ROKK wireless Active 2APUSCCW04E MPE Test Report

FCC ID: 2APUPSCCW04E

RF Exposure Info

Download: PDF
FCCID_4176052

                     Report No.:UNIA19010802FR-01




       FCC MPE TEST REPORT

             FCC ID: 2APUPSCCW04E



               Product: ROKK wireless Active
           Trade Name: Scanstrut

          Model Name: SC-CW-04E

          Serial Model: SC-CW-04F, SC-CW-04G

            Report No.: UNIA19010802FR-01



                         Prepared for
                            Scanstrut Ltd.

         5 Darts Business Park, Clyst St. George, Exeter, United Kingdom




                          Prepared by
           Shenzhen United Testing Technology Co., Ltd.

2F, Annex Bldg, Jiahuangyuan Tech Park, #365 Baotian 1 Rd, Tiegang
      Community, Xixiang Str, Bao'an District, Shenzhen, China




                              Page1 / 8


                                                    Report No.:UNIA19010802FR-01



                                        TEST RESULT CERTIFICATION

Applicant’s name ............. : Scanstrut Ltd.
Address ............................. : 5 Darts Business Park, Clyst St. George, Exeter, United Kingdom
Manufacture's Name........ : Scanstrut Ltd.
Address ............................. : 5 Darts Business Park, Clyst St. George, Exeter, United Kingdom
Product description
Product name .................... : ROKK wireless Active
Trade Mark ............................ : Scanstrut
Model and/or type reference : SC-CW-04E,SC-CW-04F, SC-CW-04G
                                               FCC KDB 680106 D01 RF Exposure Wireless Charging
Standards ......................... :
                                               Apps v03
This device described above has been tested by Shenzhen United Testing Technology
Co., Ltd., and the test results show that the equipment under test (EUT) is in compliance
with the FCC requirements. And it is applicable only to the tested sample identified in the
report.
This report shall not be reproduced except in full, without the written approval of UNI, this
document may be altered or revised by Shenzhen United Testing Technology Co., Ltd.,
personnel only, and shall be noted in the revision of the document.

Date of Test ........................................... :
Date (s) of performance of tests............. :               Jan. 08, 2019 ~ Jan. 21, 2019
Date of Issue.......................................... :     Jan. 21, 2019
Test Result ............................................. :   Pass




Prepared by:
                                                                        Kahn yang/Editor


Reviewer:
                                                                     Sherwin Qian/Supervisor


Approved & Authorized Signer:
                                                                           Liuze/Manager




                                                               Page2 / 8


                                     Report No.:UNIA19010802FR-01

Note:For a more detailed features description, please refer to the manufacturer’sspecificationsor the
User'sManual.

                                           ChannelList
            Channel            Frequency(KHz)          Channel              Frequency(MHz)
              01                    125




         TheEUTantennaisCoilAntenna.Noantennaotherthanthatfurnishedbytheresponsibleparty
         shall be used with thedevice.


1. SUMMARY OF TESTRESULTS

1.1 Test procedures according to the technicalstandards:
    FCC KDB 680106 D01 RF Exposure Wireless Charging Appsv03


                                               FCC CFR 47

         Standard Section                    Test Item                  Judgment         Remark


                                  Electric Field Strength (E) (V/m)       PASS
       FCC CFR 47 part1,
       1.1310 KDB680106
          D01v03(3)(3)
                                  Magnetic Field Strength (H) (A/m)       PASS


1.2 MEASUREMENTUNCERTAINTY
   The reported uncertainty of measurement y ±U,where expended uncertainty U is based
   onastandard uncertainty multiplied by a coverage factor of k=2 , providing a level of
   confidenceofapproximately 95%。


            No.                                 Item                               Uncertainty

             1              Allemissions,radiated(<30M)(9KHz-30MHz)                 ±2.45dB

             2                              Temperature                              ±0.5°C

             3                                Humidity                                ±2%




                                              Page3 / 8


                                     Report No.:UNIA19010802FR-01

1.3 TestInstruments

         Description             Brand         Model No.      Frequency Range    Calibrated Until

   Broadband Field Meter        NARDA          NBM-550                  ––       Sep. 01, 2019

    Magnetic Field Meter        NARDA          ELT-400               1–400kHz    Sep. 01, 2019

      Magnetic Probe            NARDA          HF-3061         300kHz–30MHz      Sep. 01, 2019

      Magnetic Probe            NARDA          HF-0191             27–1000MHz    Sep. 01, 2019

   Broadband Field Meter        NARDA          NBM-550                  ––       Sep. 01, 2019

     Electric Field Meter    COMBINOVA         EFM 200              5Hz–400kHz   Sep. 01, 2019

       E-Field Probe            NARDA          EF-0391             100kHz–3GHz   Sep. 01, 2019

       E-Field Probe            NARDA          EF-6091         100MHz–60GHz      Sep. 01, 2019


 NOTE:Thecalibrationintervaloftheabovetestinstrumentsis12months.




                                              Page4 / 8


                                          Report No.:UNIA19010802FR-01


2. MAXIMUM PERMISSIBLEEXPOSURE

2.1 MAXIMUM PERMISSIBLEEXPOSURE

     Limit of Maximum PermissibleExposure

                                 Limits for Occupational / Controlled Exposure

                                                                                        Averaging Time
  FrequencyRange(M ElectricFieldStrengt          MagneticField       Power Density(S)
         Hz)           h (E)(V/m)              Strength (H)(A/m)        (mW/cm²)         |E|²,|H|² or S
                                                                                           (minutes)
         0.3-3.0                 614                  1.63                 (100)*              6
         3.0-30                1842 / f              4.89 / f            (900 / f)*            6
         30-300                  61.4                0.163                  1.0                6
       300-1500                                                            F/300               6
     1500-100,000                                                            5                 6
                             Limits for General Population / Uncontrolled Exposure

                                                                  Power                 AveragingTime
  FrequencyRange(M ElectricFieldStrengt MagneticFieldStreng
                                                            Density(S)(mW/cm²              |E|²,|H|²
         Hz)           h (E)(V/m)          th (H)(A/m)
                                                                     )                   orS(minutes)
        0.3-1.34                 614                  1.63                 (100)*             30
        1.34-30                 824/f                2.19/f              (180 / f)*           30
         30-300                  27.5                0.073                  0.2               30
       300-1500                                                           F/1500              30
     1500-100,000                                                            1                30
Note 1: f = frequency in MHz ; *Plane-wave equivalent power density.
     2: For the applicable limit, see FCC 1.1310, 680106 D01 RF Exposure Wireless Charging Apps v03.
     3: Emissions between 100 kHz to 300 kHz should be assessed versus the limits at 300 kHz in Table 1 of
     Section 1.1310: 614 V/m and 1.63 A/m. A KDB inquiry is required to determine the applicable exposure
     limits below 100 kHz.




                                                    Page5 / 8


                                 Report No.:UNIA19010802FR-01



3. TESTPROCEDURE
a. For devices designed for typical desktop applications, such a wireless charging
pads,RFexposure evaluation should be conducted assuming a user separation distance of 15
cm.
E and H field strength measurements or numerical modeling may be used
todemonstratecompliance. Measurements should be made from all sides and the top of
theprimary/clientpair, with the 15 cm measured from the center of the probe(s) to the edge of
thedevice.

4.1 TESTSETUP




4.2 TESTPHOTO




                                          Page6 / 8


                                  Report No.:UNIA19010802FR-01




4.3 RESULT OF MAXIMUM PERMISSIBLEEXPOSURE

For Full load mode:
E-Filed Strength at 15 cm from the edges surrounding the EUT (V/m)
 Frequency        Test        Test        Test        Test      Test Reference Limits Test
Range (MHz) Position A Position B Position C Position D Position E Limit (V/m) (V/m)
   0.125        1.24       1.02         1.13           1.14      1.17   307        614

H-Filed Strength at 15 cm from the edges surrounding the EUT (A/m)
 Frequency        Test        Test        Test        Test      Test Reference Limits Test
Range (MHz) Position A Position B Position C Position D Position E Limit (A/m) (A/m)
   0.125        0.25       0.19         0.25           0.15      0.17   0.815     1.63

For Half Load for wrist band mode:
E-Filed Strength at 15 cm from the edges surrounding the EUT (V/m)
 Frequency        Test        Test        Test        Test      Test Reference Limits Test
Range (MHz) Position A Position B Position C Position D Position E Limit (V/m) (V/m)
   0.125        1.16       1.19         1.18           1.18      1.14   307        614

H-Filed Strength at 15 cm from the edges surrounding the EUT (A/m)
 Frequency        Test        Test        Test        Test      Test Reference Limits Test
Range (MHz) Position A Position B Position C Position D Position E Limit (A/m) (A/m)
   0.125        0.19       0.20         0.20           0.22      0.17   0.815     1.63




                                           Page7 / 8


                                  Report No.:UNIA19010802FR-01




For Half Load for shoepodmode:
E-Filed Strength at 15 cm from the edges surrounding the EUT(V/m)
 Frequency        Test        Test        Test        Test      Test Reference Limits Test
Range (MHz) Position A Position B Position C Position D Position E Limit (V/m) (V/m)
   0.125        1.18       1.18         1.21           1.19      1.18   307        614

H-Filed Strength at 15 cm from the edges surrounding the EUT(A/m)
 Frequency        Test        Test        Test        Test      Test Reference Limits Test
Range (MHz) Position A Position B Position C Position D Position E Limit (A/m) (A/m)
   0.125        0.19       0.18         0.18           0.22      0.17   0.815     1.63

For No loadmode:
E-Filed Strength at 15 cm from the edges surrounding the EUT(V/m)
 Frequency        Test        Test        Test        Test      Test Reference Limits Test
Range (MHz) Position A Position B Position C Position D Position E Limit (V/m) (V/m)
   0.125        1.21       1.14         1.25           1.22      1.18   307        614

H-Filed Strength at 15 cm from the edges surrounding the EUT(A/m)
 Frequency        Test        Test        Test        Test      Test Reference Limits Test
Range (MHz) Position A Position B Position C Position D Position E Limit (A/m) (A/m)
   0.125        0.19       0.18         0.18           0.19      0.20   0.815     1.63


                              ※※※※※※THEEND※※※※※※




                                           Page8 / 8



Document Created: 2019-02-18 08:38:12
Document Modified: 2019-02-18 08:38:12

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC