15B REPORT

FCC ID: 2AQ3A-HM2X

Test Report

Download: PDF
FCCID_4472812

                          Shenzhen Zhongjian Nanfang Testing Co., Ltd.
                                                                                                  Report No: CCISE190710702

1        Cover Page

                                      FCC REPORT
Applicant:                                 Shenzhen VanTop Technology & Innovation Co., Ltd.

Address of Applicant:                      502, 5th Flr. BLDG 4, MinQi Technology Park, No. 65 Lishan
                                           Road, Taoyuan Street, Nanshan District, Shenzhen, China
Equipment Under Test (EUT)

    Product Name:                          1080P Smart Wi-Fi Security Camera

    Model No.:                             HM211, HM212, HM311, HM312, HM241, HM242, HM243,
                                           CA01, HMD2, HMA1, HMC1, HMB1
    Trade mark:                            HeimVision

FCC ID:                                    2AQ3A-HM2X

Applicable standards:                      FCC CFR Title 47 Part 15 Subpart B

Date of sample receipt:                    24 Jul., 2019

Date of Test:                              25 Jul., to 18 Sep., 2019

Date of report issued:                     19 Sep., 2019

Test Result:                               PASS *
  * In the configuration tested, the EUT complied with the standards specified above.




 Authorized Signature:




       Bruce Zhang
    Laboratory Manager
This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other
samples of the same product and does not permit the use of the CCIS product certification mark. The manufacturer should ensure that all
products in series production are in conformity with the product sample detailed in this report.

This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than that detailed in
the report, the manufacturer must ensure the new system complies with all relevant standards.

This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or
falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days
only.


                                                                                 Report No: CCISE190710702

2      Version
      Version No.                            Date                                  Description
             00                        19 Sep., 2019                                 Original




    Tested by:                                                           Date:          19 Sep., 2019

                                       Test Engineer

    Reviewed by:                                                         Date:          19 Sep., 2019

                                    Project Engineer




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                          Project No.: CCISE1907107
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                         Page 2 of 18


                                                                                                                            Report No: CCISE190710702

3         Contents
                                                                                                                                                                                 Page
1     COVER PAGE ................................................................................................................................................... 1
2     VERSION ........................................................................................................................................................... 2
3     CONTENTS ....................................................................................................................................................... 3
4     TEST SUMMARY .............................................................................................................................................. 4
5     GENERAL INFORMATION .............................................................................................................................. 5
    5.1    CLIENT INFORMATION ...................................................................................................................................................... 5
    5.2    GENERAL DESCRIPTION OF E.U.T. ...................................................................................................................................... 5
    5.3    TEST MODE.................................................................................................................................................................... 5
    5.4    MEASUREMENT UNCERTAINTY ........................................................................................................................................... 5
    5.5    DESCRIPTION OF SUPPORT UNITS ....................................................................................................................................... 6
    5.6    RELATED SUBMITTAL(S) / GRANT (S) ................................................................................................................................... 6
    5.7    DESCRIPTION OF CABLE USED ............................................................................................................................................ 6
    5.8    LABORATORY FACILITY ...................................................................................................................................................... 6
    5.9    LABORATORY LOCATION ................................................................................................................................................... 6
    5.10      TEST INSTRUMENTS LIST ............................................................................................................................................... 7
6     TEST RESULTS AND MEASUREMENT DATA ............................................................................................. 8
    6.1    CONDUCTED EMISSION ..................................................................................................................................................... 8
    6.2    RADIATED EMISSION ...................................................................................................................................................... 11
7     TEST SETUP PHOTO..................................................................................................................................... 17
8     EUT CONSTRUCTIONAL DETAILS.............................................................................................................. 18




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                                               Project No.: CCISE1907107
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                                                                        Page 3 of 18


                                                                              Report No: CCISE190710702

4      Test Summary
                 Test Item                                Section in CFR 47                 Result
           Conducted Emission                                 Part 15.107                    Pass
            Radiated Emission                                 Part 15.109                    Pass
 Remark:
 Pass: The EUT complies with the essential requirements in the standard.
 N/A: The EUT not applicable of the test item.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                       Project No.: CCISE1907107
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                      Page 4 of 18


                                                                               Report No: CCISE190710702

5      General Information
5.1 Client Information
        Applicant:                              Shenzhen VanTop Technology & Innovation Co., Ltd.
        Address:                                502, 5th Flr. BLDG 4, MinQi Technology Park, No. 65 Lishan
                                                Road, Taoyuan Street, Nanshan District, Shenzhen, China
        Manufacturer:                           Shenzhen VanTop Technology & Innovation Co., Ltd.
        Address:                                502, 5th Flr. BLDG 4, MinQi Technology Park, No. 65 Lishan
                                                Road, Taoyuan Street, Nanshan District, Shenzhen, China

5.2 General Description of E.U.T.
        Product Name:                           1080P Smart Wi-Fi Security Camera
        Model No.:                              HM211, HM212, HM311, HM312, HM241, HM242, HM243, CA01,
                                                HMD2, HMA1, HMC1, HMB1
                                                Model: JK120100-S37USVD
        AC adapter :                            Input: AC100-240V, 50/60Hz, 0.5A
                                                Output: DC 12.0V, 1.0A
        Test Sample Condition:                  The test samples were provided in good working order with no
                                                visible defects.
    Remark:                                     The No.: HM211, HM212, HM311, HM312, HM241, HM242,
                                                HM243, CA01, HMD2, HMA1, HMC1, HMB1 were identical inside,
                                                the electrical circuit design, layout, components used and internal
                                                wiring, with only difference being model name.

5.3 Test Mode
           Operating mode               Detail description
          Recording mode              Keep the EUT in Recording mode (Worst case)
 The sample was placed 0.8m above the ground plane of 3m chamber. Measurements in both horizontal and
 vertical polarities were performed. During the test, each emission was maximized by: having the EUT
 continuously working, investigated all operating modes, rotated about all 3 axis (X, Y & Z) and considered
 typical configuration to obtain worst position, manipulating interconnecting cables, rotating the turntable,
 varying antenna height from 1m to 4m in both horizontal and vertical polarizations. The emissions worst-case
 are shown in Test Results of the following pages.

5.4 Measurement Uncertainty
                    Parameters                                              Expanded Uncertainty
        Conducted Emission (9kHz ~ 30MHz)                                      ±1.60 dB (k=2)
         Radiated Emission (9kHz ~ 30MHz)                                      ±3.12 dB (k=2)
       Radiated Emission (30MHz ~ 1000MHz)                                     ±4.32 dB (k=2)
        Radiated Emission (1GHz ~ 18GHz)                                       ±5.38 dB (k=2)
        Radiated Emission (18GHz ~ 40GHz)                                      ±3.36 dB (k=2)




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                            Project No.: CCISE1907107
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                            Page 5 of 18


c c I s                                                                         Report No: CCISE190710702



5.5 Description of Support Units
    Manufacturer            Description                 Model             Serial Number             FCC ID/DoC

        Lenovo                   PC                ThinkPad E450         PF—OKTSQQ 16/06                DoC


5.6 Related Submittal(s) / Grant (s)
       This is an original grant, no related submittals and grants.

5.7 Description of Cable Used
       N/A


5.8 Laboratory Facility
       The test facility is recognized, certified, or accredited by the following organizations:
        ® FCC — Designation No.: CN1211
       Shenzhen Zhongiian Nanfang Testing Co., Ltd. has been accredited as a testing laboratory by
       FCC(Federal Communications Commission). The test firm Registration No. is 727551.
        @ ISED — CAB identifier.: CNOO21
       The 3m Semi—anechoic chamber of Shenzhen Zhongiian Nanfang Testing Co., Ltd. has been
       Registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with
       Registration No.: 10106A—1.
        ©@ CNAS — Registration No.: CNAS L6048
       Shenzhen Zhongiian Nanfang Testing Co., Ltd. is accredited to ISO/IEC 17025:2005 General
       Requirements for the Competence of Testing and Calibration laboratories for the competence of
       testing. The Registration No. is CNAS L6048.
       ®     A2LA — Registration No.: 4346.01
        This laboratory is accredited in accordance with the recognized International Standard ISO/IEC
        17025:2005 General requirements for the competence of testing and calibration laboratories. The test
        scope can be found as below link: https://portal.a2la.org/scopepdt/4346—01.pdf

5.9 Laboratory Location
       Shenzhen Zhongjian Nanfang Testing Co., Ltd.
       Address: No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
       Bac‘an District, Shenzhen, Guangdong, China
       Tel: +86—755—23118282, Fax: +86—755—23116366
        Email: info@ccis—cb.com, Website: http//www.ccis—cb.com




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                             Project No.: CCISE1907107
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                            Page 6 of 18


                                                                                  Report No: CCISE190710702

5.10 Test Instruments list
 Radiated Emission:
                                                                                            Cal. Date       Cal. Due date
    Test Equipment            Manufacturer            Model No.           Serial No.
                                                                                          (mm-dd-yy)         (mm-dd-yy)
        3m SAC                  SAEMC                 9m*6m*6m                966          07-22-2017         07-21-2020
     Loop Antenna            SCHWARZBECK             FMZB1519B              00044          03-18-2019         03-17-2020
   BiConiLog Antenna         SCHWARZBECK              VULB9163                497          03-18-2019         03-17-2020
     Horn Antenna            SCHWARZBECK             BBHA9120D                916          03-18-2019         03-17-2020
     Horn Antenna            SCHWARZBECK             BBHA9120D               1805          06-22-2017         06-21-2020
     Horn Antenna            SCHWARZBECK             BBHA 9170           BBHA9170582      11-21-2018         11-20-2019
   EMI Test Software             AUDIX                   E3                            Version: 6.110919b
     Pre-amplifier                 HP                  8447D             2944A09358       03-18-2019         03-17-2020
     Pre-amplifier                 CD                 PAP-1G18              11804         03-18-2019         03-17-2020
   Spectrum analyzer         Rohde & Schwarz           FSP30               101454         03-18-2019         03-17-2020
   Spectrum analyzer         Rohde & Schwarz           FSP40               100363         11-21-2018         11-20-2019
   EMI Test Receiver         Rohde & Schwarz           ESRP7                101070        03-18-2019         03-17-2020
        Cable                    ZDECL              Z108-NJ-NJ-81          1608458        03-18-2019         03-17-2020
        Cable                 MICRO-COAX              MFR64639             K10742-5       03-18-2019         03-17-2020
        Cable                   SUHNER              SUCOFLEX100           58193/4PE       03-18-2019         03-17-2020


 Conducted Emission:
                                                                                          Cal. Date         Cal. Due date
   Test Equipment            Manufacturer             Model No.           Serial No.
                                                                                        (mm-dd-yy)           (mm-dd-yy)
  EMI Test Receiver         Rohde & Schwarz             ESCI               101189        03-18-2019           03-17-2020
    Pulse Limiter           SCHWARZBECK              OSRAM 2306             9731         03-18-2019           03-17-2020
        LISN                    CHASE                 MN2050D               1447         03-18-2019           03-17-2020
        LISN                Rohde & Schwarz           ESH3-Z5            8438621/010     07-21-2018           07-20-2021
       Cable                      HP                   10503A                N/A         03-18-2019           03-17-2020
  EMI Test Software             AUDIX                    E3                          Version: 6.110919b




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                Project No.: CCISE1907107
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                  Page 7 of 18


                                                                              Report No: CCISE190710702

6      Test results and Measurement Data
6.1 Conducted Emission
       Test Requirement:                FCC Part 15 B Section 15.107
       Test Method:                     ANSI C63.4:2014
       Test Frequency Range:            150kHz to 30MHz
       Class / Severity:                Class B                  Class B
       Receiver setup:                  RBW=9kHz, VBW=30kHz
       Limit:                                                                        Limit (dBµV)
                                          Frequency range (MHz)
                                                                          Quasi-peak                Average
                                                 0.15-0.5                   66 to 56*               56 to 46*
                                                   0.5-5                       56                      46
                                                  0.5-30                       60                      50
                                        * Decreases with the logarithm of the frequency.
       Test setup:




       Test procedure                   1. The E.U.T and simulators are connected to the main power through a
                                           line impedance stabilization network(L.I.S.N.). The provide a
                                           50ohm/50uH coupling impedance for the measuring equipment.
                                        2. The peripheral devices are also connected to the main power through a
                                           LISN that provides a 50ohm/50uH coupling impedance with 50ohm
                                           termination. (Please refers to the block diagram of the test setup and
                                           photographs).
                                        3. Both sides of A.C. line are checked for maximum conducted
                                           interference. In order to find the maximum emission, the relative
                                           positions of equipment and all of the interface cables must be changed
                                           according to ANSI C63.4: 2014 on conducted measurement.
       Test Instruments:                Refer to section 5.10 for details
       Test mode:                       Refer to section 5.3 for details
       Test results:                    Pass




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                           Project No.: CCISE1907107
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                            Page 8 of 18


CCIS                                                                                                                 Report No: CCISE190710702

Measurement data:
 Product name:                                        1080P Smart Wi—Fi Security Camera             Product model:           HM211

Test by:                                              Yaro                                          Test mode:               Recording mode

Test frequency:                                       150 kHz ~ 30 MHz                              Phase:                   Line

Test voltage:                                         AC 120 V/60 Hz                                Environment:             Temp: 22.5°C           Huni: 55%


           80 Level (dBuV)


           70

           60\                                                                                                                         FCC PART15 B OP

           50                     s                                                                                                    FCC PART15B AV
                AH                            T


           40        \
                                  l@-‘                  Mi N                                                 \
                                                                                                                      |
           0/ —/f                        4)                                                   4
           20            h\I[ W                   |                         lucalt
                                                                            |             } *,f                                                        f
                                                                                 "                                                           W.\
           10                                                                                                                                              Y

            0.1 5          2                                   5            1              2                     5                10           20          30
      Trace: 27                                                                      Frequency (MHz)




                                                                    Read    LISN     Cable                 Limit          Over
                                                      Freq         Level Factor        Loss       Level      Line     Linit Remark

                                                       NHz          dBu?        dB      db         dBu¥y     dBu¥           dB
                            1                         .154         48.70   —D.45     10.78        59.03    65.78      —6.75      QP
                            2                         .154         33.65   —0.45     10.78        43.98    55.78     —11.80      Average
                            3                         0.211        40.68   —0.41     10.76        51.03    63.18     —12.15      QP
                            4                         0.211        26.66   —O.41     10.76        37.01    §3.18     —16.17      Average
                            5                         0.258        37.89   —0.40     10.75        48.24    61.51     —13.27      QP
                            6                         0.258        22.63   —0.40     10.75        32.98    51.51     —18.53      Average
                            T                         0.313        34.99   —0.38     10.74        45.35    59.88     —14.53      QP
                            8                         0.313        20.38   —0.38     10.74        30.74    49.88     —19.14      Average
                            9                         0.406        36.33   —D.37     10.72        46.68    57.73     —11.05      QP
                           10                         0.406        21.71   —0.37     10.72        32.06    47.73     —15.67      Average
                           11                         0.471        23.59   —0.38     10.75        33.96    46.49     —12.53      Average
                           12                         0.474        33.75   —0.39     10.75        44.11    56.45     —12.34      QP



 Notes:
 1. An initial pre—scan was performed on the line and neutral lines with peak detector.
 2.   Quasi—Peak and Average measurement were performed at the frequencies with maximized peak emission.
 3. Final Level =Receiver Read level + LISN Factor + Cable Loss.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                                     Project No.: CCISE1907107
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                                                         Page 9 of 18


CCIS                                                                                                             Report No: CCISE190710702


 Product name:                                  1080P Smart Wi—Fi Security Camera               Product model:         HM211
Test by:                                        Yaro                                            Test mode:             Recording mode

Test frequency:                                 150 kHz ~ 30 MHz                                Phase:                 Neutral

Test voltage:                                   AC 120 V/6O Hz                                  Environment:           Temp: 22.5°C           Huni: 55%

           so Level (dBuV)


           70
                                                                                                                                 FCC PART15 B OP
           60
                         I
           5o J "L'Tmflifl @                                                                                                       FCC PART15B AV



           1| KAl )
            l |I
           30                               n      W
                                                                       1                                          y
                                 M              l l                     |
           2n      ||                EPEA           3            M lt                                                 WM”" A\|
           10                                                                                                                                    T


            16          12                               &                  1              2                 5              10           20
     Trace: 25                                                                       Frequency (MHz)




                                                              Read    LISN           Cable             Limit       Over
                                                 Freq        Level Factor              Loss   Level     Line      Limit Remark

                                                  MHz         dBu¥              dB      dB     dBu¥      dBu¥         dB

                             1                  0.158        48.50    —0.68          10.77    58.59    65.56      —6.97 QP
                             2                  0.158        44.34    —0.68          10.77    54.43    55.56      —1.13 Average
                             3                  0.206        §0.75    —0.69          10.76    60.82    63.36      —2.54 QP
                             4                  0.214        3§6.13   —0.68          10.76    45.21    53.05      —7.84 Average
                             5                  0.262        47.91    —0.65          10.75    §8.01    61.38      —3.37
                          6                     0.262        31.09    —0.65          10.75    41.19    51.38     —10.19    Average
                          T                     0.310        45.23    —0.63          10.74    55.3     59.97      —4.63    QP
                          8                     0.318        26.18    —0.63          10.74    36.29    49.75     —13.46    Average
                          9                     0. 366       42.05    —0.64          10.73    §2.14    58.61      —6.47    QP
                         10                     0.373        23.34    —0.64          10.73    33.43    48.43     —15.00    Average
                         11                     0.410        38.59    —0.64          10.72    48.67    57.64      —8.97    QP
                         12                     0.431        20.82    —0.64          10.73    30.91    47.24     —16.33    Average




 Notes:
 1. An initial pre—scan was performed on the line and neutral lines with peak detector.
2.   Quasi—Peak and Average measurement were performed at the frequencies with maximized peak emission.
 3. _Final Level =Receiver Read level + LISN Factor + Cable Loss.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                               Project No.: CCISE1907107
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                                               Page 10 of 18


                                                                             Report No: CCISE190710702

6.2 Radiated Emission
       Test Requirement:              FCC Part 15 B Section 15.109
       Test Method:                   ANSI C63.4:2014
       Test Frequency Range:          30MHz to 25000MHz
       Test site:                     Measurement Distance: 3m (Semi-Anechoic Chamber)
       Receiver setup:                  Frequency       Detector        RBW      VBW              Remark
                                       30MHz-1GHz      Quasi-peak      120kHz   300kHz       Quasi-peak Value
                                                         Peak           1MHz     3MHz          Peak Value
                                       Above 1GHz
                                                         RMS            1MHz     3MHz         Average Value
       Limit:                                Frequency           Limit (dBuV/m @3m)             Remark
                                           30MHz-88MHz                    40.0              Quasi-peak Value
                                          88MHz-216MHz                    43.5              Quasi-peak Value
                                         216MHz-960MHz                    46.0              Quasi-peak Value
                                           960MHz-1GHz                    54.0              Quasi-peak Value
                                                                          54.0               Average Value
                                            Above 1GHz
                                                                          74.0                Peak Value
       Test setup:                    Below 1GHz




                                      Above 1GHz




       Test Procedure:                  1. The EUT was placed on the top of a rotating table 0.8 meters above
                                           the ground at a 3 meter semi-anechoic camber. The table was rotated
                                           360 degrees to determine the position of the highest radiation.
                                        2. The EUT was set 3 meters away from the interference-receiving
                                           antenna, which was mounted on the top of a variable-height antenna
                                           tower.
                                        3. The antenna height is varied from one meter to four meters above the
                                           ground to determine the maximum value of the field strength. Both
Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                          Project No.: CCISE1907107
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                         Page 11 of 18


                                                                               Report No: CCISE190710702

                                           horizontal and vertical polarizations of the antenna are set to make the
                                           measurement.
                                        4. For each suspected emission, the EUT was arranged to its worst case
                                           and then the antenna was tuned to heights from 1 meter to 4 meters
                                           and the rotatable table was turned from 0 degrees to 360 degrees to
                                           find the maximum reading.
                                        5. The test-receiver system was set to Peak Detect Function and
                                           Specified Bandwidth with Maximum Hold Mode.
                                        6. If the emission level of the EUT in peak mode was 10dB lower than the
                                           limit specified, then testing could be stopped and the peak values of
                                           the EUT would be reported. Otherwise the emissions that did not have
                                           10dB margin would be re-tested one by one using peak, quasi-peak or
                                           average method as specified and then reported in a data sheet.
       Test Instruments:                Refer to section 5.10 for details
       Test mode:                       Refer to section 5.3 for details
       Test results:                    Passed
       Remark:                          All of the observed value above 6GHz ware the niose floor , which were
                                        no recorded




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                            Project No.: CCISE1907107
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                            Page 12 of 18


c c I s                                                                                                       Report No: CCISE190710702

Measurement Data:
Below 1GHz:

 Product Name:                      1080P Smart Wi—Fi Security Camera                        Product Model:        HM21 1

Test By:                            Yaro                                                  Test mode:               Recording mode

Test Frequency:                     30 MHz ~ 1 GHz                                           Polarization:         Vertical

Test Voltage:                       AC 120/60Hz                                              Environment:          Temp: 24°C       Huni: 57%



      so Level (dBu\Vim)


      70

      60
                                                                                                                   FCC PART1S CLASS$ B




           30                  50                     100                                200                       500                1000
                                                                               Frequency (MHz)




                                            Readintenna      Cable Preanp                                Limit    Over
                               Freq        Level Factor        Loss Factor                     Level      Line   Limit Remark

                                NBz         dbu¥y    db/m                       dB      dB dBu¥/m dBu¥/n            dB
                             94.T60        55.26    11.30                      .01   29.55     39.02     43.50   —4.48   QP
            on on & oo ho




                                                             c co co Ca + ho




                            100.581        54.00    12.46                      .94   29.52     38.88     43.50   —4.62   QP
                            336.036        §1.13    14.33                      .05   28.53     39.98     46.00   —6.02   QP
                            451.135        53.50    16. 50                     .21   28.87     44.34     46.00   —1.66   QP
                            501.179        44.01    18. 20                     .63   28.96     36.88     46.00   —9.12   QP
                            651.942        42.93    19.74                      .87   28.77     37.77     46.00   —8.23   QP




 Remark:
 1. Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preampiifier Factor.
2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                       Project No.: CCISE1907107
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                                         Page 13 of 18


c c I s                                                                                                       Report No: CCISE190710702



 Product Name:                         1080P Smart Wi—Fi Security Camera                     Product Model:         HM211

Test By:                               Yaro                                                  Test mode:             Recording mode

Test Frequency:                        30 MHz ~ 1 GHz                                        Polarization:          Horizontal

Test Voltage:                          AC 120/60Hz                                           Environment:           Temp: 24°C        Huni: 57%




      so Level (dBu\Vim)


      70


      60
                                                                                                                    FCC PART1S CLASS$ B




           30                     50                    100                                 200                     500                1000
                                                                                  Frequency (MHz)




                                               Readintenna     Cable Preamp                               Limit    Over
                                  Freq        Level Factor       Loss Factor                    Level      Line   Limit Remark

                                   NHz         dBu¥y   dB/n                        dB      dB dBu¥/m dBu¥/nm         dB
                               287.990        48.01    13.41                      .91   28.47   35.86     46.00 —10.14 QP
                o on & ca ho




                                                               w co oo ca co ho




                               336.036        52.80    14.33                      .05   28.53   41.65     46.00 —4.35 QP
                               400.432        §2.49    15.30                      .08   28.78   42.09     46.00 —3.91 QP
                               408.946        54.74    15.51                      .10   28.80   44.55     46.00 —1.45 QP
                               432.546        50.05    16.07                      .16   28.84   40.44     46.00 —5.56 QP
                               651.942        41.94    19.74                      .81   28.77   36.78     46.00 —9.22 QP




 Remark:
1.   Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preampiifier Factor.
2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                        Project No.: CCISE1907107
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                                          Page 14 of 18


CCIS                                                                                      Report No: CCISE190710702

Above 1GHz:
 Product Name:                    1080P Smart Wi—Fi Security Camera      Product Model:           HM211

 Test By:                         Yaro                                   Test mode:               Recording mode

 Test Frequency:                  1 GHz ~6 GHz                           Polarization:            Vertical

 Test Voltage:                    AC 120/60Hz                            Environment:             Temp: 24°C         Huni: 57%



       8(]I.(-:-vr-:‘l (dBuVim)
                                                                                                        FCC PART 15 (PK)
       70

       60
                                                                                                        FCC PART 15 (AV)




            1000      1200           1500            2000                                                    5000    6000
                                                             Frequency (MHz)




                                          Readintenna    Cable Preamp                  Limit    Over
                              Freq       Level Factor      Loss Factor         Level    Line   Linit Remark

                     """"NHz              dbu?    dB/n        dB       dB dBu¥/m dBuT/m            d6
               1.      2854.354          48.33   28.20      5.19   41.62       41.95   74.00   —32.05    Peak
               2        2854.354         38.30   28.20      5.19   41.62       31.92   54.00   —22.08    Average
               3        4171.593         49.03   30.33      6.36   41.81       46.17   74.00   —27.83    Peak
               4        4171.593         38.78   30.33      6.36   41.81       35.92   54.00   —18.08    Average
               5       5864.002          49.68   32.67      7.90   42.03       50.98   74.00   —23.02    Peak
               6        5864.002         39.26   32.67      7.90   42.03       40.56   54.00   —13.44    Average




 Remark:
 1.   Final Level = Receiver Read level + Antenna Factor + Cable Loss— Preamplifier Factor.
 2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                      Project No.: CCISE1907107
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                         Page 15 of 18


CCIS                                                                                  Report No: CCISE190710702



 Product Name:              1080P Smart Wi—Fi Security Camera        Product Model:            HM21 1

Test By:                    Yaro                                     Test mode:                Recording mode

Test Frequency:             1 GHz ~6 GHz                             Polarization:             Horizontal

Test Voltage:               AC 120/60Hz                              Environment:              Temp: 24°C          Huni: 57%


       80Level (dBuVim)
                                                                                                      FCC PART 15 (PK)
       70

       60
                                                                                                      FCC PART 15(A\{)
       50                                                                                        3                    &

       40


       30

       20


       10


            1000   1200          1500            2000                                                       5000     6000
                                                        Frequency (MHz)




                                    Readintenna     Cable Preamp                  Limit      Over
                          Freq     Level Factor       Loss Factor        Level     Line     Limit Remark

                           NHz      dbuvy    dB/m        dB        dB dBu¥/m dBu¥/n              dB
              1.   2927.481        47.82    28.35     5.28    41.56      41.76    74.00    —32. 24    Peak
              2     2927.481       36.15    28.35     5.28    41.56      30.09    54.00    —23.91     Average
              3    4253.563        49.61    30.35     6.48    41.85      46.87    74.00    —27.13     Peak
              4     4253.563       37.94    30.35     6.48    41.85      35.20    54.00    —18.80     Average
              5     §829.869       48.67    32.67     T.90    42.03      49.96    74.00    —24.04     Peak
              6     5829.869       37.78    32.67     7.90    42.03      39.07    54.00    —14.93     Average



 Remark:
1.   Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preampiifier Factor.
2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                    Project No.: CCISE1907107
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                        Page 16 of 18



Document Created: 2019-10-09 14:45:07
Document Modified: 2019-10-09 14:45:07

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC