                       Test Report No.: FM190628N080



                                    RF EXPOSURE REPORT
    Applicant                        Zultys, Inc.

    Address                          785 Lucerne Drive, Sunnyvale, CA 94085, USA


    Manufacturer or
                                     Zultys, Inc.
    Supplier

    Address                          785 Lucerne Drive, Sunnyvale, CA 94085, USA

    Product                          Smart Business Phone

    Brand Name                       ZULTYS

    Model                            ZIP 49GE

    Additional Model &
                                     N/A
    Model Difference

    Date of tests                    Jun. 28, 2019 ~ Jul. 05, 2019

         FCC Part 2 (Section 2.1091)
         KDB 447498 D01
         IEEE C95.1


    CONCLUSION: The submitted sample was found to COMPLY with the test requirement


                          Tested by Andy Zhu                                                                Approved by Glyn He
                  Project Engineer / EMC Department                                                      Supervisor/ EMC Department




                                                                                                                 Date: Aug. 01, 2019
    This report is governed by, and incorporates by reference, CPS Conditions of Service as posted at the date of issuance of this report at
    http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/and is intended for your exclusive use. Any copying or replication
    of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth
    our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or
    characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes
    all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon
    request for accredited tests. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or
    if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A
    failure to raise such issue within the prescribed time shall constitute you unqualified acceptance of the completeness of this report, the tests conducted and
    the correctness of the report contents.




                                                     No. 34, Chenwulu Section, Guantai Rd., Houjie                Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                                     Town, Dongguan City,                                         Fax: +86 769 8593 1080
Dongguan Branch
                                                     Guangdong 523942, China                                      Email: customerservice.dg@cn.bureauveritas.com
                                                                           Page 1 of 7                                                               Report Version 1


                  Test Report No.: FM190628N080




                                    TABLE OF CONTENTS
   RELEASE CONTROL RECORD ................................................................................ 3
   1.       CERTIFICATION .............................................................................................. 4
   2.       RF EXPOSURE LIMIT ..................................................................................... 5
   3.       MPE CALCULATION FORMULA ..................................................................... 5
   4.       CLASSIFICATION ........................................................................................... 5
   5.       ANTENNA GAIN .............................................................................................. 6
   6.       CALCULATION RESULT OF MAXIMUM CONDUCTED POWER................... 6




                                         No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                         Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                         Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                           Page 2 of 7                                                   Report Version 1


                  Test Report No.: FM190628N080



                               RELEASE CONTROL RECORD

    ISSUE NO.                REASON FOR CHANGE                                                       DATE ISSUED

    FM190628N080             Original release                                                         Aug. 01, 2019




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                       Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                       Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                        Page 3 of 7                                                    Report Version 1


                  Test Report No.: FM190628N080



   1. CERTIFICATION

                     PRODUCT:       Smart Business Phone

                BRAND NAME:         ZULTYS

                   MODEL NO.:       ZIP 49GE

      ADDITIONAL MODEL:             N/A

                          FCC ID:   2APWA-ZIP49GE

               TEST SAMPLE:         ENGINEERING SAMPLE

                   APPLICANT:       Zultys, Inc.

             TESTED DATES:          Jun. 28, 2019 ~ Jul. 05, 2019

                 STANDARDS:         FCC Part 2 (Section 2.1091)
                                    KDB 447498 D01
                                    IEEE C95.1




                                    No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                    Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                    Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                     Page 4 of 7                                                    Report Version 1


                  Test Report No.: FM190628N080


   2. RF EXPOSURE LIMIT

   LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)
      FREQUENCY             ELECTRIC FIELD         MAGNETIC FIELD POWER DENSITY                           AVERAGE TIME
      RANGE (MHz)           STRENGTH (V/m)         STRENGTH (A/m)   (mW/cm2)                                (minutes)
                    LIMITS FOR GENERAL POPULATION / UNCONTROLLED EXPOSURE
         300-1500                   …                        …                     F/1500                           30
      1500-100,000                  …                        …                          1.0                         30

   F = Frequency in MHz


   3. MPE CALCULATION FORMULA
   Pd = (Pout*G) / (4*pi*r2)
   where
   Pd = power density in mW/cm2
   Pout = output power to antenna in mW
   G = gain of antenna in linear scale
   Pi = 3.1416
   R = distance between observation point and center of the radiator in cm




   4. CLASSIFICATION
   The antenna of this product, under normal use condition, is at least 20cm away from
   the body of the user. So, this device is classified as Mobile Device.




                                        No. 34, Chenwulu Section, Guantai Rd., Houjie     Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                        Town, Dongguan City,                              Fax: +86 769 8593 1080
Dongguan Branch
                                        Guangdong 523942, China                           Email: customerservice.dg@cn.bureauveritas.com
                                                         Page 5 of 7                                                      Report Version 1


                  Test Report No.: FM190628N080



   5. ANTENNA GAIN
        The antennas provided to the EUT, please refer to the following table:
                Frequency Band                      Antenna                              Antenna
                                                   Gain (dBi)                             Type

                    BT 2.4GHz                          3.31                          FPC Antenna

                   Wi-Fi 2.4GHz                        3.31                          FPC Antenna
                    Wi-Fi 5GHz
                                                       3.42                          FPC Antenna
                 (5150-5250MHz)
                    Wi-Fi 5GHz
                                                       3.42                          FPC Antenna
                 (5250-5350MHz)
                    Wi-Fi 5GHz
                                                       3.42                          FPC Antenna
                 (5500-5725MHz)
                    Wi-Fi 5GHz
                                                       3.42                          FPC Antenna
                 (5725-5850MHz)



   6. CALCULATION RESULT OF MAXIMUM CONDUCTED POWER

      The tuned conducted Average Power (declared by client)
                                                         Target                            Lower              Upper
                                    Frequency                           Tolerance
           Mode                                          Power                           Tolerance          Tolerance
                                      (MHz)                               (dBm)
                                                         (dBm)                             (dBm)              (dBm)
        BT (GFSK)             2402-2480MHz                  4                +-2              2                   6
       BT (8DPSK)             2402-2480MHz                  4                +-2              2                   6
      BT-LE (GFSK)            2402-2480MHz                  5                +-2              3                   7
          802.11b             2412-2462MHz                 14                +-3             11                  17
          802.11g             2412-2462MHz                 13                +-3             10                  16
       802.11n HT20           2412-2462MHz                 12                +-3              9                  15
       802.11n HT40           2422-2452MHz                 11                +-3              8                  14
    Wi-Fi 5GHz(Band1)         5150-5250MHz                  9                +-4              5                  13
    Wi-Fi 5GHz(Band2)         5250-5350MHz                 11                +-4              7                  15
    Wi-Fi 5GHz(Band3)         5500-5725MHz                 10                +-4              6                  16
    Wi-Fi 5GHz(Band4)         5725-5850MHz                  7                +-4              3                  11




                                         No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                         Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                         Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 6 of 7                                                    Report Version 1


    B U R E A U      Test Report No.: FM190628N080
    M3 y C




      The measured conducted Average Power

                                              Frequency                                Averaged Power
                  Mode                          (MHz)                                         (dBm)
            BT (GFSK)                            2480                                          3.18
           BT (8DPSK)                            2441                                          3.34
          BT—LE (GFSK)                           2480                                          6.12
              802.11b                            2412                                          15.06
              802.11g                            2437                                          13.97
          802.11n HT20                           2437                                          13.60
          802.11n HT4O                           2437                                          13.46

       Wi—Fi 5GHz(Band1)                         5200                                          10.84
       Wi—Fi 5GHz(Band2)                         5300                                          14.18
       Wi—Fi 5GHz(Band3)                         5600                                          11.61
       Wi—Fi 5GHz(Band4)                         5785                                          8.03



    FREQUENCY            |MAX AVERAGE|    ANTENNA                                     POWER
      BAND                  POWER           GAIN               DIS(-Z':‘“'\)ICE      DENSITY                (mI;II\II\/’I;-rI;nz)
       (MHz)                 (dBm)          (dBi)                                    (mW/cm?)

       BT 2.4GHz                7             3.31                    20             0.002137                      1.0

     Wi—Fi 2.4GHz              17             3.42                    20             0.021914                      1.0

      Wi—Fi 5GHz               16             3.42                    20             0.017407                      1.0




   CONCLUSION:
   The BT 2.4GHz and Wi—Fi can transmit simultaneously, the formula of calculated the
   MPE is:


   CPD1 / LPD1 + CPD2 / LPD2 + ...... etc. < 1
   CPD = Calculation power density
   LPD = Limit of power density

    (0.002137/1)+( 0.021914 /1) = 0.024051 <1, which is less than the "1" limit.


    ——— END ———
                                     No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                     Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                     Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com

                                                        Page 7 of 7                                                      Report Version 1



Document Created: 2019-08-01 15:47:09
Document Modified: 2019-08-01 15:47:09

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC