.
          3. For measurement of frequency above 1000 MHz, the EUT was set 3 meters away from the receiver
             antenna.
          4. Emission level(dBuV/m)=Raw Value(dBuV) + Correction Factor(dB/m)
          5. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB) (if the raw value not contains
             the amplifier);
          6. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB) – Amplifier Gain(dB) (if the
             raw value contains the amplifier)
          7. Margin value = Emission level – Limit value.


       2.1.4        DEVIATION FROM TEST STANDARD

       No deviation.




                                   No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications
                                   Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
Technology (Shenzhen) Co. Ltd
                                   District, Shenzhen51800, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                       Page 10 of 17                                                  Report Version 1


                       Test Report No.: FV180823W003


       2.1.5        TEST SETUP

          <Frequency Range below 1GHz>
                                                                Ant. Tower
                                                                                           1-4m
                                                                                           Variable
                                               3m
               EUT&
               Support Units

                                         Turn Table

                   0.8m


                                             Ground Plane

                                              Test Receiver




          <Frequency Range above 1GHz>


                                                           Ant. Tower                     1-4m*
                                                                                          Variable
             EUT&                             3m                                               Bore Sight
            Support Units
                                 Turn
                                 Table
                                               Absorber

                0.8m


                                          Ground Plane

                                           Test Receiver

                                                                                                   Pre-amplifier



       * : depends on the EUT height and the antenna 3dB beamwidth both, refer to section 7.3
           of CISPR 16-2-3.




                                   No.B102, Dazu Chuangxin Mansion, North of Beihuan       Tel: +86 755 8869 6566
BV 7Layers Communications
                                   Avenue, North Area, Hi-Tech Industrial Park, Nanshan    Fax: +86 755 8869 6577
Technology (Shenzhen) Co. Ltd
                                   District, Shenzhen51800, China                          Email: customerservice.dg@cn.bureauveritas.com
                                                       Page 11 of 17                                                   Report Version 1


                       Test Report No.: FV180823W003



       2.1.6        EUT OPERATING CONDITIONS
          a. Turned on the power and connected of all equipment.
          b. EUT was operated according to the use type described in the manufacturer’s
              specifications or the user's manual.




                                   No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications
                                   Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
Technology (Shenzhen) Co. Ltd
                                   District, Shenzhen51800, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                       Page 12 of 17                                                  Report Version 1


                       Test Report No.: FV180823W003


       2.1.7        TEST RESULTS

                                 DC 30V
        TEST VOLTAGE                                                 FREQUENCY RANGE                    30-1000 MHz
                                 Input 120 Vac, 60 Hz
                                                                     DETECTOR FUNCTION
        ENVIRONMENTAL
                      23deg. C, 70 %RH                               & RESOLUTION                       Quasi-Peak, 120 kHz
        CONDITIONS
                                                                     BANDWIDTH

        TESTED BY                Vincent Chen


                                ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
                   EMISSION READ                                 ANTENNA CABLE PREAMP ANTENNA TABLE
         FREQ.                       LIMIT  MARGIN
                    LEVEL   LEVEL                                 FACTOR   LOSS FACTOR HEIGHT  ANGLE REMARK
         (MHz)                     (dBuV/m)  (dB)
                   (dBuV/m) (dBuV)                                 (dB /m)  (dB)  (dB)  (cm)  (Degree)
         138.64      21.06        47.9      43.5      -22.44        8.77        1.24     36.85          100           140           QP
         201.69      26.49       50.91      43.5      -17.01       10.67        1.45     36.54          100           270           QP
         266.68      26.86       48.63       46       -19.14       13.07        1.67     36.51          100           190           QP
         301.6       30.25       51.18       46       -15.75       13.85        1.72      36.5          100           230           QP
         383.08      24.71        42.9       46       -21.29       16.54        1.95     36.68          103           320           QP
         487.84      33.04        49.9       46       -12.96       17.89        2.18     36.93          100           150           QP

        REMARKS:        1. Peak detector quick scan is showed on the graph and final quasi-peak detector data is
                           measured corresponding to relevant limit and recorded in the data table.
                        2. Negative sign (-) in the margin column signify levels below the limit.
                        3. Frequency range scanned: 30MHz to 1000MHz.
                        4. Only emissions significantly above equipment noise floor are reported.




                                         No.B102, Dazu Chuangxin Mansion, North of Beihuan       Tel: +86 755 8869 6566
BV 7Layers Communications
                                         Avenue, North Area, Hi-Tech Industrial Park, Nanshan    Fax: +86 755 8869 6577
Technology (Shenzhen) Co. Ltd
                                         District, Shenzhen51800, China                          Email: customerservice.dg@cn.bureauveritas.com
                                                             Page 13 of 17                                                   Report Version 1


                       Test Report No.: FV180823W003

                                DC 30V
        TEST VOLTAGE                                                FREQUENCY RANGE                    30-1000 MHz
                                Input 120 Vac, 60 Hz
                                                                    DETECTOR FUNCTION
        ENVIRONMENTAL
                      23deg. C, 70 %RH                              & RESOLUTION                       Quasi-Peak, 120 kHz
        CONDITIONS
                                                                    BANDWIDTH

        TESTED BY               Vincent Chen


                                ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
                   EMISSION READ                                ANTENNA CABLE PREAMP ANTENNA TABLE
         FREQ.                       LIMIT  MARGIN
                    LEVEL   LEVEL                                FACTOR   LOSS FACTOR HEIGHT  ANGLE REMARK
         (MHz)                     (dBuV/m)  (dB)
                   (dBuV/m) (dBuV)                                (dB /m)  (dB)  (dB)  (cm)  (Degree)
         52.31       24.57      54.41       40       -15.43        6.8         0.73     37.37          100           200           QP
         75.59       22.69      51.17       40       -17.31        7.82         0.9     37.2           100           236           QP
         262.8       21.2       43.06       46        -24.8       12.98        1.67     36.51          100           100           QP
         305.48      26.09      46.88       46       -19.91       13.98        1.74     36.51          100           270           QP
         416.06      24.32      41.81       46       -21.68       17.24        2.03     36.76          100           290           QP
         478.14      27.39      44.34       46       -18.61        17.8        2.16     36.91          100           340           QP

        REMARKS:        1. Peak detector quick scan is showed on the graph and final quasi-peak detector data is
                           measured corresponding to relevant limit and recorded in the data table.
                        2. Negative sign (-) in the margin column signify levels below the limit.
                        3. Frequency range scanned: 30MHz to 1000MHz.
                        4. Only emissions significantly above equipment noise floor are reported.




                                        No.B102, Dazu Chuangxin Mansion, North of Beihuan       Tel: +86 755 8869 6566
BV 7Layers Communications
                                        Avenue, North Area, Hi-Tech Industrial Park, Nanshan    Fax: +86 755 8869 6577
Technology (Shenzhen) Co. Ltd
                                        District, Shenzhen51800, China                          Email: customerservice.dg@cn.bureauveritas.com
                                                            Page 14 of 17                                                   Report Version 1


                       Test Report No.: FV180823W003

                                    DC 30V
        TEST VOLTAGE                                                FREQUENCY RANGE                 1-18 GHz
                                    Input 120 Vac, 60 Hz
                                                                    DETECTOR FUNCTION
        ENVIRONMENTAL
                                    23deg. C, 70 %RH                & RESOLUTION                    Peak/Average, 1 MHz
        CONDITIONS
                                                                    BANDWIDTH
        TESTED BY                   Vincent Chen


                                ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
                   EMISSION READ                              ANTENNA CABLE PREAMP ANTENNA TABLE
         FREQ.                       LIMIT  MARGIN
                    LEVEL   LEVEL                              FACTOR   LOSS FACTOR HEIGHT  ANGLE REMARK
         (MHz)                     (dBuV/m)  (dB)
                   (dBuV/m) (dBuV)                              (dB /m)  (dB)  (dB)  (cm)  (Degree)
         2576   39.58    44.41      54       -14.42     33.06     8.48     46.37       100    300  Average
         2576   45.21    50.04      74       -28.79     33.06     8.48     46.37       100    300    Peak
         3516   38.44    41.01      54       -15.56     33.83     9.98     46.38       100     50  Average
         3516   50.91    53.48      74       -23.09     33.83     9.98     46.38       100     50    Peak
         4712   43.42    41.26      54       -10.58     36.34    12.21 46.39           100    120 Average
         4712   52.33    50.17      74       -21.67     36.34    12.21 46.39           100    120    Peak
        REMARKS: 1. Peak detector quick scan is showed on the graph and final quasi-peak detector data is
                     measured corresponding to relevant limit and recorded in the data table.
                  2. Negative sign (-) in the margin column signify levels below the limit.
                  3. Frequency range scanned: 1GHz to 18GHz.
                  4. Only emissions significantly above equipment noise floor are reported.




                                      No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications
                                      Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
Technology (Shenzhen) Co. Ltd
                                      District, Shenzhen51800, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 15 of 17                                                  Report Version 1


                       Test Report No.: FV180823W003

                                   DC 30V
        TEST VOLTAGE                                               FREQUENCY RANGE                 1-18 GHz
                                   Input 120 Vac, 60 Hz
                                                                   DETECTOR FUNCTION
        ENVIRONMENTAL
                                   23deg. C, 70 %RH                & RESOLUTION                    Peak/Average, 1 MHz
        CONDITIONS
                                                                   BANDWIDTH
        TESTED BY                  Vincent Chen


                                ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
                   EMISSION READ                             ANTENNA CABLE PREAMP ANTENNA TABLE
         FREQ.                       LIMIT  MARGIN
                    LEVEL   LEVEL                             FACTOR   LOSS FACTOR HEIGHT  ANGLE REMARK
         (MHz)                     (dBuV/m)  (dB)
                   (dBuV/m) (dBuV)                             (dB /m)  (dB)  (dB)  (cm)  (Degree)
         2136   37.16    43.27      54       -16.84     32.56     7.69     46.36       200    200  Average
         2136   45.02    51.13      74       -28.98     32.56     7.69     46.36       200    200    Peak
         3547   36.75    39.22      54       -17.25     33.88    10.03 46.38           100    147  Average
         3547   50.72    53.19      74       -23.28     33.88    10.03 46.38           100    147    Peak
         4218   42.81    43.03      54       -11.19     35.08    11.08 46.38           200    208  Average
         4218   52.14    52.36      74       -21.86     35.08    11.08 46.38           200    208    Peak
        REMARKS: 1. Peak detector quick scan is showed on the graph and final quasi-peak detector data is
                     measured corresponding to relevant limit and recorded in the data table.
                  2. Negative sign (-) in the margin column signify levels below the limit.
                  3. Frequency range scanned: 1GHz to 18GHz.
                  4. Only emissions significantly above equipment noise floor are reported.




                                     No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications
                                     Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
Technology (Shenzhen) Co. Ltd
                                     District, Shenzhen51800, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                         Page 16 of 17                                                  Report Version 1


                       Test Report No.: FV180823W003



         3 APPENDIX A – MODIFICATIONS RECORDERS FOR ENGINEERING
           CHANGES TO THE EUT BY THE LAB

       No any modifications were made to the EUT by the lab during the test.




       ---END---




                                   No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications
                                   Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
Technology (Shenzhen) Co. Ltd
                                   District, Shenzhen51800, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                       Page 17 of 17                                                  Report Version 1



Document Created: 2018-11-26 14:12:24
Document Modified: 2018-11-26 14:12:24

© 2024 FCC.report