SAR evaluation


MPE Calculation Method
                       0.5
E (V/m) = (30*P*G)       /d
Power Density: Pd (W/m2) = E2/377
E = Electric Field (V/m)
P = Peak RF output Power (W)
G = EUT Antenna numeric gain (numeric)
d = Separation distance between radiator and human body (m)
The formula can be changed to
Pd = (30*P*G) / (377*d2)
From the peak EUT RF output power, the minimum mobile separation distance,
d=0.2m, as well as the gain of the used antenna, the RF power density can
be obtained.


Calculated Result and Limit (WORSE CASE IS AS BELOW)
Directional    Peak Output          Power Density   Limit of Power   Test
AntennaGain    Power (mW)           (S)(mW/cm2)     Density (S)      Result
(Numeric)                                           (mW/cm2)


3.163          9.661                0.0061          1                Compiles
(5.0 dBi)      (9.85dBm@2462MHz)