RF Test Report

FCC ID: 2APYEHB2019D27

Test Report

Download: PDF
FCCID_4314348

                             Test Report No.:RF190410N018



                                                                   TEST REPORT
       Applicant                       Huabo Smart Living Technology Co.,Ltd

                                       Chenghua Industrial Zone,Wenguan Road,Chenghai District,Shantou City,Guangdong
       Address
                                       China.


       Manufacturer or
                                       Huabo Smart Living Technology Co.,Ltd
       Supplier
                                       Chenghua Industrial Zone,Wenguan Road,Chenghai District,Shantou City,Guangdong
       Address
                                       China.
       Product                         Toy RC Bumper Car Set Retro COMPOSITE

       Brand Name                      FAO Schwarz

       Model                           HB2019D

       Additional Model &
                                       1002777
       Model Difference:

       Date of tests                   May 12 to May 17, 2019

       the tests have been carried out according to the requirements of the following standards:

            FCC Part 15, Subpart C, Section 15.227

       CONCLUSION: The submitted sample was found to COMPLY with the test requirement

                             Tested by Evans He                                                              Approved by David Huang
                     Project Engineer / EMC Department                                                      Supervisor / EMC Department




                                                                                                                    Date: May 20, 2019
       This report is governed by, and incorporates by reference, CPS Conditions of Service as posted at the date of issuance of this report at
       http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/ and is intended for your exclusive use. Any copying or
       replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report
       sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the
       quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our
       report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is
       only provided upon request for accredited tests. You have 60 days from date of issuance of this report to notify us of any material error or omission caused
       by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the
       issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute you unqualified acceptance of the completeness of this
       report, the tests conducted and the correctness of the report contents.


                                                          No. 34, Chenwulu Section, Guantai Rd., Houjie                Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                                                     Town, Dongguan City,                              Fax: +86 769 8593 1080
Dongguan Branch                                                    Guangdong 523942, China                             Email: DGservice@cn.bureauveritas.com
                                                                               Page 1 of 21                                                                Report Version 1


                             Test Report No.:RF190410N018




                                                             TABLE OF CONTENTS
          RELEASE CONTROL RECORD ....................................................................................................................... 3
          1       SUMMARY OF TEST RESULTS ................................................................................................................ 4

              2        MEASUREMENT UNCERTAINTY.......................................................................................................... 4
          3       GENERAL INFORMATION ....................................................................................................................... 5

              3.1      GENERAL DESCRIPTION OF EUT ......................................................................................................... 5
              3.2      DESCRIPTION OF TEST MODES............................................................................................................ 6
              3.3      GENERAL DESCRIPTION OF APPLIED STANDARDS ........................................................................ 6
              3.4      DESCRIPTION OF SUPPORT UNITS ...................................................................................................... 6
          4       TEST TYPES AND RESULTS ..................................................................................................................... 7
              4.1 RADIATED EMISSION MEASUREMENT ............................................................................................... 7
                   4.1.1       LIMITS OF RADIATED EMISSION MEASUREMENT .................................................................... 7
                   4.1.2       TEST INSTRUMENTS ....................................................................................................................... 8
                   4.1.3       TEST PROCEDURES ....................................................................................................................... 9
                   4.1.4       DEVIATION FROM TEST STANDARD ............................................................................................ 9
                   4.1.5       TEST SETUP ................................................................................................................................... 10
                   4.1.6       EUT OPERATING CONDITIONS .................................................................................................. 11
                   4.1.7       TEST RESULTS ............................................................................................................................... 11
              4.2      BANDWIDTH MEASUREMENT ........................................................................................................... 16
              4.2.1        LIMITS OF BANDWIDTH MEASUREMENT .................................................................................. 16
              4.2.2        TEST INSTRUMENTS ....................................................................................................................... 16
              4.2.3        TEST PROCEDURE............................................................................................................................ 18
              4.2.4        DEVIATION FROM TEST STANDARD ............................................................................................ 18
              4.2.5        TEST SETUP ....................................................................................................................................... 18
              4.2.6        EUT OPERATING CONDITIONS ...................................................................................................... 18
              4.2.7        TEST RESULTS .................................................................................................................................. 19
          5       PHOTOGRAPHS OF THE TEST CONFIGURATION .......................................................................... 20
          6 APPENDIX A - MODIFICATIONS RECORDERS FOR ENGINEERING CHANGES TO THE EUT
          BY THE LAB....................................................................................................................................................... 21




                                                             No. 34, Chenwulu Section, Guantai Rd., Houjie                    Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                                                        Town, Dongguan City,                                  Fax: +86 769 8593 1080
Dongguan Branch                                                       Guangdong 523942, China                                 Email: DGservice@cn.bureauveritas.com
                                                                                   Page 2 of 21                                                                     Report Version 1


                       Test Report No.:RF190410N018



                                    RELEASE CONTROL RECORD

                ISSUE NO.                       REASON FOR CHANGE                                    DATE ISSUED
              RF190410N018                            Original release                                May 20, 2019




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                                  Town, Dongguan City,                 Fax: +86 769 8593 1080
Dongguan Branch                                 Guangdong 523942, China                Email: DGservice@cn.bureauveritas.com
                                                       Page 3 of 21                                              Report Version 1


                       Test Report No.:RF190410N018


          1 SUMMARY OF TEST RESULTS
          The EUT has been tested according to the following specifications:
                     APPLIED STANDARD: FCC PART 15, SUBPART C , SECTION 15.227(2015-10)
            STANDARD
                                    TEST TYPE AND LIMIT                  RESULT                     REMARK
             SECTION
           §15.207 (a)          AC Power Conducted Emission                 N/A           EUT is powered by battery
            §15.209
                                     Radiated Emission                     PASS                    Compliant
            §15.227
            §15.215(c)              20dB Bandwidth Test                    PASS                    Compliant
                                                                                          No antenna connector is
              §15.203               Antenna Requirement                     N/A
                                                                                                  used

          NOTE:       Test Lab Information:

                      Lab: Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch
                       Test Lab Address: Zone A, Floor 1, Building 2 Wan Ye Long Technology
                       Park South Side of Zhoushi Road, Bao’an District Shenzhen,
                       Guangdong, 518108, People’s Republic of China




          2 MEASUREMENT UNCERTAINTY
          Where relevant, the following measurement uncertainty levels have been estimated
          for tests performed on the EUT as specified in CISPR 16-4-2:
                      MEASUREMENT                           FREQUENCY                           UNCERTAINTY
                                                            9KHz ~ 30MHz                              2.16dB
                                                            30MHz ~ 1GHz                              3.74dB
                     Radiated emissions
                                                            1GHz ~ 18GHz                              4.66dB
                                                           18GHz ~ 40GHz                              4.67dB

          This uncertainty represents an expanded uncertainty expressed at approximately the
          95% confidence level using a coverage factor of k = 2.




                                          No. 34, Chenwulu Section, Guantai Rd., Houjie    Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                                     Town, Dongguan City,                  Fax: +86 769 8593 1080
Dongguan Branch                                    Guangdong 523942, China                 Email: DGservice@cn.bureauveritas.com
                                                          Page 4 of 21                                               Report Version 1


                       Test Report No.:RF190410N018


          3 GENERAL INFORMATION
          3.1 GENERAL DESCRIPTION OF EUT

          PRODUCT                            Toy RC Bumper Car Set Retro COMPOSITE
          MODEL NO.                          HB2019D
          ADDITIONAL MODEL                   1002777
          FCC ID                             2APYEHB2019D27
          NOMINAL VOLTAGE                    DC 3V(1.5V*AAA*2) From Battery
          MODULATION TYPE                    CM
          OPERATING FREQUENCY                27.13MHz
          NUMBER OF CHANNEL                  1
          ANTENNA TYPE                       Spring Antenna with 0dBi gain
          I/O PORTS                          Refer to user’s manual

          NOTE:

          1.   For a more detailed features description, please refer to the manufacturer’s specifications or the
               user's manual.

          2.   For the test results, the EUT had been tested with all conditions, but only the worst case was
               shown in test report.

          3.   Please refer to the EUT photo document (Reference No.: 190410N018) for detailed product
               photos.

          4.   Additional models (see about table) are identical with the test model HB2019D except the
               appearance、trade name and model no. for trading purpose.




                                           No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                                      Town, Dongguan City,                 Fax: +86 769 8593 1080
Dongguan Branch                                     Guangdong 523942, China                Email: DGservice@cn.bureauveritas.com
                                                           Page 5 of 21                                              Report Version 1


                       Test Report No.:RF190410N018



          3.2 DESCRIPTION OF TEST MODES
          Pre-Scan has been conducted to determine the worst-case mode from all possible
          combinations between available modulations, data rates, XYZ axis and packet type.
          The worst case was found when the EUT was positioned on Y axis for radiated
          emission. The EUT was tested under the following mode.


                                FREQUENCY                      TEST MODES
                                    27.13 MHz                    Transmitting


          3.3 GENERAL DESCRIPTION OF APPLIED STANDARDS

           The EUT is a RF Product. According to the specifications of the manufacturer, it
           must comply with the requirements of the following standards:

           FCC Part 15, Subpart C, 15.227
           ANSI C63.10-2013

           All test items have been performed and recorded as per the above standards.



          3.4 DESCRIPTION OF SUPPORT UNITS

             The EUT has been tested as an independent unit without any other necessary
             accessories or support units.




                                          No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                                     Town, Dongguan City,                 Fax: +86 769 8593 1080
Dongguan Branch                                    Guangdong 523942, China                Email: DGservice@cn.bureauveritas.com
                                                          Page 6 of 21                                              Report Version 1


                        Test Report No.:RF190410N018


          4       TEST TYPES AND RESULTS

          4.1     RADIATED EMISSION MEASUREMENT

          4.1.1 LIMITS OF RADIATED EMISSION MEASUREMENT

              Emissions radiated outside of the specified bands, shall be according to the
              general radiated limits in 15.209 as following:
                      FREQUENCIES                 FIELD STRENGTH                   MEASUREMENT DISTANCE
                         (MHz)                    (microvolts/meter)                     (meters)
                        0.009 ~ 0.490                  2400/F(kHz)                                 300
                        0.490 ~ 1.705                 24000/F(kHz)                                  30
                        1.705 ~ 30.0                         30                                     30
                           30 ~ 88                           100                                     3
                          88 ~ 216                           150                                     3
                         216 ~ 960                           200                                     3
                         Above 960                           500                                     3


              According to §15.227(a), the field strength of emissions from intentional radiators
              operated within these frequency bands shall comply with the following:
                                                  Field Strength of                        Field Strength of
                Frequency Range of
                                               Fundamental Emission                     Fundamental Emission
                   Fundamental
                                                       [Peak]                                  [Average]
                      [MHz]
                                                       [V/m]                                    [V/m]
                    26.96 – 27.28               100,000 (100 dBV/m)                      10,000 (80 dBV/m)
                NOTE:
                1. The lower limit shall apply at the transition frequencies.
                2. Emission level (dBuV/m) = 20 log Emission level (uV/m).
                3. As shown in 15.35(b), for frequencies above 1000MHz, the field strength limits are based on
                   average detector, however, the peak field strength of any emission shall not exceed the
                   maximum permitted average limits, specified above by more than 20dB under any condition of
                   modulation.




                                             No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                                        Town, Dongguan City,                 Fax: +86 769 8593 1080
Dongguan Branch                                       Guangdong 523942, China                Email: DGservice@cn.bureauveritas.com
                                                             Page 7 of 21                                              Report Version 1


                       Test Report No.:RF190410N018



          4.1.2 TEST INSTRUMENTS

                    Instrument              Model                 Serial #               Cal Date            Cal Due

             Agilent ESA-E SERIES
                                           E4407B             MY45108319                Feb 11, 19         Feb. 10, 20
            SPECTRUM ANALYZER
                                                             1300.5001K06-
                EMI test receiver            ESL6                                       Jan, 05, 19        Jan. 04, 20
                                                               100262-eQ
           SYNTHESIZED SIGNAL
                                            8665B              3744A01293               Jan, 05, 19        Jan. 04, 20
                 GENERATOR
                 Bilog Antenna
                                              JB6                A110712                Feb 08, 19         Feb. 07, 20
                (30MHz~6GHz)
                 Bilog Antenna
                                              JB1                A112017                Jan 26, 19         Jan. 25, 20
                (30MHz~2GHz)
           A-INFOMW Horn Antenna
                                           AH-118                  71259                Jan 26, 19         Jan. 25, 20
                   (1~18GHz)
                  Pre-Amplifier             EMC
                                                                  980077                May 18, 18         May 17, 19
              (100MHz-26.5GHz)             012645
                  Pre-Amplifier             EMC
                                                                  980102                Nov. 08,18          Nov. 07,19
                (18GHz-40GHz)              184045
             EMCO Horn Antenna
                                           AH-118                  71283                Feb 02, 19         Feb. 01, 20
                   (1~18GHz)
             OPT 010 AMPLIFIER
                                            8447E              2727A02430               Dec. 09, 18        Dec. 08, 19
                (0.1~1300MHz)
                  Horn Antenna           BBHA 9170           BBHA9170147                Mar. 13, 19        Mar. 12, 20
             Microwave Preamplifier
                                          PAM-118                 443008                Dec. 09, 18        Dec. 08, 19
                 (0.5~18GHz)

              Large Loop Antenna            RF300                  Rf300                Dec. 09, 18        Dec. 08, 19
               Universal Radio
                                           CMU200                 121393                Feb 11, 19         Feb. 10, 20
             Communication Tester
              Positioning Controller       UC3000             MF780208282               Dec. 09, 18        Dec. 08, 19

                  Test Software            EZ-EMC              ver.Icp-03A1                 N/A                 N/A

          NOTE:
             1. The test was performed in 966 Chamber (a 3m Semi-anechoic chamber).
             2. The calibration interval of the above test instruments are 12 months and the calibrations are
                traceable to CEPREI/CHINA, GRGT/CHINA and NIM/CHINA.
             3. The horn antenna is used only for the measurement of emission frequency above1GHz if tested.
             4. The FCC Site Registration No. is 749762.




                                        No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                                   Town, Dongguan City,                 Fax: +86 769 8593 1080
Dongguan Branch                                  Guangdong 523942, China                Email: DGservice@cn.bureauveritas.com
                                                        Page 8 of 21                                              Report Version 1


                       Test Report No.:RF190410N018



          4.1.3 TEST PROCEDURES
          The basic test procedure was in accordance with ANSI C63.10 (section 6).
           a. The EUT was placed on the top of a rotating table 0.8 meters above the
              ground at a 3m chamber room. The table was rotated 360 degrees to
              determine the position of the highest radiation. (Below 1000MHz)
           b. The EUT was placed on the top of a rotating table 0.8 meters above the
              ground at a 10m chamber room. The table was rotated 360 degrees to
              determine the position of the highest radiation. (Below 30MHz)
           c. The EUT was set 3 meters away from the interference-receiving antenna,
              which was mounted on the top of a variable-height antenna tower.
           d. The height of antenna is varied from one meter to four meters above the
              ground to determine the maximum value of the field strength. Both horizontal
              and vertical polarizations of the antenna are set to make the measurement.
           e. For each suspected emission, the EUT was arranged to its worst case and
              then the antenna was tuned to heights from 1 meter to 4 meters and the
              rotatable table was turned from 0 degrees to 360 degrees to find the
              maximum reading.
           f. The test-receiver system was set to quasi-peak detect function and specified
              bandwidth with maximum hold mode when the test frequency is below 1 GHz.
           g. During the test, each emission was maximized by: having the EUT
              continuously working, investigated all operating modes, rotated about all 3 axis
              (X, Y & Z) and considered typical configuration to obtain worst position Y,
              manipulating interconnecting cables, For battery operated equipment, the
              equipment tests shall be perform using new battery. The turntable was rotated
              to maximize the emission level.
           h. For below 30MHz, a loop antenna with its vertical plane is place 3m from the
              EUT and rotated about its vertical axis for maximum response at each azimuth
              about the EUT. And the centre of the loop shall be 1m above the ground.
           NOTE:
            1. The resolution bandwidth of test receiver/spectrum analyzer is 120kHz for Quasi-peak detection
               (QP) at frequency below 1GHz.
            2. Emission level(dBuV/m)=Raw Value(dBuV) + Correction Factor(dB/m)
            3. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB)
            4. Margin value = Emission level – Limit value.
            5. Fundamental AV value =PK Emission +AV Factor.


          4.1.4 DEVIATION FROM TEST STANDARD

           No deviation.




                                         No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                                    Town, Dongguan City,                 Fax: +86 769 8593 1080
Dongguan Branch                                   Guangdong 523942, China                Email: DGservice@cn.bureauveritas.com
                                                         Page 9 of 21                                              Report Version 1


                       Test Report No.:RF190410N018



          4.1.5 TEST SETUP
          Below 30MHz




          30MHz~1GHz



                                                                    Ant. Tower
                                                                                               1-4m
                                                   3m
                                EUT

                                            Turn Table

                         0.8m


                                                  Ground Plane

                                                 Spectrum




          For the actual test configuration, please refer to the attached file (Test Setup Photo).



                                       No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                                  Town, Dongguan City,                 Fax: +86 769 8593 1080
Dongguan Branch                                 Guangdong 523942, China                Email: DGservice@cn.bureauveritas.com
                                                      Page 10 of 21                                              Report Version 1


                        Test Report No.:RF190410N018


          4.1.6 EUT OPERATING CONDITIONS


                 a. Turned on the power of equipment.
                 b. Hold down the TX of button, then the EUT was operating.
                 c. EUT was operated according to the type used was description in
                    manufacturer’s specifications or the User's Manual.

          4.1.7 TEST RESULTS

             FIELD STRENGTH OF FUNDAMENTAL


             ANTENNA POLARITY: 0°

                         Freq.           Correction            Raw            Emission              Limit           Margin

           No.           (MHz)             Factor              Value             Level            (dBuV/m)            (dB)

                                           (dB/m)             (dBuV)          (dBuV/m)

            *          27.13(PK)           -11.75              71.66             59.91               100             -40.09

            *          27.13(AV)            -5.64                 -              54.27                80             -25.73



             ANTENNA POLARITY: 90°

                         Freq.           Correction            Raw            Emission              Limit           Margin

           No.           (MHz)             Factor              Value             Level            (dBuV/m)            (dB)

                                           (dB/m)             (dBuV)          (dBuV/m)

            *          27.13(PK)           -11.75              94.21             82.46               100             -17.54

            *          27.13(AV)            -5.64                 -              76.82                80             -3.18


                REMARKS: 1. Emission level (dBuV/m) = Raw Value (dBuV) + Correction Factor (dB/m).
                            2. Correction Factor (dB/m) = Antenna Factor (dB/m) + Cable Factor (dB).
                            3. Margin value = Emission level – Limit value.
                            4. “ * “: Fundamental frequency.
                            5. The average value of fundamental frequency is: Average value = Peak value +AV
                                factor, where the AV factor is calculated from following formula: AV factor=20 log
                                (Duty cycle) = 20 log (52.23%) = -5.64dB, Please see page 12~13 for plotted duty.

                                            No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                                       Town, Dongguan City,                 Fax: +86 769 8593 1080
Dongguan Branch                                      Guangdong 523942, China                Email: DGservice@cn.bureauveritas.com
                                                           Page 11 of 21                                              Report Version 1


                       Test Report No.:RF190410N018



          Duty Cycle:
               Tp = 73.05ms


                 Ton = Ton1 * Number+ Ton2 * Number =4*1.512+64*0.5016= 38.1504ms

                 Duty Cycle = Ton / Tp * 100% = 38.1504/73.05= 52.23%
          Tp=73.05ms




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                                  Town, Dongguan City,                 Fax: +86 769 8593 1080
Dongguan Branch                                 Guangdong 523942, China                Email: DGservice@cn.bureauveritas.com
                                                      Page 12 of 21                                              Report Version 1


                       Test Report No.:RF190410N018



          Ton1=1.512ms




          Ton2= 0.5016ms




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                                  Town, Dongguan City,                 Fax: +86 769 8593 1080
Dongguan Branch                                 Guangdong 523942, China                Email: DGservice@cn.bureauveritas.com
                                                      Page 13 of 21                                              Report Version 1


                       Test Report No.:RF190410N018




                                                                       DETECTOR
          FREQUENCY RANGE                9KHz ~ 1GHz                                                   Quasi-Peak (QP)
                                                                       FUNCTION


                          ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 m
              No.   Frequency       Reading    Ant_F    PA_G       Cab_L    Result        Limit        Margin   Height   Degree
                      (MHz)         (dBuV/m)   (dB/m)    (dB)       (dB)   (dBuV/m)    (dBuV/m)         (dB)     (cm)      ()

               1    31.3992          27.15     19.20    22.27      0.14     24.22        40.00        -15.78     200      221
               2    54.2610          28.80     7.44     22.39      0.25     14.10        40.00        -25.90     100      217
               3    81.4970          31.26     6.85     22.41      0.55     16.25        40.00        -23.75     100       38
               4    162.6106         30.02     11.05    22.27      1.34     20.14        43.50        -23.36     100       78
               5    271.3246         29.60     12.92    22.29      1.66     21.89        46.00        -24.11     100      186
               6    790.6188         28.92     22.11    21.17      2.54     32.40        46.00        -13.60     100        3
          REMARKS:
                 1. Result (dBuV/m) = Reading Value (dBuV) + Correction Factor (dB/m).
                 2. Correction Factor (dB/m) = Ant_F (dB/m) + Cab_L (dB) - PA_G (dB).
                 3. The emission levels of other frequencies were less than 20dB margin against the limit.
                 4. Margin value = Result level – Limit value.




                                               No. 34, Chenwulu Section, Guantai Rd., Houjie      Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                                          Town, Dongguan City,                    Fax: +86 769 8593 1080
Dongguan Branch                                         Guangdong 523942, China                   Email: DGservice@cn.bureauveritas.com
                                                                Page 14 of 21                                               Report Version 1


                       Test Report No.:RF190410N018




                                                                    DETECTOR
          FREQUENCY RANGE               9KHz ~ 1GHz                                               Quasi-Peak (QP)
                                                                    FUNCTION


                          ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 m
          No.   Frequency     Reading    Ant_F    PA_G     Cab_L      Result       Limit      Margin   Height   Degree
                  (MHz)      (dBuV/m)    (dB/m)   (dB)      (dB)     (dBuV/m)    (dBuV/m)      (dB)     (cm)      ()

           1    54.2610       36.96      7.44     22.39    0.25       22.26       40.00      -17.74     100       30
           2    81.4970       35.95      6.85     22.41    0.55       20.94       40.00      -19.06     200      246
           3    95.4270       30.63      8.24     22.32    0.78       17.33       43.50      -26.17     100      291
           4    166.0680      32.90      11.09    22.26    1.36       23.09       43.50      -20.41     100       46
           5    601.4265      24.95      20.30    21.58    2.31       25.98       46.00      -20.02     100      325
           6    972.3374      25.19      23.70    20.74    2.73       30.88       54.00      -23.12     100      216
          REMARKS:
                 1. Result (dBuV/m) = Reading Value (dBuV) + Correction Factor (dB/m).
                 2. Correction Factor (dB/m) = Ant_F (dB/m) + Cab_L (dB) - PA_G (dB).
                 3. The emission levels of other frequencies were less than 20dB margin against the limit.
                 4. Margin value = Result level – Limit value.




                                             No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                                        Town, Dongguan City,                 Fax: +86 769 8593 1080
Dongguan Branch                                       Guangdong 523942, China                Email: DGservice@cn.bureauveritas.com
                                                            Page 15 of 21                                                Report Version 1


                       Test Report No.:RF190410N018



          4.2     BANDWIDTH MEASUREMENT
          4.2.1 LIMITS OF BANDWIDTH MEASUREMENT
          The field strength of any emissions appearing between the band edges and out of band shall
          be attenuated at least 20 dB below the level of the unmodulated carrier or to the general limits
          in Section 15.209.
                       FREQUENCY                       Limits
                          (MHz)                         [MHz]
                          27.13                  within 26.96-27.28

          4.2.2 TEST INSTRUMENTS

                    Instrument              Model                   Serial #              Cal Date           Cal Due

                                           Dare
                  Power Sensor                                         N/A               Jan. 05, 19       Jan. 04, 20
                                       RPR3006C/P/W
                                           Dare
                  Power Sensor                                         N/A               Jan. 05, 19       Jan. 04, 20
                                       RPR3006C/P/W
             Agilent ESA-E SERIES
                                           E4407B               MY45108319               Feb. 11, 19       Feb. 10, 20
            SPECTRUM ANALYZER
                                                               1300.5001K06-
                EMI test receiver            ESL6                                        Jan. 05, 19       Jan. 04, 20
                                                                 100262-eQ
                 Power Splitter               1#                     1#                 Dec. 09, 18        Dec. 08, 19
           SYNTHESIZED SIGNAL
                                            8665B                3744A01293              Jan. 05, 19       Jan. 04, 20
                 GENERATOR
               DC Power Supply             E3640A               MY40004013               Jan. 05, 19       Jan. 04, 20
                 Bilog Antenna
                                              JB6                  A110712              Feb. 08, 19        Feb. 07, 20
                (30MHz~6GHz)
                 Bilog Antenna
                                              JB1                  A112017               Jan. 26, 19       Jan. 25, 20
                (30MHz~2GHz)
           A-INFOMW Horn Antenna
                                           AH-118                     71259              Jan. 26, 19       Jan. 25, 20
                   (1~18GHz)
                  Pre-Amplifier
                                         EMC 012645                 980077               May 18, 18        May 17, 19
              (100MHz-26.5GHz)
                  Pre-Amplifier
                                         EMC 184045                 980102              Nov. 08, 18        Nov. 07, 19
                (18GHz-40GHz)
             EMCO Horn Antenna
                                           AH-118                     71283             Feb. 02, 19        Feb. 01, 20
                   (1~18GHz)
             OPT 010 AMPLIFIER
                                            8447E                2727A02430             Dec. 09, 18        Dec. 08, 19
                (0.1~1300MHz)
                  Horn Antenna           BBHA 9170             BBHA9170147               Mar. 13, 19       Mar. 12, 20
             Microwave Preamplifier
                                          PAM-118                   443008              Dec. 09, 18        Dec. 08, 19
                  (0.5~18GHz)

                    Attenuator               MINI                      N/A              Dec. 09, 18        Dec. 08, 19

                                       No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                                  Town, Dongguan City,                 Fax: +86 769 8593 1080
Dongguan Branch                                 Guangdong 523942, China                Email: DGservice@cn.bureauveritas.com
                                                      Page 16 of 21                                              Report Version 1


                       Test Report No.:RF190410N018


                  Test Software               EZ-EMC                ver.Icp-03A1                N/A                N/A

          NOTE:
             1. The test was performed in RF Oven room.
             2. The calibration interval of the above test instruments is 12 months and the calibrations are
                traceable to CEPREI/CHINA, GRGT/CHINA and NIM/CHINA.




                                          No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                                     Town, Dongguan City,                 Fax: +86 769 8593 1080
Dongguan Branch                                    Guangdong 523942, China                Email: DGservice@cn.bureauveritas.com
                                                         Page 17 of 21                                              Report Version 1


                       Test Report No.:RF190410N018


          4.2.3 TEST PROCEDURE

            a. Check the calibration of the measuring instrument using either an internal
               calibrator or a known signal from an external generator.
            b. Turn on the EUT and connect it to measurement instrument. Then set it to any
               one convenient frequency within its operating range. Set a reference level on the
               measuring instrument equal to the highest peak value.
            c. Measure the frequency difference of two frequencies that were attenuated 20dB
               from the reference level. Record the frequency difference as the emission
               bandwidth.
            d. Repeat above procedures until all frequencies measured were complete.


          4.2.4 DEVIATION FROM TEST STANDARD

           No deviation.



          4.2.5 TEST SETUP



                          EUT                                               SPECTRUM

                                          10dB ATTENUATION PAD              ANALYZER




          4.2.6 EUT OPERATING CONDITIONS
                   Same as item 4.1.6




                                        No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                                   Town, Dongguan City,                 Fax: +86 769 8593 1080
Dongguan Branch                                  Guangdong 523942, China                Email: DGservice@cn.bureauveritas.com
                                                       Page 18 of 21                                              Report Version 1


                        Test Report No.:RF190410N018


          4.2.7 TEST RESULTS


                  Lower & Upper Test Frequency Point               Test Frequency
                                                                                                    P/F
                                (MHz)                                   (MHz)
                                Lower                                  27.1207                     PASS
                                Upper                                  27.1711                     PASS

           Test Data:




                                        No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                                   Town, Dongguan City,                 Fax: +86 769 8593 1080
Dongguan Branch                                  Guangdong 523942, China                Email: DGservice@cn.bureauveritas.com
                                                       Page 19 of 21                                              Report Version 1


                       Test Report No.:RF190410N018



          5     PHOTOGRAPHS OF THE TEST CONFIGURATION

           Please refer to the attached file (Test Setup Photo).




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                                  Town, Dongguan City,                 Fax: +86 769 8593 1080
Dongguan Branch                                 Guangdong 523942, China                Email: DGservice@cn.bureauveritas.com
                                                      Page 20 of 21                                              Report Version 1


                       Test Report No.:RF190410N018



          6     APPENDIX A - MODIFICATIONS RECORDERS FOR
                ENGINEERING CHANGES TO THE EUT BY THE LAB


           No any modifications are made to the EUT by the lab during the test.




           ---END---




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                                  Town, Dongguan City,                 Fax: +86 769 8593 1080
Dongguan Branch                                 Guangdong 523942, China                Email: DGservice@cn.bureauveritas.com
                                                      Page 21 of 21                                              Report Version 1



Document Created: 2019-06-12 10:27:21
Document Modified: 2019-06-12 10:27:21