Date : 2018-06-05                                                                           Page 1 of 1
No. : HM18050007


 3.1.5   RF Exposure

 RF Exposure

 Test Requirement:                   FCC 47CFR 15.247(i)
 Test Date:                          2018-05-18
 Mode of Operation:                  Tx mode

 Requirements:

 In 15.247(i), an equipment shall be operated in a manner that ensures that the public is not exposed to
 radio frequency energy levels in excess of the limits in §§ 1.1310 and 2.1093 of this chapter.
 Applications to the Commission for construction permits, licenses to transmit or renewals thereof,
 equipment authorizations or modifications in existing facilities must contain a statement confirming
 compliance with the limits unless the facility, operation, or transmitter is categorically excluded, as
 discussed below. Technical information showing the basis for this statement must be submitted to the
 Commission upon request.

 According to KDB447498 D01 General RF Exposure Guidance v06, unless specifically required by the
 published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation
 for general population exposure conditions, by measurement or numerical simulation, is not required when
 the corresponding SAR Exclusion Threshold condition.
 Test Results:

RF Exposure Evaluation

The Maximum tune-up power = 6.01dBm (3.99mW)

SAR Test Exclusion Thresholds=1.98≤ 3.0 for 1-g SAR,

The test separation distances is ≤5 mm
The power tune up tolerance is 4.31±1.70dBm
Max. duty factor is 100%



Document Created: 2018-06-14 12:02:52