                  RF Exposure Evaluation Report

Report No. :                          CQASZ20190600033EX—02

Applicant:                            JMTek Industries(Shenzhen) Co., Ltd.

Address of Applicant:                 14G, Innovation Tech Building, Quanzhi Science and Technology innovation
                                      Park, ShaJing Street, Bacan District, ShenZhen, China
Manufacturer:                         JMTek Industries(Shenzhen) Co., Ltd.
Address of Manufacturer:              14G, Innovation Tech Building, Quanzhi Science and Technology innovation
                                      Park, ShaJing Street, Bacan District, ShenZhen, China

Equipment Under Test (EUT):
Product:                  Wireless Charger
Model No.:                WPC488—10W
Brand Name:               N/A
FCC ID:                   2APUS—WPCA488—10W
Standards:                47 CFR Part 1.1307
                                      47 CFR Part 1.1310
                                      KDB 680106 D01 RF Exposure Wireless Charging Base App v03

Date of Test:                         Jun. 24, 2019 to Jun. 28, 2019
Date of Issue:                        Jul. 01, 2019
 Test Result :                        PASS*




Tested By:                                           To—Che
                                                   Accron /
                                                   /Tom Ch%


Reviewed By:
                                                          aron Ma)


Approved By:
                                                        ( Jack Ai)




* In the configuration tested, the EUT complied with the standards specified above.

The test report is effective only with both signature and specialized stamp, The result(s) shown in this reportrefer only to the sample(s)

tested. Without written approval of CQA, this report can‘t be reproduced except in full


                                     Shenzhen Huaxia Testing Technology Co., Ltd
                                                      Report No.: CQASZ20190600033EX-02


2   Version
                             Revision History Of Report

           Report No.          Version       Description           Issue Date
     CQASZ20190600033EX-02     Rev.01        Initial report       Jul. 01, 2019




                              Page:2 of 12


                                                                                 Shenzhen Huaxia Testing Technology Co., Ltd
                                                                                                                  Report No.: CQASZ20190600033EX-02



3         Contents
                                                                                                                                                                         Page
1       COVER PAGE .............................................................................................................................................................1

2       VERSION .....................................................................................................................................................................2

3       CONTENTS .................................................................................................................................................................3

4       GENERAL INFORMATION .......................................................................................................................................4
    4.1     CLIENT INFORMATION................................................................................................................................................4
    4.2     GENERAL DESCRIPTION OF EUT ................................................................................................................................4
    4.3     TEST ENVIRONMENT..................................................................................................................................................5
    4.4     DESCRIPTION OF SUPPORT UNITS ...............................................................................................................................5
    4.5     TEST LOCATION .........................................................................................................................................................6
    4.6     TEST FACILITY ...........................................................................................................................................................6
    4.7     EQUIPMENT LIST ........................................................................................................................................................6
5       RF EXPOSURE EVALUATION ................................................................................................................................7
    5.1 RF EXPOSURE COMPLIANCE REQUIREMENT ..............................................................................................................7
       5.1.1 Limits ..............................................................................................................................................................7
       5.1.2 Test Procedure ..............................................................................................................................................7
       5.1.3 Test Setup......................................................................................................................................................8
       5.1.4 Test Results ...................................................................................................................................................8
APPENDIX A: PHOTOGRAPHS OF TEST SETUP .....................................................................................................12




                                                                    Page:3 of 12


                                                 Shenzhen Huaxia Testing Technology Co., Ltd
                                                                    Report No.: CQASZ20190600033EX-02



4     General Information
4.1 Client Information
      Applicant:                   JMTek Industries(Shenzhen) Co., Ltd.
      Address of Applicant:        14G, Innovation Tech Building, Quanzhi Science and Technology
                                   innovation Park, ShaJing Street, Baoan District, ShenZhen, China
      Manufacturer:                JMTek Industries(Shenzhen) Co., Ltd.
      Address of Manufacturer:     14G, Innovation Tech Building, Quanzhi Science and Technology
                                   innovation Park, ShaJing Street, Baoan District, ShenZhen, China

4.2 General Description of EUT
     Product Name:                 Wireless Charger
     Model No.:                    WPC488-10W
     Trade Mark:                   N/A
     Hardware Version:             /
     Software Version:             /
     Operation Frequency:          172.2KHz
     Modulation Type:              Induction
     Antenna Type:                 Loop coil antenna
     Antenna Gain:                 0 dBi
                                   Input: 5V 2A; 9V      1.67A

     Charger Information:          Wireless Output: 5V    1A(5W), 9V      1.1A(10W)
                                   USB Output: 5V      1A Max


Note: For more detailed features description, please refer to the manufacturer’s specifications or the User's
Manual.




                                         Page:4 of 12


                                                  Shenzhen Huaxia Testing Technology Co., Ltd
                                                                   Report No.: CQASZ20190600033EX-02




4.3 Test Environment
     Operating Environment:
     Temperature:                25.0 C
     Humidity:                   53 % RH
     Atmospheric Pressure:       1001mbar
     Test Mode:
     Mode a:                     Wireless charging Mode at 9V (Full load)
     Mode b:                     Wireless charging Mode at 9V (half load)
     Mode c:                     Wireless charging Mode at 9V (Null load)
     Mode d:                     Wireless charging Mode at 5V (Full load)
     Mode e:                     Wireless charging Mode at 5V (half load)
     Mode f:                     Wireless charging Mode at 5V (Null load)

4.4 Description of Support Units
     The EUT has been tested with associated equipment below.

   Description        Manufacturer              Model No.            emark          FCC certification
     Adapter            Samsung               EP-TA50CBC        Provide by client     Verification

     Adapter            HUAWEI               HW-050450C00       Provide by client     Verification

Wireless electronic
                             -                      -           Provide by client           -
       Load




                                           Page:5 of 12


                                              Shenzhen Huaxia Testing Technology Co., Ltd
                                                                  Report No.: CQASZ20190600033EX-02




4.5 Test Location
     Shenzhen Huaxia Testing Technology Co., Ltd,

     1F., Block A of Tongsheng Technology Building, Huahui Road, Dalang Street, Longhua District,
     Shenzhen, China


4.6 Test Facility
    • A2LA (Certificate No. 4742.01)
    Shenzhen Huaxia Testing Technology Co., Ltd., Shenzhen EMC Laboratory is accredited by the
     American Association for Laboratory Accreditation(A2LA). Certificate No. 4742.01.
    • FCC Registration No.: 522263
    Shenzhen Huaxia Testing Technology Co., Ltd., Shenzhen EMC Laboratory has been registered and
    fully described in a report filed with the (FCC) Federal Communications Commission. The acceptance
    letter from the FCC is maintained in our files. Registration No.:522263




4.7 Equipment List

                                                                Instrument   Calibration   Calibration
  Test Equipment     Manufacturer           Model No.               No.        Date        Due Date
                        Narda
  Broadband Field     Safety Test
                                            NBM-520              SB9873      2018/10/18    2019/10/17
       Meter           Solutions
                        GmbH
   Magnetic field
                         HIOKI                3470              SB9058/04    2018/12/14    2019/12/13
      probe




                                       Page:6 of 12


                                                  Shenzhen Huaxia Testing Technology Co., Ltd
                                                                       Report No.: CQASZ20190600033EX-02



5       RF Exposure Evaluation

5.1    RF Exposure Compliance Requirement
5.1.1 Limits
        According to FCC Part1.1310: The criteria listed in the following table shall be used to evaluate the
        environment impact of human exposure to radio frequency (RF) radiation as specified in part1.1307(b)




Note 1: f = frequency in MHz ; *Plane-wave equivalent power density
Note 2: For the applicable limit, see FCC 1.1310, 680106 D01 RF Exposure Wireless Charging Apps v03
Note 3: Emissions between 100 kHz to 300 kHz should be assessed versus the limits at 300 kHz in Table 1 of
Section 1.1310: 614 V/m and 1.63 A/m. A KDB inquiry is required to determine the applicable exposure limits
below 100 kHz.
Note 4: The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface
from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit .

5.1.2 Test Procedure
For devices designed for typical desktop applications, such a wireless charging pads, RF exposure evaluation
should be conducted assuming a user separation distance of 20 cm(Top) and 15cm(Edge). E and H field
strength measurements or numerical modeling may be used to demonstrate compliance. Measurements
should be made from all sides and the top of the primary/client pair, with the 20 cm(Top) and 15cm(Edge)
measured from the center of the probe(s) to the edge of the device.




                                           Page:7 of 12


                                                  Shenzhen Huaxia Testing Technology Co., Ltd
                                                                      Report No.: CQASZ20190600033EX-02




5.1.3 Test Setup




Note: Position A: Front of EUT; Position B: Left of EUT; Position C: back of EUT; Position D: Right of EUT;
Position E: Top of EUT(20 cm measure distance);


5.1.4 Test Results

The EUT does comply with item 5 KDB680106 D01 v03.

(1) Power transfer frequency is less than 1 MHz.
(Conform)

(2) Output power from each primary coil is less than or equal to 15 watts.
(Conform)

(3) The transfer system includes only single primary and secondary coils. This includes charging
systems that may have multiple primary coils and clients that are able to detect and allow coupling
only between individual pairs of coils.
(Conform)

(4) Client device is placed directly in contact with the transmitter.
(Conform)

(5) Mobile exposure conditions only (portable exposure conditions are not covered by this
exclusion).
(Conform)

(6) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top
surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE
limit.
(Conform)


                                          Page:8 of 12


                                                  Shenzhen Huaxia Testing Technology Co., Ltd
                                                                   Report No.: CQASZ20190600033EX-02




Test condition: Mode a
E-field strength test result:

Frequency              Probe        Probe             Probe         Probe        Probe         Limit
                       Position A   Position B        Position C    Position D   Position E
Range                                                                                          (V/m)
                       (V/m)        (V/m)             (V/m)         (V/m)        (V/m)

172.2KHz               0.19         0.20              0.18          0.18         2.15          614


H-field strength test result:

Frequency              Probe        Probe             Probe         Probe        Probe         Limit
                       Position A   Position B        Position C    Position D   Position E
Range                                                                                          (A/m)
                       (A/m)        (A/m)             (A/m)         (A/m)        (A/m)

172.2KHz               0.08         0.11              0.10          0.11         0.72          1.63


Test condition: Mode b
E-field strength test result:

Frequency              Probe        Probe             Probe         Probe        Probe         Limit
                       Position A   Position B        Position C    Position D   Position E
Range                                                                                          (V/m)
                       (V/m)        (V/m)             (V/m)         (V/m)        (V/m)

172.2KHz               0.11         0.14              0.15          0.16         0.89          614


H-field strength test result:

Frequency              Probe        Probe             Probe         Probe        Probe         Limit
                       Position A   Position B        Position C    Position D   Position E
Range                                                                                          (A/m)
                       (A/m)        (A/m)             (A/m)         (A/m)        (A/m)

172.2KHz               0.10         0.14              0.08          0.10         0.70          1.63




                                           Page:9 of 12


                                                 Shenzhen Huaxia Testing Technology Co., Ltd
                                                                 Report No.: CQASZ20190600033EX-02




Test condition: Mode c
E-field strength test result:

Frequency              Probe        Probe           Probe         Probe        Probe         Limit
                       Position A   Position B      Position C    Position D   Position E
Range                                                                                        (V/m)
                       (V/m)        (V/m)           (V/m)         (V/m)        (V/m)

172.2KHz               0.08         0.12            0.07          0.08         0.59          614


H-field strength test result:

Frequency              Probe        Probe           Probe         Probe        Probe         Limit
                       Position A   Position B      Position C    Position D   Position E
Range                                                                                        (A/m)
                       (A/m)        (A/m)           (A/m)         (A/m)        (A/m)

172.2KHz               0.07         0.12            0.11          0.12         0.75          1.63




Test condition: Mode d
E-field strength test result:

Frequency              Probe        Probe           Probe         Probe        Probe         Limit
                       Position A   Position B      Position C    Position D   Position E
Range                                                                                        (V/m)
                       (V/m)        (V/m)           (V/m)         (V/m)        (V/m)

172.2KHz               0.09         0.09            0.10          0.11         0.90          614


H-field strength test result:

Frequency              Probe        Probe           Probe         Probe        Probe         Limit
                       Position A   Position B      Position C    Position D   Position E
Range                                                                                        (A/m)
                       (A/m)        (A/m)           (A/m)         (A/m)        (A/m)

172.2KHz               0.09         0.07            0.11          0.06         0.67          1.63




                                        Page:10 of 12


                                                 Shenzhen Huaxia Testing Technology Co., Ltd
                                                                 Report No.: CQASZ20190600033EX-02




Test condition: Mode e
E-field strength test result:

Frequency              Probe        Probe           Probe         Probe        Probe         Limit
                       Position A   Position B      Position C    Position D   Position E
Range                                                                                        (V/m)
                       (V/m)        (V/m)           (V/m)         (V/m)        (V/m)

172.2KHz               0.11         0.11            0.08          0.11         0.92          614


H-field strength test result:

Frequency              Probe        Probe           Probe         Probe        Probe         Limit
                       Position A   Position B      Position C    Position D   Position E
Range                                                                                        (A/m)
                       (A/m)        (A/m)           (A/m)         (A/m)        (A/m)

172.2KHz               0.09         0.08            0.06          0.10         0.65          1.63


Test condition: Mode f
E-field strength test result:

Frequency              Probe        Probe           Probe         Probe        Probe         Limit
                       Position A   Position B      Position C    Position D   Position E
Range                                                                                        (V/m)
                       (V/m)        (V/m)           (V/m)         (V/m)        (V/m)

172.2KHz               0.15         0.13            0.13          0.09         0.90          614


H-field strength test result:

Frequency              Probe        Probe           Probe         Probe        Probe         Limit
                       Position A   Position B      Position C    Position D   Position E
Range                                                                                        (A/m)
                       (A/m)        (A/m)           (A/m)         (A/m)        (A/m)

172.2KHz               0.11         0.06            0.08          0.09         0.67          1.63