RF Exposure Info

FCC ID: 2APRA83101

RF Exposure Info

Download: PDF
FCCID_3897952

                                                                  SGS-CSTC Standards Technical Services
                                                                  (Shanghai) Co., Ltd.

    588 West Jindu Road, Xinqiao, Songjiang, 201612 Shanghai, China
    Telephone:    +86 (0) 21 6191 5666
    Fax:          +86 (0) 21 6191 5678                                                                                                           Report No.: SHEM180400299704
    ee.shanghai@sgs.com                                                                                                                          Page:             1 of 8



   1           Cover Page

                                                    RF Exposure REPORT
    Application No.:                                SHEM1804002997CR
    Applicant:                                      Siemens Shanghai Medical Equipment Ltd.
    FCC ID:                                         2APRA83101
    IC:                                             23852-83101
    Equipment Under Test (EUT):
    NOTE: The following sample(s) submitted was/were identified on behalf of the client as
    Product Name:                                   BlockBots
    Model No.(EUT):                                 83101
    Add Model No.:                                  83102, 83103, 83104, 83105, 83106, 83107, 83108, 83109, 83110
    Standards:                                      FCC Rules 47 CFR §2.1093
                                                    KDB 447498 D01 General RF Exposure Guidance v06
                                                    RSS-102 Issue 5 (March 2015)
    Date of Receipt:                                2018-04-24
    Date of Test:                                   2018-05-09 to 2018-05-15
    Date of Issue:                                  2018-06-02
    Test Result:                                    Pass*
   *In the configuration tested, the EUT detailed in this report complied with the standards specified above.




                      Parlam Zhan
                   E&E Section Manager
The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report. If
the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure the new system
complies with all relevant standards. Any mention of SGS International Electrical Approvals or testing done by SGS International Electrical
Approvals in connection with, distribution or use of the product described in this report must be approved by SGS International Electrical
Approvals in writing.
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx
and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to
the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the
time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from
exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized
alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results
shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 30 days only.


                                                    SGS-CSTC Standards Technical Services
                                                    (Shanghai) Co., Ltd.
                                                                                                                   Report No.: SHEM180400299704
                                                                                                                   Page:    2 of 8


                                                                    Revision Record
              Version                      Description                                    Date                                     Remark

                   00                         Original                               2018-06-02                                          /




          Authorized for issue
          by:




                                                           Vincent Zhu / Project Engineer




                                                           Parlam Zhan /Reviewer




 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at
www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at
www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this
document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their
rights and obligations under the transaction.documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any
unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of
the law. Unless otherwise stated the results shown in this test report refer only to thesample(s) tested and such sample(s) are retained for 90 days only


                                                     SGS—CSTC Standards Technical Services
                                                     (Shanghai) Co., Ltd.
                                                                                                                       Report No.: SHEM180400299704
                                           |                                                                           Page:    _3 of 8


2           Contents
                                                                                                                                                                  Page

1          COVER PAGE ...                                                                                                                                              1

2          CONTENTS                                                                                                                                             eesee. 3
3          GENERAL INFORMATION.....                                                                                                                                    4
     3.1     CLIENT INFORMATION...222222222222020000000errrrrrrrrrrrrrrrrrrrrrrrrrrrrerrrresseeeeeseeresseeeeeeeeeeesssssssssseerrrrrrrrrerrrrrrrrrresseeeees 4
     3.2     GENERAL DESCRIPTION OF E.U,JT . 12222222222222222222ss¥¥¥¥sssrsrrrrrrrrrrressssssseeresssssesseeeessssssssssserrrrrrrrrrrrrrrrrrrrr es se se ees 4

     3.3     DETAILS OFE.U.T . 22.2222222022220222rsrrersssssssrrrrrrsssrssrerrrrsssssseerrrresssssseerssersssesssseseresssesssenrersssesssenrrrsss en enerrr en es 4
     3.4     TEST LOCATION....22222222222222rreerrssssrrrreeeeesssrrrrrrrrrressssseeeseesssereseerrrressseeessseeeerererrrressssssessseeererrrrrrrrnnnnn en en es 5

     3.5     TEST FACILITY....22200000022222sssrressssssssreeeeesesssrrrrrrrrrrsssssss es es sserrseerrrressseessssseeerererrrrsssssssessseeererrrrrrrrrnnnn en n en es 5

4          TEST STANDARDS AND LIMITS......                                                                                                                             6
     4.1     FCC RADIOFREQUENCY RADIATION EXPOSURE LIMITS ....222222222222222206606ss66¥¥skrrrs 66666666 srrrsss 66e es s se es se e es se e 0. 6
     4.2      IC RADIOFREQUENCY RADIATION EXPOSURE LIMITS......222222222202002220srr66s6666¥kkrrrs 66666666 se es se iess es s s se es se e es s se e 0. 7

35         MEASUREMENT AND CALCULATION.......                                                                                                                          8
     5.1     MAXIMUM TRANSMIT POWER....222.....22222202222226rrrrrrrrrrrssrrssssssssssssssssresssessssssssssessserrrrreerrressssssse es se serrrrrrrreees 8

     5.2     RF EXPOSURE CALCULATION...2222222222222222222rrrrerrrrrrrrrerrrrssssseeseessssseessseesssssseseesseeerrrrenrrresssssseeessseserrrrrrrrnnes 8




 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at
www.sqs.com/terms and conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at
www.sqs.com/terms e—document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this
document is advised that information contained hereon reflects the Company‘s findings at the time of its intervention only and within the limits of Client‘s
instructions, if any. The Company‘s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their
rights and obligations under the transaction.documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any
unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of
the law. Unless otherwise stated the results shown in this test report refer only to thesample(s) tested and such sample(s) are retained for 90 days only


                                                    SGS-CSTC Standards Technical Services
                                                    (Shanghai) Co., Ltd.
                                                                                                                   Report No.: SHEM180400299704
                                                                                                                   Page:    4 of 8



3        General Information
3.1 Client Information
       Applicant:                                   PAI TECHNOLOGY LIMITED
       Address of Applicant:                        11/F, Block 02, 101 King's Road, North Point, Hong Kong
       Manufacturer:                                PAI TECHNOLOGY LIMITED
       Address of Manufacturer:                     11/F, Block 02, 101 King's Road, North Point, Hong Kong

3.2 General Description of E.U.T.
       Power supply:                                Battery 3.7V 1500mAh
                                                    DC 5V 1A via USB port
       Test voltage:                                AC 120V 60Hz
       Cable:                                       0.5m for DC cable

3.3 Details of E.U.T.
BLE
     Antenna Gain                                   0 dBi
     Antenna Type                                   PCB Antenna
     Channel Spacing                                2MHz
     Modulation Type                                GFSK
     Number of Channels                             40
     Operation Frequency                            2402MHz to 2480MHz


BT
           Antenna Gain                             0dBi
           Antenna Type                             PCB Antenna
           Channel Spacing                          1MHz
           Modulation Type                          GFSK, π/4DQPSK
           Number of Channels                       79
           Operation Frequency                      2402MHz to 2480MHz




 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at
www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at
www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this
document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their
rights and obligations under the transaction.documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any
unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of
the law. Unless otherwise stated the results shown in this test report refer only to thesample(s) tested and such sample(s) are retained for 90 days only


                                                    SGS-CSTC Standards Technical Services
                                                    (Shanghai) Co., Ltd.
                                                                                                                   Report No.: SHEM180400299704
                                                                                                                   Page:    5 of 8



3.4 Test Location
  All tests were performed at:
  SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd.
  588 West Jindu Road, Xinqiao, Songjiang, 201612 Shanghai, China.
  Tel: +86 21 6191 5666
  Fax: +86 21 6191 5678

3.5 Test Facility
 The test facility is recognized, certified, or accredited by the following organizations:
 • CNAS (No. CNAS L0599)
 CNAS has accredited SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. to ISO/IEC
 17025:2005 General Requirements for the Competence of Testing and Calibration Laboratories (CNAS-
 CL01 Accreditation Criteria for the Competence of Testing and Calibration Laboratories) for the
 competence in the field of testing.
 • NVLAP (Certificate No. 201034-0)
 SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. is accredited by the National Voluntary
 Laboratory Accreditation Program(NVLAP). Certificate No. 201034-0.
  • FCC –Designation Number: CN5033
 SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. has been recognized as an accredited
 testing laboratory.
 Designation Number: CN5033. Test Firm Registration Number: 479755.
 • Industry Canada (IC) – IC Assigned Code: 8617A
 The 3m Semi-anechoic chamber of SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. has
 been registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing
 with Registration No.: 8617A-1.
 • VCCI (Member No.: 3061)
 The 3m Semi-anechoic chamber and Shielded Room of SGS-CSTC Standards Technical Services
 (Shanghai) Co., Ltd. has been registered in accordance with the Regulations for Voluntary Control
 Measures with Registration No.: R-3868,C-4336,T-12221,G-10830 respectively.




 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at
www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at
www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this
document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their
rights and obligations under the transaction.documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any
unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of
the law. Unless otherwise stated the results shown in this test report refer only to thesample(s) tested and such sample(s) are retained for 90 days only


                                                    SGS—CSTC Standards Technical Services
                                                    (Shanghai) Co., Ltd.
                                                                                                                    Report No.: SHEM180400299704
                                          |                                                                         Page:          _6 of 8




4         Test Standards and Limits

4.1       FCC Radiofrequency radiation exposure limits
     The 1—g and 10—g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances
     < 50 mm are determined by:
     [(max power of channel)/(min test separation distance)]*[Vf(GHz)] < 3.0 for 1—g SAR and < 7.5 for
      10—g extremity SAR, where
      * f(GHz) is the RF channel transmit frequency in GHz
      +   Power and distance are rounded to the nearest mW and mm
      * The result is rounded to one decimal place for comparison
      * 3.0 and 7.5 are referred to as the numeric thresholds
     The test exclusions are applicable only when the minimum test separation distance is < 50 mm, and
     for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation
      distance is < 5 mm, a distance of 5 mm according to 4.1 f) is applied to determine SAR test
      exclusion.
      For 2.4G band device, the limit of worse case is

      Pma<3.0*Dmin)/ /f =3.0*5/ 2.480 =9.525mW




 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at
www.sqs.com/terms and conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at
www.sqs.com/terms e—document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this
document is advised that information contained hereon reflects the Company‘s findings at the time of its intervention only and within the limits of Client‘s
instructions, if any. The Company‘s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their
rights and obligations under the transaction.documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any
unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of
the law. Unless otherwise stated the results shown in this test report refer only to thesample(s) tested and such sample(s) are retained for 90 days only


                                                    SGS-CSTC Standards Technical Services
                                                    (Shanghai) Co., Ltd.
                                                                                                                   Report No.: SHEM180400299704
                                                                                                                   Page:    7 of 8


4.2 IC Radiofrequency radiation exposure limits
According to RSS-102 section 2.5.1, SAR evaluation is required if the separation distance between the
user and/or bystander and the antenna and/or radiating element of the device is less than or equal to
20 cm, except when the device operates at or below the applicable output power level (adjusted for
tune-up tolerance) for the specified separation distance
  MHz              5            10            15            20            25            30            35            40             45            50          mm
  ≤300            71           101           132           162           193           223           254           284            315           345
   450            52            70            88           106           123           141           159           177            195           213
   835            17            30            42            55            67            80            92           105            117           130
  1900             7            10            18            34            60            99           153           225            316           431          mW
  2450             4             7            15            30            52            83           123           173            235           309
  3500             2             6            16            32            55            86           124           170            225           290
  5800             1             6            15            27            41            56            71            85             97           106

Output power level shall be the higher of the maximum conducted or equivalent isotropically radiated
power (e.i.r.p.) source-based, time-averaged output power. For controlled use devices where the 8
W/kg for 1 gram of tissue applies, the exemption limits for routine evaluation are multiplied by a factor
of 5. For limb-worn devices where the 10 gram value applies, the exemption limits for routine
evaluation in Table 1 are multiplied by a factor of 2.5. If the operating frequency of the device is
between two frequencies located in Table 1, linear interpolation shall be applied for the applicable
separation distance. For test separation distance less than 5 mm, the exemption limits for a separation
distance of 5 mm can be applied to determine if a routine evaluation is required.
For 2.4G band device, the limit is Pmax≤4mW




 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at
www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at
www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this
document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their
rights and obligations under the transaction.documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any
unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of
the law. Unless otherwise stated the results shown in this test report refer only to thesample(s) tested and such sample(s) are retained for 90 days only


                                                    SGS-CSTC Standards Technical Services
                                                    (Shanghai) Co., Ltd.
                                                                                                                   Report No.: SHEM180400299704
                                                                                                                   Page:    8 of 8



5        Measurement and Calculation
5.1 Maximum transmit power
  The Power Data is based on the RF Test Report SHEM180400299702 & SHEM180400299704.
  Test Data:
  BLE
     Test Mode                             Test Channel                            Power[dBm]                            Peak Power (mW)
                                                  2402                                   0.29                                       1.07
              BLE                                 2440                                   -0.35                                      0.92
                                                  2480                                   -0.77                                      0.84

  BT
         Test Mode                          Test Channel                            Power[dBm]                           Peak Power (mW)
              DH5                                 2402                                    -2.92                                     0.51
              DH5                                 2441                                    -3.16                                     0.48
              DH5                                 2480                                    -3.89                                     0.41
             2DH5                                 2402                                    -0.31                                     0.93
             2DH5                                 2441                                    -0.50                                     0.89
             2DH5                                 2480                                    -1.19                                     0.76

5.2 RF Exposure Calculation
  The Max Conducted Peak Output Power is 1.07mW. The best case gain of the antenna is 0dBi. 0dBi
  logarithmic terms convert to numeric result is nearly 1.0

  According to the formula. calculate the EIRP test result:

  EIRP= P x G = 1.07 mW x 1.0 = 1.07mW <4mW < 9.525mW

  So the SAR report is not required.


                                                             --End of the Report--




 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at
www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at
www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this
document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their
rights and obligations under the transaction.documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any
unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of
the law. Unless otherwise stated the results shown in this test report refer only to thesample(s) tested and such sample(s) are retained for 90 days only



Document Created: 2018-06-22 02:50:39
Document Modified: 2018-06-22 02:50:39

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC