1. MAXIMUM PERMISSIBLE EXPOSURE (MPE)

1.1 General Information

 Client Information
 Applicant:                           Guangzhou Juan Intelligent Tech Joint Stock Co.,Ltd
 Address of applicant:                No.2 Plant, West of Shanxi country, Dashi street, Panyu District,
                                      Guangzhou, China

 Manufacturer:                        Guangzhou Juan Intelligent Tech Joint Stock Co.,Ltd
 Address of manufacturer:             No.2 Plant, West of Shanxi country, Dashi street, Panyu District,
                                      Guangzhou, China
 General Description of EUT:
 Product Name:                        Network Video Recorder
 Trade Name:                          /
                                      K8204-W, K8208-W, K8204H-W, K8208H-W, K8304H-W, K8304-W,
 Model No.:                           T8204-W, T8208-W, ZR04JB/00, ZR04JB/10, ZR08KB/00, ZR08KB/10,
                                      ZR08QB/00, ZR08QB/10, ZR08QB/20, ZHS-A212, ZHR-A2200
 FCC ID:                              2APRB-K8204-W
 Rated Voltage:                       Adapter: DC12V

 Technical Characteristics of EUT:
 Wi-Fi
 Support Standards:                802.11b, 802.11g, 802.11n
                                   2412-2462MHz for 802.11b/g/n(HT20)
 Frequency Range:
                                   2422-2452MHz for 802.11n(HT40)
 RF Output Power:                  16.52dBm (Conducted)
 Type of Modulation:               CCK, OFDM, QPSK, BPSK, 16QAM, 64QAM
 Data Rate:                        1-11Mbps, 6-54Mbps, up to 300Mbps
 Quantity of Channels:             11 for 802.11b/g/n(HT20); 7 for 802.11n(HT40)
 Channel Separation:               5MHz
 Type of Antenna:                  Undetachable External Antenna
 Antenna Gain:                     5.0dBi

1.2 Standard Applicable

According to §1.1307(b)(1) and KDB 447498 D01 General RF Exposure Guidance v06, system operating under
the provisions of this section shall be operating in a manner that the public is not exposed to radio frequency
energy level in excess limit for maximum permissible exposure.


(a) Limits for Occupational / Controlled Exposure


                                Electric Field      Magnetic Field                              Averaging Times
         Frequency range                                                  Power Density
                                Strength (E)         Strength (H)                                | E |2, | H |2 or
             (MHz)                                                        (S) (mW/cm2)
                                   (V/m)                (A/m)                                      S (minutes)
              0.3-3.0                614                  1.63                (100)*                    6
              3.0-30               1842/f                4.89/f              (900/f)*                   6
              30-300                 61.4                0.163                  1.0                     6
             300-1500                 /                     /                 F/300                     6
           1500-100000                /                     /                    5                      6


(b) Limits for General Population / Uncontrolled Exposure


                                Electric Field      Magnetic Field                              Averaging Times
         Frequency range                                                  Power Density
                                Strength (E)         Strength (H)                                | E |2, | H |2 or
             (MHz)                                                        (S) (mW/cm2)
                                   (V/m)                (A/m)                                      S (minutes)
             0.3-1.34                614                  1.63                (100)*                   30
              1.34-30               824/f                2.19/f              (180/f)*                  30
              30-300                 27.5                0.073                  0.2                    30
             300-1500                 /                     /                 F/1500                   30
           1500-100000                /                     /                    1                     30
       Note: f = frequency in MHz: * = Plane-wave equivalents power density

1.3 MPE Calculation Method

S = (30*P*G) / (377*R2)
S = power density (in appropriate units, e.g., mw/cm2)
P = power input to the antenna (in appropriate units, e.g., mw)
G = power gain of the antenna in the direction of interest relative to an isotropic radiator,
  the power gain factor is normally numeric gain.
R = distance to the center of radiation of the antenna (in appropriate units, e.g., cm)


1.4 MPE Calculation Result

Maximum Tune-Up output power: 17.0 (dBm)
Maximum peak output power at antenna input terminal: 50.12 (mW)
Prediction distance: >20(cm)
Prediction frequency: 2412 (MHz)
Antenna gain: 5(dBi)
Directional gain (numeric gain): 3.16
The worst case is power density at prediction frequency at 20cm: 0.032(mw/cm2)
MPE limit for general population exposure at prediction frequency: 1 (mw/cm2)



Result: Pass