14_SIREN TestRpt_NFC

FCC ID: 2APSE-SIREN

Test Report

Download: PDF
FCCID_4156840

                                           Shenzhen Anbotek Compliance Laboratory Limited
                      FCC ID: 2APSE-SIREN Page 1 of 29 Report No.: SZAWW181220002-03




                             FCC TEST REPORT
                                              For
                                         Roo Inc.
                                      Keypad Siren
 Model No.: SIREN, SIREN1, SIREN2, SIREN3, SIREN4,SIREN5, SIREN6, SIREN7, SIREN8,
                                      SIREN9




Prepared For      : Roo Inc.
Address           : 41 E 11th Street 10th Floor, New York City, New York, United States,
                     10003


Prepared By       : Shenzhen Anbotek Compliance Laboratory Limited
Address           : 1/F, Building D, Sogood Science and Technology Park, Sanwei
                     community, Hangcheng Street, Bao'an District, Shenzhen, Guangdong,
                     China.518102
                     Tel: (86) 755-26066440         Fax: (86) 755-26014772




Report Number     : SZAWW181220002-03
Date of Receipt   : Dec. 20, 2018
Date of Test      : Dec. 20, 2018~Jan. 08, 2019
Date of Report    : Jan. 08, 2019




                        Shenzhen Anbotek Compliance Laboratory Limited
      Tel:(86)755-26066440  Fax:(86)755-26014772    www.anbotek.com Code:AB-RF-05-a


                                                                Shenzhen Anbotek Compliance Laboratory Limited
                                           FCC ID: 2APSE-SIREN Page 2 of 29 Report No.: SZAWW181220002-03



                                                                       Contents
1. General Information..................................................................................................................................................4
     1.1. Client Information......................................................................................................................................... 4
     1.2. Description of Device (EUT)........................................................................................................................ 4
     1.3. Auxiliary Equipment Used During Test........................................................................................................ 4
     1.4. Description of Test Modes.............................................................................................................................5
     1.5. List of channels..............................................................................................................................................5
     1.7. Test Equipment List....................................................................................................................................... 7
     1.8. Measurement Uncertainty..............................................................................................................................8
     1.9. Description of Test Facility........................................................................................................................... 8
2. Test Procedure...........................................................................................................................................................9
3. Summary of Test Results........................................................................................................................................ 10
4. Conducted Emission Test........................................................................................................................................11
     4.1. Test Standard and Limit...............................................................................................................................11
     4.2. Test Setup.....................................................................................................................................................11
     4.3. Test Procedure..............................................................................................................................................11
     4.4. Test Data...................................................................................................................................................... 11
5. Radiation Spurious Emission..................................................................................................................................16
     5.1. Test Standard and Limit...............................................................................................................................16
     5.2. Test Setup.....................................................................................................................................................16
     5.3. Test Procedure..............................................................................................................................................17
     5.4. Test Data...................................................................................................................................................... 18
6. Frequency Tolerance...............................................................................................................................................22
     6.1. Test Standard and Limit...............................................................................................................................22
     6.2. Test Setup.....................................................................................................................................................22
     6.3. Test Procedure..............................................................................................................................................22
     6.4. Test Data...................................................................................................................................................... 22
7. 20dB Bandwidth..................................................................................................................................................... 24
     7.1. Test Standard and Limit...............................................................................................................................24
     7.2. Test Setup.....................................................................................................................................................24
     7.3. Test Procedure..............................................................................................................................................24
     7.4. Test Data...................................................................................................................................................... 24
8. Antenna Requirement............................................................................................................................................. 26
     8.1. Test Standard and Requirement................................................................................................................... 26
     8.2. Antenna Connected Construction................................................................................................................ 26
APPENDIX I -- TEST SETUP PHOTOGRAPH....................................................................................................... 27
APPENDIX II -- EXTERNAL PHOTOGRAPH....................................................................................................... 28
APPENDIX III -- INTERNAL PHOTOGRAPH.......................................................................................................29




                             Shenzhen Anbotek Compliance Laboratory Limited
           Tel:(86)755-26066440  Fax:(86)755-26014772    www.anbotek.com Code:AB-RF-05-a


  Anbotek                                               Shenzhen Anbotek Compliance Laboratory Limited
    Product Safety         FCC ID: 2APSE—SIREN Page 3 of 29 Report No.: SZAWW181220002—03



                                       TEST REPORT
Applicant                Roo Inc.

Manufacturer             Roo Inc.

Product Name             Keypad Siren
                          SIREN, SIREN1, SIREN2, SIREN3, SIREN4,SIRENS, SIREN6, SIRENT7, SIREN®,
Model No.
                          SIRENY

Trade Mark               Kangaroo

Rating(s)                Input: DC 5V, 2.4A(via adapter input: AC 100~240V, 50/60Hz, 0.4A)




Test Standard(s)          FCC Part15 Subpart C 2018, Section 15.225

Test Method(s)            ANSI €63.10: 2013

The device described above is tested by Shenzhen Anbotek Compliance Laboratory Limited to determine the
maximum emission levels emanating from the device and the severe levels of the device can endure and its
performance criterion. The measurement results are contained in this test report and Shenzhen Anbotek
Compliance Laboratory Limited is assumed full of responsibility for the accuracy and completeness of these
measurements. Also, this report shows that the EUT (Equipment Under Test) is technically compliant with the
FCC Part 15 Subpart C requirements.

This report applies to above tested sample only and shall not be reproduced in part without written approval of
Shenzhen Anbotek Compliance Laboratory Limited.

Date of Test                                                  Dec. 20, 2018~Jan. 08, 2019



                                                                    0 L’}\fij     fi@l
Prepared By

                                                                 (Engineer / Oliay Yang)



                                                                     Snij Me’}
Reviewer

                                                               (Supervisor / Snowy Meng)




Approved & Authorized Signer
                                                                   Sel sho
                                                                (Manager / Sally Zhang)




                         Shenzhen Anbotek Compliance Laboratory Limited
       Tel:(86)755—26066440   Fax:(86)755—26014772   www.anbotek.com ~Code:AB—RF—O05—a


                                                 Shenzhen Anbotek Compliance Laboratory Limited
                            FCC ID: 2APSE-SIREN Page 4 of 29 Report No.: SZAWW181220002-03



1. General Information
1.1. Client Information
 Applicant              :   Roo Inc.
 Address                :
                            41 E 11th Street 10th Floor, New York City, New York, United States, 10003

 Manufacturer           :   Roo Inc.
 Address                :
                            41 E 11th Street 10th Floor, New York City, New York, United States, 10003

 Factory                :   Roo Inc.

 Address                :   41 E 11th Street 10th Floor, New York City, New York, United States, 10003


1.2. Description of Device (EUT)
 Product Name           :   Keypad Siren
                            SIREN, SIREN1, SIREN2, SIREN3, SIREN4,SIREN5, SIREN6, SIREN7, SIREN8,
                            SIREN9
 Model No.              :
                            (Note: All samples are the same except the name, so we prepare "SIREN" for test
                            only.)
 Trade Mark             :   Kangaroo

 Test Power Supply      :   AC 120V, 60Hz for adapter / AC 240V, 60Hz for adapter

 Test Sample No.        :   S1(Normal Sample), S2(Engineering Sample)

                            Operation Frequency:              13.56MHz

                            Number of Channel:                1 Channels
 Product
                        :   Modulation Type:                  RFID
 Description
                            Antenna Type:                     PCB Antenna

                            Antenna Gain(Peak):               0 dBi
Remark: 1) For a more detailed features description, please refer to the manufacturer’s specifications or the
User’s Manual.
2)This report is for NFC module.


1.3. Auxiliary Equipment Used During Test
 Adapter                :   Model: A122-0502400UB
                            INPUT: 100-240V~50/60Hz 0.4A Max
                            OUTPUT: DC 5V, 2400mA




                        Shenzhen Anbotek Compliance Laboratory Limited
      Tel:(86)755-26066440  Fax:(86)755-26014772    www.anbotek.com Code:AB-RF-05-a


                                                 Shenzhen Anbotek Compliance Laboratory Limited
                            FCC ID: 2APSE-SIREN Page 5 of 29 Report No.: SZAWW181220002-03


1.4. Description of Test Modes
To investigate the maximum EMI emission characteristics generates from EUT, the test system was pre-scanning
tested base on the consideration of following EUT operation mode or test configuration mode which possible have
effect on EMI emission level. Each of these EUT operation mode(s) or test configuration mode(s) mentioned
above was evaluated respectively.
          Pretest Mode                                            Description
             Mode 1                                                  CH01



1.5. List of channels
                                  Channel                           Freq.
                                                                   (MHz)
                                    01                             13.56


Note:
1. The engineering test program was provided and the EUT was programmed to be in continuously transmitting
mode.




                         Shenzhen Anbotek Compliance Laboratory Limited
       Tel:(86)755-26066440  Fax:(86)755-26014772    www.anbotek.com Code:AB-RF-05-a


                                                 Shenzhen Anbotek Compliance Laboratory Limited
                            FCC ID: 2APSE-SIREN Page 6 of 29 Report No.: SZAWW181220002-03



 1.6. Description Of Test Setup

       CE
                                                       USB


                                                                           AC Line
                                               E-1               E-2
                                               EUT              Adapter               LISN


 0.8m




               Table
             Table

                                        1.5m



       RE

                                                      USB


                                                                            AC Line
                                                E-1            E-2
                                                EUT           Adapter

0.8m




          Table
        Table

                                      1.5m




                              Shenzhen Anbotek Compliance Laboratory Limited
            Tel:(86)755-26066440  Fax:(86)755-26014772    www.anbotek.com Code:AB-RF-05-a


                                                   Shenzhen Anbotek Compliance Laboratory Limited
                              FCC ID: 2APSE-SIREN Page 7 of 29 Report No.: SZAWW181220002-03


1.7. Test Equipment List
                                                                                                     Cal.
 Item        Equipment            Manufacturer         Model No.      Serial No.      Last Cal.
                                                                                                    Interval
              L.I.S.N.
  1.       Artificial Mains     Rohde & Schwarz         ENV216         100055       Nov. 05, 2018   1 Year
              Network
  2.      EMI Test Receiver     Rohde & Schwarz          ESPI3         101604       Nov. 05, 2018   1 Year

  3.      RF Switching Unit    Compliance Direction    RSU-M2           38303       Nov. 05, 2018   1 Year

  4.      Spectrum Analysis          Agilent            E4407B       US39390582     Nov. 05, 2018   1 Year
           MAX Spectrum
  5.                                 Agilent            N9020A       MY51170037     Nov. 05, 2018   1 Year
              Analysis
  6.        Preamplifier         SKET Electronic      BK1G18G30D      KD17503       Nov. 05, 2018   1 Year
         Double Ridged Horn        Instruments
  7.                                                   GTH-0118        351600       Nov. 20, 2018   1 Year
              Antenna              corporation
          Bilog Broadband
  8.                              Schwarzbeck          VULB9163     VULB 9163-289   Nov. 19, 2018   1 Year
              Antenna
  9.        Loop Antenna          Schwarzbeck         FMZB1519B         00053       Nov. 20, 2018   1 Year
                                                      LB-180400-K
 10.        Horn Antenna             A-INFO                          J211060628     Nov. 20, 2018   1 Year
                                                          F
 11.        Pre-amplifier           SONOMA               310N          186860       Nov. 05, 2018   1 Year
         EMI Test Software
 12.                               SHURPLE               N/A            N/A             N/A          N/A
              EZ-EMC
           RF Test Control
 13.                                YIHENG              YH3000         2017430      Nov. 05, 2018   1 Year
               System
 14.        Power Sensor             DAER              RPR3006W     15I00041SN045   Nov. 05, 2018   1 Year

 15.        Power Sensor             DAER              RPR3006W     15I00041SN046   Nov. 05, 2018   1 Year
           MXA Spectrum
 16.                                 Agilent            N9020A       MY51170037     Nov. 05, 2018   1 Year
              Analysis
        MXG RF Vector Signal
 17.                                 Agilent            N5182A       MY48180656     Nov. 05, 2018   1 Year
              Generator
 18.      Signal Generator           Agilent            E4421B       MY41000743     Nov. 05, 2018   1 Year

 19.      DC Power Supply          IVYTECH              IV3605      1804D360510     Apr. 02, 2018   1 Year
        Constant Temperature
 20.                              ZHONGJIAN           ZJ-KHWS80B        N/A         Nov. 01, 2018   1 Year
         Humidity Chamber




                          Shenzhen Anbotek Compliance Laboratory Limited
        Tel:(86)755-26066440  Fax:(86)755-26014772    www.anbotek.com Code:AB-RF-05-a


                                                   Shenzhen Anbotek Compliance Laboratory Limited
                              FCC ID: 2APSE-SIREN Page 8 of 29 Report No.: SZAWW181220002-03


1.8. Measurement Uncertainty
 Radiation Uncertainty                :   Ur = 3.9 dB (Horizontal)
                                          Ur = 3.8 dB (Vertical)


 Conduction Uncertainty               :   Uc = 3.4 dB



1.9. Description of Test Facility
The test facility is recognized, certified, or accredited by the following organizations:

FCC-Registration No.: 184111
Shenzhen Anbotek Compliance Laboratory Limited, EMC Laboratory has been registed and fully described in a
report filed with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is
maintained in our files. Registration No. 184111, July 31, 2017.

ISED-Registration No.: 8058A-1
Shenzhen Anbotek Compliance Laboratory Limited, EMC Laboratory has been registered and fully described in a
report filed with the (ISED) Innovation, Science and Economic Development Canada. The acceptance letter from
the ISED is maintained in our files. Registration 8058A-1, June 13, 2016.

Test Location
Shenzhen Anbotek Compliance Laboratory Limited.
1/F, Building D, Sogood Science and Technology Park, Sanwei community, Hangcheng Street, Bao'an District,
Shenzhen, Guangdong, China.518102




                         Shenzhen Anbotek Compliance Laboratory Limited
       Tel:(86)755-26066440  Fax:(86)755-26014772    www.anbotek.com Code:AB-RF-05-a


                                                 Shenzhen Anbotek Compliance Laboratory Limited
                            FCC ID: 2APSE-SIREN Page 9 of 29 Report No.: SZAWW181220002-03




2. Test Procedure

GENERAL: This report shall NOT be reproduced except in full without the written approval of Shenzhen
Anbotek Compliance Laboratory Limited. The EUT was transmitting a test signal during the testing.

RADIATION INTERFERENCE: The test procedure used was ANSI STANDARD C63.10-2013 using a
spectrum analyzer with a pre-selector. The analyzer was calibrated in dB above a microvolt at the output of the
antenna. The resolution bandwidth was 100KHz and the video bandwidth was 300KHz up to 1.0GHz and 1.0MHz
with a video BW of 3.0MHz above 1.0GHz. The ambient temperature of the EUT was 74.3oF with a humidity of
69%.

FORMULA OF CONVERSION FACTORS: The Field Strength at 3m was established by adding the meter
reading of the spectrum analyzer (which is set to read in units of dBuV) to the antenna correction factor supplied
by the antenna manufacturer. The antenna correction factors are stated in terms of dB. The gain of the Preselector
was accounted for in the Spectrum Analyzer Meter Reading.

Example:
Freq (MHz) METER READING + ACF = FS
33 20 dBuV + 10.36 dB = 30.36 dBuV/m @ 3m

ANSI STANDARD C63.10-2013 10.1.7 MEASUREMENT PROCEDURES: The EUT was placed on a table
80 cm high and with dimensions of 1m by 1.5m. The EUT was placed in the center of the table (1.5m side). The
table used for radiated measurements is capable of continuous rotation.
When an emission was found, the table was rotated to produce the maximum signal strength. At this point, the
antenna was raised and lowered from 1m to 4m. The antenna was placed in both the horizontal and vertical planes.




                         Shenzhen Anbotek Compliance Laboratory Limited
       Tel:(86)755-26066440  Fax:(86)755-26014772    www.anbotek.com Code:AB-RF-05-a


                                              Shenzhen Anbotek Compliance Laboratory Limited
                        FCC ID: 2APSE-SIREN Page 10 of 29 Report No.: SZAWW181220002-03




  3. Summary of Test Results

Standard Section                  Test Item                                   Result

15.203/15.247(c)                  Antenna Requirement                          PASS

15.207                            Conducted Emission                           PASS

15.205/15.209                     Spurious Emission                            PASS

                                  Frequency Tolerance                          PASS

15.215 (c)                        20dB Occupied Bandwidth                      PASS

Remark: “N/A” is an abbreviation for Not Applicable.




                        Shenzhen Anbotek Compliance Laboratory Limited
      Tel:(86)755-26066440  Fax:(86)755-26014772    www.anbotek.com Code:AB-RF-05-a


                                                   Shenzhen Anbotek Compliance Laboratory Limited
                             FCC ID: 2APSE-SIREN Page 11 of 29 Report No.: SZAWW181220002-03



4. Conducted Emission Test
4.1. Test Standard and Limit
Test Standard           FCC Part15 Section 15.207

                                                                         Maximum RF Line Voltage (dBuV)
                                Frequency
                                                            Quasi-peak Level                   Average Level

Test Limit                   150kHz~500kHz                      66 ~ 56 *                        56 ~ 46 *

                              500kHz~5MHz                           56                              46

                              5MHz~30MHz                            60                              50
Remark: (1) *Decreasing linearly with logarithm of the frequency.
          (2) The lower limit shall apply at the transition frequency.


4.2. Test Setup




4.3. Test Procedure
The EUT system is connected to the power mains through a line impedance stabilization network (L.I.S.N.). This
provides a 50ohm coupling impedance for the EUT system. Please refer the block diagram of the test setup and
photographs. Both sides of AC line are checked to find out the maximum conducted emission. In order to find the
maximum emission levels, the relative positions of equipment and all of the interface cables shall be changed
according to FCC ANSI C63.10-2013 on Conducted Emission Measurement.
The bandwidth of test receiver (ESCI) set at 9kHz.
The frequency range from 150kHz to 30MHz is checked.



4.4. Test Data
Please to see the following pages.



                         Shenzhen Anbotek Compliance Laboratory Limited
       Tel:(86)755-26066440  Fax:(86)755-26014772    www.anbotek.com Code:AB-RF-05-a


                                             Shenzhen Anbotek Compliance Laboratory Limited
                       FCC ID: 2APSE-SIREN Page 12 of 29 Report No.: SZAWW181220002-03


Conducted Emission Test Data
Test Site:                  1# Shielded Room
Operating Condition:        CH01
Test Specification:        AC 240V, 60Hz for adapter
Comment:                   Live Line
                           Tem.: 22.6℃ Hum.: 42%




                         Shenzhen Anbotek Compliance Laboratory Limited
       Tel:(86)755-26066440  Fax:(86)755-26014772    www.anbotek.com Code:AB-RF-05-a


                                             Shenzhen Anbotek Compliance Laboratory Limited
                       FCC ID: 2APSE-SIREN Page 13 of 29 Report No.: SZAWW181220002-03


Conducted Emission Test Data
Test Site:                  1# Shielded Room
Operating Condition:        CH01
Test Specification:        AC 240V, 60Hz for adapter
Comment:                   Neutral Line
                           Tem.: 22.6℃ Hum.: 42%




                         Shenzhen Anbotek Compliance Laboratory Limited
       Tel:(86)755-26066440  Fax:(86)755-26014772    www.anbotek.com Code:AB-RF-05-a


                                             Shenzhen Anbotek Compliance Laboratory Limited
                       FCC ID: 2APSE-SIREN Page 14 of 29 Report No.: SZAWW181220002-03


Conducted Emission Test Data
Test Site:                  1# Shielded Room
Operating Condition:        CH01
Test Specification:        AC 120V, 60Hz for adapter
Comment:                   Live Line
                           Tem.: 22.6℃ Hum.: 42%




                         Shenzhen Anbotek Compliance Laboratory Limited
       Tel:(86)755-26066440  Fax:(86)755-26014772    www.anbotek.com Code:AB-RF-05-a


                                             Shenzhen Anbotek Compliance Laboratory Limited
                       FCC ID: 2APSE-SIREN Page 15 of 29 Report No.: SZAWW181220002-03


Conducted Emission Test Data
Test Site:                  1# Shielded Room
Operating Condition:        CH01
Test Specification:        AC 120V, 60Hz for adapter
Comment:                   Neutral Line
                           Tem.: 22.6℃ Hum.: 42%




                         Shenzhen Anbotek Compliance Laboratory Limited
       Tel:(86)755-26066440  Fax:(86)755-26014772    www.anbotek.com Code:AB-RF-05-a


                                                   Shenzhen Anbotek Compliance Laboratory Limited
                             FCC ID: 2APSE-SIREN Page 16 of 29 Report No.: SZAWW181220002-03



5. Radiation Spurious Emission
5.1. Test Standard and Limit
Test Standard     FCC Part15 C Section 15.209 and 15.205
                          Frequency                Field strength          Limit                          Measurement
                                                                                           Remark
                            (MHz)                (microvolt/meter)       (dBuV/m)                         distance (m)
                    0.009MHz~0.490MHz               2400/F(kHz)               -                -               300

                    0.490MHz-1.705MHz              24000/F(kHz)               -                -               30

                      1.705MHz-30MHz                     30                   -                -               30

Test Limit             30MHz~88MHz                      100                 40.0          Quasi-peak            3

                       88MHz~216MHz                     150                 43.5          Quasi-peak            3

                      216MHz~960MHz                     200                 46.0          Quasi-peak            3

                     960MHz~1000MHz                     500                 54.0          Quasi-peak            3

                                                        500                 54.0           Average              3
                       Above 1000MHz
                                                          -                 74.0             Peak               3
Remark:
(1)The lower limit shall apply at the transition frequency.
(2) 15.35(b), Unless otherwise specified, the limit on peak radio frequency emissions is 20dB above the maximum
permitted average emission limit applicable to the equipment under test. This peak limit applies to the total peak
emission level radiated by the device.


5.2. Test Setup




                                                Figure 1. Below 30MHz




                         Shenzhen Anbotek Compliance Laboratory Limited
       Tel:(86)755-26066440  Fax:(86)755-26014772    www.anbotek.com Code:AB-RF-05-a


                                                 Shenzhen Anbotek Compliance Laboratory Limited
                           FCC ID: 2APSE-SIREN Page 17 of 29 Report No.: SZAWW181220002-03




                                           Figure 2. 30MHz to 1GHz




                                            Figure 3. Above 1 GHz


5.3. Test Procedure
For below 1GHz: The EUT is placed on a turntable, which is 0.8m above the ground plane.
For above 1GHz: The EUT is placed on a turntable, which is 1.5m above the ground plane.
The turn table can rotate 360 degrees to determine the position of the maximum emission level. The EUT is set 3
meters away from the receiving antenna which is mounted on a antenna tower. The antenna can be moved up and
down from 1 to 4 meters to find out the maximum emission level. Rotated the EUT through three orthogonal axes
to determine the maximum emissions, both horizontal and vertical polarization of the antenna are set on test. The
EUT is tested in 9*6*6 Chamber. The device is evaluated in xyz orientation.
For the radiated emission test above 1GHz:
Place the measurement antenna away from each area of the EUT determined to be a source of emissions at the
specified measurement distance, while keeping the measurement antenna aimed at the source of emissions at each
frequency of significant emissions, with polarization oriented for maximum response. The measurement antenna
may have to be higher or lower than the EUT, depending on the radiation pattern of the emission and staying

                         Shenzhen Anbotek Compliance Laboratory Limited
       Tel:(86)755-26066440  Fax:(86)755-26014772    www.anbotek.com Code:AB-RF-05-a


                                                  Shenzhen Anbotek Compliance Laboratory Limited
                            FCC ID: 2APSE-SIREN Page 18 of 29 Report No.: SZAWW181220002-03


aimed at the emission source for receiving the maximum signal. The final measurement antenna elevation shall be
that which maximizes the emissions. The measurement antenna elevation for maximum emissions shall be
restricted to a range of heights of from 1 m to 4 m above the ground or reference ground plane.

For 9kHz to 150kHz, Set the spectrum analyzer as:
RBW = 200Hz, VBW =1kHz, Detector= Quasi-Peak, Trace mode= Max hold, Sweep- auto couple.

For 150kHz to 30MHz, Set the spectrum analyzer as:
RBW = 9KHz, VBW =30kHz, Detector= Quasi-Peak, Trace mode= Max hold, Sweep- auto couple.

For 30MHz to 1000MHz, Set the spectrum analyzer as:
RBW = 100kHz, VBW =300kHz,Detector= Quasi-Peak, Trace mode= Max hold, Sweep- auto couple.

For above 1GHz,Set the spectrum analyzer as:
RBW =1MHz, VBW =1MHz, Detector= Peak, Trace mode= Max hold, Sweep- auto couple.
RBW =1MHz, VBW =10Hz, Detector= Average, Trace mode= Max hold, Sweep- auto couple.


5.4. Test Data
PASS
only the worst case is recorded in the report.




                         Shenzhen Anbotek Compliance Laboratory Limited
       Tel:(86)755-26066440  Fax:(86)755-26014772    www.anbotek.com Code:AB-RF-05-a


                                              Shenzhen Anbotek Compliance Laboratory Limited
                        FCC ID: 2APSE-SIREN Page 19 of 29 Report No.: SZAWW181220002-03



Field Strength within the band of operation
                                              Result at 3m      Limitation Converted 3m
     Freq.(MHz)       Ant. Orientation                                                      Margin dB
                                               (dBuV/m)             dist. (dBuV/m)
       13.110              Front                 57.68                    80.5                -22.82
       13.410              Front                 62.15                    80.5                -18.35
       13.553              Front                 73.96                    90.5                -16.54
       13.560              Front                 85.63                    124                 -38.37
       13.567              Front                 63.57                    90.5                -26.93
       13.710              Front                 62.42                    80.5                -18.08
       14.010              Front                 56.31                    80.5                -24.19
         --                  --                    --                      --                   --
       13.110               Side                 54.22                   80.5                 -26.28
       13.410               Side                 59.99                    80.5                -20.51
       13.553               Side                 70.64                    90.5                -19.86
       13.560               Side                 85.73                    124                 -38.27
       13.567               Side                 66.08                    90.5                -24.42
       13.710               Side                 54.33                    80.5                -26.17
       14.010               Side                 63.37                    80.5                -17.13
         --                  --                    --                      --                   --


    Remark:
    (1) Spectrum Setting:
        150 K Hz – 30 MHz, RBW= 9 KHz, VBW=9 KHz, Sweep time = 200 ms.
    (2) The Log-Bicon Antenna will use to test frequency range from 30MHz to 1000MHz and the Loop Antenna
        will use to test frequency below 30MHz.
    (3) If the peak scan value lower limit more than 20dB, then this signal data does not show in table.
    (4) Only the worst case (x orientation).




                        Shenzhen Anbotek Compliance Laboratory Limited
      Tel:(86)755-26066440  Fax:(86)755-26014772    www.anbotek.com Code:AB-RF-05-a


                                                  Shenzhen Anbotek Compliance Laboratory Limited
                            FCC ID: 2APSE-SIREN Page 20 of 29 Report No.: SZAWW181220002-03


Field strength outside of the band of operationTest


 Job No.:          SZAWW181220002-03                  Temp.(℃)/Hum.(%RH):   21.4℃/56%RH
 Standard:         FCC PART 15C                       Power Source:         AC 120V, 60Hz for adapter
 Test Mode:        Mode 1                             Polarization:         Horizontal




                         Shenzhen Anbotek Compliance Laboratory Limited
       Tel:(86)755-26066440  Fax:(86)755-26014772    www.anbotek.com Code:AB-RF-05-a


                                                Shenzhen Anbotek Compliance Laboratory Limited
                          FCC ID: 2APSE-SIREN Page 21 of 29 Report No.: SZAWW181220002-03


Test Results (30~1000MHz)
 Job No.:        SZAWW181220002-03             Temp.(℃)/Hum.(%RH):    21.4℃/56%RH
 Standard:       FCC PART 15C                  Power Source:          AC 120V, 60Hz for adapter
 Test Mode:      Mode 1                        Polarization:          Vertical




                        Shenzhen Anbotek Compliance Laboratory Limited
      Tel:(86)755-26066440  Fax:(86)755-26014772    www.anbotek.com Code:AB-RF-05-a


                                                 Shenzhen Anbotek Compliance Laboratory Limited
                           FCC ID: 2APSE-SIREN Page 22 of 29 Report No.: SZAWW181220002-03



6. Frequency Tolerance
6.1. Test Standard and Limit
The frequency tolerance of the carrier signal shall be maintained within ±0.01% of the operating frequency.


                   Fundamental Frequency (MHz)              Limit of Tolerance Bandwidth (Hz)
                                13.56                           13.56*1000*1000*0.01%=1356




6.2. Test Setup




6.3. Test Procedure
Let the EUT works on temperature variation of −20 degrees to +50 degrees C at normal supply voltage, and for a
variation in the primary supply voltage from 85% to 115% of the rated supply voltage at a temperature of 20
degrees C. For battery operated equipment, the equipment tests shall be performed using a new battery.


6.4. Test Data
 Test Item           :      Frequency tolerance               Test Mode           :   CH 01
 Test Voltage        :      AC 120V, 60Hz for adapter         Temperature         :   See Below
 Test Result         :      PASS                              Humidity            :   50%RH




                Test Condition
                                 Temperature              Test Result                         Limit
                Voltage (V)
                                    (℃)                      (Hz)                             (Hz)
                                      -20                      21                              1356
 Normal
                AC 120V              +20                       10                              1356
Condition
                                     +50                       29                              1356

Extreme         AC 108V              +20                       30                              1356
Condition       AC 132V              +20                       18                              1356




                         Shenzhen Anbotek Compliance Laboratory Limited
       Tel:(86)755-26066440  Fax:(86)755-26014772    www.anbotek.com Code:AB-RF-05-a


Anbotek
Product Safety




         Agilent Spectrum Analyzer— Swept SA
           OJReJsoe_____                                       :              ALIGNAUTO                      10:49:56 PM Jan 04, 2019
         Marker 1 13.561000000 MHz                               .                 Aug Type: Log—Pwr              reace ul
                                           PNO: Wide    GJ   Trig: Free Run       Aug|Hold:>100/100                 WOs M
                                           IFGain:Low        #Atten: 40 dB                                           bet



                   Ref 30.00 dBm




         Center 13.5600 MHz                                                                                 Span 500.0 kHz
         #Res BW 10 kHz                             #VBW 10 kHz                                   Sweep 6.067 ms (1001 pts)
         MsG fis‘rflus


                                              Shenzhen Anbotek Compliance Laboratory Limited
                        FCC ID: 2APSE-SIREN Page 24 of 29 Report No.: SZAWW181220002-03



7. 20dB Bandwidth
7.1. Test Standard and Limit
According to 15.215 (c):
Intentional radiators operating under the alternative provisions to the general emission limits, as
contained in §§15.217 through 15.257 and in Subpart E of this part, must be designed to ensure that
the 20 dB bandwidth of the emission, or whatever bandwidth may otherwise be specified in the
specific rule section under which the equipment operates, is contained within the frequency band
designated in the rule section under which the equipment is operated.


7.2. Test Setup




7.3. Test Procedure
The bandwidth of the fundamental frequency was measured by spectrum analyzer with 30kHz
RBW and 100kHz VBW. The 20dB bandwidth is defined as the total spectrum the power of which
is higher than peak power minus 20dB.
7.4. Test Data


 Test Item         :   Power Spectral Density         Test Mode           :   CH 01
 Test Voltage      :   AC 120V, 60Hz for adapter      Temperature         :   23.5℃
 Test Result       :   PASS                           Humidity            :   50%RH



                           Frequency(MHz)                 20dB BW(kHz)
                                13.56                             386.2




                        Shenzhen Anbotek Compliance Laboratory Limited
      Tel:(86)755-26066440  Fax:(86)755-26014772    www.anbotek.com Code:AB-RF-05-a


Anbotek
Product Safety




         Agilent Spectrum Analyzer— Occupied BW
                                   soe   _ac ______                   :                   ALIGNAUTO                    10:49:34 PM Jan04, 2019
         Center Freq 13.560000 MHz                                  Center Freq: 13.560000 MHz                   Radio Std: None
                                                             c      Trig: Free Run            Aug|Hold:> 10710
                                                 #IEGain:Low *~——   datten: 40 dB                                Radio Device: BTS



                        Ref 30.00 dBm




                                                                                                                            Span 3 MHz
                                                                         #VBW 100 kHz                                   Sweep 3.2 ms

           Occupied Bandwidth                                       Total Power                 20.2 dBm

                                      856.84 kHz
           Transmit Freq Error               209.00 kHz             OBW Power                     99.00 %
           x dB Bandwidth                      386.2 kHz            x dB                        —20.00 dB


                                               Shenzhen Anbotek Compliance Laboratory Limited
                         FCC ID: 2APSE-SIREN Page 26 of 29 Report No.: SZAWW181220002-03



8. Antenna Requirement
8.1. Test Standard and Requirement
Test Standard      FCC Part15 Section 15.203

                           The EUT’S antenna should met the requirement of FCC part 15C section 15.203.
                            An intentional radiator shall be designed to ensure that no antenna other than that
                            furnished by the responsible party shall be used with the device.
                            Antenna requirement must meet at least one of the following:
Requirement                 1) Antenna must be permanently attached to device.
                            2) The antenna must use a unique type of connector to attach to the device.
                            3) Device must be professionally installed. The installer shall be responsible for
                            ensuring that the correct antenna is employed by the device.




8.2. Antenna Connected Construction
The antenna is a PCB Antenna which permanently attached, and the best case gain of the antenna is 0 dBi. It
complies with the standard requirement.



                                                                              NFC Antenna




                         Shenzhen Anbotek Compliance Laboratory Limited
       Tel:(86)755-26066440  Fax:(86)755-26014772    www.anbotek.com Code:AB-RF-05-a


                                               Shenzhen Anbotek Compliance Laboratory Limited
                         FCC ID: 2APSE-SIREN Page 27 of 29 Report No.: SZAWW181220002-03



APPENDIX I -- TEST SETUP PHOTOGRAPH
Please refer to the test report SZAWW181220002-01.




                         Shenzhen Anbotek Compliance Laboratory Limited
       Tel:(86)755-26066440  Fax:(86)755-26014772    www.anbotek.com Code:AB-RF-05-a


                                               Shenzhen Anbotek Compliance Laboratory Limited
                         FCC ID: 2APSE-SIREN Page 28 of 29 Report No.: SZAWW181220002-03



APPENDIX II -- EXTERNAL PHOTOGRAPH
Please refer to the test report SZAWW181220002-01.




                         Shenzhen Anbotek Compliance Laboratory Limited
       Tel:(86)755-26066440  Fax:(86)755-26014772    www.anbotek.com Code:AB-RF-05-a


                                               Shenzhen Anbotek Compliance Laboratory Limited
                         FCC ID: 2APSE-SIREN Page 29 of 29 Report No.: SZAWW181220002-03



APPENDIX III -- INTERNAL PHOTOGRAPH
Please refer to the test report SZAWW181220002-01.




                                 ---------------- End of Report ----------------

                         Shenzhen Anbotek Compliance Laboratory Limited
       Tel:(86)755-26066440  Fax:(86)755-26014772    www.anbotek.com Code:AB-RF-05-a



Document Created: 2019-07-05 20:38:07
Document Modified: 2019-07-05 20:38:07

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC