MPE_Test_Report

FCC ID: 2APUPSCCW01

RF Exposure Info

Download: PDF
FCCID_4024827

       FCC MPE TEST REPORT

              FCC ID: 2APUPSCCW01

               Product: ROKK wireless charger
           Trade Name: Scanstrut
          Model Name: SC-CW-01
                        SC-CW-01E, SC-CW-02, SC-CW-02E,
          Serial Model:
                        SC-CW-03, SC-CW-03E
           Report No.: UNIA2018091310-2FR-01



                         Prepared for
                          Scanstrut Ltd.

   5 Darts Business Park, Clyst St. George, Exeter, United Kingdom



                         Prepared by
           Shenzhen United Testing Technology Co., Ltd.
2F, Annex Bldg, Jiahuangyuan Tech Park, #365 Baotian 1 Rd, Tiegang
     Community, Xixiang Str, Bao'an District, Shenzhen, China




                            Page 1 / 8


                                           TEST RESULT CERTIFICATION

Applicant’s name ............. : Scanstrut Ltd.
                                         5 Darts Business Park, Clyst St. George, Exeter, United
Address .............................. : Kingdom
Manufacture's Name ........ : Scanstrut Ltd.
                                         5 Darts Business Park, Clyst St. George, Exeter, United
Address .............................. : Kingdom
Product description
Product name..................... : ROKK wireless charger
Model name ............................ : SC-CW-01
Serial Model ....................... : SC-CW-01E, SC-CW-02, SC-CW-02E, SC-CW-03,
                                          SC-CW-03E
                                          FCC KDB 680106 D01 RF Exposure Wireless Charging
Standards ......................... :
                                          Apps v03
This device described above has been tested by Shenzhen United Testing Technology
Co., Ltd., and the test results show that the equipment under test (EUT) is in compliance
with the FCC requirements. And it is applicable only to the tested sample identified in the
report.
This report shall not be reproduced except in full, without the written approval of UNI, this
document may be altered or revised by Shenzhen United Testing Technology Co., Ltd.,
personnel only, and shall be noted in the revision of the document.
Date of Test .............................................. :
Date (s) of performance of tests .............. :                 May 08, 2018 ~ May 18, 2018
Date of Issue............................................. :      Sep. 28, 2018
Test Result ................................................. :   Pass




Prepared by:
                                                                         Kahn yang/Editor


Reviewer:
                                                                    Sherwin Qian/Supervisor


Approved & Authorized Signer:
                                                                          Liuze/Manager




                                                                  Page 2 / 8


Note: For a more detailed features description, please refer to the manufacturer’s specifications or
the User's Manual.

                                           Channel List
            Channel            Frequency(KHz)           Channel             Frequency(MHz)
              01                    125




         The EUT antenna is Coil Antenna. No antenna other than that furnished by the responsible
         party shall be used with the device.


1. SUMMARY OF TEST RESULTS

1.1 Test procedures according to the technical standards:
    FCC KDB 680106 D01 RF Exposure Wireless Charging Apps v03


                                                 FCC CFR 47

         Standard Section                       Test Item                Judgment         Remark


                                   Electric Field Strength (E) (V/m)      PASS
        FCC CFR 47 part1,
        1.1310 KDB680106
           D01 v03(3)(3)
                                  Magnetic Field Strength (H) (A/m)       PASS


1.2 MEASUREMENT UNCERTAINTY
   The reported uncertainty of measurement y ±U,where expended uncertainty U is based on a
   standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of
   approximately 95 %。


            No.                                   Item                              Uncertainty

             1              All emissions,radiated(<30M)(9KHz-30MHz)                 ±2.45dB

             2                               Temperature                              ±0.5°C

             3                                  Humidity                               ±2%




                                              Page 3 / 8


1.3 Test Instruments

         Description               Brand          Model No.        Frequency Range   Calibrated Until

   Broadband Field Meter          NARDA            NBM-550                    ––     Jan. 01, 2019

    Magnetic Field Meter          NARDA            ELT-400             1–400kHz      Jan. 01, 2019

       Magnetic Probe             NARDA            HF-3061          300kHz–30MHz     Jan. 01, 2019

       Magnetic Probe             NARDA            HF-0191           27–1000MHz      Jan. 01, 2019

   Broadband Field Meter          NARDA            NBM-550                    ––     Jan. 01, 2019

     Electric Field Meter      COMBINOVA           EFM 200            5Hz–400kHz     Jan. 01, 2019

        E-Field Probe             NARDA            EF-0391           100kHz–3GHz     Jan. 01, 2019

        E-Field Probe             NARDA            EF-6091          100MHz–60GHz     Jan. 01, 2019


 NOTE: The calibration interval of the above test instruments is 12 months.




                                                Page 4 / 8


2. MAXIMUM PERMISSIBLE EXPOSURE

2.1 MAXIMUM PERMISSIBLE EXPOSURE

     Limit of Maximum Permissible Exposure

                                 Limits for Occupational / Controlled Exposure

                                                                                        Averaging Time
   Frequency Range         Electric Field        Magnetic Field     Power Density (S)
        (MHz)           Strength (E) (V/m)     Strength (H) (A/m)      (mW/ cm²)         |E|²,|H|²or S
                                                                                           (minutes)
         0.3-3.0                 614                  1.63                 (100)*             6
         3.0-30                1842 / f              4.89 / f            (900 / f)*           6
         30-300                  61.4                0.163                  1.0               6
       300-1500                                                            F/300              6
     1500-100,000                                                            5                6
                             Limits for General Population / Uncontrolled Exposure

   Frequency Range         Electric Field       Magnetic Field      Power Density (S)   Averaging Time
        (MHz)           Strength (E) (V/m)     Strength (H) (A/m)      (mW/ cm²)         |E|²,|H|²or S
                                                                                           (minutes)
        0.3-1.34                 614                  1.63                (100)*              30
        1.34-30                  824/f               2.19/f              (180 / f)*           30
         30-300                  27.5                0.073                  0.2               30
       300-1500                                                           F/1500              30
     1500-100,000                                                            1                30
Note 1: f = frequency in MHz ; *Plane-wave equivalent power density.
     2: For the applicable limit, see FCC 1.1310, 680106 D01 RF Exposure Wireless Charging Apps v03.
     3: Emissions between 100 kHz to 300 kHz should be assessed versus the limits at 300 kHz in Table 1 of
     Section 1.1310: 614 V/m and 1.63 A/m. A KDB inquiry is required to determine the applicable exposure
     limits below 100 kHz.




                                                   Page 5 / 8


3. TEST PROCEDURE
a. For devices designed for typical desktop applications, such a wireless charging pads, RF
exposure evaluation should be conducted assuming a user separation distance of 15 cm.
E and H field strength measurements or numerical modeling may be used to demonstrate
compliance. Measurements should be made from all sides and the top of the primary/client
pair, with the 15 cm measured from the center of the probe(s) to the edge of the device.

4.1 TEST SETUP




4.2 TEST PHOTO




                                         Page 6 / 8


4.3 RESULT OF MAXIMUM PERMISSIBLE EXPOSURE

For Full load mode:
E-Filed Strength at 15 cm from the edges surrounding the EUT (V/m)
 Frequency        Test        Test        Test        Test      Test Reference Limits Test
Range (MHz) Position A Position B Position C Position D Position E Limit (V/m) (V/m)
   0.125        1.22       1.16       1.21          1.18    1.20       184.2       614

H-Filed Strength at 15 cm from the edges surrounding the EUT (A/m)
 Frequency        Test       Test         Test        Test      Test Reference Limits Test
Range (MHz) Position A Position B Position C Position D Position E Limit (A/m) (A/m)
   0.125        0.22       0.20       0.24          0.18    0.19       0.489      1.63

For Half Load for wrist band mode:
E-Filed Strength at 15 cm from the edges surrounding the EUT (V/m)
 Frequency        Test        Test        Test        Test      Test Reference Limits Test
Range (MHz) Position A Position B Position C Position D Position E Limit (V/m) (V/m)
   0.125        1.18       1.15       1.20          1.17    1.16       184.2       614

H-Filed Strength at 15 cm from the edges surrounding the EUT (A/m)
 Frequency        Test       Test         Test        Test      Test Reference Limits Test
Range (MHz) Position A Position B Position C Position D Position E Limit (A/m) (A/m)
   0.125        0.18       0.20       0.18          0.20    0.21       0.489      1.63




                                       Page 7 / 8


For Half Load for shoepod mode:
E-Filed Strength at 15 cm from the edges surrounding the EUT (V/m)
 Frequency        Test        Test        Test        Test      Test Reference Limits Test
Range (MHz) Position A Position B Position C Position D Position E Limit (V/m) (V/m)
   0.125        1.16       1.21       1.22          1.20    1.22       184.2       614

H-Filed Strength at 15 cm from the edges surrounding the EUT (A/m)
 Frequency        Test       Test         Test        Test      Test Reference Limits Test
Range (MHz) Position A Position B Position C Position D Position E Limit (A/m) (A/m)
   0.125        0.20       0.22       0.18          0.18    0.20       0.489      1.63

For No load mode:
E-Filed Strength at 15 cm from the edges surrounding the EUT (V/m)
 Frequency        Test        Test        Test        Test      Test Reference Limits Test
Range (MHz) Position A Position B Position C Position D Position E Limit (V/m) (V/m)
   0.125        1.17       1.20       1.19          1.21    1.18       184.2       614

H-Filed Strength at 15 cm from the edges surrounding the EUT (A/m)
 Frequency        Test       Test         Test        Test      Test Reference Limits Test
Range (MHz) Position A Position B Position C Position D Position E Limit (A/m) (A/m)
   0.125        0.20       0.20       0.18          0.16    0.16       0.489      1.63


                                  ※※※※※THE END※※※※※




                                       Page 8 / 8



Document Created: 2018-09-28 14:39:44
Document Modified: 2018-09-28 14:39:44

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC