1. Applicable Standard
According to §1.1307(b)(1), systems operating under the provisions of this section
shall be operated in a manner that ensures that the public is not exposed to radio
frequency energy level in excess of the Commission’s guidelines.
According to §1.1310 and §2.1091 RF exposure is calculated.
KDB447498 v06: Mobile and Portable Devices RF Exposure Procedures and
Equipment Authorization Policies.


2. Limit

FCC:
Systems operating under the provisions of FCC 47 CFR section shall be operated in a
manner that ensures that the public is not exposed to radio frequency energy level in
excess of the Commission’s guidelines.
In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has
been defined as mobile device whereby a distance of 0.2m normally can be
maintained between the user and the device, and below RF Permissible Exposure
limit shall comply with.
In accordance with KDB447498D01 for Simultaneous transmission MPE test
exclusion applies when the sum of the MPE ratios for all simultaneous transmitting
antennas incorporated in a host device, based on the calculated/estimated,
numerically modeled or measured field strengths or power density, is ≤ 1.0. The MPE
ratio of each antenna is determined at the minimum test separation distance required
by the operating configurations and exposure conditions of the host device, according
to the ratio of field strengths or power density to MPE limit, at the test frequency.
Either the maximum peak or spatially averaged results from measurements or
numerical simulations may be used to determine the MPE ratios. Spatial averaging
does not apply when MPE is estimated using simple calculations based on far-field
plane-wave equivalent conditions. The antenna installation and operating
requirements for the host device must meet the minimum test separation distances
required by all antennas, in both standalone and simultaneous transmission
operations, to satisfy compliance.


Limits for Maximum Permissible Exposure (MPE)/Controlled Exposure
                                                                              Averaging
  Frequency        Electric Field    Magnetic Field     Power Density
                                                                                Time
 Range(MHz)        Strength(V/m)     Strength(A/m)        (mW/cm²)
                                                                               (minute)
                      Limits for Occupational/Controlled Exposure
   0.3 – 3.0
                        614                1.63              (100) *              6
   3.0 – 30
                       1842/f             4.89/f            (900/f2)*             6
   30 – 300
                        61.4              0.163                 1.0               6
  300 – 1500
                          /                  /                f/300               6
    1500 –
                          /                  /                   5                6
   100,000

Limits for Maximum Permissible Exposure (MPE)/Uncontrolled Exposure
                                                                              Averaging
  Frequency        Electric Field    Magnetic Field     Power Density
                                                                                Time
 Range(MHz)        Strength(V/m)     Strength(A/m)        (mW/cm²)
                                                                               (minute)
                      Limits for Occupational/Controlled Exposure
   0.3 – 3.0
                         614               1.63              (100) *              30
   3.0 – 30
                        824/f             2.19/f            (180/f2)*             30
   30 – 300
                        27.5              0.073                0.2                30
  300 – 1500
                          /                  /               f/1500               30
    1500 –
                          /                  /                 1.0                30
   100,000

F=frequency in MHz
*=Plane-wave equivalent power density


3. MPE Calculation Method

    FCC:
Predication of MPE limit at a given distance
Equation from page 18 of OET Bulletin 65, Edition 97-01

S=PG/4πR²
Where: S=power density
       P=power input to antenna
       G=power gain of the antenna in the direction of interest relative to an isotropic
         radiator
       R=distance to the center of radiation of the antenna


4. Result

                   Minimum        Output Power                         Power         Power
                                                         Antenna
                Separatio     (Turn-up Procedure)                     Density       Density        Test
   Mode                                                    Gain
                n Distance                                           At 20 cm        Limit        Results
                                 dBm            mW       (Numeric)             2              2
                    (cm)                                             (mW/cm )      (mW/cm )
LTE Band 2          20.00        23.0           199.53     1.04      0.0413032       1.0000       PASS
LTE Band 4          20.00         23.0          199.53     1.04      0.0413032       1.0000       PASS
LTE Band 5          20.00         22.6       181.97        1.36      0.0492594        0.53        PASS
LTE Band 12         20.00         22.0          158.49     1.36      0.0429032        0.47        PASS
LTE Band 13         20.00         22.0          158.49     1.36      0.0429032        0.47        PASS
 WIFI 2.4G          20.00         13.0           19.95      1        0.0039709       1.0000       PASS




5. Simultaneous transmission MPE Considerations

According to KDB447498 :For mobile exposure host platform to qualify for simultaneous
transmission MPE test exclusion, all transmitters and antennas in the host must be either
evaluated for MPE compliance, by measurement or computational modeling, or qualify for the
standalone MPE test exclusion in section 7.1.
Simultaneous transmission MPE test exclusion applies when the sum of the MPE ratios for all
simultaneous transmitting antennas incorporated in a host device, based on the
calculated/estimated, numerically modeled or measured field strengths or power density, is ≤
1.0.
This means that:
∑ of MPE ratios ≤ 1.0


The EUT is Not Applicable.

6. Conclusion
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment.