Test Report

FCC ID: 2APSM-P14008

Test Report

Download: PDF
FCCID_3868274

                                   TEST REPORT
 Reference No.                 :   WTS18S05110481-1W

 FCC ID                        :   2APSM-P14008

 Applicant                     :   Shenzhen ZiZaiTao Technology Co.,Ltd
                                   Unit 1107, Petroleum Building, Huaqiang Road South, Futian District,
 Address                       :
                                   Shenzhen, Guangdong,China
 Manufacturer                  :   Shenzhen ZiZaiTao Technology Co.,Ltd
                                   Unit 1107, Petroleum Building, Huaqiang Road South, Futian District,
 Address                       :
                                   Shenzhen, Guangdong,China
 Product                       :   WIRELESS CHARGER

 Model(s)                      :   P14008

 Standards                     :   FCC Part 15 subpart C

 Date of Receipt sample        :   2018-05-4

 Date of Test                  :   2018-05-7 to 2018-05-17

 Date of Issue                 :   2018-05-21

 Test Result                   :   Pass


 Remarks:
 The results shown in this test report refer only to the sample(s) tested, this test report cannot be
 reproduced, except in full, without prior written permission of the company. The report would be invalid
 without specific stamp of test institute and the signatures of compiler and approver.

                                              Prepared By:
                                 Waltek Services (Shenzhen) Co., Ltd.
    Address: 1/F., Fukangtai Building, West Baima Road, Songgang Street, Baoan District, Shenzhen,
                                           Guangdong, China
                                         Tel :+86-755-83551033
                                         Fax:+86-755-83552400

      Compiled by:                                               Approved by:




      Jack Wen / Test Engineer                                   Philo Zhong / Manager




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn                          Page 1 of 19


Reference No.: WTS18S05110481-1W                                                  Page 2 of 19



2     Contents
                                                                                                                                                              Page
1    COVER PAGE ...................................................................................................................................... 1

2    CONTENTS ....................................................................................................................................................... 2

3    REVISION HISTORY ....................................................................................................................................... 3

4    LABORATORIES INTRODUCTION .............................................................................................................. 4
     4.1          TEST FACILITY ....................................................................................................................................... 5
5    TEST SUMMARY ............................................................................................................................................. 6

6    GENERAL INFORMATION ............................................................................................................................. 7
     6.1          GENERAL DESCRIPTION OF E.U.T ........................................................................................................ 7
7    EQUIPMENT USED DURING TEST ............................................................................................................. 8
     7.1          EQUIPMENTS LIST ................................................................................................................................. 8
     7.2          DESCRIPTION OF SUPPORT UNITS........................................................................................................ 8
     7.3          MEASUREMENT UNCERTAINTY.............................................................................................................. 9
     7.4          TEST EQUIPMENT CALIBRATION ........................................................................................................... 9
8    CONDUCTED EMISSION ............................................................................................................................. 10
     8.1          E.U.T. OPERATION.............................................................................................................................. 10
     8.2          EUT SETUP ......................................................................................................................................... 10
     8.3          MEASUREMENT DESCRIPTION ............................................................................................................ 10
     8.4          CONDUCTED EMISSION TEST RESULT ................................................................................................ 11
9    RADIATED SPURIOUS EMISSIONS .......................................................................................................... 13
     9.1          EUT OPERATION ................................................................................................................................. 13
     9.2          TEST SETUP ........................................................................................................................................ 14
     9.3          SPECTRUM ANALYZER SETUP ............................................................................................................ 15
     9.4          TEST PROCEDURE............................................................................................................................... 15
     9.5          SUMMARY OF TEST RESULTS ............................................................................................................. 16
10   BANDWIDTH MEASUREMENT................................................................................................................... 17
     10.1         TEST PROCEDURE............................................................................................................................... 17
     10.2         TEST RESULT PLOT: ........................................................................................................................... 17
11   ANTENNA REQUIREMENT ......................................................................................................................... 18

12   PHOTOGRAPHS OF TEST SETUP AND EUT. ........................................................................................ 19




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


  Reference No.: WTS18S05110481-1W                  Page 3 of 19


  3    Revision History
                        Date of
                                        Date of    Date of
  Test report No.       Receipt                                    Purpose    Comment   Approved
                                         Test       Issue
                        sample
                                    2018-05-
                                      04 to
WTS18S05110482E       2018-05-04                  2018-05-21       original      -       Valid
                                    2018-05-
                                       17




  Waltek Services (Shenzhen) Co.,Ltd.
  http://www.waltek.com.cn                         Page 3 of 19


Reference No.: WTS18S05110481-1W                        Page 4 of 19


4     Laboratories Introduction
     Waltek Services (Shenzhen) Co., Ltd is a professional third-party testing and certification laboratory
with multi-year product testing and certification experience, established strictly in accordance with ISO/IEC
17025 requirements, and accredited by ILAC (International Laboratory Accreditation Cooperation) member.
A2LA (American Association for Laboratory Accreditation) of USA, Meanwhile, Waltek has got recognition
as registration and accreditation laboratory from EMSD (Electrical and Mechanical Services Department),
and American Energy star, FCC(The Federal Communications Commission), CEC(California energy
efficiency), IC(Industry Canada). It’s the strategic partner and data recognition laboratory of international
authoritative organizations, such as Intertek(ETL-SEMKO), TÜV Rheinland, TÜV SÜD, etc.




     Waltek Services (Shenzhen) Co., Ltd is one of the largest and the most comprehensive third party
testing laboratory in China. Our test capability covered four large fields: safety test. ElectroMagnetic
Compatibility(EMC), and energy performance, wireless radio. As a professional, comprehensive, justice
international test organization, we still keep the scientific and rigorous work attitude to help each client
satisfy the international standards and assist their product enter into globe market smoothly.




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTS18S05110481-1W                 Page 5 of 19



4.1 Test Facility
      A. Accreditations for Conformity Assessment (International)
      Country/Region        Accreditation Body           Scope                Note
      USA                                                FCC ID \ DOC \ VOC   1
      Canada                                             IC ID \ VOC          2
      Japan                                              MIC-T \ MIC-R        -
                            A2LA
      Europe                                             EMCD \ RED           -
                            (Certificate No.: 4243.01)
      Taiwan                                             NCC                  -
      Hong Kong                                          OFCA                 -
      Australia                                          RCM                  -
      India                                              WPC                  -
      Thailand              International Services       NTC                  -
      Singapore                                          IDA                  -
      Note:
      1.   FCC Designation No.: CN1201. Test Firm Registration No.: 523476.
      2.   IC Canada Registration No.: 7760A

      B.TCBs and Notify Bodies Recognized Testing Laboratory.


      Recognized Testing Laboratory of …                 Notify body number
      TUV Rheinland
      Intertek
                                                         Optional.
      TUV SUD
      SGS
      Phoenix Testlab GmbH                               0700
      Element Materials Technology Warwick Ltd           0891
      Timco Engineering, Inc.                            1177
      Eurofins Product Service GmbH                      0681




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTS18S05110481-1W         Page 6 of 19



5     Test Summary
                    Test Items                Test Requirement   Result

               Conducted Emissions                  15.207       PASS

           Radiated Spurious Emissions              15.209       PASS
               Occupied Bandwidth                   15.215       PASS
              Antenna Requirement                   15.203       PASS




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTS18S05110481-1W                 Page 7 of 19



6     General Information

6.1 General Description of E.U.T
      Product:                    WIRELESS CHARGER
      Model(s):                   P14008
      Model Difference:           N/A
      Type of Modulation:         ASK
      Frequency Range:            0.112~0.205MHz

      Antenna installation:       Coil Antenna

      Antenna gain:               0dBi

      Input:                      5V     2A




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


        Reference No.: WTS18S05110481-1W                           Page 8 of 19



        7       Equipment Used during Test
        7.1 Equipments List
Conducted Emissions Test Site
                                                                                             Last
                                                                                                           Calibration
 Item           Equipment           Manufacturer           Model No.        Serial No.    Calibration
                                                                                                            Due Date
                                                                                             Date
  1.         EMI Test Receiver            R&S                  ESCI           100947      2017-09-12        2018-09-11
  2.               LISN                   R&S                 ENV216          101215      2017-09-12        2018-09-11
  3.              Cable                   Top            TYPE16(3.5M)             -       2017-09-12        2018-09-11
3m Semi-anechoic Chamber for Radiation Emissions Test site
                                                                                             Last
                                                                                                           Calibration
 Item           Equipment           Manufacturer           Model No.         Serial No    Calibration
                                                                                                            Due Date
                                                                                             Date
  1            Test Receiver              R&S                  ESCI           101296      2018-04-06        2019-04-05
  2         Active Loop Antenna       Beijing Dazhi        ZN30900A               -       2017-10-17        2018-10-16
             Trilog Broadband
  3                               SCHWARZBECK              VULB9160         9160-3325     2018-04-07        2019-04-06
                  Antenna
  4               Amplifier           ANRITSU                 MH648A         M43381       2018-04-07        2019-04-06
                                     Compliance
  5              Amplifier        pirection systems           PAP-0203        22024       2017-09-12        2018-09-11
                                          inc
  6               Cable           HUBER+SUHNER                 CBL2           525178      2018-04-07        2019-04-06
RF Conducted Testing
                                                                                             Last
                                                                                                           Calibration
 Item           Equipment           Manufacturer           Model No.        Serial No.    Calibration
                                                                                                            Due Date
                                                                                             Date
              EMC Analyzer
  1.                                     Agilent              E7405A       MY45114943     2017-09-15        2018-09-14
               (9k~26.5GHz)
            Spectrum Analyzer
  2.                                      R&S                  FSL6           100959      2017-09-15        2018-09-14
                (9k-6GHz)
              Signal Analyzer
  3.                                     Agilent              N9010A       MY50520207     2017-09-15        2018-09-14
               (9k~26.5GHz)
  4.        Humidity Chamber              GF            GTH-225-40-1P IAA061213           2017-09-15        2018-09-14
               Coaxial Cable
  5.                                        /                      /              /       2017-09-12        2018-09-11
              (10Hz-30GHz)
  6.        Antenna Connector*              /                      /              /       2017-09-12        2018-09-11

        7.2 Description of Support Units
                          Equipment                Manufacturer               Model No.                 Series No.

                          iPhone 5S                   Apple Inc.                  A1530                     /
                 Wireless Charger Receiver                /                           /                     /

        Waltek Services (Shenzhen) Co.,Ltd.
        http://www.waltek.com.cn


Reference No.: WTS18S05110481-1W                  Page 9 of 19



7.3 Measurement Uncertainty

             Test Item                Frequency Range            Uncertainty          Note

       Conducted Emissions             150kHz~30MHz               ±3.64dB              (1)
        Radiated Spurious
                                       26KHz~30MHz                ±3.03dB              (1)
           Emissions
        Radiated Spurious
                                      30MHz~1000MHz               ±5.03dB              (1)
           Emissions
     (1)This uncertainty represents an expanded uncertainty expressed at approximately the 95%
       confidence level using a coverage factor of k=2.

7.4 Test Equipment Calibration

      All the test equipments used are valid and calibrated by GUANG ZHOU GRG METROLOGY & TES
      T CO., LTD. address is No.163, Pingyun Rd. West of Huangpu Ave,Tianhe District, Guangzhou,
      Guangdong, China.




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTS18S05110481-1W                    Page 10 of 19



8     Conducted Emission

      Test Requirement:               FCC CFR 47 Part 15 Section 15.207
      Test Method:                    ANSI C63.10:2013
      Test Result:                    PASS
      Frequency Range:                150kHz to 30MHz
      Class/Severity:                 Class B
      Limit:                          66-56 dBµV between 0.15MHz & 0.5MHz
                                      56 dBµV between 0.5MHz & 5MHz
                                      60 dBµV between 5MHz & 30MHz
      Detector:                       Peak for pre-scan (9kHz Resolution Bandwidth)

8.1 E.U.T. Operation
     Operating Environment :
     Temperature:                     25.5 °C
     Humidity:                        51 % RH
     Atmospheric Pressure:            101.2kPa
     EUT Operation :                  Transmitting mode

     The test was performed in transmitting mode, the test data were shown in the report.

8.2 EUT Setup
      The EUT was placed on the test table in shielding room.



                  0.4m

                             EUT                                    Receiver    PC System

                  0.8m

                                                                                            0.8m

               LISN


                                                                          :50Ω Terminator


8.3 Measurement Description
     The maximised peak emissions from the EUT was scanned and measured for both the Live and
     Neutral Lines. Quasi-peak & average measurements were performed if peak emissions were within
     6dB of the average limit line.




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTS18S05110481-1W      Page 11 of 19



8.4 Conducted Emission Test Result

      Live line:




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTS18S05110481-1W      Page 12 of 19




    Neutral line:




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTS18S05110481-1W                     Page 13 of 19



9     Radiated Spurious Emissions
      Test Requirement:                 FCC CFR47 Part 15 Section 15.209
      Test Method:                      ANSI C63.10:2013
      Test Result:                      PASS
      Measurement Distance:             3m
      Limit:
      FCC Part15 Paragraph 15.209
                              Field Strength           Field Strength Limit at 3m Measurement Dist
         Frequency
                                          Distance
           (MHz)             uV/m                            uV/m                      dBuV/m
                                               (m)
                                                                                      (2400/F(kHz))
       0.009 ~ 0.490      2400/F(kHz)        300      10000 * 2400/F(kHz)      20log                  + 80
                                                                                    (24000/F(kHz))
       0.490 ~ 1.705   24000/F(kHz)            30     100 * 24000/F(kHz)      20log                   + 40
                                                                                          (30)
         1.705 ~ 30           30               30           100 * 30              20log          + 40
                                                                                             (100)
           30 ~ 88           100                3             100                     20log
                                                                                             (150)
          88 ~ 216           150                3             150                     20log
                                                                                             (200)
         216 ~ 960           200                3             200                     20log
                                                                                             (500)
         Above 960           500                3             500                     20log

9.1 EUT Operation

     Operating Environment :
     Temperature:                     23.5 °C
     Humidity:                        51.1 % RH
     Atmospheric Pressure:            101.2kPa
     EUT Operation :
     Only the worst case transmitting mode were record in the report.




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTS18S05110481-1W                  Page 14 of 19



9.2 Test Setup
      The radiated emission tests were performed in the 3m Semi- Anechoic Chamber test site, using the
      setup accordance with the ANSI C63.10: 2013.

      The test setup for emission measurement below 30MHz.




              Semi-anechoic 3m Chamber
              Turn Table From 0°to 360°




                                                        3m
                              EUT


                            Turn Table
           0.8m




                                  PC              Spectrum            AMP          Combining
                                System            Analyzer                          Network



      The test setup for emission measurement from 30 MHz to 1 GHz.



              Semi-anechoic 3m Chamber
              Antenna Elevation Varies From 1 to 4 m
              Turn Table From 0°to 360°
                                                        3m


                              EUT


           0.8m             Turn Table




                                 PC              Spectrum             AMP         Combining
                               System            Analyzer                          Network




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTS18S05110481-1W                             Page 15 of 19


9.3 Spectrum Analyzer Setup

          Below 30MHz
                           Sweep Speed .............................................. Auto
                           IF Bandwidth ................................................ 10kHz
                           Video Bandwidth.......................................... 10kHz
                           Resolution Bandwidth.................................. 10kHz

          30MHz ~ 1GHz
                           Sweep Speed .............................................. Auto
                           Detector ..................................................... PK
                           Resolution Bandwidth .................................. 100kHz
                           Video Bandwidth.......................................... 300kHz
9.4 Test Procedure
      1. The EUT is placed on a turntable, which is 0.8m above ground plane.
      2. The turntable shall be rotated for 360 degrees to determine the position of maximum emission
        level.
      3. EUT is set 3m away from the receiving antenna, which is moved from 1m to 4m to find out the
        maximum emissions. The spectrum was investigated from the lowest radio frequency signal
        generated in the device, without going below 9 kHz, up to the tenth harmonic of the highest
        fundamental frequency or to 40 GHz, whichever is lower.
      4. Maximum procedure was performed on the six highest emissions to ensure EUT compliance.
      5. And also, each emission was to be maximized by changing the polarization of receiving antenna
        both horizontal and vertical.
      6. Repeat above procedures until the measurements for all frequencies are complete.
      7. The radiation measurements are tested under 3-axes(X, Y, Z) position(X denotes lying on the
        table, Y denotes side stand and Z denotes vertical stand). After pre-test, It was found that the
        worse radiation emission was get at the X position. So the data shown was the X position only.




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


   Reference No.: WTS18S05110481-1W                     Page 16 of 19



   9.5 Summary of Test Results
          Test Frequency: 9KHz ~ 30MHz, Note: Correct factor = Cable loss + Antenna factor

                                     Turn       RX Antenna                                   FCC Part 15. 209
             Receiver                                              Corrected     Corrected
Frequency               Detector     table
             Reading                                                    Factor   Amplitude
                                    Angle      Height      Polar                              Limit   Margin

                        (PK/QP                                                               (dBμV/
  (KHz)      (dBμV)                Degree        (m)       (H/V)        (dB)     (dBμV/m)               (dB)
                          /Ave)                                                                m)
 114.97       59.70       AVe        324         1.8         H          18.72     78.42      106.39    -27.97
 114.97       61.41       AVe        212         1.2         V          18.72     80.13      106.39    -26.26



          Test Frequency: 30MHz ~ 1GHz

                                     Turn       RX Antenna                                   FCC Part 15. 209
             Receiver                                              Corrected     Corrected
Frequency               Detector     table
             Reading                                                    Factor   Amplitude
                                    Angle      Height      Polar                             Limit    Margin

                        (PK/QP                                                               (dBμV
 (MHz)       (dBμV)                Degree        (m)       (H/V)        (dB)     (dBμV/m)              (dB)
                          /Ave)                                                               /m)
  34.16       34.50        QP        324         1.3         H          -14.30    20.20      40.00    -19.80
  34.16       33.86        QP        163         2.0         V          -14.30    19.56      40.00    -20.44
 223.53       32.74        QP        188         1.1         H          -13.58    19.16      46.50    -27.34
 223.53       41.83        QP        105         1.6         V          -13.58    28.25      46.50    -18.25
 521.47       36.17        QP        177         1.5         H          -5.63     30.54      46.50    -15.96
 521.47       38.61        QP        167         1.8         V          -5.63     32.98      46.50    -13.52




   Waltek Services (Shenzhen) Co.,Ltd.
   http://www.waltek.com.cn


Reference No.: WTS18S05110481-1W                    Page 17 of 19



10 Bandwidth Measurement
      Test Requirement:                               FCC CFR47 Part 15 Section 15.215
10.1 Test Procedure

      1. The transmitter shall be operated at its maximum carrier power measured under normal test
        conditions;
      2. The span of the analyzer shall be set to capture all products of the modulation process,including
        the emission skirts.
      3. The resolution bandwidth (RBW) shall be in the range of 1% to 5% of the occupied bandwidth
        (OBW) and video bandwidth (VBW) shall be approximately 3x RBW.
10.2 Test Result Plot:
                                                                         20dB Bandwidth
                  Test Channel(kHz)         99% Bandwidth(kHz)
                                                                          Emission(KHz)
                          114.97                   2.275                       2.615

      Test result plot as follows:




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTS18S05110481-1W                     Page 18 of 19



11 Antenna Requirement
      According to the FCC Part 15 Paragraph 15.203, an intentional radiator shall be designed to ensure
      that no antenna other than that furnished by the responsible party shall be used with the device. The
      use of a permanently attached antenna to the intentional radiator shall be considered sufficient to
      comply with the provisions of this section. This product has a Coil antenna, fulfill the requirement of
      this section.




                                                               ANT




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTS18S05110481-1W                   Page 19 of 19



12 Photographs of test setup and EUT.
Refer to the file P14008_Ext Photos, P14008_Int Photos and P14008_Tsup Photos.




                                      ====== End of Report ======